NES 730 UC
NES 930 UC
Bosch Ceramic Glass Cooktops
Models: NES 730 UC, NES 930 UC
mnstaHation Instructions HodeHs: NES 730, NES 930
Table of Contents
NOTE: The blocked letters, such as A, shown below, refer to illustrations on
Pages 2 & 4. klatch these to the related text pages.
Overall Dimensions A .................................................................................................. 2
Power Supply B ............................................................................................................. 2
Cabinet Preparation and Clearances O .............................................................. 2, 3
junction Box Location D ............................................................................................. 2
Countertop Cutout Dimensions E .......................................................................... 2
Installing the Cooktop F ......................................................................................... 3-4
Secure Cooktop to Countertop O ...................................................................... 3-4
Solid Surface Countertop Installations H and | ................................................ 4-5
Electrical Connection ................................................................................................... S
iMPORTANT: Save these instructions for Local Electrical mnspector's use.
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
READ AND SAVE THESE mNSTRUCTmONS
OVERALL DIMENSIONS A
See Illustration A, Page 2. These dimensions are
overall.
POWER SUPPLY
ELECTRICAL POWER CONNECTION
FOR COOKTOP
Power Supply is dual rated: 240 Volts or 208 Volts,
4 wire, 60 Hz, with the following circuit breaker
requirements: Model NES 730 at 30 Amps; Model
NES 930 at 40 Amps
JUNCTION BOX LOCATION
Plan the installation of the unit so that the location
of the junction box is within 3 feet of the left rear
of the cooktop bottom. It must be accessible
from the front of the cabinet.
D
Connect only to a 4-wire 120/240 or 120/208 volt
ac system. The neutral is required for the operation
of this appliance and an independent ground is
required.
Install a junction box (not supplied), below the
counter top within 3 feet of flexible conduit
(supplied) located at the left rear corner of the
cooktop rough-in box.
PAGE U
mnstammationmnstructions Hodeb: NES 730_NES 930
OveraJJ Dimensions
Mode[ NES 730:Width 30"
Mode[ NES 930:Width 36"
All Models: Depth 2 [- [/8"
Height above countertop: 1/4"
Minimum Cabinet Clearances
Cabinet Bottom
Building Back
Wall
Required Power SuppJy
Mode[ NES 730:30 Amp circuit breaker
Mode[ NES 930:40 Amp circuit breaker
All 240 Volt, 4 Wire, 60 Hz
208 Volt, 4 Wire, 60 Hz
Junction Box Location
Wall
EEl
II/'"i4 oxZ
MODEL NO.
NES 730
NES 930
DIM.
B
C
B
C
Cooking Sut face
Counter Top Cutout Dimensions
2-I/2'
Setback Distance
(from front edge of co/rater
to]:_ to flont edc_e of cutout )
Minimum
Inches / (mm)
[9-7/8"/(505 mm}
28-3t4" t (73[ mm}
[9"7t8'' t (505 mm)
34-3/4"/ (883 mm)
1" Flat Area
I-3/4" Flat Area
1" Flat Area
CUTOUT
DIMENSIONS*
Maximum
Inches / (mm)
20" / (508 mm}
28-7tB" t (734 mm)
20" t (508 mm)
34-7/8 '' / (886 mm)
SFor solid surface countertop installations, use maximum cutout dimensions and
consult surface manufacturer for specific cutting instructions.
PAGE 2