Bosch MIC400 User Manual 2

MIC400 Quick Start Guide
CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DISCONNECT POWER SUPPLY BEFORE OPENING THE POWER SUPPLY UNIT. POWER DISCONNECT: POWER SUPPLY UNITS HAVE POWER SUPPLIED WHENEVER THE POWER CORD IS INSERTED INTO THE POWER SOURCE
WARNING: INSTALLATION SHOULD BE CARRIED OUT BY QUALIFIED PERSONNEL ONLY IN ACCORDANCE WITH THE APPLICABLE LOCAL CODES. BOSCH SECURITY SYSTEM ACCEPTS NO LIABILITY FOR ANY DAMAGES OR LOSSES CAUSED DUE TO INCORRECT OR IMPROPER INSTALLATION.
Unit Mechanical mounting
The MIC400, if canted is designed only to be mounted ball up, the tilt limits for the canted unit prevent it from working properly if mounted ball down, the MIC412 and MIC440 cannot be canted.
WARNING: DUE CAUTION SHOULD BE EXERCISED WHEN INSTALLING THE MIC400 RANGE OF CAMERAS, COMMON SENSE PRECAUTIONS SUCH AS FITTING A SAFETY CHAIN SHOULD BE FOLLOWED. SPECIAL CARE SHOULD BE TAKEN WITH STAINLESS STEEL, MIC412 or MIC440 MODELS DUE TO THEIR EXTRA WEIGHT.
Bosch Security Systems Issue 1
Do not manually back drive the pan or tilt axis by hand. Back driving may strip teeth off the internal gears and in so doing will void the warranty.
M8 Stainless steel nuts, bolts and washers should be used to secure the base to the mounting surface. Suitable sealant or a gasket should be used between the camera base and the mounting surface.
Ensure that the 12 pin connector is located into the camera base plug and that the lock ring is tightened. Ensure that the base compartment containing the 12 way connector is moisture proof. On inverted units it is very important that the connector area is water tight to prevent water pooling around the connector.
The MiC400 series of PTZ cameras comes with a security attachment point as standard. This should be attached to a safety chain which in turn should be attached to a secure part of the structure.
Earthing the camera
The camera and camera housing are electrically isolated so the housing should be safety earthed regardless. This safety earth should be a bonding connection to the camera’s outside case. E.g. one of the securing screws used for bolting the camera down.
The camera should be earthed at one point only to prevent earth loops and thus hum bars appearing on the camera picture in the control room.
Connections between the MIC400 and the MIC-PSU using the MIC Composite Cable:
Note: all connections must be made
MIC400 Composite Cable Wire Colour
Function PSU Terminal
Connector
PSU Terminal ID marking
Red 15v AC supply HD3-1 Power Green 15v AC supply return HD3-2 Power White Camera Rx B HD3-3 RxB Yellow Camera Rx A HD3-4 RxA Drain Wire Gnd HD3-5 GND Blue Camera Tx A HD3-6 TxA Violet Camera Tx B HD3-7 TxB Coax Core Video HD3-8 Video Coax Screen Video Return HD3-9 Vid 0v
2 of 3
Page
BOSCH SECURITY SYSTEMS
Loading...