Intrusion Alarm Systems | ICP-SDI-9114 SDI Splitter
ICP-SDI-9114 SDI Splitter
www.boschsecurity.com
u Provides two independent, isolated SDI buses from
a single SDI connection to the control panel
u Can be used to meet the requirements for a UL864
compliant combination control panel
The ICP-SDI-9114 SDI Splitter allows the set up of two
independent, isolated SDI buses from a single SDI
connection on the control panel. When this accessory
is installed with a control panel and wired to create
separate SDI buses for fire and intrusion devices, the
system is a UL864 compliant combination control
panel.
Notice
The B9512G, B9512G-E, B8512G, and B8512G-E
control panels can be used as combination
systems per UL864, 9th edition requirements.
When using only the SDIx bus programmed for
legacy SDI communication, the ICP‑SDI‑9114 SDI
Splitter will be required.
Notice
The D9412GV4, D9412GV3, D9412GV2,
D7412GV4, D7412GV3, and D7412GV2 control
panels can be installed as a combination system
per UL864, 9th edition requirements when used
with the ICP‑SDI‑9114 SDI Splitter.
Notice
The D7212GV4, D7212GV3, D7212GV2, and
D7212G are not rated for Commercial Fire.
u Does not affect the operation of the control panel or
the associated SDI devices
u Additional power can be supplied by an external
power supply
Functions
Connections
The SDI splitter has three sets of four‑position SDI
terminals: PANEL, FIRE, and BURG. The PANEL
terminals are used for the SDI connection to the
control panel. The terminals labeled FIRE and BURG
are handled equally, and either terminal can be
assigned to any collection of devices that require two
separate buses. The SDI splitter does not affect the
operation of the control panel or the associated SDI
devices.
LEDs
The SDI splitter has three green LEDs (labeled PANEL
ACTIVE, FIRE ACTIVE, and BURG ACTIVE) that monitor
bus activity.
Power
The SDI splitter operates on power from the control
panel, but the DC current is limited to 550 mA for each
bus (FIRE and BURG), or enough power for two D1255
keypads; two D1255RB, D1256RB, or D1257RB
keypads; two D1260 keypads, or one D1265 keypad.
An external power supply, connected with a common
ground, is required to provide power for devices that
exceed the 550 mA limit.
A total of up to 32 SDI devices can connect to the
output buses. A fault to the power or data connections
of one bus does not affect the other bus.
2 | ICP-SDI-9114 SDI Splitter
Certifications and approvals
Region Certification
USA UL UOXX: Control Unit Accessories, System
(UL864, 9th edition)
CSFM 7167-1615:0243 7167 -- CONTROL
UNIT (HOUSEHOLD)
CSFM 7165-1615:0242 7165 -- FIRE ALARM
CONTROL UNIT (COMMERCIAL)
CSFM 7165-1615:0238 7165 -- FIRE ALARM
CONTROL UNIT (COMMERCIAL)
CSFM 7165-1615:0119 7165 -- FIRE ALARM
CONTROL UNIT (COMMERCIAL)
CSFM 7167-1615:0239 7167 -- CONTROL
UNIT (HOUSEHOLD)
FDNY-
6174
CoA
Installation/configuration notes
Compatible Control Panels
• B9512G/B9512G-E
• B8512G/B8512G-E
• D9412GV4/D7412GV4/D7212GV4
• D9412GV3/D7412GV3/D7212GV3
• D9412GV2/D7412GV2/D7212GV2
1
The D7212GV4, D7212GV3, and D7212GV2 are not
1
1
1
listed for commercial fire applications.
• D9124 Fire Alarm Control Panel
Mounting Considerations
Parts included
Quant. Component
1 SDI splitter
1 Hardware pack
1 Literature pack
Technical specifications
Environmental Considerations
Relative Humidity: 93% maximum, non‑condensing
Temperature (operating): 0°C to +50°C (+32°F to +122°F)
Mechanical Properties
Dimensions (H x W x D): 127 mm x 74 mm x 25.4 mm
(5 in. x 2.9 in. x 1 in.)
Weight: 0.13 kg (4.6 oz)
Outputs
Current (BURG bus): 550 mA maximum from control panel
Current (FIRE bus): 550 mA maximum from control panel
Power Requirements
Current: 30 mA maximum
Voltage (supply): 12.0 VDC nominal
Notice
UL requires that the SDI splitter be mounted in
the same enclosure with the control panel, or in a
separate enclosure in the same room within 20 ft
(6.0 m) of the control panel and connected by
conduit.
Wiring Considerations
Wiring from the control panel to SDI splitter should be
0.8 mm (22 AWG) to 2.0 mm (12 AWG) wire with a
maximum wire length of 6.0 m (20 ft). The maximum
impedance of the wire from the control panel to the
SDI splitter must not exceed 1 Ω.
The maximum total wiring length for any single bus is
3048 m (10,000 ft). To determine the maximum
impedance, maximum wire length and appropriate
wire gauge for wiring from the SDI splitter to the SDI
devices, refer to the specifications for each SDI
device.
Trademarks
All hardware and software product names used in this
document are likely to be registered trademarks and
must be treated accordingly.
Ordering information
ICP-SDI-9114 SDI Splitter
Provides the ability to set up two independent SDI
buses from a single SDI connection on the control
panel.
Order number ICP-SDI-9114