Bosch 9707063000 User Manual

GOOD.BEETER>BOSCH
Installation / Operating Instructions
BOSCH 13P & 16P
Continuous Flow Gas Water Heater
1 Main Cover 5 Cold Water Inlet 2 Inspection Window 6 Hot Water Supply 3 Access Panel 7 Mounting Point 4 Gas Inlet 8 Horizontal Flue A-D Dimensions on page 2 Fig 3
Fig. 1
This appliance must be installed in accordance with the manufacturer’s installation instructions,
AG 601, NZ 5261, AS/NZS 3500.4.2
and all Local Water, Building and Gas fitting regulations
To be installed and serviced only by an authorised person
This appliance is not suitable for use as a pool heater
The “authorised installing person” is responsible for :
1. Correct commissioning of this appliance.
2. Ensure unit performs to the specifications stated on the rating label.
3.. Demonstrate operation of unit to customer before leaving.
4. Hand these instructions to customer.
Failure to install this appliance in accordance with these installation instructions may
void warranty
In the interest of continued product improvement, Bosch reserves ther right to alter the specifications
9 708 069 951 Page1
without notice.
25/10/2011
Installation
Install only on an external wall, as close as possible to the most frequently used hot tap. Use a heat shield (accessory item part number 9 708 061 400) if the unit is to be installed on a combustible surface. Allow minimum air gap of 10 mm between the flue and the heat shield, (refer figure 2).
Ensure that the flue terminal is clear of any combustible material, and avoid installation in a marine environment.
Install the appliance such that the base of the appliance is not more than 1.3 metres and not less than 0.5 meters from the ground, and allow for easy access to service heater.
5
Secure heater to wall using two 10g X
Locate head of screw in the key hole of the top mounting bracket.
/
hex head wood screws (Ramset 610041 or similar).
16
Appl iance Dimensi ons
A B C D
13P 405 mm845 mm533 mm240
16P 460 mm936 mm550 mm240
Figur e 3
mm
mm
Pipe Connections Refer to Fig. 1 for locations
Hot and Cold water ½" male Natural gas ¾" female L.P. gas ½" male
A gas cock must be installed in the gas supply line with provision to disconnect the appliance. Install gate valve or full flow ball valve (fixed mechanism type) in cold water supply.
A non return valve must not be fitted. For example duo valve
We recommend that all hot water pipes be lagged if the runs are long or exposed, and water-proof lagging should be used on all external hot water pipes. If the water supply pressure exceeds 80% of the specified maximum, install a pressure limiting valve. If installing a pressure limiting valve fit a cold expansion valve between the limiting valve and the appliance. PLV = 500kPa Cold expansion = 700kPa
Refer to AG 601 and AS3500.1 for the relevant pipe size.
NOTE: Service calls for incorrect pipe sizing will NOT be covered under warranty.
Water Filter
If sludge or foreign matter is or may be present in the water supply, it is recommended that a suitable filter be incorporated in the water supply line to the heater. All pipes should be well flushed before connection is made. A water filter/strainer is installed in the inlet of the brass water valve inside the appliance.
9 708 069 951
25/10/2011
Page2
Characteristic Data
Bosch 13P Bosch 16P
Pilot orifice diameter mm NG 0.30 0.30
LP 0.19 0.19
TG & TLP 0.56 N/A
Burner Injector Diameter mm NG 1.25 1.30
LP 0.79 0.75
TG & TLP 2.25 N/A Minimum water pressure for maximum water flow 100 kPa 150 kPa Maximum water flow litres per minute @ 25°C rise 13 16 Nominal hourly gas consumption Mj/h 100 130 Burner Pressure kPa NG 0.87 0.71
LPG 2.60 2.60
Refer to rating label located on the bottom right hand corner of the back panel for additional data.
Freezing
Weather
In areas where the atmospheric temperature may drop below 0°C, the heater must be drained to prevent damage by expansion of freezing water. For appliances installed in locations where the temperature falls below zero ° C for brief periods
, the installation of an EXOGEL expansion valve, part number H 707 060 151, will minimise the possibility of damage to the appliance.
This water heater MUST NOT
temperature remains below 0°C for extended periods.
be installed in areas where the
Hot Water
Conversion and Spare Parts
For spare parts or conversion of the heater to operate on a different gas that for which it was originally manufactured, please contact your local gas authority, authorised service agent or the manufacturer
Maintenance
We recommend that the appliance be inspected and cleaned by an authorised person periodically, depending upon the frequency and duration of its operation, but never less than once a year.
1 Meter minimum
Exogel
9 708 069 951 Page3
25/10/2011
Operating instructions
Procedure to light the appliance.
Fig. 4
To ensure that the water, at maximum water flow, will be of adequate temperature for sanitary purposes ( approx 40°C ), the appliance must be
installation.
When hotter water is required, ie dishwashing, simply reduce the flow of water at the tap and up to 60°C water will be delivered.
Refer to the commissioning section for adjustment details.
-
Warning
If the pilot light is extinguished, wait 5 minutes before attempting to relight the appliance. If the appliance does not operate, burns with yellow flame, leaks water or a gas smell is evident, turn off and contact the local gas authority, the manufacturer or an authorised service person. When attempting to light the appliance ensure
CAUTION:
It is recommended that for sanitary fixtures used primarily for the purpose of personal hygiene that a temperature control device be fitted (such as a tempering valve) as per AS.3498.
adjusted by the plumber at the time of
that all hot water taps are turned off.
9 708 069 951
25/10/2011
Page4