Maximum flow, corresponding to
a temperature increase of 25OC
Maximum inlet temperature °C808080
Temperature locked model available
(adjustable to deliver 50°C at tap)
Electrical circuit
Power supply voltageVAC230230230
Maximum power consumptionW100100100
Warranty Details (Domestic)
Parts and LabourYears333
Heat Exchanger onlyYears121212
OptiFlow Professional Internal modelsBosch Part Number
55°C set 12L/minute NG model7736502487
55°C set 12L/minute LPG model7736502488
50°C locked 12L/minute NG model7736502489
50°C locked 12L/minute LPG model7736502490
55°C set 16L/minute NG model7736502495
55°C set 16L/minute LPG model7736502496
50°C locked 16L/minute NG model7736502497
50°C locked 16L/minute LPG model7736502498
55°C set 20L/minute NG model7736502499
55°C set 20L/minute LPG model7736502500
50°C locked 20L/minute NG model7736502501
50°C locked 20L/minute LPG model7736502502
l/min2.02.02.0
l/min12.016.020.0
YesYesYes
Measurements (mm)ABC
12L model300570170
16L model364570175
20L model364570175
Connections
WaterGas
ColdHotNGLPG
15mm (1/2”) 15mm (1/2”) 15mm (1/2”) 15mm (1/2”)
Page 3
OptiFlow Professional flue install instructions | 3
What you need to know
WHICH TYPE OF FLUE TO USE
Bosch OptiFlow Professional flue must be used with these appliances. Any installations with the incorrect flue will not
be approved and could pose a risk.
The flue used for the Bosch OptiFlow Professional is a 60/100 Ø coaxial flue. This flue allows the appliance to draw air
in from outside, and expel flue gas back outside, making the appliance room sealed.
THE FLUE MATERIALS USED
Inner and outer layers are extruded aluminium. The outer layer is painted white.
CUTTING THE FLUE TO LENGTH
Flue extensions can be cut to length. Care should be taken to remove burrs to maintain the integrity of the seal to the
adjoining fitting.
STRAIGHT FLUE LENGTH TABLE
12/16L20L
Maximum vertical flue length12m8m
Maximum horizontal flue length10m6m
REDUCTION IN LENGTHS FOR BENDS
For every bend added to a flue configuration, the maximum acceptable flue length will reduce by the amount shown below
Flue Bend reduction Table
45° Bend1m
90° Bend2m
CONDENSATE TRAPS
Condensate is more likely to form in longer lengths of flue, or when outside ambient air temperature is low. The table
below shows the length and temperature combinations when a condensate trap should be used.
Condensate trap kits are supplied with all components required for installation.
10m
FLUE LENGTH
9m
8m
7m
6m
5m
4m
3m
2m
1m
-100C-50C 00C 50C 100C 150C 200C250C
3
8
LOWEST OUTSIDE AIR TEMPERATURE
Page 4
4 | OptiFlow Professional flue install instructions
Bosch OptiFlow Professional
Flue Configurations
Selecting the Right Flue
1 Map your flue configuration.
2 Check that the configuration, including bends, is within the
maximum flue limits.
3 Calculate whether a condensate trap is required using the
table on page 3.
4 Choose the flue kit that best suits your application. (The kit
includes the appliance adaptor and terminal.)
5 Add any flue lengths, bends, or condensate traps required for
your configuration.
6 Place your order using the Bosch part numbers shown below.
Vertical Flue Kit
Part No: 7716050071
Telescopic Horizontal Flue Kit
Part No: 7716050063
Fixed Length Horizontal Flue Kit
Part No: 7716050064
Highline Horizontal Flue Kit
Part No: 7736995083
Page 5
OptiFlow Professional flue install instructions | 5
90° elbow
Part No: 7736995079
Straight Pipe 350 mm
Part No: 7736995059
45° elbow
Part No: 7736995071
Straight Pipe 750 mm
Part No: 7736995063
Straight Pipe 1500 mm
Part No: 7736995067
Vertical Condensate Collector
Part No: 7736995089
Horizontal Condensate Collector
Part No: 7736995087
Page 6
6 | OptiFlow Professional flue install instructions
A BCD
A Standard vertical flue – Minimum length
Components
Part Numbers 7716050071
Number of components required
Ø60/1001.4m1
B Standard vertical flue
Components
Part Numbers 7716050071
Maximum length and number of components required
Ø60
/ 100
12m (12/16L)
8m (20L)
1
7736995059 (350mm)
7736995063 (750mm)
7736995067 (1500mm)
Up to 10.6m (12/16L)
Up to 8.6m (20L)
C Standard horizontal flue assembly
Components
Part Numbers
Maximum length and number of components required
Ø60/100
10m (12/16L)
6m (20L)
7716050064 (fixed length kit) or
7716050063 (telescopic kit)
1
7736995089
1 (if
required)
7736995059 (350mm)
7736995063 (750mm)
7736995067 (1500mm)
Up to 9.5m (12/16L)
Up to 5.5m (20L)
D Standard horizontal flue assembly with 90°
Components
Part Numbers
Maximum length and number of components required
Ø60
/ 100
8m (12/16L)
4m (20L)
7716050064 (Fixed length kit) or
7716050063 (Telescopic kit)
11
7736995079
7736995059 (350mm)
7736995063 (750mm)
7736995067 (1500mm)
Up to 7.5m (12/16L)
Up to 3.5m (20L)
Page 7
A BCD
A Extension flue horizontal and upwards
Components
Part Numbers 77369950837736995079
Maximum length and number of components required
Ø60 / 100
8m (12/16L)
4m (20L)
12
B Extension flue horizontal and upwards
Components
Part Numbers 77369950837736995079
Maximum length and number of components required
Ø60 / 100
10m (12/16L)
6m (20L)
11
C Vertical flue – two 45° bends
Components
Part Numbers 77160500717736995071
Maximum length and number of components required
Ø60/100
10m (12/16L)
6m (20L)
11 (2 x bends per pack)
7736995059 (350mm)
7736995063 (750mm)
7736995067 (1500mm)
Up to 7.5m (12/16L)
Up to 3.5m (20L)
7736995067 (350mm)
7736995063 (750mm)
7736995067 (1500mm)
Up to 9.5m (12/16L)
Up to 5.5m (20L)
7736995067 (350mm)
7736995063 (750mm)
7736995067 (1500mm)
Up to 8.6m (12/16L)
Up to 4.6m (20L)
7736995089
1 (if required)
7736995089
1 (if required)
7736995089
1 (if required)
D Vertical flue – two 90° bends
Components
Part Numbers 7716500717736995079
Maximum length and number of components required
Ø60 /
100
8m (12/16L)
4m (20L)
12
7736995067 (350mm)
7736995063 (750mm)
7736995067 (1500mm)
Up to 7.5m (12/16L)
Up to 3.5m (20L)
77369950877736995089
1 (if required)1 (if required)
Page 8
Robert Bosch Australia Pty. Ltd.
1555 Centre Rd
Clayton Victoria 3168
Sales Hotline: 1300 30 70 37
Sales Fax: 1300 30 70 38
bosch-climate.com.au
Technical data subject to modification without notice.
Printed in Australia. Any color variations are due to the limitations of the printing process.
Printed on 100% chlorine-free bleached cellulose manufactured in an environmentally friendly process.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.