Bohn BBL10 Service Manual

Replaces BN-RITB, January 2004
REACHIN UNIT COOLERS
Technical Guide
Models TA • TL • C • VA • BBM • BBL • KMK • RAMK • BTO • U
BNRITB
June 2009
www.thecoldstandard.com
TABLE OF CONTENTS
Model TA Thin Prole Air Defrost .......................................................................................................................... 3
Model TL Thin Prole Electric Defrost .................................................................................................................4
Model C High Prole ................................................................................................................................................. 5
Model VA Vee-Aire ...................................................................................................................................................... 6
Models BBM/BBL Back Bar....................................................................................................................................... 7
Model KMK Kompact Mullion ................................................................................................................................ 8
Model RAMK Reverse Air Flow Kompact Mullion ........................................................................................... 9
Model BTO Twin Flow .............................................................................................................................................10
Model U Dual Aire Standard Coil ........................................................................................................................11
In order to ensure our products function reliably even in corrosive environments, Bohn oers coated coil options on many of our Reach-In products. These coatings provide superior protection in most common refrigeration environments. If you have a question about a specic application, please contact your Bohn representative.
E Solutions™ branded products and options are designed to exceed current energy and environmental standards. We have made a conscious commitment to developing environmentally innovative products that allow our customers to make energy ecient, eco-conscious choices. Products included in the E Solutions portfolio reduce costs, improve bottom lines, and enhance both equipment performance and service life. EC motors are an E Solutions option available on some models contained in this catalog. This oering reduces energy consumption and saves money.
©2009 Heatcraft Refrigeration Products, LLC
MODEL TA
Thin Profile Air Defrost Reach-In Unit Cooler
Features
• Textured aluminum cabinet
• Molded Lexan® guards and fans
• Drain tting mounted at 45-degree angle so drain can be run through back or bottom of refrigerator
• Expansion valve can be mounted inside the cabinet
• Stainless steel screws
• Motors are thermally protected and permanently lubricated
• Convenient, moistureproof motor plug
• Compact design! Does a big job in a small space
• Optional coated coil available (Model TAK) for enhanced protection in corrosive environments
• Internal junction box for electrical connection
• All models are UL listed for the US and Canada
• UL classied to NSF standards
• Sweat inlet connection standard to reduce leaks
(are connection available as a ship loose option)
Application
Model TA
refrigerator and makes the entire top shelf area usable. The attractive low silhouette makes the unit particularly desirable for display type refrigerators. It can also be used in back bars, under counter cabinets, or wherever space is at a premium.
For 35° to 45°F xtures at 10° to 15° TD applications with 16 hours maximum compressor run time per day.
is a thin prole unit which mounts in the top of a
Nomenclature
TA K 17 B G
Model Coil Option Model Size Electrical Code Vintage
Thin Prole Air Defrost
Blank = Standard K = Coated
10-55 A = 115/1/60
B = 208-230/ 1/60
Performance & Electrical Data
Model
TA(K)10 1,000 120 1 0.8 0.4 3/8 3/8 1/2 14 TA(K)13 1,300 170 2 1.6 0.8 3/8 3/8 1/2 17 TA(K)17 1,700 210 2 1.6 0.8 3/8 3/8 1/2 21 TA(K)23 2,300 330 3 2.4 1.2 3/8 3/8 1/2 28 TA(K)30 3,000 360 3 2.4 1.2 3/8 1/2 1/2 33
TA(K)43* 4,300 540 4 3.2 1.6 1/2 5/8 1/2 44 TA(K)55* 5,500 650 5 4.0 2.0 1/2 5/8 1/2 53
* Models 43 and 55 require an external equalized expansion valve
BTUH
10°F TD
CFM Qty.
Motor Data Connections (in.) Approx.
115/1/60
Total FLA
208-230/1/60
Total FLA
Coil Inlet
OD
SuctionIDDrain
OD
Ship Wt.
Physical & Dimensional Data
Model
TA(K)10 14-5/8 14 15/16 13-1/2 10-1/2 11-3/8 4-1/2 8-7/8 2-1/2 15/16 4-3/8 16-1/2 TA(K)13 18-5/8 14 15/16 13-1/2 10-1/8 10-1/4 4-1/2 8-3/8 9-1/2 15/16 4-3/8 20-1/2 TA(K)17 22-1/8 15 15/16 14-1/2 11-1/8 12 4-1/2 9-3/8 11-1/4 15/16 4-3/8 24 TA(K)23 29-3/4 15 15/16 14-1/2 13 20-7/8 4-1/2 10-3/4 10-1/4 15/16 4-3/8 31-5/8 TA(K)30 38-1/8 15 15/16 14-1/2 13 29-3/4 4-1/2 10-3/4 9-3/4 15/16 4-3/8 40 TA(K)43 51-1/2 15 15/16 14-1/2 13 48-3/4 4-1/2 10-3/4 13-1/4 15/16 4-3/8 53-3/8 TA(K)55 51-1/2 15 15/16 14-1/2 13 49 6-3/4 10-3/4 11 15/16 4-3/8 53-3/8
A B C D E F H J K L M W
Dimensions (in.)
(lbs.)
3
Model TL
Thin Profile Electric Defrost Reach-In Unit Cooler
Features
• Electric defrost ensures positive heat source
• Built-in fan delay allows coil to be chilled before returning to the normal cooling cycle
• Defrost terminates on coil temperature eliminating excessive defrost period
• Textured aluminum cabinet
• Molded Lexan® guard
• Knockouts provided on sides for electrical connections - opening in rear for coil connections
• Expansion valve can be mounted inside the cabinet
• Stainless steel screws
• Motors are thermally protected and permanently lubricated
• Internal junction box for electrical connection
• Plate type aluminum ns with full collars on expanded copper tubes
• Coils are dehydrated and sealed
• Easy to install and maintain
• All models UL listed for the US and Canada
• UL classied to NSF standards
• Sweat inlet connection to reduce leaks
(are connection available as a ship loose option)
Application
Model TL low temperature unit cooler has a completely
automatic defrost system. Mounted in the top of a refrigerator, its extremely compact cabinet makes it possible to utilize the entire top shelf area for storage. Having a normal operating range of 15°F to -20°F, this unit is ideally suited for such applications as commercial freezers, ice cream boxes and bakery freezers.
Nomenclature
TL 12 B G
Model Size Electrical Code Vintage
Thin Prole Electric Defrost
09-53 A = 115/1/60
B = 208-230/1/6
Performance & Electrical Data
BTUH 10˚F TD Motor Data Heater Data Connections (in.) Approx.
Model
TL09 1,050 900 110 1 0.8 0.4 475 4.1 2.1 3/8 3/8 1/2 14 TL12 1,380 1,200 210 2 1.6 0.8 600 5.2 2.6 3/8 1/2 1/2 19 TL16 1,780 1,600 210 2 1.6 0.8 700 6.1 3.0 3/8 1/2 1/2 23
TL21^ 2,400 2,100 240 1 1.0 0.5 1,100 9.6 4.8 3/8 1/2 1/2 24
TL28 3,200 2,800 335 3 - 1.2 1,430 - 5.7 3/8 1/2 1/2 27 TL35^* 4,000 3,500 420 2 - 1.0 1,600 - 7.0 1/2 5/8 1/2 38 TL53^* 6,100 5,300 595 3 - 1.5 1,950 - 8.5 1/2 7/8 1/2 53
^ Model available with EC motors * Models 35 and 53 require an external equalized expansion valve
20˚F
SST
-10˚F SST
CFM Qty.
115/1/60
Total FLA
208-230/1/60
Total FLA
Watts
115/1/60
Amps
208-230/1/60
Amps
Coil InletODSuctionIDDrain
OD
Ship Wt.
(lbs.)
Physical & Dimensional Data
Model
TL09 14-5/8 14 15/16 13-1/2 10-1/2 11-3/8 4-1/2 8-7/8 2-1/2 15/16 4-3/8 - 1 16-1/2 TL12 18-5/8 14 15/16 13-1/2 10-1/8 10-1/4 4-1/2 8-3/8 9-1/2 15/16 4-3/8 - 1 20-1/2 TL16 22-1/8 15 15/16 14-1/2 11-1/8 12 4-1/2 9-3/8 11-1/4 15/16 4-3/8 - 1 24 TL21 22-1/8 16-1/2 15/16 16-1/2 14-1/2 18-7/8 6-3/4 11-7/8 17-1/4 15/16 4-3/8 - 1-1/2 24 TL28 29-3/4 15 15/16 14-1/2 13 20-3/4 6-3/4 9-3/4 9-7/8 15/16 4-3/8 - 1 31-5/8 TL35 35-3/4 16-1/2 15/16 16-1/2 14-1/2 33-1/4 6-3/4 11-5/8 18-3/8 15/16 6 5-1/8 1-1/2 38-3/8 TL53 46-1/2 16-1/2 1-1/8 16-1/2 14-1/2 44 6-3/4 11-5/8 30-3/8 1-1/2 6 5-1/8 1-1/2 49-1/8
A B C D E F H J K L M N P W
Dimensions (in.)
Loading...