Bogen VAR1 Service Manual

VOICE-ACTIVATED RELAY VAR1
DESCRIPTION
The VAR1 Voice-Activated Relay is a DPDT relay device that is activated when an audio signal is detected at the microphone pre-amp or at 70V, 25V, or 600-ohm line level inputs. It has a number of useful applications, such as mut­ing a sound system in response to a microphone or tele­phone page, activation of accessory (security) equipment, or activation of a zone paging module.
INSTALLATION
Set input source switch on the top side of the unit to LINE if using one of the line inputs or to MIC if using a microphone.
Connect a power supply to the 12-24V DC jack on the top of the unit or to the + and - screw terminals. The Bogen model PRS40C power supply is recommended.
WIRING
Refer to the block diagrams and the sample wiring diagrams on the next page to wire the VAR1 for your application.
OPERATION
Sensitivity can be adjusted according to the needs of the application. Clockwise rotation of the control increases sensitivity. Do not over rotate the control or you may damage the trimpot.
The delay control is also adjustable in the field.The max­imum delay time is 25 seconds. Clockwise rotation of the control increases delay time.
Printed in Korea 0309 ©2003 Bogen Communications, Inc. 54-5934-01B Specifications subject to change without notice.
50 Spring Street, Ramsey, NJ 07446 U.S.A. 201-934-8500; FAX: 201-934-9832 www.bogen.com
SPECIFICATIONS
LINE INPUT
Impedance: 600 ohms Frequency Response: 100 Hz to 10 kHz 70V Input Impedance: 200k ohms Output Level: 400 m VRMS 25V Input Impedance: 75k ohms Output Level: 420 m VRMS
MIC PREAMP
Gain: 62 dB Sensitivity: 750 microvolts, rms for 1 VRMS out Distortion: <2% Frequency Response: 200 Hz to 10 kHz Output Signal-to-Noise Ratio: 55 dB VOX Sensitivity: 20 mV - 150 m VRMS
@ 600 ohms Line input Time Delay Range (approx.): 0.25 to 25 sec. Relay Contact Rating: 2 amps/30 VDC,
0.5 amp./120 VAC
SERVICE
There are no user serviceable components within the VAR1.The warranty may become void if the unit is serv- iced by other than an authorized Bogen service agency.
Contact the Bogen Applications Department if you have any questions concerning VAR1 applications.
VAR1 used with Classic Series amplifiers to mute music during
a telephone page (paging port without contact closure).
VAR1 used in a security system to activate an amplifier, CCTV, and light relay control.
VAR1 used with zone paging module.
VAR1 Block Diagram