Bogen BPA-60 Operation Manual

Specifications subject to change without notice.
© 2009 Bogen Communications, Inc.
All rights reserved. 54-5810-05C 1206
BPA60
Power Amplifier
Installation & Use Manual
Rated Output Power: 60 watts
Frequency Response: -2 dB, 20 Hz to 20 kHz
Input Sensitivity: High-impedance, 300mV; low-impedance balanced (with optional
transformer), 75mV
Hum and Noise: 85 dB below rated output
Output Loads: 8-ohm/25V, 16-ohm, 25V CT, 70V
Output Regulation: Better than 2 dB from no load to full load
Input Impedances: High-impedance, 50k ohms unbalanced; low-impedance, 600 ohms,
balanced (with optional transformer)
Lo-cut Filter: -10 dB at 100 Hz (switch-selectable)
Controls and Indicators: Front Panel — Illuminated on/off power switch
Rear Panel — Input level control, circuit breaker reset, lo-cut filter switch
Power Consumption: 120V AC, 60 Hz, 180W at full rated output
Thermal Emissions (full power): 204.9 BTU/hr.
Overload Protection: Transient protection diodes, electrical circuit breaker,
thermostat
Operating Temperature Range: -4° F to 131° F (-20° to +55° C) at rated output
Auxiliary Receptacle (not switched): Three-wire grounded*, 300W maximum, 2.5A (internally fused)
Dimensions: 15-1/4"W x 3-1/2"H x 8-1/4"D
Finish: Black
Product Weight: 17 lbs.
Approvals: Listed to UL Standard 60065 for US and Canada
Accessories: Model TL600, 600-ohm line-matching transformer;
Model TL100, 1:1 ratio transformer; Model RPK53 rack panel brackets
*This receptacle will be grounded only if the power amplifier has been grounded properly.
Technical
Specifications
NOTICE: Every effort was made to ensure that the information in this guide
was complete and accurate at the time of printing. However, information is subject to change.
WARNING: To reduce the risk of Fire or Electric Shock, Do Not Expose this
apparatus to rain or moisture.
Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases shall be placed on the apparatus.
WARNING: Only connect unit to AC mains outlet providing protective
earthing connection.
NOTE: Mains plug is used as disconnect device from the mains and shall
remain readily accessible and operable.
CAUTION: These servicing instructions are for use by qualified service per-
sonnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
CAUTION: DO NOT INSTALL OR PLACE THIS UNIT IN A BOOKCASE, BUILT-IN CABINET, OR IN ANOTHER CONFINED SPACE. ENSURE THE UNIT IS WELL VENTILATED. TO PREVENT THE RISK OF SHOCK OR FIRE HAZARD DUE TO OVER-HEATING, ENSURE THAT CURTAINS AND ANY OTHER MATERIALS DO NOT OBSTRUCT THE VENTILATION VENTS.
Always follow these basic safety precautions when installing and using the unit:
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean unit with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two
blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong.
The wide blade, or the third prong, are provided for your safety. If the provided plug does not fit into your
outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Unplug this apparatus during lightning storms or when not used for long periods of time.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been
damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate
normally, or has been dropped.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO PREVENT THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE ANY FRONT/BACK COVERS OR PANELS. NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED PERSONNEL.
The exclamation point within an equi­lateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions.
The lightning flash with arrowhead sym­bol, within an equilateral triangle, is in­tended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.