Bogen ASUG1DK User Manual

Amplified Speakers Models AS1, ASUG1(DK), and ASWG1(DK)
Installation and Use Manual
Description
Bogen’s self-amplified ceiling speakers are 8-inch, cone-type loudspeakers, complete with built-in amplifier and volume control knob.
Installation Instructions for ASUG1(DK) and ASWG1(DK)
Note: Do not mount the speaker near noise generating equipment (fans, motors, etc.) and do not use where a normal conversation cannot be conducted.
TB8 and RE84 Installation
1. Place ceiling tile with the finished side facing up over a large trash can (to provide support and save cleanup time).
2. Cut hole in the center of the ceiling tile, using the raw speak­er as a guide.
3. Bend (4) horseshoe tabs upward on tile bridge.
4. Position the tile bridge on the unfinished side of the ceiling tile and bend (4) locator tabs into tile opening to prevent sliding.
5. Slip tie-off tabs (2) through RE84 tie-off tab slots until they click into place and secure customer-supplied “tie-off” wire to tab.
6. Punch out knockout in the RE84. Install listed metallic enclo­sure entry fitting to knockout to accommodate plenum cable or plenum. Whip and feed cable or whip through the knock­out.
7. Install RE84 to tile bridge by orienting horseshoe tab slots (4) over horseshoe tabs (4) of bridge.
8. With pliers, twist horseshoe tabs (4) of tile bridge 1/2 turn, securing enclosure to bridge.
9. Screw the Ceiling Speaker assembly to the RE84 using (4) 8-32 screws provided with the Ceiling Speaker assembly, sandwiching the TB8 and ceiling tile in between. The screws must go through the TB8 clearance holes as shown. (Screws anchor into the RE84.)
© 2004 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-5850-02C 0804
Model Style
Power
Requirements
Power Rating
Mounting Accessories
AS1
Unmounted Cone Speaker with 1W Amplifier and Volume Control
1 CU
(50 mA)
1W
Grilles: CG8A, CG8AW, SG8W, PG8A, PG8U, PG8W
ASUG1, ASWG1
AS1 Mounted onto Steel Ceiling Grille (PG8U or PG8W) with Fixed, Volume Control Knob
TB8, RE84, MR8
ASUG1DK, ASWG1DK
AS1 Mounted onto Steel Ceiling Grille (PG8U or PG8W) & Detachable Volume Control Knob
50 Spring Street, Ramsey, NJ 07446, U.S.A. Tel. 201-934-8500, Fax: 201-934-9832, www.bogen.com
Limited Warranty
The AS1, ASUG1, ASWG1, ASUG1DK, and ASWG1DK are warranted to be free from defects in material or workmanship for two (2) years from the date of sale to the original purchaser. Any part of the product covered by this warranty that, with normal installation and use, becomes defective will be repaired or replaced by Bogen, at our option, provided the product is shipped insured and prepaid to: Bogen Factory Service Department, 50 Spring Street, Ramsey, NJ 07446, USA. The product will be returned to you freight prepaid. This warranty does not extend to any of our products that have been subjected to abuse, misuse, improper storage, neglect, accident, improper installation or have been modified or repaired or altered in any manner whatsoever, or where the serial number or date code has been removed or defaced.
THE FOREGOING LIMITED WARRANTY IS BOGEN'S SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW. Bogen's liability arising out of the manufacture, sale or supplying
of products or their use or disposition, whether based upon warranty, contract, tort or otherwise, shall be limited to the price of the prod­uct. In no event shall Bogen be liable for special, incidental or consequential damages (including, but not limited to, loss of profits, loss of data or loss of use damages) arising out of the manufacture, sale or supplying of products, even if Bogen has been advised of the possibility of such damages or losses. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from State to State.
Products that are out of warranty will also be repaired by the Bogen Factory Service Department -- same address as above or call 201-934-8500. The parts and labor involved in these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department. All shipping charges in addition to parts and labor charges will be at the owner's expense. All returns require a Return Authorization number.
08/10/2004
TB8 Only Installation
1. Place ceiling tile with the finished side facing up over a large trash can (to provide support and save cleanup time).
2. Cut hole in the center of the ceiling tile, using the raw speak­er as a guide.
3. Position the tile bridge on the unfinished side of the ceiling tile and bend (4) locator tabs into tile opening to prevent sliding.
4. Install Ceiling Speaker assembly using (4) 8-32 screws and the threaded holes of the tile bridge as shown. (Screws are provided with Ceiling Speaker assembly.)
Electrical Connections and Adjustments
Power (24V DC) and audio are supplied to each speaker via four screw terminals. When two or more speakers are used in a single paging station, wire all audio and power supply connec­tions in parallel.
Power supply connections are made at the screw terminals marked "+" and "-". Audio connections are made at the screw terminals marked TIP and RING. The speaker power input is not polarity sensitive and will also work properly if the "+" and "-" connections are reversed.
A volume control knob is provided to adjust the volume of the speaker. The knob is detachable on the ASUG1DK and ASWG1DK models to prevent tampering with the volume control.