Boekel Scientific 145951-2 User Manual

5 (1)
Boekel Scientific 145951-2 User Manual

Illuminated Tissue Flotation Bath

Model

145702

145702-2

145951

145951-2

Operating Instructions

N2400313 Rev. 0 8/09

TABLE OF CONTENTS

Page

1.

Safety ..............................................................................................................................

2

2.

Product Information........................................................................................................

2

3.

Assembly.........................................................................................................................

3

3.1

Unpacking...................................................................................................................

3

3.2

Installation...................................................................................................................

3

4.

Operation.........................................................................................................................

3

4.1

Controls and Indicator Lamp (see figure 1)................................................................

3

4.2

Filling the Bath ...........................................................................................................

4

4.3

Setting the Temperature..............................................................................................

4

4.4Setting the High Temperature Alarm………………………………………………...5

4.5

Illuminating the Bath ..................................................................................................

5

4.6

Dryer Block - Not included with Model 145702 or 145702-2 ..................................

5

4.7

Orienter Block - Not included with Model 145702 or 145702-2 ...............................

5

5.

Fault Diagnosis ..............................................................................................................

6

6.

Accessories ....................................................................................................................

6

7.

Technical Specifications ................................................................................................

6

8.

Maintenance and Service ...............................................................................................

7

8.1

Cleaning ......................................................................................................................

7

8.2

Replacement of Fuses .................................................................................................

7

9.

Warranty .........................................................................................................................

7

10.

Service............................................................................................................................

7

N2400313 Rev. 0 8/09

1

1. Safety

The following symbols marked on the equipment mean:

Caution: Read these operating instructions fully before use and pay particular attention to sections containing this symbol.

Attention: Suivre attentivement les instructions avant l’usage et prêtez une attention particulière aux sections comportant ce symbole.

Caution: Surfaces can become hot during use.

Attention: Les surfaces peuvent devenir brûlantes pendent l’usage.

Always observe the following safety precautions:

Use only as specified by the operating instructions or the intrinsic protection may be impaired. After transport or storage in humid conditions, dry out the unit before connecting it to the supply voltage. During drying out the intrinsic protection may be impaired.

Connect only to a power supply with a voltage corresponding to that on the serial number label.

Connect only to a power supply that provides a safety ground terminal.

Water should be placed only in the glass dish. Filling the chamber without the glass dish may damage the bath and pose an electrical hazard.

Before moving, disconnect at the power supply socket.

Do not touch surfaces that become hot during high temperature operation.

Ensure that the operating temperature is less than the maximum operating temperature of your sample material.

Ensure that the power switch is easily accessible during use.

If liquid is spilled inside the unit, disconnect it from the power supply and have it checked by a competent person.

It is the user’s responsibility to carry out appropriate decontamination if hazardous material is spilled on or inside the equipment.

This product must be used with an UL Listed / CSA Certified power supply cord set.

The responsible body shall be made aware that, if the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

2.Product Information

The Boekel Illuminated Tissue Floatation Bath is designed to help eliminate wrinkles and distortions in tissue specimens as they are being mounted on glass microscope slides. The Tissue Floatation Bath provides a temperature controlled glass dish water bath for specimen preparation, a digital temperature readout for determining bath temperature and LED illumination the bath and tissue specimen. The glass dish water bath has two molded side handles allowing easy removal for cleaning and quick water change.

N2400313 Rev. 0 8/09

2