Blue-White A-100N, A-100NC, A-100NS, A-100NA, A-100NF Operating Manual

...
®
MODEL A-100N
Peristaltic Injector Pump
Operating Manual
Models A-100NA, A-100NC, A-100NS, A-100NF, A-100NX
5300 Business Drive
Huntington Beach, CA 92649
Phone: 714-893-8529 FAX: 714-894-9492
E mail: sales@blue-white.com or techsupport@blue-white.com
Website: www.blue-white.com
Blue-White
Industries, Ltd.
R
A-100NPage 2
TABLE OF CONTENTS
1.....Introduction....................................................................................3
2.....Specifications .......................... ............................ ............................3
3.....Features .................... ........................................................ ..............3
4.....Unpacking .. ............................ .......................................... ..............4
5.....Installation................ ............................ ............................ ..............4
5.1..Mounting location ............. .......................................... ..............4
5.2..Optional circuit board signal connection installation... ..............6
5.3..Input power connections ............................................. ..............8
5.4..How to install the tubing and fittings............. ............................10
6.....How to adjust the output ..................... ..........................................11
6.1..Fixed cycle timer models .............................. ............................11
6.2..Variable speed model ........ ........................................................11
6.3..TFD - Tube Failures Detection system ........................ ..............12
6.4..FVS - Flow verification System .................................. ..............12
7.....How to maintain the Pump.... ............................ ............................14
7.1..Routine inspection and cleaning...... ............................ ..............14
7.2..How to clean and lubricate the Pump ........................................14
7.3..How to replace the pump tube ..................................... ..............15
Replacement parts drawing... .......................................... ..............16
Replacement parts list............ ............................ ............................17
Warranty information............ .......................................... ..............18
Authorized service centers..... .......................................... ..............19
A-100N Page 3
1.0 Introduction
Congratulations on purchasing the A-100N Peristaltic Metering Pump. The A-100N is designed to inject chemicals into piping systems. The pump has been tested by NSF International for use with 12 ½% Sodium Hypochlorite. This manual covers the following feed rate adjustment mechanisms:
1. Fixed Cycle Timer - (Models A-100NA, A-100NC, A-100NS) The fixed speed pumping mechanism is turned on and off by an electronic timer. The total cycle time is factory set. The on-time cycle is adjustable from 5% through 100% of the total cycle time. Model A-100NA has a 1 minute cycle with a 60 second adjustable on-time. Model A-100NC has a 5 second cycle with a 5 second adjustable on-time. Model A-100NS (ideal for spa and hot tub chlorination) has a 1 minute cycle with a 6 second adjustable on-time. (Custom cycles are available from the factory).
2. Variable Speed Controller - (Model A-100NF) The speed of the pumping mechanism is adjustable from 5% through 100%.
3. Fixed Feed Rate - (Model A-100NX) No adjustment control.
2.0 Specifications
Maximum Working Pressure 100 psig / 6.9 bar (most models)
o o
Maximum Fluid Temperature 130 F / 54 C
o o
Ambient Temperature Range 14 to 110 F / -10 to 43 C Duty Cycle Continuous Maximum Solids 50% by volume Maximum Viscosity 5,000 Centipoise Maximum Suction Lift up to 30 ft. water Power Requirements 108/130Vac 60Hz 80 Watts,
208/250Vac 50Hz 40 Watts, 208/250Vac 60Hz 45 Watts
Dimensions 6-1/8” H x 10-1/8” W x 9” D Weight 8 lb.
3.0 Features
!
Peristaltic Pump Tube does not require valves.
!
Self priming under maximum pressure. Cannot vapor lock.
!
High outlet pressure capability of 100 psig (most models).
!
High inlet suction lift capability of 30 feet.
!
Patented Tube Failure Detection (TFD) system.
!
Patented pump tube assembly design.
!
Includes Flow Verification System (FVS) - sensor sold separately.
!
Open collector (sinking 50mA max) alarm output. (30V DC max)
!
Corrosion proof Valox housing.
!
Tamper resistant electronic control panel cover.
5.0 Installation
Note: All diagrams are strictly for guideline purposes only. Always consult an expert before installing the pump into specialized systems. The pump should be serviced by qualified persons only.
5.1 Mounting Location
Choose an area located near the chemical supply tank, chemical injection point and electrical supply. Although the pump is designed to withstand outdoor conditions, a cool, dry, well ventilated location is recommended. Install the pump where it can be easily serviced.
!
Mount the pump to a secure surface or wall using the enclosed hardware. Wall mount to a solid surface only. Mounting to drywall with anchors is not recommended.
!
Mount the pump close to the injection point. Keep the outlet (discharge) tubing as short as possible. Longer tubing increases the back pressure at the pump tube.
!
Your solution tank should be sturdy. Keep the tank covered to reduce fumes. Do not mount the pump directly over your tank. Chemical fumes may damage the unit. Mount the pump off to the side or at a lower level than the chemical container.
!
Mounting the pump lower than the chemical container will gravity feed the chemical into the pump. This “flooded suction” installation will reduce output error due to increased suction lift. You must install a shut-off valve, pinch clamp or other means to halt the gravity feed to the pump during servicing.
!
Be sure your installation does not constitute a cross connection with the
Page 4
CAUTION: Proper eye and skin protection must be
worn when installing and servicing the pump.
CAUTION: Proper eye and skin protection must be
worn when installing and servicing the pump.
4.0 Unpacking
Your pump package should contain the following: 1 - Injector pump with 2 pump tube assemblies 1 - suction tube strainer 1 - ceramic tubing weight 1 - 5’ Length of clear PVC suction tubing 1 - 5’ Length of opaque LLDPE discharge tubing 1 - Injection fitting with internal back-flow check valve 1 - Mounting hardware kit
A-100N
Page 5
Floor Mount
Wall Mount
7-3/8”
7-5/8”
3-1/2”
8-3/16”
Drill .156 Dia. (5/32)
For Self-Tap Screw
#10 X 1” Phillips Steel
4 Places
Drill .156 Dia. (5/32)
For Self-Tap Screw
#10 X 1” Phillips Steel
2 Places
INJECTOR MOUNTING
Note: For wall-mounting, drill & thread into solid wood only.
TYPICAL INSTALLATION
R
Suction
Tube
Chemical Container with cover
Discharge
Tube
Strainer
Ceramic Weight
Injection / Check valve with 1/4” and 1/2” male pipe threads. Mount in upward position to prevent trapped gasses in the injection fitting.
Wall or shelf mount away from the top of the solution tank. Chemical fumes can damage the unit.
PARTS LOCATOR DRAWING
* Slide both top & bottom clamps to the left only far enough to open the control cover.
9
8
3
Control
Control Cover
Pumphead
Enclosure
Rear Plate
Pumphead Cover
6.0
Pumptube Assembly
Rotor Assembly
9
8
1
Slide Clamps*
A-100N
0%
100%
50%
75%
I
O
25%
ON OFF
BLUE-WHITEINDUSTRIES
L
I
A
T
U
Y
Q
P
T
R
C
O
U
D
A-100N
0%
100%
50%
75%
I
O
25%
ON OFF
A-100N
Page 6 A-100N
1/2” DIAMETER KNOCKOUT
LIQUID-TIGHT CONNECTOR
5.2 Optional circuit board signal connection installation - The
pump includes three optional external signal connections:
!
!
!
FVS - FLOW VERIFICATION SENSOR INPUT Accepts a pulse signal from an optional Blue-White sensor confirming that fluid is passing through the pump. Triggers and alarm output if fluid is not detected. AL - ALARM OPEN COLLECTOR OUTPUT The output (purple wire) sinks to DC ground when an alarm condition exists. 6-30Vdc collector voltage. 50mAdc maximum sinking current. MA - MOTOR ACTIVE OPEN COLLECTOR OUTPUT The output (brown wire) sinks to DC ground when the motor is de­energized. 6-30Vdc collector voltage. 50mAdc maximum sinking current.
All signal wires must be connected to the circuit board, located inside the pump enclosure, using connector plug wiring assemblies. A liquid-tight connector must be installed in the pump enclosure wall and the signal wires passed through the liquid-tight connector and secured. See pages 8 & 9 for wiring details.
1. Remove the rear enclosure panel.
2. Remove knock-out using a screwdriver.
3. Trim edge with a knife and remove sharp edges.
4. Install the provided liquid-tight connector.
5. Connect the connector plug to the circuit board.