Bloomfield 8752 User Manual

Model 8752 Brewer
with optional
8900-Series Decanters
605
OWNERS MANUAL
for
INTEGRITY™
5-WARMER
MODEL:
8752
8752KFT
Includes:
Installation
Operation
Use & Care
Servicing Instructions
PRINTED IN UNITED STATES OF AMERICA
p/n 70988 Rev. B ECN-12887 M605 050617 cps
WARRANTY STATEMENT
All electrical equipment manufactured by BLOOMFIELD INDUSTRIES is warranted against defects in materials and workmanship for a period of one year from the date of original installation or eighteen (18) months from the date of shipment from our factory, whichever comes first, and is for the benefit of the original purchaser, except that: a. airpots carry a 30 day parts warranty only. b. dispensers; i.e., tea and coffee carry a 90 days parts warranty only, excludes decanters.
THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXCLUDED.
BLOOMFIELD INDUSTRIES DIVISION / SPECIALTY EQUIPMENT MANUFACTURING CORPORATION SHALL NOT BE LIABLE FOR INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY CAUSE WHATSOEVER.
This warranty is void if it is determined that upon inspection by an Authorized Service Agency that the equipment has bee n modified, misused, misapplied, improperly installed, or damaged in transit or by fire, flood or act of God.
SERVICE POLICY AND PROCEDURE GUIDE
ADDITIONAL WARRANTY EXCLUSIONS
1. Resetting of safety thermostats, circuit breakers, overload protectors, or fuse replacements unless warranted conditions are the cause.
2. All problems due to operation at voltages other than specified on equipment nameplates; conversion to correct voltage must be the customer’s responsibility.
3. All problems due to electrical connections not made in accordance with electrical code requirements and wiring diagrams supplied with the equipment.
4. Replacement of items subject to normal wear, to include such items as knobs and light bulbs. Normal maintenance
functions including adjustment of thermostats, microswitches,
and replacement of fuses and indicating lights are not
covered under warranty.
5. All problems due to inadequate water supply, such as
fluctuating, or high or low water pressure.
6. All problems due to mineral/calcium deposits, or
contamination from chlorides/chlorines. De-liming is considered a preventative maintenance function and is not covered by warranty.
It also does not apply if the serial nameplate has been removed or unauthorized service personnel perfor m service. The prices charged by Bloomfield Industries for its products are based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to the repair of defects without charge by a Bloomfield Industries Authorized Service Agency or one of its sub-agencies. This service will be provided on customer’s premises for non-portable models. Portable models (a device with a cord and plug) must be taken or shipped to the closest Authorized Service Agency, transportation charges prepaid, for services.
In addition to restrictions contained in this warranty, specific limitations are shown below (Additional W arranty Exclusions). Bloomfield Industries Authorized Service Agencies are located in principal cities.
This warranty is valid in the United States and void elsewhere. Please consult your classified telephone directory or your food service equipment dealer; or, for information and other details concerning warranty, write to:
Phone: (888) 492-2782 Fax: (888) 492-2783
7. Full use, care and maintenance instructions are supplied with each machine. Those miscellaneous adjustments noted are customer responsibility. Proper attention will prolong the life of the machine.
8. Travel mileage is limited to sixty (60) miles from an authorized Service Agency or one of its sub-agencies.
9. All labor shall be performed during normal working hours. Overtime premium shall be charged to the customer.
10. All genuine Bloomfield replacement parts are warranted for ninety (90) days from date of purchase on non­ warranted equipment. Any use of non-genuine Bloomfield parts completely voids any warranty.
11. Installation, labor and job check-out are not considered warranty.
12. Charges incurred by delays, waiting time or operating restrictions that hinder the service technicians ability to perform services are not covered by warranty. This includes institutional and correctional facilities.
Service Parts Department
Bloomfield Industries
P.O. Box 280
Verdi, NV 89439
605 70988 Owners Manual Integrity 5W Decanter Brewer
SHIPPING DAMAGE CLAIMS PROCEDURE
NOTE: For your protection, please note that equipment in
this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any visible loss or damage is noted on the freight bill or express receipt, and that the note of loss or damage is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY: Regardless of the extent of the damage.
3. CONCEALED LOSS OR DAMAGE: if damage is unnoticed until the merchandise is unpacked, notify the transportation company or carrier immediately, and file “CONCEALED DAMAGE” claim with them. This must be done within fifteen (15) days from the date the delivery was made to you. Be sure to retain the container for inspection.
Bloomfield Industries cannot assume liability for damage or loss incurred in transit. We will, however, at your request, supply you with the necessary documents to support your claim.
xi
TABLE OF CONTENTS
WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 3 AGENCY LISTING INFORMATION 3 INSTALLATION INSTRUCTIONS 4 OPERATION 6 BREWING COFFEE 8 CLEANING INSTRUCTIONS 9 TROUBLESHOOTING SUGGESTIONS 10 SERVICING INSTRUCTIONS 11 Deliming Instructions 16 EXPLODED VIEW & PARTS LIST 18 WIRING DIAGRAMS 23
SPECIFICATIONS
MODEL STYLE VOLTS WATTS
8752
8752KFT
Decanter Brewer
5 Warmers
115/230 4000 19.4
Thank You for purchasing this Bloomfield Industries appliance.
Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.
This manual contains the information needed to properly install this appliance, and to use, care for and maintain or repair the appliance in a manner which will ensure its optimum perf ormance.
AMPS
POWER SUPPLY
CORD
None provided
Wire directly to circuit
APPLICABILITY
This manual applies to the following Bloomfield Industries products: Model 8752 Integrity 5-Warmer Coffee Brewer Model 8752KFT 5-Warmer Coffee Brewer
605 70988 Owners Manual Integrity 5W Decanter Brewer
1
FEAT U R E S AN D OP E RATING CON T ROLS
Fig. 1 Model 8752 Features and Operating Controls
2
605 70988 Owners Manual Integrity 5W Decanter Brewer
PRECAUTIONS AND GENERAL INFORMATION
WARNING: ELECTRIC SHOCK HAZARD
All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools.
Failure to heed this warning can result in electrical shock.
WARNING: INJURY HAZARD
All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical and plumbing codes. Failure could result in property damage and personal injury.
WARNING: ELECTRIC SHOCK HAZARD
Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious Injury.
WARNING: BURN HAZARD
This appliance dispenses very hot liquid. Serious bodily injury from scalding can occur from contact with dispensed liquids.
This appliance is intended for commercial use only. This appliance is intended for use to brew beverage products for
human consumption. No other use is recommended or authorized by the manufacturer or its agents.
This appliance is intended for use in commercial establishments, where all operators are familiar with the appliance use, limitations and associated hazards. Operating instructions and warnings must be read and unde r s to od by all operators and users.
Except as noted, this piece of equipment is made in the USA and has American sizes on hardware. All metric conversions are approximate and can vary in size.
The following trouble shooting, component views and parts lists are included for general reference, and are intended for use by qualified service personnel.
This manual should be considered a permanent part of this appliance. The manual must remain with the appliance if it is sold or moved to another location.
This brewer is and listed under UL file E9253.
This brewer meets operated and maintained in accordance with the enclosed
605 70988 Owners Manual Integrity 5W Decanter Brewer
instructions.
Standard 4 only when installed,
CAUTION:
ELECTRICAL DAMAGE
DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not follo wed.
CAUTION:
BURN HAZARD
Exposed surfaces of the appliance, brew chamber and decanter may be HOT to the touch, and can cause serious burns.
AGENCY LISTING INFORMATION
E9253
E9253
3
STD 4
INSTALLATION
READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION
IMPORTANT:
To enable the installer to make a quality installation and to minimize installation time, the following suggestions and tests should be done before the actual unit installation is started:
CAUTION:
ELECTRICAL
DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed.
DAMAGE
CAUTION:
UNSTABLE
DO NOT operate brewer unless factory supplied adjustable legs are installed and properly adjusted. It is very important for safety and for proper operation that the brewer is level and stable when standing in its final operating position. Provided adjustable legs must be installed at each corner of the unit. Failure to do so will result in movement of the brewer which can cause personal Injury and/or damage to brewer.
NOTE: Water supply inlet line must mee t cer tain min imum criteria to insure successful operation of the brewer. Bloomfield recommends 1/4" copper tubing for installation of less than 12 feet and 3/8" for more than 12 feet from a 1/2" water supply line.
EQUIPMENT HAZARD
REFER TO EXPLODED VIEWS FOR COMPONENT NAMES/ NUMBERS
Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit.
Verify that the Spray Head Gasket and Spray Disk are properly installed.
LEVELING THE UNIT
Verify that provided adjustable legs are installed at each corner of the brewer.
Set Brewer in its operating location. Level the Brewer. A spirit level should be placed on the top of the unit, at the edge, as a guide when making level adjustments.
Level the unit from left to right and front to back by turning the adjustable feet. Be sure all four feet touch the counter to prevent tipping.
PLUMBER’S INSTALLATION INSTRUCTIONS Brewer should be connected to a POTABLE WATER, COLD
WATER line. Flush water line before connecting to Brewer.
DO NOT use a saddle valve with a self-piercing tap for the water line connection. Such a tap can become restricted by waterline debris. For systems that must use a saddle tap, shut off the main water supply and drill a 3/16” (minimum) tap for the saddle connection, in order to insure an ample water supply. Remember to flush the line prior to installing the saddle.
The brewer must be installed on a water line with average pressure between 20 PSI and 90 PSI. If your water pressure exceeds 90 PSI at anytime, a pressure regulator must be installed in the water supply line to limit the pressure to not more than 90 PSI in order to avoid damage to lines and solenoid.
605 70988 Owners Manual Integrity 5W Decanter Brewer
4
INSTALLATION (continued)
A water shut-off valve should be installed on the incoming water line in a convenient location (Use a low restriction type valve, such as a 1/4-turn ball valve, to avoid loss of water flow thru the valve.
NSF requires that the brewer be able to be moved for cleaning underneath. A flex line or loops of copper tubing will satisfy this requirement. See Figure 2 below.
Fig. 2 Water Supply Installation
In some areas, local codes require a backflow preventer (check valve) to be installed on the inlet water line. If a backflow preventer is used, you must install a water hammer arrester in the incoming line, between the backflow preventer and the brewer inlet, as far away from the brewer as space will allow. This will relieve the excessive back pressures that can cause faucet leaks and solenoid mal functions.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1 Check the nameplate to determine correct electrical service required for this installation.
IMPORTANT: Before connecting to electricity, make sure the brewer is connected to the water supply.
IMPORTANT:
For power supply connections use COPPER WIRE only. Wiring must be suitable for at least 75ºC. This brewer requires a dedicated electric circuit.
Models 8752 must be wired by an electrician, and require a 115/230V 20A circuit (50/60 Hz, 2 hot legs / 1 neutral leg, plus ground). Remove rear panel to gain access to terminal block. Green terminal must be connected to a suitable building ground. Circuit must be capable of 4000 Watts. See figure 3 at right.
IMPORTANT: Wiring must be installed in approved solid or flexible conduit, and must be secured to the brewer with a strain
605 70988 Owners Manual Integrity 5W Decanter Brewer
relief (to be provided by the installer).
NOTE: This equipment must be installed to comply with applicable federal, state and local plumbing codes and ordinances.
WARNING:
SHOCK HAZARD
Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious injury.
IMPORTANT:
Supply power must match nameplate for voltage and phase. Connecting to the wrong voltage will damage the brewer or result in decreased performance. Such damage is not covered by warranty.
IMPORTANT: Do not connect brewer to electrical power until you are ready to fill the tank. See instructions on page 6.
Fig. 3 Electrical Installation
5
OPERATION
Fig. 4 Brewer Operation Diagram
IMPORTANT:
Tank must be full of water before pressing TANK HEATER SWITCH "
ON".
Heating elements will be damaged if allowed to operate without being fully submerged in water. Damage caused by operating the brewer without water in the tank is NOT COVERED BY WARRANTY.
START-UP
For initial start-up, or if the brewer has not been used for an extended period of time:
Be sure spray disk and brew gasket are prope rly installed in the brew head.
Be sure the water supply is properly connected and the water supply valve is turned ON.
Be sure the WATER TANK IS FILLED BEFORE connecting brewer to elec trical power THE WATER TANK
MUST BE FILLED. Place an empty decanter under the brew hea d. Lift the pour-over cover then pour warm tap water into the pour-over opening until water flows from the brew head. When water stops dripping from the brew head, empty the container.
Once the tank is full of water, connect the brewer to electrical power. Press the TANK HEATER SWITCH to “ elements will begin heating the water in the tank. When the water has reached the proper temperature, the READY TO BREW light will glow.
605 70988 Owners Manual Integrity 5W Decanter Brewer
ON”. The heating
6
Loading...
+ 18 hidden pages