Bloomfield 8742-3GUK Installation Manual

10 Sunnen Drive
St. Louis, MO 63143
telephone: 314-678-6336
fax: 314-781-2714
www.wellsbloomfield.com
BLOOMFIELD INDUSTRIES
OWNERS MANUAL
for
ICED TEA
BREWING SYSTEM
MODELS:
8742 8748
Model 8748 Brewer with optional 8602 Iced Tea Dispenser
Includes:
Installation
Operation
Use & Care
Servicing Instructions
p/n 2M-76116 Rev. J M606 100915
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery.
IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any visible loss or damage is noted on the freight bill or express receipt, and that the note of loss or damage is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY: Regardless of the extent of the damage.
3. CONCEALED LOSS OR DAMAGE: if damage is unnoticed until the merchandise is unpacked, notify the transportation company or carrier immediately, and
le “CONCEALED DAMAGE” claim with them. This must be done within fteen (15) days from the date
the delivery was made to you. Be sure to retain the container for inspection.
Wells Bloomeld cannot assume liability for damage or loss
incurred in transit. We will, however, at your request, supply you with the necessary documents to support your claim.
WARRANTY STATEMENT
SERVICE POLICY AND PROCEDURE GUIDE
ADDITIONAL WARRANTY EXCLUSIONS
SHIPPING DAMAGE CLAIMS PROCEDURE
1. Resetting of safety thermostats, circuit breakers, overload protectors, or fuse replacements unless warranted conditions are the cause.
2. All problems due to operation at voltages other than
specied on equipment nameplates; conversion to
correct voltage must be the customer’s responsibility.
3. All problems due to electrical connections not made in accordance with electrical code requirements and wiring diagrams supplied with the equipment.
4. Replacement of items subject to normal wear, to include such items as knobs and light bulbs. Normal maintenance functions including adjustment of thermostats, microswitches, and replacement of fuses and indicating lights are not covered under warranty.
5. All problems due to inadequate water supply, such as uctuating, or high or low water pressure.
6. All problems due to mineral/calcium deposits, or contamination from chlorides/chlorines. De-liming is considered a preventative maintenance function and is not covered by warranty.
All electrical equipment manufactured by WELLS BLOOMFIELD, LLC is warranted against defects in materials and workmanship for a period of one year from the date of
original installation or eighteen (18) months from the date of shipment from our factory, whichever comes rst, and is for the benet of the original purchaser, except that:
a. airpots carry a 30 day parts warranty only.
b. dispensers; i.e., tea and coffee carry a 90 days parts
warranty only, excludes decanters. THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN
IN LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXCLUDED.
WELLS BLOOMFIELD, LLC SHALL NOT BE LIABLE FOR INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY CAUSE WHATSOEVER.
This warranty is void if it is determined that upon inspection by an Authorized Service Agency that the equipment has
been modied, misused, misapplied, improperly installed, or damaged in transit or by re, ood or act of God.
It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service.
The prices charged by Bloomeld Industries for its products
are based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to the repair of
defects without charge by a Bloomeld Authorized Service
Agency or one of its sub-agencies. This service will be provided on customer’s premises for non-portable models.
Portable models (a device with a cord and plug) must be
taken or shipped to the closest Authorized Service Agency, transportation charges prepaid, for services.
In addition to restrictions contained in this warranty, specic limitations are shown below (Additional Warranty Exclusions). Bloomeld Industries Authorized Service Agencies are located
in principal cities. This warranty is valid in the United States and void elsewhere.
Please consult your classied telephone directory or your food service equipment dealer; or, for information and other details
concerning warranty, write to:
Service Parts Department
Wells Bloomeld, LLC
10 Sunnen Drive, St. Louis, MO 63143
Phone: (314) 678-6336... Fax: (314) 781-2714
7. Full use, care and maintenance instructions are supplied with each machine. Those miscellaneous adjustments noted are customer responsibility. Proper attention will prolong the life of the machine.
8. Travel mileage is limited to sixty (60) miles from an
authorized Service Agency or one of its sub-agencies.
9. All labor shall be performed during normal working hours.
Overtime premium shall be charged to the customer.
10. All genuine Bloomeld replacement parts are warranted for ninety (90) days from date of purchase on non-
warranted equipment. Any use of non-genuine
Bloomeld parts completely voids any warranty.
11. Installation, labor and job check-out are not considered warranty.
12. Charges incurred by delays, waiting time or operating restrictions that hinder the service technicians ability to perform services are not covered by warranty. This includes institutional and correctional facilities.
xi
606 Owners Manual for 8742-8748 Tea Brewer 2M-76116
TABLE OF CONTENTS
WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 3 AGENCY LISTING INFORMATION 3 INSTALLATION INSTRUCTIONS 4 OPERATION 6 BREWING TEA 8 CLEANING INSTRUCTIONS 9 TROUBLESHOOTING SUGGESTIONS 10 SERVICING INSTRUCTIONS 11 Deliming Instructions 15 EXPLODED VIEW & PARTS LIST 16 WIRING DIAGRAMS 20
SPECIFICATIONS
8742 & 8748 3 - 5 Gallon Ice Tea Brewers
MODEL DIMENSIONS VOLTS WATTS AMPS 1ø POWER SUPPLY CORD
3 Gallon Iced Tea Brewer
8742 32-1/4” high 120 1500 12.5 NEMA 5-15P
8742-3G 10-15/16” wide
8742-3GUK 15-11/16” deep CW 3100
8748 35-1/4” high 120 1500 12.5 NEMA 5-15P
8748-5G 10-15/16” wide
8748-5GUK 15-11/16” deep CW 3100
606 Owners Manual for 8742-8748 Tea Brewer 2M-76116
220-240V 1800 7.8
5 Gallon Iced Tea Brewer
220-240V 1800 7.8
APPLICABILITY
This manual applies to the following Wells Bloomeld products:
8742 8748
Thank You for purchasing this
Wells Bloomeld appliance.
Proper installation, professional
operation and consistent
maintenance of this appliance will ensure that it gives you the very
best performance and a long, economical service life.
This manual contains the
information needed to properly install this appliance, and to use, care for and maintain or repair the
appliance in a manner which will
ensure its optimum performance.
CEE 7/VII
CEE 7/VII
1
FEATURES AND OPERATING CONTROLS
IL1673
606 Owners Manual for 8742-8748 Tea Brewer 2M-76116
2
PRECAUTIONS AND GENERAL INFORMATION
E9253
STD 4
WARNING: ELECTRIC SHOCK HAZARD
All servicing requiring access to non-insulated components must be performed by qualied service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock.
WARNING: INJURY HAZARD
All installation procedures must be performed by qualied personnel with full knowledge of all applicable electrical and plumbing codes. Failure could result in property damage and personal injury.
WARNING: ELECTRIC SHOCK HAZARD
Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious Injury.
WARNING: BURN HAZARD
This appliance dispenses very hot liquid. Serious bodily injury from scalding can occur from contact with dispensed liquids.
This appliance is intended for commercial use only.
This appliance is intended for use to brew beverage products for
human consumption. No other use is recommended or
authorized by the manufacturer or its agents.
This appliance is intended for use in commercial establishments,
where all operators are familiar with the appliance use,
limitations and associated hazards. Operating instructions and warnings must be read and understood by all operators and users.
Except as noted, this piece of equipment is made in the USA and has American sizes on hardware. All metric conversions are approximate and can vary in size.
The following trouble shooting, component views and parts lists are included for general reference, and are intended for use by qualied service personnel.
This manual should be considered a permanent part of this
606 Owners Manual for 8742-8748 Tea Brewer 2M-76116
appliance. The manual must remain with the appliance if it is sold or moved to another location.
AGENCY LISTING INFORMATION
This brewer is listed under UL le E9253.
CAUTION:
EQUIPMENT DAMAGE
DO NOT plug in or energize this
appliance until all Installation Instructions are read and followed.
Damage to the Brewer will occur if
these instructions are not followed.
CAUTION:
BURN HAZARD
Exposed surfaces of the appliance, brew chamber and dispenser may be HOT to the touch, and can cause serious burns.
This brewer meets
operated and maintained in accordance with the enclosed instructions.
Standard 4 only when installed,
3
INSTALLATION
READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION
IMPORTANT:
To enable the installer to make
a quality installation and to minimize installation time, the following suggestions and tests should be done before the actual unit installation is started:
CAUTION:
EQUIPMENT DAMAGE
DO NOT plug in or energize this
appliance until all Installation
Instructions are read and followed. Damage to the
Brewer will occur if these
instructions are not followed.
CAUTION:
UNSTABLE EQUIPMENT HAZARD
It is very important for safety
and for proper operation that the brewer is level and stable when standing in its nal operating position. Provided adjustable, non-skid legs must be installed at each corner of the unit. Failure to do so will result in
movement of the brewer which
can cause personal Injury and/ or damage to brewer.
NOTE: Water supply inlet line must meet certain minimum criteria to insure successful
operation of the brewer. Bloomeld recommends 1/4”
copper tubing for installation of
less than 12 feet and 3/8” for more than 12 feet from a 1/2” water supply line.
Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit.
Verify that the Spray Head Gasket and Spray Disk are properly installed.
LEVELING THE UNIT
Verify that an adjustable leg is installed at each corner of the brewer, and that a rubber foot is installed on each leg.
Set Brewer in its operating location. Level the Brewer. A spirit level should be placed on the top of the unit, at the edge, as a guide when making level adjustments.
Level the unit from left to right and front to back by turning the adjustable feet. Be sure all four feet touch the counter to prevent tipping.
PLUMBER’S INSTALLATION INSTRUCTIONS
Brewer must be connected to a POTABLE WATER, COLD WATER line. Flush water line before connecting to Brewer.
DO NOT use a saddle valve with a self-piercing tap for the water line connection. Such a tap can become restricted by waterline debris. For systems that must use a saddle tap, shut off the main water supply and drill a 3/16” (minimum) tap for the saddle connection, in order to insure an ample water supply. Remember to ush the line prior to installing the saddle.
The brewer must be installed on a water line with average pressure between 20 PSI and 90 PSI. If your water pressure exceeds 90 PSI at anytime, a pressure regulator must be installed in the water supply line to limit the pressure to not more than 90 PSI in order to avoid damage to lines and solenoid.
A water shut-off valve should be installed on the incoming water line in a convenient location (Use a low restriction type valve, such as a 1/4-turn ball valve, to avoid loss of water ow thru the valve.
The provided water line strainer must be installed in the supply line, between the shutoff valve and inlet tting. Note FLOW arrow marking on strainer body.
606 Owners Manual for 8742-8748 Tea Brewer 2M-76116
4
INSTALLATION (continued)
NEMA 5-15R
RECEPTAC LE
NEMA 5-15P
PLUG
GROUND
PIN
NSF requires that the brewer be able to be moved for cleaning underneath. A ex line or loops of copper tubing will satisfy this requirement. See Figure 2 below.
Fig. 2 Water Supply Installation
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service required for the Brewer to be installed.
IMPORTANT: Before connecting to electricity, make sure
automatic brewers are connected to the water supply.
Models 8742 and 8748 are equipped with a cord and plug.
They require a 115 - 125 volt 20 amp circuit (50/60 Hz, 2 wire plus ground, with NEMA 5-15R or 5-20R Receptacle).
NOTE: This equipment must
be installed to comply with applicable federal, state and local plumbing codes and ordinances.
WARNING:
SHOCK HAZARD
Brewer must be properly
grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious injury.
IMPORTANT:
Supply power must match
nameplate for voltage and phase. Connecting to the wrong voltage will damage the brewer
or result in decreased perfor-
mance. Such damage is not covered by warranty.
IMPORTANT: Do not connect brewer to electrical power until
you are ready to ll the tank. See instructions at left.
606 Owners Manual for 8742-8748 Tea Brewer 2M-76116
IMPORTANT: The ground
prong of the plug is part of a
system designed to protect
you from electrical shock in the
event of internal damage. Nev-
er cut off the ground prong nor twist a blade to t an existing receptacle. Contact a licensed
electrician to install the proper
circuit and receptacle.
5
OPERATION
Fig. 3 Brewer Operation Diagram
IMPORTANT:
Tank must be full of water before pressing TANK
HEATER SWITCH “on”.
A.
For initial start-up, or if the brewer has not been used for an extended period of time:
Be sure spray disk and brew gasket are properly installed in the
Heating elements will be
damaged if allowed to
Be sure the water supply is properly connected and the water
operate without being
fully submerged in water. Damage caused by
operating the brewer without water in the tank
Be sure the WATER TANK IS FILLED.
IMPORTANT: Fill the water tank before energizing this unit:
1. Insert the brew chamber (empty) and place an empty dispenser in
is NOT COVERED BY WARRANTY.
2. Be sure the TANK HEATER SWITCH is “off”. Plug the unit into an
3. Press The BREW switch. Water will start lling the tank. Run
4. When water stops dripping from the brew chamber, empty the
START-UP
brew head.
supply valve is turned ON.
place under the brew chamber.
appropriate receptacle.
several consecutive brew cycles until water ows from the brew chamber.
dispenser, then press TANK HEAT switch “on”. The heating element will begin heating water in the tank. When the water has reached the proper brewing temperature, the “READY TO BREW” light will glow.
6
606 Owners Manual for 8742-8748 Tea Brewer 2M-76116
Loading...
+ 16 hidden pages