Bloomfield 8708 Dual In-Line Warmer Operation Manual

10 Sunnen Drive
St. Louis, MO 63143
telephone: 888-356-5362
fax: 314-781-2714
www.wellsbloomfield.com
BLOOM FIELD I N D U STRIES
763
OPERATION MANUAL
For
Hot Plate-Style
Decanter Warmer
MODELS
8708 Dual In-Line Warmer
8851 Single Warmer
8852 Dual Warmer
Includes:
Installation Use & Care
NOTE: All warmers shown with optional 8900-Series Glass Decanters (available separately).
p/n 2M-77719 Rev. B M763 110811
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery.
IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any visible loss or damage is noted on the freight bill or express receipt, and that the note of loss or damage is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY: Regardless of the extent of the damage.
3. CONCEALED LOSS OR DAMAGE: if damage is unnoticed until the merchandise is unpacked, notify the transportation company or carrier immediately, and file “CONCEALED DAMAGE” claim with them. This must be done within fifteen (15) days from the date the delivery was made to you. Be sure to retain the container for inspection.
Wells Bloomfield cannot assume liability for damage or loss incurred in transit. We will, however, at your request, supply you with the necessary documents to support your claim.
WARRANTY STATEMENT
SERVICE POLICY AND PROCEDURE GUIDE
ADDITIONAL WARRANTY EXCLUSIONS
SHIPPING DAMAGE CLAIMS PROCEDURE
1. Resetting of safety thermostats, circuit breakers, overload protectors, or fuse replacements unless warranted conditions are the cause.
2. All problems due to operation at voltages other than specified on equipment nameplates; conversion to correct voltage must be the customer’s responsibility.
3. All problems due to electrical connections not made in accordance with electrical code requirements and wiring diagrams supplied with the equipment.
4. Replacement of items subject to normal wear, to include such items as knobs and light bulbs. Normal maintenance
functions including adjustment of thermostats, microswitches,
and replacement of fuses and indicating lights are not
covered under warranty.
5. All problems due to inadequate water supply, such as
fluctuating, or high or low water pressure.
6. All problems due to mineral/calcium deposits, or
contamination from chlorides/chlorines. De-liming is considered a preventative maintenance function and is not covered by warranty.
All electrical equipment manufactured by WELLS BLOOMFIELD is warranted against defects in materials and workmanship for a period of one year from the date of original installation or eighteen (18) months from the date of shipment from our factory, whichever comes first, and is for the benefit of the original purchaser, except that: a. airpots carry a 30 day parts warranty only. b. dispensers; i.e., tea and coffee carry a 90 days parts warranty only, decanters excluded.
THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXCLUDED.
BLOOMFIELD INDUSTRIES DIVISION / SPECIALTY EQUIPMENT MANUFACTURING CORPORATION SHALL NOT BE LIABLE FOR INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY CAUSE WHATSOEVER.
This warranty is void if it is determined that upon inspection by an Authorized Service Agency that the equipment has been modified, misused, misapplied, improperly installed, or damaged in transit or by fire, flood or act of God.
It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. The prices charged by Wells Bloomfield for its products are based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to the repair of defects without charge by a Wells Bloomfield Authorized Service Agency or one of its sub-agencies. This service will be provided on customer’s premises for non-portable models. Portable models (a device with a cord and plug) must be taken or shipped to the closest Authorized Service Agency, transportation charges prepaid, for services.
In addition to restrictions contained in this warranty, specific limitations are shown below (Additional Warranty Exclusions). Wells Bloomfield Authorized Service Agencies are located in principal cities.
This warranty is valid in the United States and void elsewhere. Please consult your classified telephone directory or your food service equipment dealer; or, for information and other details concerning warranty, write to:
Service Parts Department
Wells Bloomfield, LLC 10 Sunnen Dr. P.O. Box 430129 St. Louis, MO 63143 USA
Phone: 1-800-807-9054 Fax: 1-800-396-2677
7. Full use, care and maintenance instructions are supplied with each machine. Those miscellaneous adjustments noted are customer responsibility. Proper attention will prolong the life of the machine.
8. Travel mileage is limited to sixty (60) miles from an authorized Service Agency or one of its sub-agencies.
9. All labor shall be performed during normal working hours. Overtime premium shall be charged to the customer.
10. All genuine Bloomfield replacement parts are warranted for ninety (90) days from date of purchase on non- warranted equipment.
Any use of non-genuine Wells Bloomfield parts completely voids any warranty.
11. Installation, labor and job check-out are not considered warranty.
12. Charges incurred by delays, waiting time or operating restrictions that hinder the service technicians ability to perform services are not covered by warranty. This includes institutional and correctional facilities.
xi
xi
763 p/n 2M-77719 OpManual Decanter Warmers
TABLE OF CONTENTS
W
ARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 3 AGENCY LISTING INFORMATION 3 INSTALLATION INSTRUCTIONS 4 OPERATION 5 CLEANING INSTRUCTIONS 5
EXPLODED VIEWS, PARTS LISTS & WIRE DIAGRAMS 8852 6 8708
7
8851 8
Thank You for purchasing this
Wells Bloomeld appliance.
Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.
This manual contains the information needed to properly install this appliance, and to use, care for the appliance in a man­ner which will ensure its optimum performance.
SPECIFICATIONS
MODEL STYLE VOLTS 1ø WATTS AMPS POWER SUPPLY CORD
8708
8708DSU
Dual Step-Up
8708DSUUK CW 3100
8851
8851S
Single
8851SUK CW 3100
8852
8852D
Dual
8852DUK CW 3100
120 VAC
220-240V 0.8
200
120 VAC
220-240V 0.44
100
1.7 NEMA-5-15P
0.8 NEMA-5-15P
120 VAC 200 1.7 NEMA-5-15P
220-240V 200 0.8
CEE 7/VII
CEE 7/VII
CEE 7/VII
763 p/n 2M-77719 OpManual Decanter Warmers
Decanter warmers operate at a warming temperature of approximately 185ºF ± 10ºF (85 ºC ± 6ºC).
1
FEATURES AND OPERATING CONTROLS
POWER CORD
WARMER PLATE
WARMER SWITCH
OPTIONAL DECANTER (SHOWN FOR POSITION ONLY)
SLIP-RESISTANT FEET
IL2044a
Fig. 1 Features & Operating Controls Model 8852 shown. Features are similar for all models.
2
763 p/n 2M-77719 OpManual Decanter Warmers
PRECAUTIONS AND GENERAL INFORMATION
ST D 4
WARNING: ELECTRIC SHOCK HAZARD
All servicing requiring access to non-insulated components must be performed by qualied
service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock.
WARNING: INJURY HAZARD
All installation procedures must be performed by qualied personnel with full knowledge of all
applicable electrical codes. Failure could result in property damage and personal injury.
WARNING: ELECTRIC SHOCK HAZARD
Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious injury.
This appliance is intended for indoor commercial use only.
This appliance is intended for use to maintain the temperature of hot liquids beverage products for human consumption. No other use is recommended or authorized by the manufacturer or its agents.
This appliance is intended for use in commercial establishments, where all operators are familiar with the appliance use, limitations and associated hazards. Operating instructions and warnings must be read and understood by all operators and users.
The following trouble shooting, component views and parts lists are included for general reference, and are intended for use by
qualied service personnel.
This manual should be considered a permanent part of this appliance. The manual must remain with the appliance if it is sold or moved to another location.
CAUTION:
EQUIPMENT DAMAGE
DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the warmer may occur if these instructions are not followed.
CAUTION:
BURN HAZARD
Exposed surfaces of the warmer may be HOT to the touch. The warmer plate will be very hot during operation and can cause serious burns on contact.
Do not discard this appliance as usual trash at the end of its useful life. Recycle properly.
AGENCY LISTING INFORMATION
This warmer is listed under UL le E9253.
763 p/n 2M-77719 OpManual Decanter Warmers
This brewer meets Standard 4 only when installed, operated and maintained in accordance with the enclosed instructions.
LI STED E 92 53
3
INSTALLATION INSTRUCTIONS
READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION
CAUTION:
EQUIPMENT DAMAGE
DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed.
CAUTION:
UNSTABLE EQUIPMENT HAZARD
It is very important for safety and for proper operation that the brewer is level and stable when
standing in its nal operating
position. Provided adjustable, non-skid legs must be installed at each corner of the unit.. Failure to do so will result in movement of the brewer which can cause personal Injury and/or damage to brewer.
Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit.
Verify that the Spray Head Gasket and Spray Disk are properly installed.
LEVELING THE UNIT
Verify that slip-resistant foot is installed at each corner of the warmer.
Set warmer in its operating location. Level the warmer. A spirit level should be placed on the top of the unit, at the edge, as a guide when making level adjustments.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1 Check the nameplate to determine correct electrical service required for the Brewer to be installed.
Warmer models 8708, 8851, 8852, 8871 and 8872 are equipped with a cord and plug. They require a 115 - 125 volt 15 amp circuit (50/60 Hz, 2 wire plus ground, with NEMA 5-15R receptacle).
WARNING:
SHOCK HAZARD
Brewer must be properly ground­ed to prevent possible shock haz­ard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious injury.
IMPORTANT:
The ground prong of the plug is part of a system designed to protect you from electrical shock in the event of internal damage. Never cut off the ground prong
nor twist a blade to t an
existing receptacle. Contact a licensed electrician to install the proper circuit and receptacle.
763 p/n 2M-77719 OpManual Decanter Warmers
4
OPERATION
Place a decanter of hot beverage on a warmer plate.
Press warmer switch for that warmer plate to ON ( I ).
Press warmer switch to OFF (O) when a warmer plate is not in use for any extended period.
SUGGESTION: Coffee loses its fresh avor if allowed to set on a
warmer for too long. Discard stale coffee promptly.
DO NOT allow an empty decanter to set on a hot warmer. This will damage the decanter. Discard any decanter that has been allowed to boil dry.
Disconnect warmer from electric power if unused for prolonged periods (i.e. overnight).
CLEANING INSTRUCTIONS
PROCEDURE: Clean Coffee Warmer
PRECAUTIONS: Disconnect warmer from electric power.
Allow warmer to cool.
FREQUENCY: Daily
TOOLS: Mild Detergent, Clean Soft Cloth or Sponge
1. Disconnect warmer from electric power. Allow warmer to cool before cleaning. Remove decanters.
2. Wipe the warmer plates with a sponge dampened with warm water and a mild detergent. Rinse with clean water and allow to air dry.
3. Wipe the exterior of the warmer with a soft clean cloth or sponge moistened with clean water and allow to air dry.
Procedure is complete
CAUTION:
BURN HAZARD
Exposed surfaces of the warmer may be HOT to the touch. The warmer plate will be very hot during operation and can cause serious burns on contact.
CAUTION:
BURN HAZARD
Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns.
CAUTION:
SHOCK HAZARD
Do not submerge or immerse warmer in water. Do not pour or splash water onto switches or wiring.
IMPORTANT:
DO NOT use steel wool, sharp objects, or caustic, abrasive or chlorinated cleansers to clean the warmer.
763 p/n 2M-77719 OpManual Decanter Warmers
5
8852 EXPLODED VIEW / PARTS LIST / WIRING DIAGRAM
REPLACEM EN T PART S LIST
MODEL 8852
SLIM LINE DOUBLE WARMER
120V, 200 W
220/240V, 200W Export
8
4
6
7
9
10
11
5
1
2
WIRING
DIAGRAM
8852
GREEN
BLACK
RED
RED
BLACK
BLACK
WHITE
WHITE
WHITE
WHITE
RIGHT WARMER SWITCH
LEFT
WARMER
SWITCH
ELEMENT
ELEMENT
3 2 1
3 2 1
POWER
CORD
NOTE: Export Cord
White = Blue
Black = Brown
8852 Slim Line Double Warmer
8852 8852 UK 8852 EU
Fig No Description
1 PLATE COVER WARMER 2D-70090
2 ELEM WARMER FLAT 120V 100W 2N-70091UL 2N-70636UL
4 CORD & CAP 2E-70293 A6-WL0140 A6-WL0141
5 STRAIN RELIEF STR 2K-70215 2K-70648
6 BODY, WARMER E5-WL0136
7 SWITCH ON-OFF LITED 120V 2E-72946 2E-70247
8 PANEL BOTTOM E5-Z13605
9 FERRULE EYELET 2C-70316
10 BUMPERS RUBBER BLACK DD-70315
11 SCREW 8X1/2 PH PAN DRILL 2C-301522
6
Part No.
763 p/n 2M-77719 OpManual Decanter Warmers
8708 EXPLODED VIEW / PARTS LIST / WIRING DIAGRAM
ELEMENT
ELEMENT
UPPER WARMER SWITCH
LOWER WARMER SWITCH
UPPER
WARMER
LOWER
WARMER
POWER
CORD
1
2
7
4
3
5
10
a
9
d
8
c
b
a
6
IL2029
REPLACEMENT PARTS LIST
MODEL 8708 STEP-UP DOUBLE WARMER
MODEL 8708 STEP-UP DOUBLE WARMER
Item No Part No Description Application
1 2D-70090 PLATE COVER WARMER 2 E5-71203 COVER WARMER TOP 3 A6-71206 BODY SUB ASSY 8708 WARMER 4 E5-71204 COVER BACK WARMER 5 E5-70339 PLATE BOT S/A DBL STEP-UP
6
2E-70393 CORD & CAP ASSY 120V A6-WL0141 CORD & EURO PLUG TERM 230V A6-WL0140 CORD & UK PLUG ASSY TERM 230UK
763 p/n 2M-77719 OpManual Decanter Warmers
2K-70215 STRAIN RELIEF STR 120V
7
2K-70648 STRAIN RELIEF SMALL 230V, 230UK 2N-70091UL ELEM WARMER 120V 100W 120V
8
2N-70635UL ELEM WARMER 100W 240V/85W 230V, 230UK 2E-72946 SWITCH ON-OFF LITED 120V 120V
9
2E-70247 SWITCH ON OFF LTD BLACK 2 230V, 230UK
10 2A-71732 LEG ASSY LEVELING
a 2C-70127 SCREW 8BX3/8 PH TR HD b 2C-70098 CLIP c 2C-70099 SCREW 8-32X3/8 PH PAN d 2C-70132 NUT TNR ZI #8
8851 EXPLODED VIEW / PARTS LIST / WIRING DIAGRAM
GREEN
BLACK
WHITE
RED
ELEMENT
POWER
CORD
POWER
SWITCH
WIRING
DIAGRAM
3 2 1
1
2
6
7
9
11
8
5
4
4 4
10
IL2056
EU UK
NOTE: 120V DIAGRAM SHOWN, 220V
SAME EXCEPT USE 220V ELEMENT,
CORD AND PLUG, WIRE COLORS.
# DESCRIPTION
1 Cover Plate 2D-70090
2 Element Heating 2N-70091UL 2N-70635UL
4 Assy. Power Cord w/Plug 2E-70295 A6-WL0140 A6-WL0141
5 Strain Relief, Power Cord 2K-70215 2K-70648
6 Body, Warmer E5-WL0142
MODEL 8851S MODEL 8851S MODEL 8851S
120V UK 230V EU 230V
7 Switch, Lighted 2E-72946 2E-70247
8 Panel, Bottom E5-Z13649
9 Ferrule Eyelet 2C-70316
10 Foot, Black Rubber DD-70315
PARTS LIST
PART Number
11 Screw, #8 STSM 5/8” 2C-70092
763 p/n 2M-77719 OpManual Decanter Warmers
8
NOTES
763 p/n 2M-77719 OpManual Decanter Warmers
10 Sunnen Drive, St. Louis, MO 63143
telephone: 888-356-5362 fax: 314-781-2714
www.wellsbloomfield.com