BLOOMFIELD INDUSTRIES SERVICE INSTRUCTIONS
2 Erik Circle
Verdi, Nevada 89439 SOLENOID VALVE RETROFIT KIT
(775) 345-0444 84571 (120V) and 84572 (220/240V)
A. APPLICABILITY
B. INSTRUCTIONS
1. REMOVE EXISTING SOLENOID (See fig. B.1 and B.2)
a. Unplug brewer and shut off water supply. Open faucet to bleed off water
b. Remove TOP PANEL, FRONT PANEL and SOLENOID ACCESS DOOR.
c. Disconnect wires to solenoid. Remove silicone SUPPLY HOSE from solenoid.
d. Disconnect FAUCET SUPPLY TUBE from solenoid and faucet shut-off valve.
e. Remove BRASS NUT from INLET FITTING.
Lift solenoid / timer / bracket
assembly from mounting clip.
f. Loosen screws on bottom of solenoid and
separate solenoid from bracket.
Remove solenoid and fittings from cabinet.
Reinstall bracket on mounting clip.
This kit replaces the solenoid valve and faucet supply tube on automatic brewer models:
Koffee-King™ 8540 8572 Domestic and Export
Integrity™ 9010 9012 Domestic and Export
CAUTION: ELECTRIC SHOCK HAZARD
Unplug brewer before beginning conversion
pressure.
Integrity™ shown
Koffee-King™ similar
ACCESS DOOR
p/n 74535 Rev.(-) 040500cps page 1 Of 3
Fig. B.1
TUBE
SOLENOID
ASSEMBLY
Fig. B.2
DISCONNECT
• SOLENOID ACCESS DOOR
• SOLENOID AND FLOW CONTROL
• INLET FITTING, TEE & ADAPTERS
B. INSTRUCTIONS (continued)
2. INSTALL NEW SOLENOID (See figure B.3, B.4 and B.5)
a. Attach faucet supply BRAIDED HOSE to SOLENOID.
Push the hose fully onto the bypass outlet (the side
without a solenoid coil). Install one CLAMP over the
shaft of the outlet, and one CLAMP directly over the
barb of the outlet.
b. Assemble the SOLENOID BRACKET to the new
ACCESS DOOR. Assemble the SOLENOID to the
SOLENOID BRACKET.
c. Route the silicone SUPPLY TUBE through the 3rd
hole (from the front) then out the access door opening.
Attach tube to SOLENOID. Push the tube fully onto
the controlled outlet (the side with the solenoid coil).
d. Route the BRAIDED HOSE through the 1st hole (from
the front). Connect the flare SWIVEL NUT to the end
of the braided hose. Rotate the FAUCET SHUT-OFF
VALVE as needed (approximately 45° and connect the
swivel nut to the valve. Verify all connections are tight.
e. Assemble the ACCESS DOOR / SOLENOID to the cabinet.
f. Turn water supply ON. Check for leaks.
g. Insert BUTTON PLUG in the hole formerly occupied
by the inlet fitting.
h. Reinstall TOP PANEL and FRONT PANEL.
Plug unit in and test.
SHUT-OFF VALVE 45°
HOSE TO OUTLET
WITH SOLENOID:
* PUSH HOSE
FULLY AGAINST
ROUTE HOSES
AS SHOWN
p/n 74535 Rev.(-) 040500cps Page 2 Of 3
Fig. B.4
TO OUTLET WITHOUT
SOLENOID (BYPASS):
* PUSH HOSE FULLY
AGAINST VALVE BODY
Fig. B.5
* PLACE FIRST CLAMP
ON OUTLET SHAFT
* CENTER SECOND
CLAMP DIRECTLY OVER
BARB