Bloomfield 84571, 84572, 84575, 84574, 86606 Operation Manual

...
WELLS BLOOMFIELD, LLC
2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439 telephone: 775-689-5707
fax: 775-689-5976
www.wellsbloomfield.com
600
SERVICE INSTRUCTIONS
SOLENOID VALVE RETROFIT KIT NUMBERS
86606 86644 86650
Wrench p/n 86660 is designed to allow easy removal of the braided faucet hose from the plastic solenoid valve.
FOR REMOVING BRAIDED HOSE: IMPORTANT: Shut-off water supply to brewer before
removing faucet hose.
1. Slide the 7/16" end of the wrench between the valve body and the white ring on the extreme end of the metal hose fitting.
2. Pressure on the white ring toward the metal ferrule releases the clinch ring, allowing the hose to be easily slid off of the solenoid bypass outlet.
3. Reinstall hose by pressing end of hose onto bypass outlet until it is fully seated.
FOR REMOVING FLARE FITTING
1. Slide the 5/8" end of the wrench over the flats on the inlet fitting of the valve.
2. Hold the wrench to prevent the inlet fitting from turning while installing or removing the inlet water supply flare nut.
BRAIDED HOSE
7/16” for
5/8” for VALVE FITTING
P/N 86660 BRAIDED HOSE WRENCH
WRENCH #86660
BYPASS OUTLET
WHITE CLINCH RING
WRENCH
METAL
VALV E
SLIDE WRENCH BETWEEN VALVE AND CLINCH RING. PRESS CLINCH RING TOWARD METAL FITTING TO RELEASE.
PRINTED IN UNITED STATES OF AMERICA
p/n 76661 Rev. A ECN-13394 I 600 080211 cps
1 of 1
HOSE FITTING
CLINCH RING