Bloomfield 8382CA Installation Manual

OWNERS MANUAL
for
BOTTLED WATER
AIRPOT
COFFEE BREWERS
MODEL
682
Model 8382 Brewer
8382
for
3 Gallon
and
5 Gallon
Plastic Bottles
Includes:
Installation
Operation
Use & Care
Servicing Instructions
PRINTED IN UNITED STATES OF AMERICA
p/n 75611 Rev. F ECN-12902 M682 050715 cps
WARRANTY STATEMENT
All electrical equipment manufactured by BLOOMFIELD INDUSTRIES is warranted against defects in material and workmanship for a period of one year from original purchase or eighteen months from the date of shipment from our factory, whichever comes first, and is for the benefit of the original purchaser, except that; airpots carry a 30 day warranty only; dispensers i.e. tea and coffee carry a 90 day warranty; and, decanters are excluded.
THIS WARRANTY IS THE COMPLETE AND ONLY WARRANTY, EXPRESSED OR IMPLIED IN LAW OR IN FACT, INCLUDING, BUT NOT LIMITED TO, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICU­LAR PURPOSE, AND/OR INDIRECT OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH BLOOMFIELD PRODUCTS.
This warranty is void if it is determined upon inspection by an Authorized Service Agency that the equipment has been modified, misused, misapplied, improperly installed, or damaged in transit or by fire, flood or act of God.
It also does not apply if the serial nameplate has been removed or service is performed by unauthorized personnel.
SERVICE POLICY AND PROCEDURE GUIDE
ADDITIONAL WARRANTY EXCLUSIONS
1. Resetting of safety thermostats, circuit breakers, overload protectors, or fuse replacements unless warranted conditions are the cause.
2. All problems due to operation at voltages other than specified on equipment nameplates—conversion to correct voltage must be the customer’s responsibility.
3. All problems due to electrical connections not made in accordance with electrical code requirements and wiring diagrams supplied with the equipment.
4. Replacement of items subject to normal wear, to include such items as knobs and light bulbs. Normal maintenance functions including adjustment of thermostats, microswitches, and replacement of fuses and indicating lights are not covered under warranty.
5. All problems due to inadequate water supply, such as fluctuating, or high or low water pressure.
6.
All problems due to mineral/calcium deposits, or contamination from chlorides/chlorines. De-liming is considered a preventative maintenance function and is not covered by warranty.
The prices charged by Bloomfield Industries for its products are based upon the limitations in this warranty. Seller’s obli­gation under this warranty is limited to repair of defects with­out charge by a Bloomfield Industries Authorized Service Agency or one of its sub-agencies. This service will be provided on customer’s premises for non-portable models. Portable models (a device with a cord and plug) must be taken or shipped to the closest Authorized Service Agency, transportation charges prepaid for service.
In addition to restrictions contained in this warranty, specific
limitations are detailed in the ADDITIONAL WARRANTY EXCLUSIONS section. Bloomfield Industries Authorized
Service Agencies are located in principal cities.
This warranty is valid in the United States and void elsewhere. Please consult your classified telephone directory, your food service equipment dealer, or, for information and other details concerning warranty write to:
Service Parts Department
Bloomfield Industries
P. O. Box 280
Verdi, Nevada 89439
(775) 689-5700 fax (888) 492-2783
7. Full use, care and maintenance instructions are supplied with each machine. Those miscellaneous adjustments noted are customer responsibility. Proper attention will prolong the life of the machine.
8. Travel mileage is limited to sixty (60) miles from an authorized Service Agency or one of its sub-agencies.
9. All labor shall be performed during normal working hours. Overtime premium shall be charged to the customer.
10.
All genuine Bloomfield replacement parts are warranted for
ninety (90) days from date of purchase on non-warranted equipment.
Any use of non-genuine Bloomfield parts completely voids any warranty.
11. Installation, labor and job check-out are not considered warranty.
12. Charges incurred by delays, waiting time or operating restrictions that hinder the service technicians ability to perform services are not covered by warranty. This includes institutional and correctional facilities.
682 75611 Owners Manual 8382 Aquarius™ Airpot Brewer
SHIPPING DAMAGE CLAIMS PROCEDURE
NOTE: For your protection, please note that equipment in
this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon accep­tance of this shipment, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any
visible loss or damage is noted on the freight bill or express receipt, and that the note of loss or damage is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY: Regardless of the extent of the damage.
3. CONCEALED LOSS OR DAMAGE: if damage is unnoticed until the merchandise is unpacked, notify the transportation company or carrier immediately, and file “CONCEALED DAMAGE” claim with them. This must be done within fifteen (15) days from the date the delivery was made to you. Be sure to retain the container for inspection.
Bloomfield Industries cannot assume liability for damage or loss incurred in transit. We will, however, at your request, supply you with the necessary documents to support your claim.
xi
TABLE OF CONTENTS
WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 3 AGENCY APPROVAL INFORMATION 3 INSTALLATION 4 OPERATION 5 CLEANING INSTRUCTIONS 8 TROUBLESHOOTING SUGGESTIONS 10 SERVICING INSTRUCTIONS 11 EXPLODED VIEWS & PARTS LISTS 16 WIRING DIAGRAM 19
SPECIFICATIONS
Thank You for purchasing this Bloomfield Industries appliance.
Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.
This manual contains the information needed to properly install this appliance, and to use, care for and maintain or repair the appliance in a manner which will ensure its optimum performance.
MODEL STYLE VOLTS WATTS
8382 120 VAC 1800 W 15 A NEMA 5-15P
8382OR 120 VAC 1800 W
8382CA k
8382ORCA k
AIRPOT
BREWER
With
FAUCET
120 VAC 1500 W 12.5 A NEMA 5-15P
120 VAC 1500 W 12.5 A NEMA 5-15P
AMPS
POWER SUPPLY
CORD
NEMA 5-15P
k meets Canadian standards
682 75611 Owners Manual 8382 Aquarius™ Airpot Brewer
1
FEATURES AND OPERATING CONTROLS
Fig. 1 Features & Operating Controls
682 75611 Owners Manual 8382 Aquarius™ Airpot Brewer
2
PRECAUTIONS AND GENERAL INFORMATION
WARNING: Electric Shock Hazard
All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock.
WARNING: Injury Hazard
All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical and plumbing codes. Failure could result in property damage and personal injury.
WARNING Electric Shock Hazard
Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious Injury.
WARNING: Burn Hazard
This appliance dispenses very hot liquid. Serious bodily injury from scalding can occur from contact with dispensed liquids.
This appliance is intended for commercial use only.
This appliance is intended for use to brew beverage products for
human consumption. No other use is recommended or
authorized by the manufacturer or its agents.
This appliance is intended for use in commercial establishments,
where all operators are familiar with the appliance use,
limitations and associated hazards. Operating instructions and
warnings must be read and understood by all operators and
users.
Except as noted, this piece of equipment is made in the USA
and has American sizes on hardware. All metric conversions
are approximate and can vary in size.
The following trouble shooting, component views and parts lists
are included for general reference, and are intended for use by
qualified service personnel.
This manual should be considered a permanent part of this
appliance. The manual must remain with the appliance if it is
sold or moved to another location.
AGENC Y APPROVAL I NFORMATI O N
This brewer is and
This brewer meets
682 75611 Owners Manual 8382 Aquarius™ Airpot Brewer
operated and maintained in accordance with the enclosed
listed under UL file E9253.
Standard 4 only when installed,
CAUTION: Equipment Electrical Damage
DO NOT plug in or energize this
appliance until all Installation Instructions are read and followed.
Damage to the Brewer will occur if these instructions are not followed.
CAUTION: Burn Hazard
Exposed surfaces of the appliance, brew chamber and decanter may be HOT to the touch, and can cause serious burns.
E9253
E9253
instructions.
STD 4
3
INSTALLATION INSTRUCTIONS
READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION
IMPORTANT:
To enable the installer to make a quality installation and to minimize installation time, the following suggestions and tests should be done before the actual unit installation is started:
CAUTION: Equipment Electrical Damage
DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed.
CAUTION: Unstable Equipment Hazard
It is very important for safety and for proper operation that the brewer is level and stable when standing in its final operating position. Provided adjustable, non-skid legs must be installed at each corner of the unit. Failure to do so will result in movement of the brewer which can cause personal Injury and/ or damage to brewer.
WARNING ELECTRIC SHOCK HAZARD:
Brewer must be plugged into a properly grounded electrical receptacle to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious injury.
Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit.
Verify that the Spray Head Gasket (#33) and Spray Disk (#34) are properly installed.
LEVELING THE UNIT
Verify that an adjustable leg is installed at each corner of the brewer.
Set Brewer in its operating location. Level the Brewer. A spirit level should be placed on the top of the unit, at the edge, as a guide when making level adjustments.
Level the unit from left to right and front to back by turning the adjustable feet. Be sure all four feet touch the counter to prevent tipping.
FILL WATER TANK
Check the bottle ring for lint or packing materials. Wipe the interior of the bottle ring with a cloth dampened with clean water.
Brewer is designed to use a 3 gallon or 5 gallon plastic water bottle. Carefully insert a fresh water bottle into the bottle ring.
Wait 30 seconds, or until all bubbling in the bottle stops, then drain water from the hot water faucet until all air is purged from the tank.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1 Check the nameplate to determine correct electrical service required for the Brewer to be installed.
IMPORTANT: Before connecting to electricity, make sure a
bottle of water is installed on the bottle ring, and all air has been bled from the water tank
Model 8382 is equipped with a cord and plug. It requires a 115 -
125 volt 20 amp circuit (50/60 Hz, 2 wire plus ground, with NEMA 5-15R or 5-20R Receptacle).
IMPORTANT:
Supply power must match nameplate for voltage and phase. Connecting to the wrong voltage will damage the brewer or result in decreased performance. Such damage is not covered by
warranty. IMPORTANT: The ground prong of the plug is part of a system
designed to protect you from electrical shock in the event of internal damage. Never cut off the ground prong nor twist a blade to fit an existing receptacle. Contact a licensed electrician to install the proper circuit and receptacle.
682 75611 Owners Manual 8382 Aquarius™ Airpot Brewer
4
OPERATION
START-UP
For initial start-up, or if the brewer has not been used for an extended period of time:
Be sure spray disk and brew gasket are properly installed in the brew head. Install a fresh bottle of water in the bottle ring. Allow basin and tank to fill. Plug unit into a properly grounded electrical receptacle. Draw water from the hot water faucet until all air is purged from the tank.
NOTE: This brewer will not function as a “pour-over” brewer. A
water bottle with an adequate amount of water must be installed for the brewer to operate.
Once plugged into electrical power, the heating elements will begin heating the water in the tank. When the water has reached the proper temperature, the “READY TO BREW” light will glow.
682 75611 Owners Manual 8382 Aquarius™ Airpot Brewer
WARNING: Personal Injury
5 Gallon water bottle can weigh up to 50 pounds. Install bottle carefully. Injury can result from improper lifting technique or from attempting to lift a full bottle without adequate physical ability.
CAUTION: Equipment Electrical Damage
DO NOT manually fill brewer through bottle ring.
IMPORTANT: Use only 3 gallon
or 5 gallon plastic water bottle.
IMPORTANT:
Tank must be full of water before connecting brewer to electrical power. Heating elements will be damaged if allowed to operate without being fully submerged in water. Damage caused by operating the brewer without
water in the tank is NOT COVERED BY WARRANTY.
IMPORTANT:
This appliance is NOT designed to be used as a pour-over brewer. Operation without a water bottle with an adequate amount of water in place will produce very little or no brewed coffee.
IMPORTANT:
When installing water bottle, be careful to not overflow the basin pan. DO NOT fill the basin pan prior to installing the water bottle.
Fig 2. Brewer Operation Diagram
5