Bloomfield 412, 482, 443, 471, 472 User Manual

Model: 0482 Airpot Brewer
Model: 0443 Pour-Over Decanter Brewer
OWNERS MANUAL
For
COFFEE BREWERS
MODELS: 0412 Decanter (In-Line) 0443 Decanter (In-Line
Pour-Over) 0471 Decanter (Step-up
Pour Over) 0472 Decanter (Step-Up) 0482 Airpot/Thermal
Server
Includes:
Installation
Operation
Use & Care
Servicing Instructions
685
Model: 0412 In-Line Decanter Brewer
PRINTED IN CHINA
p/n 77110 Rev.D ECN-12903 M685 050809 cps
WARRANTY STATEMENT
All electrical equipment manufactured by BLOOMFIELD INDUSTRIES is warranted against defects in materials and workmanship for a period of one year from the date of original installation or eighteen (18) months from the date of shipment from our factory, whichever comes first, and is for the benefit of the original purchaser, except that: a. airpots carry a 30 day parts warranty only. b. dispensers; i.e., tea and coffee carry a 90 days parts warranty only, excludes decanters.
THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXCLUDED.
BLOOMFIELD INDUSTRIES DIVISION / SPECIALTY EQUIPMENT MANUFACTURING CORPORATION SHALL NOT BE LIABLE FOR INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY CAUSE WHATSOEVER.
This warranty is void if it is determined that upon inspection by an Authorized Service Agency that the equipment has bee n modified, misused, misapplied, improperly installed, or damaged in transit or by fire, flood or act of God.
SERVICE POLICY AND PROCEDURE GUIDE
ADDITIONAL WARRANTY EXCLUSIONS
1. Resetting of safety thermostats, circuit breakers, overload protectors, or fuse replacements unless warranted conditions are the cause.
2. All problems due to operation at voltages other than specified on equipment nameplates; conversion to correct voltage must be the customer’s responsibility.
3. All problems due to electrical connections not made in accordance with electrical code requirements and wiring diagrams supplied with the equipment.
4. Replacement of items subject to normal wear, to include such items as knobs and light bulbs. Normal maintenance
functions including adjustment of thermostats, microswitches,
and replacement of fuses and indicating lights are not
covered under warranty.
5. All problems due to inadequate water supply, such as
fluctuating, or high or low water pressure.
6. All problems due to mineral/calcium deposits, or
contamination from chlorides/chlorines. De-liming is considered a preventative maintenance function and is not covered by warranty.
It also does not apply if the serial nameplate has been removed or unauthorized service personnel perfor m service. The prices charged by Bloomfield Industries for its products are based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to the repair of defects without charge by a Bloomfield Industries Authorized Service Agency or one of its sub-agencies. This service will be provided on customer’s premises for non-portable models. Portable models (a device with a cord and plug) must be taken or shipped to the closest Authorized Service Agency, transportation charges prepaid, for services.
In addition to restrictions contained in this warranty, specific limitations are shown below (Additional W arranty Exclusions). Bloomfield Industries Authorized Service Agencies are located in principal cities.
This warranty is valid in the United States and void elsewhere. Please consult your classified telephone directory or your food service equipment dealer; or, for information and other details concerning warranty, write to:
Phone: (888) 492-2782 Fax: (888) 492-2783
7. Full use, care and maintenance instructions are supplied with each machine. Those miscellaneous adjustments noted are customer responsibility. Proper attention will prolong the life of the machine.
8. Travel mileage is limited to sixty (60) miles from an authorized Service Agency or one of its sub-agencies.
9. All labor shall be performed during normal working hours. Overtime premium shall be charged to the customer.
10. All genuine Bloomfield replacement parts are warranted for ninety (90) days from date of purchase on non­ warranted equipment. Any use of non-genuine Bloomfield parts completely voids any warranty.
11. Installation, labor and job check-out are not considered warranty.
12. Charges incurred by delays, waiting time or operating restrictions that hinder the service technicians ability to perform services are not covered by warranty. This includes institutional and correctional facilities.
Service Parts Department
Bloomfield Industries
P.O. Box 280
Verdi, NV 89439
685 77110 Owners Manual Horizon™ Brewers
SHIPPING DAMAGE CLAIMS PROCEDURE
NOTE: For your protection, please note that equipment in
this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any visible loss or damage is noted on the freight bill or express receipt, and that the note of loss or damage is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY: Regardless of the extent of the damage.
3. CONCEALED LOSS OR DAMAGE: if damage is unnoticed until the merchandise is unpacked, notify the transportation company or carrier immediately, and file “CONCEALED DAMAGE” claim with them. This must be done within fifteen (15) days from the date the delivery was made to you. Be sure to retain the container for inspection.
Bloomfield Industries cannot assume liability for damage or loss incurred in transit. We will, however, at your request, supply you with the necessary documents to support your claim.
xi
TABLE OF CONTENTS
WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 3 AGENCY LISTING INFORMATION 4 INSTALLATION INSTRUCTIONS 5 OPERATION 8 BREWING COFFEE 9 CLEANING INSTRUCTIONS 10 TROUBLESHOOTING SUGGESTIONS 11 SERVICING INSTRUCTIONS 12 Deliming Instructions 17 EXPLODED VIEW & PARTS LIST 18 WIRING DIAGRAMS 26
SPECIFICATIONS
MODEL STYLE FEATURES VOLTS WATTS
0412
k0412CA
AUTOMATIC
DECANTER
IN-LINE
3 WARMER
FAUCET
120
1800 15.0 1500 12.5
Thank You for purchasing this Bloomfield Industries appliance.
Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.
This manual contains the information needed to properly install this appliance, and to use, care for and maintain or repair the appliance in a manner which will ensure its optimum perf ormance.
AMPS
POWER SUPPLY
CORD
NEMA 5-15P
0443
k0443CA
0471
k0471CA
0472
k0472CA
0482
k0482CA
k meets Canadian Standards
POUR-OVER
DECANTER
IN-LINE
POUR-OVER
DECANTER
STEP-UP
AUTOMATIC
DECANTER
STEP-UP
AUTOMATIC
AIRPOT
2 WARMER 120
3 WARMER 120
3 WARMER
FAUCET
FAUCET 120
120
APPLICABILITY
685 77110 Owners Manual Horizon™ Brewers
This manual applies to the following Bloomfield Industries products: 0412 0443 0471 0472 0482
1700 14.2
NEMA 5-15P
1400 11.6 1800 15.0
NEMA 5-15P
1500 12.5 1800 15.0
NEMA 5-15P
1500 12.5 1800 15.0
NEMA 5-15P
1500 12.5
1
FEAT U R E S AN D OP E RATING CO N T ROLS - AUTOMATIC BREWERS
Fig. 1 Features & Operating Controls for Automatic Brewers
2
685 77110 Owners Manual Horizon™ Brewers
FEATURES AND OPERATING CONTROLS - POUR-OVER BREWERS
685 77110 Owners Manual Horizon™ Brewers
Fig. 2 Features & Operating Controls for Pour-Over Brewers
3
PRECAUTIONS AND GENERAL INFORM ATION
WARNING: ELECTRIC SHOCK HAZARD
All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools.
Failure to heed this warning can result in electrical shock.
WARNING: INJURY HAZARD
All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical and plumbing codes. Failure could result in property damage and personal injury.
WARNING: ELECTRIC SHOCK HAZARD
Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious Injury.
WARNING: BURN HAZARD
This appliance dispenses very hot liquid. Serious bodily injury from scalding can occur from contact with dispensed liquids.
CAUTION:
ELECTRICAL DAMAGE
DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed.
CAUTION:
BURN HAZARD
Exposed surfaces of the appliance, brew chamber and airpot ,decanter or thermal server may be HOT to the touch, and can cause serious burns.
AGENCY LISTING INFORMATION
E9253
STD 4
E9253
This appliance is intended for commercial use only. This appliance is intended for use to brew beverage products for
human consumption. No other use is recommended or authorized by the manufacturer or its agents.
This appliance is intended for use in commercial establishments, where all operators are familiar with the appliance use, limitations and associated hazards. Operating instructions and warnings must be read and understood by all operators and users.
The following trouble shooting, component views and parts lists are included for general reference, and are intended for use by qualified service personnel.
This manual should be considered a permanent part of this appliance. The manual must remain with the appliance if it is sold or moved to another location.
This brewer is and listed under UL file E9253.
This brewer meets operated and maintained in accordance with the enclosed instructions.
685 77110 Owners Manual Horizon™ Brewers
Standard 4 only when installed,
4
INSTALLATION
READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION
Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit.
Verify that the Spray Head Gasket and Spray Disk are properly installed.
LEVELING THE UNIT
Verify that an adjustable leg is installed at each corner of the brewer.
NOTE: Various combinations of legs and spacers are available for Model 0482 airpot brewer. The total combination of legs and spacers must be equal for all four corners.
Set Brewer in its operating location. Level the Brewer. A spirit level should be placed on the top of the unit, at the edge, as a guide when making level adjustments.
Level the unit from left to right and front to back by turning the adjustable feet. Be sure all four feet touch the counter to prevent tipping.
IMPORTANT:
To enable the installer to make a quality installation and to minimize installation time, the following suggestions and tests should be done before the actual unit installation is started:
CAUTION:
ELECTRICAL
DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed.
DAMAGE
CAUTION:
UNSTABLE
It is very important for safety and for proper operation that the brewer is level and stable when standing in its final operating position. Provided adjustable, feet or legs must be installed at each corner of the unit. Failure to do so will result in movement of the brewer which can cause personal Injury and/or damage to brewer.
EQUIPMENT HAZARD
685 77110 Owners Manual Horizon™ Brewers
5
INSTALLATION (continued)
READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION
CAUTION:
ELECTRICAL
DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed.
IMPORTANT:
Tank must be full of water before connecting brewer to electric power. Heating elements will be damaged if allowed to operate without being fully submerged in water. See instructions for filling tank, page 8. Damage caused by operating the brewer withou t water in the tank is NOT COVERED BY WARRANTY.
NOTE: Water supply inlet line must mee t cer tain minimu m criteria to insure successful operation of the brewer. Bloomfield recommends 1/4" copper tubing for installation of less than 12 feet and 3/8" for more than 12 feet from a 1/2" water supply line.
NOTE: This equipment must be installed to comply with applicable federal, state and local plumbing codes and ordinances.
DAMAGE
PLUMBER’S INSTALLATION INSTRUCTIONS (AUTOMATIC BREWERS)
Brewer should be connected to a POTABLE WATER, COLD WATER line. Flush water line before connecting to Brewer.
DO NOT use a saddle valve with a self-piercing tap for the water line connection. Such a tap can become restricted by waterline debris. For systems that must use a saddle tap, shut off the main water supply and drill a 3/16” (minimum) tap for the saddle connection, in order to insure an ample water supply. Remember to flush the line prior to installing the saddle.
The brewer must be installed on a water line with average pressure between 20 PSI and 90 PSI. If your water pressure exceeds 90 PSI at anytime, a pressure regulator must be installed in the water supply line to limit the pressure to not more than 90 PSI in order to avoid damage to lines and solenoid.
A water shut-off valve should be installed on the incoming water line in a convenient location (Use a low restriction type valve, such as a 1/4-turn ball valve, to avoid loss of water flow thru the valve.
NSF requires that the brewer be able to be moved for cleaning underneath. Loops of copper tubing will satisfy this requirement. See Figure 3 below.
Fig. 3 Water Supply Installation
In some areas, local codes require a backflow preventer (check valve) to be installed on the inlet water line. If a backflow preventer is used, you must install a water hammer arrester in the incoming line, between the backflow preventer and the brewer inlet, as far away from the brewer as space will allow. This will relieve the excessive back pressures that can cause faucet leaks and solenoid malfunctions.
685 77110 Owners Manual Horizon™ Brewers
6
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1 Check the nameplate to determine correct electrical service required for the Brewer to be installed.
IMPORTANT: Before connecting to electricity, make sure automatic brewers are connected to the water supply.
NOTE: Does not apply to 0443 and 0471 pour-over brewers. All models are equipped with a cord and plug. They require a
115 - 125 volt 20 amp circuit (50/60 Hz, 2 wire plus ground, with NEMA 5-15R or 5-20R Receptacle).
See Figure 4 at right.
INSTALLATION (continued)
WARNING:
SHOCK HAZARD
Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious injury.
IMPORTANT:
Supply power must match nameplate for voltage and phase. Connecting to the wrong voltage will damage the brewer or result in decreased performance. Such damage is not covered by warranty.
IMPORTANT: Do not connect brewer to electrical power until you have filled the tank. See instructions on page 8.
IMPORTANT:
The ground prong of the plug is part of a system designed to protect you from electrical shock in the event of internal damage. Never cut off the ground prong nor twist a blade to fit an existing receptacle. Contact a licensed electrician to install the proper circuit and receptacle.
GROUND
PIN
NEMA 5-15P
PLUG
NEMA 5-15R
RECEPT ACLE
Fig. 4 Power Supply Plug
685 77110 Owners Manual Horizon™ Brewers
7
Loading...
+ 21 hidden pages