Blodgett ZEPHAIRE 240G PLUS User Manual

ZEPHAIREĆ240G PLUS
CONVECTION OVEN
INSTALLATION - OPERATION - MAINTENANCE
ZEPHAIREĆ240G PLUS
MANUEL D'INSTALLATION - FONCTIONNEMENT - ENTRETIEN
BLODGETT OVEN COMPANY
www.blodgett.com
44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone (800) 331Ć5842, (802) 860Ć3700 Fax: (802)864Ć0183
PN 52898 Rev A (8/09)
E 2009 - G.S. Blodgett Corporation
IMPORTANT
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT
AVERTISSEMENT: UNE INSTALLATION, UN AJUSTEMENT, UNE ALTÉRATION, UN SERVICE OU UN ENTRETIEN NON CONFORME AUX NORMES PEUT CAUSER DES DOMMAGES À LA PROPRIÉTE, DES BLESSURES OU LA MORT. LISEZ ATTENTIVEĆ MENT LES DIRECTIVES D'INSTALLATION, D'OPÉRATION ET D'ENTRETIEN AVANT DE FAIRE L'INSTALLATION OU L'ENTRETIEN DE CET ÉQUIPEMENT.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS MUST BE POSTED IN A PROMINENT LOCATION. THIS INFORMATION MAY BE OBTAINED BY CONTACTING YOUR LOCAL GAS SUPPLIER.
LES INSTRUCTIONS À RESPECTER AU CAS OÙ L'UTILISATEUR PERÇOIT UNE ODEUR DE GAZ DOIVENT ÊTRE AFFICHÉES DANS UN ENDROIT BIEN VISIBLE. VOUS POUVEZ VOUS LES PROCURER AUPRÈS DE VOTRE FOURNISSEUR DE GAZ LOCAL.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
AVERTISSEMENT
Ne pas entreposer ni utiliser de l'essence ni d'autres vapeurs ou liquides inflamĆ mables dans le voisinage de cet appariel, ni de tout autre appareil.
The information contained in this manual is important for the proper installation, use, and maintenance of this oven. Adherence to these procedures and instrucĆ tions will result in satisfactory baking results and long, trouble free service. Please read this manual carefully and retain it for future reference.
Les informations données dans le présent manuel sont importantes pour installer, utiliser et entretenir correctement ce four. Le respect de ces instructions et procéĆ dures permettra d'obtenir de bons résultats de cuisson et une longue durée de serĆ vice sans problèmes. Veuillez lire le présent manuel et le conserver pour pouvoir vous y reporter à l'avenir.
Errors: Descriptive, typographic or pictorial errors are subject to correction. SpecificaĆ
tions are subject to change without notice.
Erreurs:Les erreurs de description, de typographie ou d'illustration font l'objet de
corrections. Les caractéristiques sont sujettes à modifications sans préavis.
THE REPUTATION YOU CAN COUNT ON
UNE RÉPUTATION SUR LAQUELLE VOUS POUVEZ COMPTER
For over a century and a half, The Blodgett Oven Company has been building ovens and nothing but ovens. We've set the industry's quality standard for all kinds of ovens for every foodservice operation regardless of size, application or budget. In fact, no one offers more models, sizes, and oven applications than Blodgett; gas and electric, fullĆsize, halfĆsize, countertop and deck, conĆ vection, Cook'n Hold, CombiĆOvens and the industry's highest quality Pizza Oven line. For more information on the full line of Blodgett ovens contact your Blodgett representative.
Cela fait maintenant dessus un siècle et demi que Blodgett se spécialise dans la fabrication de fours. Nous avons établi les normes de qualité qui s'appliĆ quent dans l'industrie à tous les types de fours utilisés dans les services aliĆ mentaires, quel qu'en soit la taille, l'exploitation ou le budget. En fait, ni n'offre plus de modèles, de tailles et d'applications de fours que Blodgett. À gaz et électriques. De tailles différentes, sur plan de travail et superposables. Qu'il s'agisse de fours à convection, des modèles Cook'n Hold et CombiĆOven, ou de la gamme de fours à pizzas de la plus haute qualité offerte sur le marché. Pour de plus amples informations sur la gamme complète de fours Blodgett, veuillez contacter votre représentant Blodgett.
Your Service Agency's Address: Adresse de votre agence de service:
Model/Modèl:
Serial Number/Numéro de série:
Your oven was installed by/ Installateur de votre four:
Your oven's installation was checked by/ Contrôleur de l'installation de votre four:
Table of Contents/Table des Matières
Installation
Oven Description and Specifications 2. . . .
Delivery and Location 3. . . . . . . . . . . . . . . . .
Utility Connections -
Standards and Codes 4. . . . . . . . . . . . . . . . .
Oven Assembly 5. . . . . . . . . . . . . . . . . . . . . .
NSF Bolts 5. . . . . . . . . . . . . . . . . . . . . . . . . .
Leg Attachment 6. . . . . . . . . . . . . . . . . . . . .
Caster Assembly 6. . . . . . . . . . . . . . . . . . . .
Double Section Assembly 7. . . . . . . . . . . .
Oven Leveling 7. . . . . . . . . . . . . . . . . . . . . .
Ventilation 8. . . . . . . . . . . . . . . . . . . . . . . . . . .
Canopy Type Exhaust Hood 8. . . . . . . . . .
Direct Flue Arrangement 9. . . . . . . . . . . . .
Gas Connection 10. . . . . . . . . . . . . . . . . . . . . .
Electrical Connection 13. . . . . . . . . . . . . . . . .
Initial Startup 14. . . . . . . . . . . . . . . . . . . . . . . . .
Operation
Safety Information 15. . . . . . . . . . . . . . . . . . . .
Oven Control 16. . . . . . . . . . . . . . . . . . . . . . . . .
General Guidelines for Operating
Personnel 17. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Suggested Times and Temperatures 18. . . .
Maintenance
Cleaning and Preventative Maintenance 19.
Troubleshooting Guide 20. . . . . . . . . . . . . . . .
Installation
Description et Spécifications du Four 22. . . .
Livraison et Implantation 23. . . . . . . . . . . . . . .
Branchements de Service - Normes et
Codes 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Montage du Four 25. . . . . . . . . . . . . . . . . . . . .
Boulons NSF 25. . . . . . . . . . . . . . . . . . . . . . .
Assemblage des Pieds 26. . . . . . . . . . . . . . .
Montage des Roulettes 26. . . . . . . . . . . . . .
Montage de la Section Double 27. . . . . . . .
Mise à Niveau du Four 27. . . . . . . . . . . . . . .
Ventilation 28. . . . . . . . . . . . . . . . . . . . . . . . . . .
Hotte D'évacuation Type Voûte 28. . . . . . .
En Prise Directe 29. . . . . . . . . . . . . . . . . . . . .
Branchement de Gaz 30. . . . . . . . . . . . . . . . .
Raccordement Électrique 33. . . . . . . . . . . . . .
Mise en Marche Initiale 34. . . . . . . . . . . . . . . .
Utilisation
Informations de Sécurité 35. . . . . . . . . . . . . . .
Commande de Four 36. . . . . . . . . . . . . . . . . .
Consignes Générales à l'Intention des
Utilasateurs 38. . . . . . . . . . . . . . . . . . . . . . . . . .
Durées et Températures Suggérées 39. . . . .
Entretien
Nettoyage et Entretien Préventif 40. . . . . . . .
Guide de Détection des Pannes 41. . . . . . . .
Installation
Oven Description and Specifications
Cooking in a convection oven differs from cooking in a conventional deck or range oven since heated air is constantly recirculated over the product by a fan in an enclosed chamber. The moving air conĆ tinually strips away the layer of cool air surroundĆ ing the product, quickly allowing the heat to peneĆ trate. The result is a high quality product, cooked at a lower temperature in a shorter amount of time.
Blodgett convection ovens represent the latest adĆ vancement in energy efficiency, reliability, and ease of operation. Heat normally lost, is recircuĆ lated within the cooking chamber before being vented from the oven: resulting in substantial reĆ ductions in energy consumption and enhanced oven performance.
Air Flow Pattern for Blodgett Convection Ovens
Figure 1
GAS SPECIFICATIONS - ZEPHAIRE-240G
Natural Gas Propane Gas
US Units SI Units US Units SI Units
Heating Value 1000 BTU/cu. ft. 37.3 MJ/m Specific Gravity (air=1.0) 0.63 0.63 1.53 1.53 Oven Input 50,000 BTU/hr 14.6 kW 50,000 BTU/hr 14.
Main Burner Orifice Size 42 MTD* 2.4 mm 0.055 dia 1.4 mm
* MTD - Multiple Twist Drill
3
2550 BTU/cu. ft. 95.0 MJ/m
63 kW
3
2
Installation
Delivery and Location
DELIVERY AND INSPECTION
All Blodgett ovens are shipped in containers to prevent damage. Upon delivery of your new oven:
D Inspect the shipping container for external damĆ
age. Any evidence of damage should be noted on the delivery receipt which must be signed by the driver.
D Uncrate the oven and check for internal damĆ
age. Carriers will accept claims for concealed damage if notified within fifteen days of delivery and the shipping container is retained for inĆ spection.
The Blodgett Oven Company cannot assume responsibility for loss or damage suffered in transit. The carrier assumed full responsibility for delivery in good order when the shipment was accepted. We are, however, prepared to assist you if filing a claim is necessary.
OVEN LOCATION
The well planned and proper placement of your oven will result in long term operator convenience and satisfactory performance.
The following clearances must be maintained beĆ tween the oven and any combustible or nonĆcomĆ bustible construction.
D Oven body right side - 2" (51 cm) D Oven body left side - 2" (51 cm) D Oven body back - 0" (0 cm)
The following clearances must be available for serĆ vicing.
D Oven body sides - 12" (30 cm) D Oven body back - 12" (30 cm)
NOTE: On gas models, routine servicing can usuĆ
ally be accomplished within the limited movement provided by the gas hose reĆ straint. If the oven needs to be moved furĆ ther from the wall, the gas must first be turned off and disconnected from the oven before removing the restraint. Reconnect the restraint after the oven has been reĆ turned to its normal position.
It is essential that an adequate air supply to the oven be maintained to provide a sufficient flow of combustion and ventilation air.
D Place the oven in an area that is free of drafts. D Keep the oven area free and clear of all combusĆ
tibles such as paper, cardboard, and flammable liquids and solvents.
D Do not place the oven on a curb base or seal to
a wall. This will restrict the flow of air and prevent proper ventilation. Tripping of the blower moĆ tor's thermal overload device is caused by an excessive ambient temperature on the right side of the oven. This condition must be corĆ rected to prevent permanent damage to the oven.
D The location must provide adequate clearance
for the air opening into the combustion chamĆ ber.
Before making any utility connections to this oven, check the rating plate to be sure the oven specifiĆ cations are compatible with the gas and electrical services supplied for the oven.
1. Remove the combustion compartment cover. The rating plate is attached to the frame on the left side of the combustion compartment.
3
Installation
Utility Connections - Standards and Codes
THE INSTALLATION INSTRUCTIONS CONĆ TAINED HEREIN ARE FOR THE USE OF QUALIĆ FIED INSTALLATION AND SERVICE PERSONNEL ONLY. INSTALLATION OR SERVICE BY OTHER THAN QUALIFIED PERSONNEL MAY RESULT IN DAMAGE TO THE OVEN AND/OR INJURY TO THE OPERATOR.
Qualified installation personnel are individuals, a firm, a corporation, or a company which either in person or through a representative are engaged in, and responsible for:
D the installation or replacement of gas piping
and the connection, installation, repair or servĆ icing of equipment.
D the installation of electrical wiring from the elecĆ
tric meter, main control box or service outlet to the electric appliance.
Qualified installation personnel must be experiĆ enced in such work, familiar with all precautions required, and have complied with all requirements of state or local authorities having jurisdiction.
U.S. and Canadian installations
Installation must conform with local codes, or in the absence of local codes, with the National Fuel
Gas Code, NFPA54/ANSI Z223.1-Latest Edition, the Natural Gas Installation Code CAN/CGAĆ B149.1 or the Propane Installation Code, CAN/ CGAĆB149.2 as applicable.
Installation must conform with local codes, or in the absence of local codes, with the National ElecĆ
trical Code, ANSI/NFPA 70-Latest Edition and/or Canadian National Electric Code C22.2 as applicaĆ
ble. Appliance is to be installed with backflow prevenĆ
tion in accordance with applicable federal, provĆ ince and local codes.
General export installations
Installation must conform with Local and National installation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the proper installation and/or operation of your Blodgett oven, please contact your local distributor. If you do not have a local disĆ tributor, please call the Blodgett Oven Company at 0011Ć802Ć860Ć3700.
4
Installation
Oven Assembly
NSF BOLTS
These bolts are required by NSF to block any exĆ posed hole on the back of an oven. This includes:
D any unit, single or stacked, without a back panel.
D any holes in stacked units not used for mountĆ
ing stacking brackets.
1. Locate the 5/16" bolts that were shipped with the oven.
2. Install the bolts as shown in Figure 2.
Double Stacked Units Units without back panels
Figure 2
5
Installation
Oven Assembly
LEG ATTACHMENT
1. Push the oven onto a lift with the bottom of the oven down.
2. Align the threaded stud in each leg with the nut located inside each bottom corner of the oven frame. Turn the legs clockwise and tightĆ en to the nearest full turn.
3. Align the two leg plate holes in each leg with those in the oven bottom. Secure each leg usĆ ing two 1/2" bolts.
NOTE: If using casters see CASTER ASĆ
SEMBLY before proceeding.
4. Level the oven by screwing the adjustable leg feet in or out as necessary.
CASTER ASSEMBLY
NOTE: Install the locking casters on the front of
the oven. Install the nonĆlocking casters on the back of the oven.
NOTE: Use a gas hose restraint on all units with
casters. See page 12.
Casters for Single and Double Stacked Ovens:
1. Attach the legs as described.
2. Pry the adjustable feet out of the legs.
3. Insert one caster into each leg as shown. Tighten the large hex nut to secure the castĆ ers.
Adjustable
Leg Foot
Caster Assembly
6" (15 cm) Legs Shown
Figure 3
Figure 4
Low Profile Casters for Double Stacked Ovens:
1. Align the three holes in each caster assembly plate with those in the oven bottom. Secure each caster using three 1/2" bolts.
Figure 5
6
Installation
Oven Assembly
DOUBLE SECTION ASSEMBLY
1. Secure the short legs to the bottom sections as described.
2. Place the upper section in position on top of the lower oven.
3. Attach the stacking brackets using the reĆ maining 5/16" bolts shipped with the ovens.
4. Attach the flue connector.
WARNING!! When stacking ovens be sure to remove
the single oven flue boxes prior to attachĆ ing threeĆpiece connector.
OVEN LEVELING
After assembly, the oven should be leveled and moved to the operating location.
1. The oven can be leveled by adjusting the feet or casters located on the bottom of each leg.
Figure 6
7
Flue
Connector
Installation
Ventilation
On gas models the installation of a proper ventilaĆ tion system cannot be over emphasized. This sysĆ tem removes unwanted vapors and products of combustion from the operating area.
This oven may be vented using either:
D A mechanically driven, canopy type, exhaust
hood, or
D A direct flue arrangement.
U.S. and Canadian installations
Refer to your local ventilation codes. In the abĆ sence of local codes, refer to the National ventilaĆ tion code titled, Standard for the Installation of
Equipment for the Removal of Smoke and Grease Laden Vapors from Commercial Cooking EquipĆ ment", NFPAĆ96ĆLatest Edition.
Australia and general export installations
Installation must conform with Local and National installation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the proper installation and/or operation of your Blodgett oven, please contact your local distributor. If you do not have a local disĆ tributor, please call the Blodgett Oven Company at 0011Ć802Ć860Ć3700.
CANOPY TYPE EXHAUST HOOD
A mechanically driven, canopy type exhaust hood is the preferred method of ventilation.
The hood should be sized to completely cover the equipment plus an overhang of at least 6" (15 cm) on all sides not adjacent to a wall. The distance from the floor to the lower edge of the hood should not exceed 7' (2.1m).
The total makeup and exhaust air requirements for hood capacity should be approximately 30 CFM (.85 m3) for each oven section.
Installing the canopy hood draft diverter
Ovens ordered for hood venting are supplied with a draft diverter. Install the draft diverter as follows:
1. Place the diverter over the flue connector with the open area facing the front of the oven. See Figure 7.
2. Secure both ends with the sheet metal screws provided.
Draft Diverter
WARNING: Failure to properly vent the oven can be
hazardous to the health of the operator and may result in operational problems, unsatisfactory baking and possible damĆ age to the equipment.
Damage sustained as a direct result of imĆ proper ventilation will not be covered by the manufacturer's warranty.
Front of
Oven
Figure 7
8
Installation
Ventilation
DIRECT FLUE ARRANGEMENT
When the installation of a mechanically driven exĆ haust hood is impractical the oven may be vented by a direct flue arrangement.
WARNING!! It is essential that the direct flue be
installed as follows. Incorrect installation will result in unsatisfactory baking and oven damage.
The flue must be class B or better with a diameter of 6" (15 cm). The height of the flue should rise 6Ć8 ft (2Ć2.5 m) above the roof of the building or any proximate structure. Never direct vent the oven into a hood. The flue should be capped with a UL Listed type vent cap to isolate the unit from exterĆ nal environmental conditions.
The direct vent cannot replace air consumed and vented by the oven. Provisions must be made to supply the room with sufficient makeĆup air. Total makeĆup air requirements for each oven section should be approximately 30 CFM (.85m3) per secĆ tion. To increase the supply air entering the room, a ventilation expert should be consulted.
Installing the draft hood
Ovens ordered for direct venting are supplied with a draft hood. Install the draft hood as follows:
1. Place the draft hood over the flue connector.
See Figure 8.
2. Secure both ends with the sheet metal screws
provided.
Flue
Draft Hood
Front of
Oven
Figure 8
9
Installation
p
pg
Gas Connection
GAS PIPING
A properly sized gas supply system is essential for maximum oven performance. Piping should be sized to provide a supply of gas sufficient to meet the maximum demand of all appliances on the line without loss of pressure at the equipment.
Example:
NOTE: BTU values in the following example are
for natural gas.
You purchase a ZephaireĆG convection oven to add to your existing cook line.
1. Add the BTU rating of your current appliances. Pitco Fryer 120,000 BTU
6 Burner Range 60,000 BTU Deck Oven 50,000 BTU Total 230,000 BTU
2. Add the BTU rating of the new oven to the toĆ tal.
Previous Total 230,000 BTU ZephaireĆ240G 50,000 BTU New Total 280,000 BTU
3. Measure the distance from the gas meter to the cook line. This is the pipe length. Let's say the pipe length is 40' (12.2 m) and the pipe size is 1" (2.54 cm).
4. Use the appropriate table to determine the toĆ tal capacity of your current gas piping.
The total capacity for this example is 320,000 BTU. Since the total required gas pressure, 280,000 BTU is less than 320,000 BTU, the current gas piping will not have to be inĆ creased.
NOTE: The BTU capacities given in the tables are
for straight pipe lengths only. Any elbows or other fittings will decrease pipe capaciĆ ties. Contact your local gas supplier if you have any questions.
Maximum Capacity of Iron Pipe in Cubic Feet
of Natural Gas Per Hour
(Pressure drop of 0.5 Inch W.C.)
Pipe
Length (ft)
10 360 680 1400 2100 3950 20 250 465 950 1460 2750 30 200 375 770 1180 2200 40 170 320 660 990 1900 50 151 285 580 900 1680 60 138 260 530 810 1520 70 125 240 490 750 1400 80 118 220 460 690 1300 90 110 205 430 650 1220
100 103 195 400 620 1150
From the National Fuel Gas Code Part 10 Table 10Ć2
Maximum Capacity of Pipe in Thousands of
BTU/hr of Undiluted L.P. Gas at 11" W.C.
(Pressure drop of 0.5 Inch W.C.)
Pipe Length
(ft)
10 608 1146 3525 20 418 788 2423 30 336 632 1946 40 287 541 1665 50 255 480 1476 60 231 435 1337 70 215 404 1241 80 198 372 1144 90 187 351 1079
100 175 330 1014
From the National Fuel Gas Code Part 10 Table 10Ć15
Nominal Size, Inches
3/4" 1" 1Ć1/4" 1Ć1/4" 2"
Outside Diameter, Inches 3/4" 1" 1Ć1/2"
10
Loading...
+ 32 hidden pages