Blodgett XR8-G User Manual

XR8-G
MINI RACK OVEN
INSTALLATION -- OPERATION -- MAINTENANCE
XR8-G
MINI RACK OVEN
BLODGETT OVEN COMPANY
www.blodgett.com
44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone (800) 331-5842, (802) 860-3700 Fax: (802)864-0183
PN 38480 Rev A (8/05)
E 2005 --- G.S. Blodgett Corporation
IMPORTANT
WARNING: IMPROPER INSTALLA TION, ADJUSTMENT, AL TERATION, SERVICE OR MAINTENAN C E CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH.READ THE INSTALLA TION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT
AVERTISS EMENT: UNE INSTALLATION, UN AJUSTEMENT, UNE ALTÉRATI O N , UN SERVICE OU UN ENTRETIENNON CONFORME AUX NORMES PEUT CAUSERDES DOMMAGESÀ LA PROPRIÉTE,DES BLESSURES OU LA MORT. LISEZ ATTENTIV E­MENT LES DIRECTI V ESD’INSTALLA TI ON, D’OPÉRA TI ON ET D’ENTRETIEN AV A N T DE FAIRE L’INS TALLATION OU L’ENTRETIEN DE CET ÉQUIPEMENT.
INSTRUCTIONS (PAGE 12) TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS MUST BE POSTED IN A PROMINENT LOCATION. THIS INFORMA­TION MAY BE OBTAINED BY CONTACTING YOUR LOCAL GAS SUPPLIER.
LESINSTRUCTIONS (PAGE12)À RESPECTERAUCASOÙ L’UTILISATEUR PER­ÇOIT UNE ODEUR DE GAZ DOIVENT ÊTRE AFFICHÉES DANS UN ENDROIT BIEN VISIBLE. VOUS POUVEZ VOUS LES PROCURER AUPRÈS DE VOTRE FOURNIS­SEUR DE GAZ LOCAL.
FORYOURSAFETY
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
AVERTISSEMENT
Ne pas entreposer ni utiliser de l’essence ni d’autres vapeurs ou liquides inflam­mables dans le voisinage de cet appariel, ni de tout autre appareil.
The information contained in this manual is important for the proper installation, use, and maintenance of this oven. Adherence to these procedures and instruc­tions will result in satisfactory baking results and long, trouble free service. Please read this manual carefully and retain it for future reference.
Les informatio n s données dans le présent manuel sont importantes pour installer, utiliser et entret enir correctement ce four. Le respect de ces instructio n s et procé­dures permettra d’obtenir de bonsrésultats de cuisson et une longue durée de ser­vice sans problèmes. Veuillez lire le présent manuel et le conserver pour pouvoir vous y reporter à l’avenir.
Errors: Descriptive, typographic or pictorial errors are subject to correction. Specifica-
tions are subject to change without notice.
Erreurs:Les erreurs de description, de typographie ou d’illustration font l’objet de
corrections. Les caractéristiques sont sujettes à modifications sans préavis.
THE REPUTATION YOU CAN COUNT ON
UNE RÉPUTATION SUR LAQUELLE VOUS POUVEZ COMPTER
For over a century and a half, The Blodgett Oven Company has been building ovens and nothing but ovens. We’ve set the industry’s quality standard for all kinds of ovens for every foodservice operation regardless of size, application or budget. In fact, no one offers more models, sizes, and oven applications than Blodgett; gas and electric, full-size, half-size, countertop and deck, con­vection, Cook’n Hold, Combi-Ovens and the industry’s highest quality Pizza Oven line. For more information on the full line of Blodgett ovens contact your Blodgett representative.
Cela fait maintenant dessus un siècle et demi que Blodgett se spécialise dans la fabrication de fours. Nous avons établi les normes de qualité qui s’appli­quent dans l’industrie à tous les types de fours utilisés dans les services ali­mentaires, quel qu’en soit la taille,l’exploitation ou le budget. En fait, ni n’offre plus de modèles, de tailles et d’applications de fours que Blodgett. À gaz et électriques. De tailles différentes, sur plan de travail et superposables. Qu’il s’agisse de fours à convection, des modèles Cook’n Hold et Combi-Oven, ou de la gamme de fours à pizzas de la plus haute qualité offerte sur le marché. Pour de plus amples informations sur la gamme complète de fours Blodgett, veuillez contacter votre représentant Blodgett.
Your Service Agency’s Address: Adressedevotreagencedeservice:
Model/Modèle:
Serial Number/Numéro de série:
Your oven was installed by/ Installateur de votre four:
Your oven’s installation was checked by/ Contrôleur de l’installation de votre four:
Table of Contents/Table des Matières
Introduction
Oven Description and Specifications 2....
Installation
Delivery and Location 3.................
Oven Assembly 4......................
Assembly to Stand 4..................
Assembly to Optional Proofer 4.........
Ventilation 5...........................
Utility Connections ---
Standards and Codes 6.................
Gas Connection 7......................
Plumbing and Electrical Connections 10...
Initial Startup 11.........................
Operation
Safety Information 12....................
Standard Control 13.....................
General Guidelines for
Operating Personnel 15..................
Introduction
Description et Spécifications du Four 18....
Installation
Livraison et Implantation 19...............
Montage du Four 20.....................
Assembly to stand 20..................
Assembly to optional proofer 20.........
Ventilation 21...........................
Branchements de Service ---
Normes et Codes 22.....................
Branchement de Gaz 23.................
Raccordement Électrique et Plomberie 26..
Mise en Marche Initiale 27................
Utilisation
Informations de Sécurité 28...............
Standard Control 29.....................
Consignes Générales à l’Intention
des Utilasateurs 31......................
Maintenance
Cleaning and Preventative Maintenance 16.
Troubleshooting Guide 17................
Entretien
Nettoyage et Entretien Préventif 32........
GuidedeDétectiondesPannes 33........
Introduction
Oven Description and Specifications
The Blodgett Mini-Rack oven features a continu­ously rotating eight pan rack and unique airflow system that moves large amounts of air at low ve­locity to ensure a consistently even bake. The Blodgett rack slide sytem allows the operator to quickly adjust slide spacing from 1 to 4 inches in
GAS SPECIFICATIONS -- XR8-G/AA
Natural Gas Propane Gas
US Units SI Units US Units SI Units
Heating Value 1000 BTU/cu. ft. 37.3 MJ/m
Specific Gravity (air=1.0) 0.63 0.63 1.53 1.53
Gas Manifold Pressure 3.5” W.C. .87 kPa 10” W.C. 2.5 kPa
Oven Input 110,000 BTU/hr 32 kW
Main Burner Orifice Size:
Six burners are Two burners are
.07” dia.
.061” dia.
PLUMBING SPECIFICATIONS -- XR8-G/AA
any configuration. In addition, the Mini-Rack oven is capable of producing large volumes of steam for bagels or similar products.
3
2550 BTU/cu. ft. 95.0 MJ/m
110,000 BTU/hr 32 kW
116 MJ/hr
1.7 mm
1.5 mm
.043” dia. .038” dia.
116 MJ/hr
1.0 mm
0.96 mm
3
Water
Water Pressure 30 PSI (21 kPa) minimum
75 PSI (52 kPa) maximum
Water Connection 3/4” MGHT
Flow Rate 1.12 gallon/minute (4.24 litre/minute) minimum
Drainage
Drain Connection 3/4” rear drain to air gap drain
2
Installation
Delivery and Location
DELIVERY AND INSPECTION
All Blodgett ovens are shipped in containers to prevent damage. Upon delivery of your new oven:
D Inspectthe shipping container for external dam-
age. Any evidence of damage should be noted on the delivery receipt which must be signed by the driver.
D Uncrate the oven and check for internal dam-
age. Carriers will accept claims for concealed damage if notified within fifteen days of delivery and the shipping container is retained for in­spection.
The Blodgett Oven Company cannot assume responsibility for loss or damage suffered in transit. The carrier assumed full responsibility for delivery in good order when the shipment was accepted. We are, however, prepared to assist you if filing a claim is necessary.
OVEN LOCATION
The well planned and proper placement of your oven will result in long term operator convenience and satisfactory performance.
The following clearances must be maintained be ­tween the oven and any combustible or non-com­bustible construction.
D Oven body right side --- 0” (0 cm) D Oven body left side --- 0” (0 cm) D Oven body back --- 0” (0 cm) D Oven top --- 12” (30.5 cm)
The following clearances must be available for ser­vicing.
D Oven body sides --- 12” (30 cm) D Oven body back --- 12” (30 cm) D Oven top --- 12” (30.5 cm)
NOTE: On gas models, routine servicing can usu -
ally be accomplished within the limited movement provided by the gas hose re­straint. If the oven needs to be moved fur ­ther from the wall, the gas must first be turned off and disconnected from the oven before removing the restraint. Reconnect the restraint after the oven has been re­turned to its normal position.
It is essential that an adequate air supply to the oven be maintained to provide a sufficient flow of combustion and ventilation air.
D Place the oven in an area that is free of drafts. D Keep the oven area free and clear of a ll combus-
tibles such as paper, cardboard, and flammable liquids and solvents.
D Do not place the oven on a curb base or sea l to
a wall. This will restrict the flow of air and prevent proper ventilation. Tripping of the blower mo­tor’s thermal overload device is caused by an excessive ambient temperature on the right side of the oven. This condition must be cor­rected to prevent permanent damage to the oven.
D The location must provide adequate clearance for
the air opening into the burners.
Before making any utility connections to this oven, check the rating plate to be sure the oven specifi­cations are compatible with the gas and electrical services supplied for the oven.
1. The rating plate is located behind the control panel.
2. Remove the two screws on the rightside of the control panel.
3. Pull the control panel toward the right side of the oven.
4. Pull the control panel away from the oven and rotate out.
5. Reverse steps 2-4 to close the control panel.
3
Installation
Oven Assembly
ASSEMBLY TO STAND
1. Center the oven frame on top of the stand so that the oven overhangs at both the front and back. See Figure 1.
2. Remove the three screws at the top of the left and right side panels of the oven. Remove the side panels.
3. Align the two bolt holes on each side of the stand with the two t hreaded holes on each sideoftheoven.SeeFigure1.
4. Insert a bolt from the bottom up through each of the two holes and tighten securely.
5. Reinstall the side panels.
ASSEMBLY TO OPTIONAL PROOFER
1. Center the oven frame on top of the proofer so that the oven overhangs at both the front and back. See Figure 1.
2. Remove the four screws on the back of the proofer. Remove the left and right side panels.
3. Align the two bolt holes on each side of the proofer with the two threaded holes on each sideoftheoven.SeeFigure1.
4. Insert a bolt from the bottom up through each of the two holes and tighten securely.
5. Reinstall the side panels.
SIDE VIEW WITH OPTIONAL PROOFERSIDE VIEW WITH STAND
Figure 1
4
Installation
Ventilation
On gas models the installation of a proper ventila­tion system cannot be over emphasized. This sys­tem removes unwanted vapors and products of combustion from the operating area.
U.S. and Canadian installations
Refer to your local ventilation codes. In the ab­sence of local codes, refer to the National ventila­tion code titled, “Standard for the Installation of
Equipment for the Removal of Smoke and Grease Laden Vapors from Commercial Cooking Equip­ment”, NFPA-96-Latest Edition.
General export installations
Installation must conform with Local and National installation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the proper installation and/or operation of your Blodgett oven, please contact your local distributor. If you do not have a local dis­tributor, please call the Blodgett Oven Company at 0011-802-860-3700.
WARNING:
Failure to properly vent the oven can be hazardous to the health of the operator and may result in operational problems, unsatisfactory baking and possible dam­age to the equipment.
Damage sustained as a direct result of im­proper ventilation will not be covered by the manufacturer’s warranty.
CANOPY TYPE EXHAUST HOOD
A mechanically driven, canopy type exhaust hood is the preferred method of ventilation. The exhaust fan should have an interlock switch with the oven to prevent the oven from operating when the ex­haust fan is not running.
The hood should be sized to completely cover the equipment plus a n overhang of at least 6” (15 cm) on all sides not adjacent to a wall. The distance from the floor to the lower edge of the hood should not exceed 7’ (2.1m).
The total makeup and exhaust air requirements for hood capacity should be approximately 35 CFM
3
(.99 m
/min).
5
Installation
Utility Connections --- Standards and Codes
THE INSTALLATION INSTRUCTIONS CONTAINED HEREIN ARE FOR THE USE OF QUALIFIED IN­STALLATION AND SERVICE PERSONNEL ONLY. INSTAL LATION OR SERVICE BY OTHER THAN QU­ALIFIED PERSONNEL MAY RESULT IN DAMAGE TO THE OVEN AND/OR INJURY TO THE OPERA­TOR.
Qualified installation personnel are individuals, a firm, a corporation, or a company which either in person or through a representative are engaged in, and responsible for:
D the installation or replacement of gas piping
and the connection, installation, repair or serv­icing of equipment.
D the installation of electrical wiring from the elec-
tric meter, main control box or service outlet to the electric appliance.
Qualified installation personnel must be experi­enced in such work, familiar with all precautions required, and have complied with all requirements of state or local authorities having jurisdiction.
U.S. and Canadian installations
Installation must conform with local codes, or in the absence of local codes, with the ANSI Z83.11a- CSA 1.8a-2004 Gas Food Service Equipment as applicable.
Installation must conform with local codes, or in the absence of local codes, with the National Elec-
trical Code, ANSI/NFPA 70 ---Latest Edition and/or CSA 22.1 as applicable.
General export installations
Installation must conform with Local and National installation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the proper installation and/or operation of your Blodgett oven, please contact your local distributor. If you do not have a local dis­tributor, please call the Blodgett Oven Company at 0011-802-860-3700.
6
Installation
p
p
g
Gas Connection
GAS PIPING
A properly sized gas supply system is essential for maximum oven performance. Piping should be sized to provide a supply of gas sufficient to meet the maximum demand of all appliances on the line without loss of pressure at the equipment.
Example:
NOTE: BTU values in the following example are
for natural gas.
YoupurchaseaXR8-Grackoventoaddtoyourex­isting cook line.
1. Add the BTU rating of your current appliances. Pitco Fryer 120,000 BTU
6 Burner Range 60,000 BTU Deck Oven 50,000 BTU Total 230,000 BTU
2. Add the BTU rating of the new oven to the to­tal.
Previous Total 230,000 BTU XR8-G 110,000 BTU New Total 340,000 BTU
3. Measure the distance from the gas meter t o the cook line. This is the pipe length. Let’s say thepipelengthis30’(9.1m)andthepipesize is 1” (2.54 cm).
4. Use the appropriate table to determine the to­tal capacity of your current gas piping.
The total capacity for this example is 375,000 BTU. Since the total required gas pressure, 340,000 BTU is less than 375,000 BTU, the current gas piping will not have to be in­creased.
NOTE: The BTU capacities given in the tables are
for straight pipe lengths only. Any elbows or other fittings will decrease pipe capaci­ties. Contact your local gas supplier if you have any questions.
Maximum Capacity of Iron Pipe in Cubic Feet
of Natural Gas Per Hour
(Pressure drop of 0.5 Inch W.C.)
Pipe
Length (ft)
10 360 680 1400 2100 3950
20 250 465 950 1460 2750
30 200 375 770 1180 2200
40 170 320 660 990 1900
50 151 285 580 900 1680
60 138 260 530 810 1520
70 125 240 490 750 1400
80 118 220 460 690 1300
90 110 205 430 650 1220
100 103 195 400 620 1150
From the National Fuel Gas Code Part 10 Table 10-2
Maximum Capacity of Pipe in Thousands of
BTU/hr of Undiluted L.P. Gas at 11” W.C.
(Pressure drop of 0.5 Inch W.C.)
Pipe Length
(ft)
10 608 1146 3525
20 418 788 2423
30 336 632 1946
40 287 541 1665
50 255 480 1476
60 231 435 1337
70 215 404 1241
80 198 372 1144
90 187 351 1079
100 175 330 1014
From the National Fuel Gas Code Part 10 Table 10-15
Nominal Size, Inches
3/4” 1” 1-1/4” 1-1/4” 2”
Outside Diameter , Inches
3/4” 1” 1-1/2”
7
Installation
Gas Connection
PRESSURE REGULATION AND TESTING
XR8-G ovens are rated at 110,000 BTU/Hr. (32 kW) (116 MJ/hr). Each oven has been adjusted at the factory to operate with the type of gas specified on the rating plate.
Inlet Pressure
Natural Propane
Min Max Min Max
W.C. 6.0 14.0 11.0 14.0
kPa 1.2 3.5 2.7 3.5
Manifold Pressure
Natural Propane
W.C. 3.5 10.0
kPa .87 2.5
D Inlet Pressure --- the pressure of the gas before
it reaches the oven.
D Manifold Pressure --- the pressure of the gas
as it enters the main burner(s).
D Min --- the minimum pressure recommended to
operate the oven.
D Max --- the maximum pressure at which the
manufacturer warrants the oven’s operation.
Each oven is supplied with a regulator to maintain the proper gas pressure. The regulator is essen-
tial to the proper operation of the oven and should not be removed. It is preset to provide the
oven with 3.5” W.C. (.87 kPa) for natural gas and
10.0” W.C. (2.5 kPa) for Propane at the manifold.
DO NOT INSTALL AN ADDITIONAL REGULATOR WHERE THE OVEN CONNECTS TO THE GAS SUPPL Y UNLESS THE INLET PRESSURE IS ABOVE MAXIMUM.
Prior to connecting the oven, gas lines should be thoroughly purged of all metal filings, shavings, pipe dope, a nd other debris. After connection, the oven should be checked for correct gas pressure.
The oven and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressuresinexcessof1/2psig(3.45kPa).
The oven must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas piping system at test pressures equal or less than 1/2 psig (3.45kPa).
Gas Connection
2.78” (71 mm)
SIDE VIEW WITH STAND
Figure 2
8
53.62 (1362) Gas Connection
37.83 (961mm)
Gas Connection
SIDE VIEW WITH OPTIONAL PROOFER
Loading...
+ 27 hidden pages