WARNING: IMPROPER INSTALLA TION, ADJUSTMENT, AL TERATION, SERVICE OR
MAINTENAN C E CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH.READ THE
INSTALLA TION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING THIS EQUIPMENT
AVERTISS EMENT: UNE INSTALLATION, UN AJUSTEMENT, UNE ALTÉRATI O N , UN
SERVICE OU UN ENTRETIENNON CONFORME AUX NORMES PEUT CAUSERDES
DOMMAGESÀ LA PROPRIÉTE,DES BLESSURES OU LA MORT. LISEZ ATTENTIV EMENT LES DIRECTI V ESD’INSTALLA TI ON, D’OPÉRA TI ON ET D’ENTRETIEN AV A N T
DE FAIRE L’INS TALLATION OU L’ENTRETIEN DE CET ÉQUIPEMENT.
INSTRUCTIONS (PAGE 12) TO BE FOLLOWED IN THE EVENT THE USER
SMELLS GAS MUST BE POSTED IN A PROMINENT LOCATION. THIS INFORMATION MAY BE OBTAINED BY CONTACTING YOUR LOCAL GAS SUPPLIER.
LESINSTRUCTIONS (PAGE12)À RESPECTERAUCASOÙ L’UTILISATEUR PERÇOIT UNE ODEUR DE GAZ DOIVENT ÊTRE AFFICHÉES DANS UN ENDROIT BIEN
VISIBLE. VOUS POUVEZ VOUS LES PROCURER AUPRÈS DE VOTRE FOURNISSEUR DE GAZ LOCAL.
FORYOURSAFETY
Do not store or use gasoline or other flammable vapors or liquids in the vicinity
of this or any other appliance.
AVERTISSEMENT
Ne pas entreposer ni utiliser de l’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appariel, ni de tout autre appareil.
The information contained in this manual is important for the proper installation,
use, and maintenance of this oven. Adherence to these procedures and instructions will result in satisfactory baking results and long, trouble free service.
Please read this manual carefully and retain it for future reference.
Les informatio n s données dans le présent manuel sont importantes pour installer,
utiliser et entret enir correctement ce four. Le respect de ces instructio n s et procédures permettra d’obtenir de bonsrésultats de cuisson et une longue durée de service sans problèmes. Veuillez lire le présent manuel et le conserver pour pouvoir
vous y reporter à l’avenir.
Errors: Descriptive, typographic or pictorial errors are subject to correction. Specifica-
tions are subject to change without notice.
Erreurs:Les erreurs de description, de typographie ou d’illustration font l’objet de
corrections. Les caractéristiques sont sujettes à modifications sans préavis.
THE REPUTATION YOU CAN COUNT ON
UNE RÉPUTATION SUR LAQUELLE VOUS POUVEZ COMPTER
For over a century and a half, The Blodgett Oven Company has been building
ovens and nothing but ovens. We’ve set the industry’s quality standard for all
kinds of ovens for every foodservice operation regardless of size, application
or budget. In fact, no one offers more models, sizes, and oven applications
than Blodgett; gas and electric, full-size, half-size, countertop and deck, convection, Cook’n Hold, Combi-Ovens and the industry’s highest quality Pizza
Oven line. For more information on the full line of Blodgett ovens contact your
Blodgett representative.
Cela fait maintenant dessus un siècle et demi que Blodgett se spécialise dans
la fabrication de fours. Nous avons établi les normes de qualité qui s’appliquent dans l’industrie à tous les types de fours utilisés dans les services alimentaires, quel qu’en soit la taille,l’exploitation ou le budget. En fait, ni n’offre
plus de modèles, de tailles et d’applications de fours que Blodgett. À gaz et
électriques. De tailles différentes, sur plan de travail et superposables. Qu’il
s’agisse de fours à convection, des modèles Cook’n Hold et Combi-Oven, ou
de la gamme de fours à pizzas de la plus haute qualité offerte sur le marché.
Pour de plus amples informations sur la gamme complète de fours Blodgett,
veuillez contacter votre représentant Blodgett.
Your Service Agency’s Address:
Adressedevotreagencedeservice:
Model/Modèle:
Serial Number/Numéro de série:
Your oven was installed by/
Installateur de votre four:
Your oven’s installation was checked by/
Contrôleur de l’installation de votre four:
Table of Contents/Table des Matières
Introduction
Oven Description and Specifications2....
Installation
Delivery and Location3.................
Oven Assembly4......................
Assembly to Stand4..................
Assembly to Optional Proofer4.........
Ventilation5...........................
Utility Connections ---
Standards and Codes6.................
Gas Connection7......................
Plumbing and Electrical Connections10...
Initial Startup11.........................
Operation
Safety Information12....................
Standard Control13.....................
General Guidelines for
Operating Personnel15..................
Introduction
Description et Spécifications du Four18....
Installation
Livraison et Implantation19...............
Montage du Four20.....................
Assembly to stand20..................
Assembly to optional proofer20.........
Ventilation21...........................
Branchements de Service ---
Normes et Codes22.....................
Branchement de Gaz23.................
Raccordement Électrique et Plomberie26..
Mise en Marche Initiale27................
Utilisation
Informations de Sécurité28...............
Standard Control29.....................
Consignes Générales à l’Intention
des Utilasateurs31......................
Maintenance
Cleaning and Preventative Maintenance16.
Troubleshooting Guide17................
Entretien
Nettoyage et Entretien Préventif32........
GuidedeDétectiondesPannes33........
Introduction
Oven Description and Specifications
The Blodgett Mini-Rack oven features a continuously rotating eight pan rack and unique airflow
system that moves large amounts of air at low velocity to ensure a consistently even bake. The
Blodgett rack slide sytem allows the operator to
quickly adjust slide spacing from 1 to 4 inches in
GAS SPECIFICATIONS -- XR8-G/AA
Natural GasPropane Gas
US UnitsSI UnitsUS UnitsSI Units
Heating Value1000 BTU/cu. ft.37.3 MJ/m
Specific Gravity (air=1.0)0.630.631.531.53
Gas Manifold Pressure3.5” W.C..87 kPa10” W.C.2.5 kPa
Oven Input110,000 BTU/hr32 kW
Main Burner Orifice Size:
Six burners are
Two burners are
.07” dia.
.061” dia.
PLUMBING SPECIFICATIONS -- XR8-G/AA
any configuration. In addition, the Mini-Rack oven
is capable of producing large volumes of steam for
bagels or similar products.
All Blodgett ovens are shipped in containers to
prevent damage. Upon delivery of your new oven:
D Inspectthe shipping container for external dam-
age. Any evidence of damage should be noted
on the delivery receipt which must be signed by
the driver.
D Uncrate the oven and check for internal dam-
age. Carriers will accept claims for concealed
damage if notified within fifteen days of delivery
and the shipping container is retained for inspection.
The Blodgett Oven Company cannot assume
responsibility for loss or damage suffered in
transit. The carrier assumed full responsibility
for delivery in good order when the shipment
was accepted. We are, however, prepared to
assist you if filing a claim is necessary.
OVEN LOCATION
The well planned and proper placement of your
oven will result in long term operator convenience
and satisfactory performance.
The following clearances must be maintained be tween the oven and any combustible or non-combustible construction.
D Oven body right side --- 0” (0 cm)
D Oven body left side --- 0” (0 cm)
D Oven body back --- 0” (0 cm)
D Oven top --- 12” (30.5 cm)
The following clearances must be available for servicing.
D Oven body sides --- 12” (30 cm)
D Oven body back --- 12” (30 cm)
D Oven top --- 12” (30.5 cm)
NOTE: On gas models, routine servicing can usu -
ally be accomplished within the limited
movement provided by the gas hose restraint. If the oven needs to be moved fur ther from the wall, the gas must first be
turned off and disconnected from the oven
before removing the restraint. Reconnect
the restraint after the oven has been returned to its normal position.
It is essential that an adequate air supply to the
oven be maintained to provide a sufficient flow of
combustion and ventilation air.
D Place the oven in an area that is free of drafts.
D Keep the oven area free and clear of a ll combus-
tibles such as paper, cardboard, and flammable
liquids and solvents.
D Do not place the oven on a curb base or sea l to
a wall. This will restrict the flow of air and prevent
proper ventilation. Tripping of the blower motor’s thermal overload device is caused by an
excessive ambient temperature on the right
side of the oven. This condition must be corrected to prevent permanent damage to the
oven.
D The location must provide adequate clearance for
the air opening into the burners.
Before making any utility connections to this oven,
check the rating plate to be sure the oven specifications are compatible with the gas and electrical
services supplied for the oven.
1. The rating plate is located behind the control
panel.
2. Remove the two screws on the rightside of the
control panel.
3. Pull the control panel toward the right side of
the oven.
4. Pull the control panel away from the oven and
rotate out.
5. Reverse steps 2-4 to close the control panel.
3
Installation
Oven Assembly
ASSEMBLY TO STAND
1. Center the oven frame on top of the stand so
that the oven overhangs at both the front and
back. See Figure 1.
2. Remove the three screws at the top of the left
and right side panels of the oven. Remove the
side panels.
3. Align the two bolt holes on each side of the
stand with the two t hreaded holes on each
sideoftheoven.SeeFigure1.
4. Insert a bolt from the bottom up through each
of the two holes and tighten securely.
5. Reinstall the side panels.
ASSEMBLY TO OPTIONAL PROOFER
1. Center the oven frame on top of the proofer so
that the oven overhangs at both the front and
back. See Figure 1.
2. Remove the four screws on the back of the
proofer. Remove the left and right side panels.
3. Align the two bolt holes on each side of the
proofer with the two threaded holes on each
sideoftheoven.SeeFigure1.
4. Insert a bolt from the bottom up through each
of the two holes and tighten securely.
5. Reinstall the side panels.
SIDE VIEW WITH OPTIONAL PROOFERSIDE VIEW WITH STAND
Figure 1
4
Installation
Ventilation
On gas models the installation of a proper ventilation system cannot be over emphasized. This system removes unwanted vapors and products of
combustion from the operating area.
U.S. and Canadian installations
Refer to your local ventilation codes. In the absence of local codes, refer to the National ventilation code titled, “Standard for the Installation of
Equipment for the Removal of Smoke and Grease
Laden Vapors from Commercial Cooking Equipment”, NFPA-96-Latest Edition.
General export installations
Installation must conform with Local and National
installation standards. Local installation codes
and/or requirements may vary. If you have any
questions regarding the proper installation and/or
operation of your Blodgett oven, please contact
your local distributor. If you do not have a local distributor, please call the Blodgett Oven Company at
0011-802-860-3700.
WARNING:
Failure to properly vent the oven can be
hazardous to the health of the operator
and may result in operational problems,
unsatisfactory baking and possible damage to the equipment.
Damage sustained as a direct result of improper ventilation will not be covered by
the manufacturer’s warranty.
CANOPY TYPE EXHAUST HOOD
A mechanically driven, canopy type exhaust hood
is the preferred method of ventilation. The exhaust
fan should have an interlock switch with the oven
to prevent the oven from operating when the exhaust fan is not running.
The hood should be sized to completely cover the
equipment plus a n overhang of at least 6” (15 cm)
on all sides not adjacent to a wall. The distance
from the floor to the lower edge of the hood should
not exceed 7’ (2.1m).
The total makeup and exhaust air requirements for
hood capacity should be approximately 35 CFM
3
(.99 m
/min).
5
Installation
Utility Connections --- Standards and Codes
THE INSTALLATION INSTRUCTIONS CONTAINED
HEREIN ARE FOR THE USE OF QUALIFIED INSTALLATION AND SERVICE PERSONNEL ONLY.
INSTAL LATION OR SERVICE BY OTHER THAN QUALIFIED PERSONNEL MAY RESULT IN DAMAGE
TO THE OVEN AND/OR INJURY TO THE OPERATOR.
Qualified installation personnel are individuals, a
firm, a corporation, or a company which either in
person or through a representative are engaged
in, and responsible for:
D the installation or replacement of gas piping
and the connection, installation, repair or servicing of equipment.
D the installation of electrical wiring from the elec-
tric meter, main control box or service outlet to
the electric appliance.
Qualified installation personnel must be experienced in such work, familiar with all precautions
required, and have complied with all requirements
of state or local authorities having jurisdiction.
U.S. and Canadian installations
Installation must conform with local codes, or in
the absence of local codes, with the ANSI Z83.11a-CSA 1.8a-2004 Gas Food Service Equipment as
applicable.
Installation must conform with local codes, or in
the absence of local codes, with the National Elec-
Installation must conform with Local and National
installation standards. Local installation codes
and/or requirements may vary. If you have any
questions regarding the proper installation and/or
operation of your Blodgett oven, please contact
your local distributor. If you do not have a local distributor, please call the Blodgett Oven Company at
0011-802-860-3700.
6
Installation
p
p
g
Gas Connection
GAS PIPING
A properly sized gas supply system is essential for
maximum oven performance. Piping should be
sized to provide a supply of gas sufficient to meet
the maximum demand of all appliances on the line
without loss of pressure at the equipment.
2. Add the BTU rating of the new oven to the total.
Previous Total230,000 BTU
XR8-G110,000 BTU
New Total340,000 BTU
3. Measure the distance from the gas meter t o
the cook line. This is the pipe length. Let’s say
thepipelengthis30’(9.1m)andthepipesize
is 1” (2.54 cm).
4. Use the appropriate table to determine the total capacity of your current gas piping.
The total capacity for this example is 375,000
BTU. Since the total required gas pressure,
340,000 BTU is less than 375,000 BTU, the
current gas piping will not have to be increased.
NOTE: The BTU capacities given in the tables are
for straight pipe lengths only. Any elbows
or other fittings will decrease pipe capacities. Contact your local gas supplier if you
have any questions.
Maximum Capacity of Iron Pipe in Cubic Feet
of Natural Gas Per Hour
(Pressure drop of 0.5 Inch W.C.)
Pipe
Length (ft)
1036068014002100 3950
202504659501460 2750
302003757701180 2200
401703206609901900
501512855809001680
601382605308101520
701252404907501400
801182204606901300
901102054306501220
1001031954006201150
From the National Fuel Gas Code Part 10 Table 10-2
Maximum Capacity of Pipe in Thousands of
BTU/hr of Undiluted L.P. Gas at 11” W.C.
(Pressure drop of 0.5 Inch W.C.)
Pipe Length
(ft)
1060811463525
204187882423
303366321946
402875411665
502554801476
602314351337
702154041241
801983721144
901873511079
1001753301014
From the National Fuel Gas Code Part 10 Table 10-15
Nominal Size, Inches
3/4”1”1-1/4” 1-1/4”2”
Outside Diameter , Inches
3/4”1”1-1/2”
7
Installation
Gas Connection
PRESSURE REGULATION AND TESTING
XR8-G ovens are rated at 110,000 BTU/Hr. (32 kW)
(116 MJ/hr). Each oven has been adjusted at the
factory to operate with the type of gas specified on
the rating plate.
Inlet Pressure
NaturalPropane
MinMaxMinMax
W.C.6.014.011.014.0
kPa1.23.52.73.5
Manifold Pressure
NaturalPropane
W.C.3.510.0
kPa.872.5
D Inlet Pressure --- the pressure of the gas before
it reaches the oven.
D Manifold Pressure --- the pressure of the gas
as it enters the main burner(s).
D Min --- the minimum pressure recommended to
operate the oven.
D Max --- the maximum pressure at which the
manufacturer warrants the oven’s operation.
Each oven is supplied with a regulator to maintain
the proper gas pressure. The regulator is essen-
tial to the proper operation of the oven and
should not be removed. It is preset to provide the
oven with 3.5” W.C. (.87 kPa) for natural gas and
10.0” W.C. (2.5 kPa) for Propane at the manifold.
DO NOT INSTALL AN ADDITIONAL REGULATOR
WHERE THE OVEN CONNECTS TO THE GAS
SUPPL Y UNLESS THE INLET PRESSURE IS
ABOVE MAXIMUM.
Prior to connecting the oven, gas lines should be
thoroughly purged of all metal filings, shavings,
pipe dope, a nd other debris. After connection, the
oven should be checked for correct gas pressure.
The oven and its individual shutoff valve must be
disconnected from the gas supply piping system
during any pressure testing of that system at test
pressuresinexcessof1/2psig(3.45kPa).
The oven must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the
gas piping system at test pressures equal or less
than 1/2 psig (3.45kPa).
Gas Connection
2.78” (71 mm)
SIDE VIEW WITH STAND
Figure 2
8
53.62 (1362)
Gas Connection
37.83 (961mm)
Gas Connection
SIDE VIEW WITH OPTIONAL PROOFER
Loading...
+ 27 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.