Blodgett XCEL-50EC Service Manual

Page 1
Service Manual
Model - XL50EC
Grilled Chicken Oven with
Semi-automatic Cleaning System
Blodgett Oven Co. ~ 44 Lakeside Ave., Burlington, VT 05401 ~ 800-331-5842 ~ www.blodgett.com ~ 12/1/08
Page 2
Page 3
44 Lakeside Avenue, Burlington Vermont 05401 U.S.A.
Telephone: 1-(800)331-5842 (802)860-3700 D Fax:(802)652-2814
XCEL-50EC KFC OVEN STARTUP/ACTIVATION CHECKLIST
Return form to BLODGETT when job is complete. Submit one form with each unit installed.
SERIAL NO.
STORE ID
ADDRESS
CITY________________________ STATE_______ ZIP
PHONE:(______)
ELECTRIC: V VOLTAGE_____________ PHASE
MODEL_______________DATE OF INSTALLATION
SERVICE AGENCY
ADDRESS
CITY________________________ STATE_______ ZIP
PHONE:(______)______________ MECHANIC
The rating plate is located on the back of the oven.
OPERATIONAL START-UP/ACTIVATION PROCEDURE
Information can be found in the Startup Guide or by contacting the factory. Write in N/A if not applicable.
1. Flush Water inlet hose for 30 seconds to remove all debris in the water line before attaching the water hose to oven. Verify water is cold. Yes No
2. Is the oven level? If no, level the unit. Yes No
3. Drain pipe and drain actuator are installed? Yes No
4. Does drain hose reach open drain? Cut to length as needed. Attach the 90_ pvc fitting to the end of the hose.
5. Is the cleaning solution tray installed? Be sure there are no kinks in the chemical line.
6. COMPONENT FUNCTION TESTS: In “Diag Input” mode, check the operation of the following;
_____ 1. Door Strike Switch _____ 2. Door Proximity Switch
7. COMPONENT FUNCTION TESTS: In “Diag Output” mode, check the operation of the following;
_____ 1. Heat On (Light on the S S Relay) _____ 8. Quench Solenoid
Yes No
Yes No
_____ 2. Fan High _____ 9. Chem Pump
_____ 3. Fan Low _____ 10. Recirc Pump
_____ 4. Fan Forward _____ 11. Door Lock
_____ 5. Fan Reverse _____ 12. Contactor
_____ 6. Cooling Fan _____ 13. Water Solenoid
_____ 7. Drain Valve (look down drain) _____ 14. Recirc Valve
8. Set the water pressure to 20-PSI flowing. Test 2 quarts in 50 seconds. Yes No
9. Verify there are no water leaks from the connector to the cavity. Yes No
10. Verify blower wheel wing screw is tight. Yes No
11. Verify all metal edges are deburred. Yes No
12. Verify the baffle and racks a re installed properly. Yes No
13. Verify incoming voltage matches Data Tag of oven. Yes No
14. Applied voltage between L1 to L2 ______ L2 to L3______ L1 to L3 ______
15. Amp draw at terminal block L1_____ L2 _____ L3 _____
16. Turn oven on. Allow heat to cycle 3 times. Shut oven off. Yes No
17. Apply your company sticker on “Door Lock” cover. Y es No
18. Remove all protective vinyl from exterior sheet metal. Yes No
Fax completed form to Blodgett at 802-652-2814.
This appliancemay be equipped with proprietaryfeatures and/or components which are for the exclusiveuseofthecustomerindicated above. Further, there may be procedures and/or methods being utilized in preparing this customer’s productwhichmay be proprietary. I hereby certify that this information will be held in confidence and not disclosed to any third party for whom it is not intended.
I hereby certify that the above indicated Blodgett XCEL-50EC KFC oven has been installed, a ctivated and is in good working order.
Service Agent’s Signature
FORM/Serv.27
(White Copy To Blodgett Warranty Department, Yellow Copy To Customer, Pink Copy To Service Agency)
Store Manager’s Signature
P/N 52246 Rev A
Page 4
FAST ~ VVC for XL-50EC Oven
Second Level Programming
(The oven needs to be in the “ON” position)
Press and hold the (P) Button
for 3 seconds
Press the (P) Button Enter Service Code “2222”
Press the (P) Button Scroll to “Diag Input”
Strike Switch Press button 1, open closed door
Hinge Switch (Proximity) Press button 2, open closed door
Press the (P) Button Scroll to “Diag Output”
Press the (P) Button
Press and hold # button to test Component Function Test:
1 S/S Heat Relay 2Fan High
Scroll to “Programming”
3 Fan Low 4 Fan Forward (CCW) 5 Fan Reverse (CW) 6 Cooling Fan (Blows in) 7 Drain Valve Actuator (N.C.) 8 Quench Solenoid
9 Chemical Pump 10 Recirc Pump 11 Door Lock Motor 12 Mechanical Contactor (N.C.) 13 Water Fill Solenoid 14 Recirc Solenoid
Press the (P) Button
Scroll to exit
Page 5
FAST ~ VVC for XL-50EC Oven
Second Level programming
Press and hold the
(P) Button for 3 seconds
Press the (P) Button Code 2222
Press the (P) Button Scroll to “Clean Cycle”
Press the (P) Button
Corresponding Name Press to scroll through times
Pre-Rinse Time 3:00
Fill Time 1:45
Chemical Time 3:45
Wash Time 45:00 Rinse Time 5:00
Pump Fill Time 2:30
Purge Time 2:00
Scroll to programming
Final Rinse Time 10:00
Flush Time 2:00
Drain Time 3:00
Set Temp 180F
Fan Speed Very High
Fan Reverse Time 3:00
Soil Shield NO
Full Bottle Time 17:12
To exit programming Press to “EXIT”
Press the (P) Button
NOTE: Fill times are based on 20 PSI inlet flow pressure
Page 6
J6-Pin #1
J2-
Pin #1
XL-50EC Relay Board – Rear View
Call outs of “J” connectors and #1 pin location
J3-Pin #1
J20-Pin #1
J14-Pin #1
J1-Pin #1
J18-Pin #1
J7-Pin #1
J19-Pin #1
J11-Pin #1
J41-Pin #1
Page 7
Voltage
Voltage
XL-50EC - Trouble shooting test points
Test Points on Relay Board
Test Points on Relay Board
~ Using the control diagnostic outputs ~
Key # Output Components
1 6 7 8
9 13 12
10
14
S/S Heat Relay
Cooling Fan
Drain Actuator
Quench Solenoid
Chemical Pump
Fill (Spritzer) Solenoid
*** Mech. Contactor
Recirc Pump
Recirc Solenoid
Connector J18-Pin #5(Empty) Connector J20-Pin #2-OR Connector J18-Pin #5(Empty) Connector J3-Pin#11-GY Connector J18-Pin #5(Empty) Connector J18-Pin #7-OR Connector J18-Pin #5(Empty) Connector J2-Pin #6-OR Connector J18-Pin #5(Empty) Connector J2-Pin #8-V Connector J18-Pin #5(Empty) Connector J18- Pin#3-BL Connector J18-Pin #5(Empty) Connector J6-Pin #5-OR
Terminal #12, 7+8-WH on rear
Terminal #12, 7+8-WH on rear
Black lead Red Lead
24 volt transformer
24 volt transformer
Connector J6- Pin #8-V
Connector J3-Pin #6-Y
*** NOTE: Component is normally energized, de-energizes during testing
AC + DC
24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC
24 VAC
Key # Motor Inverter Drive
Fan High Speed (75Hz)
2
Fan Low Speed (60Hz)
3
4
5
Fan Forward (45Hz)
Fan Reverse (45Hz) Connector
Connector J11-Pin #1-BK
Connector J11-Pin #1-BK
Connector
Black lead Red Lead
Connector J2-Pin#9-GY
Connector J2-Pin#10-GY
Connector J2-Pin#9-GY
Connector J2-Pin#10-GY
Connector J2-Pin#9-GY
J11-Pin #1-BK
J11-Pin #1-BK
Connector J2-Pin#10-GY Connector J2-Pin#11-GY Connector J2-Pin#12-GY
Connector J2-Pin#9-GY Connector J2-Pin#10-GY Connector J2-Pin#11-GY Connector J2-Pin#12-GY
AC + DC
23 VDC
0.0 VDC
0.0 VDC 23 VDC 23 VDC 23 VDC
0.0 VDC 23 VDC 23 VDC 23 VDC 23 VDC
0.0 VDC
NOTE: Logic for motor control connects return circuit. "0" volts means circuit completed
Page 8
Control Transformer
Control Transformer
Convection Motor Windings
Connection Motor Windings
Connection Motor Windings
Component Resistance Readings
Part Name Ohms Part Name Ohms
24VDC Power Supply, Across +V & -V
(Unwired DC Voltage)
24VDC Power Supply, Across L & N
(Unwired Line Voltage)
Chemical Pump Motor 23.9 Cooling Fan 3.7
Component Transformer- Jumper
Removed Primary contacts 1 & 2
Component Transformer- Jumper
Removed Primary contacts 6 & 5
Component Transformer- with Jumper
Primary contacts 6 & 1
Component Transformer with Jumper
Secondary contacts 7 & 12
Element, 208V (Single element) 10.8 Liquid Detection Sensor 20
326
0.6
6.4 Door Lock Motor 6
5.5 Hitachi (Brown to Blue) 2.5
11.4 Hitachi (Brown to Black) 27.65
0.3 Hitachi (Blue to Black) 27.65
(Primary)
(Secondary)
62.2
1.2
Element, 240V (Single element) 14.5 Mechanical Contactor Coil 73.4
Quench Solenoid Valve 178
Re-Circ Solenoid Valve 2.3
Recirculation Pump 1.5
Water Solenoid Valve 178 Solid State Heat Relay (SSR) 5.12
Note: Readings may vary some based on meter capability and accuracy
Blue to Black
Brown to Black
Brown to Blue
6.2
6.2
6.2
Page 9
FAST ~ VVC for XL-50EC Oven
Error State Controller Message Error Cause
The controller cannot detect the input
Fan Error Detection "FAN ERROR"
Fan Error Detection
in clean/delime
cycles
Clean/Delime Error
“WARNING-DO NOT OPEN
DOOR” “DO NOT USE OVEN”
"FAN ERROR"
“CALL FOR SERVICE”
signal from the "at speed" relay for
15sec, indicating the fan is in fact ON. VFD has sensed fan issues. Most
likely the drain has malfunctioned and cavity is full of water and chemical.
If a second fan errors occur during the clean/delime cycle.
Strike Switch Error
SSR Heat Sink
Error
Fan Drive Error
Detection
High Limit Error "HIGH LIMIT ERROR"
Door Lock Error
In clean/Delime
cycles
High Limit Temp
Error-Cavity
High Temp Error-
Cavity
Inverter Drive
Probe Error
Cavity Probe Error
Cook Heat Fail
Detection
"HEAT SINK ERROR"
"FAN DRIVE ERROR"
"ERROR-DOOR NOT LOCKED"
In Idle: "HI LIMIT TEMP"
In Cook: "FAIL-HI LIMIT TEMP"
In Cook: "FAIL-HI TEMP"
"BAD DRIVE PROBE­CALL FOR SERVICE"
In Idle: "PROBE OPEN/SHORT"
In Cook: "FAIL-PROBE
"ERROR“
“STRIKE SWITCH"
In Idle: "HI TEMP"
OPEN/SHORT"
"FAIL-COOK HEAT"
If the "Hinge" switch is open, but the "Strike" switch remains closed.
The controller cannot detect the input signal from the SSR thermal switch.
The controller cannot detect the Fan Drive input for 10 seconds.
If the controller sees an input from the
mech contactor for more than 2 sec.
Controller cannot detect the door lock input for 5 seconds while in the CLEAN or DELIME mode. Top micro­switch on door lock not fully engaged or bad.
If the cavity temperature (from the cavity probe) is greater than 565°F.
If the cavity temp (from the cavity probe) is greater than the set temp of the first profile selected +150°F.
If the probe in the heat sink of the VFDrive (Hitachi Drive Probe) opens or shorted.
If the cavity probe is open or shorted.
If the cavity temperature doesn't rise 2°F within 5 min.
Communication
Error
Recovery Detection
NOTE: Faults that occur during clean or delime cycles must be cleared with the “HELP” code, or 4357.
In Idle: "COMM ERROR
CALL FOR SERVICE"
In Cook: "FAIL-COMM ERROR"
"HEAT ERROR
CALL FOR SERVICE"
\\bgtstore\public1\Service\Customers\K F C\Grill Chicken Program\Self-Cleaning Ovens\Round 2 Ovens\Technical Info\Error Codes KFC Oven.doc
If the controller looses communication with the relay board.
If the cavity temp doesn't make it from 150°F to 300°F within 5 mins.
Page 10
BLODGETT XL50EC - KFC - Motor Drive Parameters
PRESS PRESS
FUNC d001 STR to save b005
DISPLAY DISPLAY
keep pushing until A--- once b012
FUNC once A001 FUNC once FUNC once
keep pushing until 4. 0 0
once 02 STR to save b012
STR to save A001
once b022
once A002 FUNC once
FUNC once
keep pushing until 3. 6 0
keep pushing until 01 STR to save b022
STR once A002
once b083
keep pushing until A020 FUNC once
FUNC once
keep pushing until 10.0
push + hold until 45.0 STR to save b083
STR to save A020
keep pushing until C001
once A021 FUNC once
FUNC once
keep pushing until 00
push + hold until 60.0 STR to save C001
STR to save A021
once C002
once A022 FUNC once
FUNC once
keep pushing until 01
push + hold until 75.0 STR once C002
STR to save A022
once C003
once A023 FUNC once
FUNC once
keep pushing until 02
push + hold until 95.0 STR once C003
STR to save A023
once C004
keep pushing until A051 FUNC once
FUNC once
keep pushing until 03
once 01 STR to save C004
STR to save A051
once C005
once A052 FUNC once
FUNC once
keep pushing until 12
push + hold until 40.0 STR to save C005
STR to save A052
keep pushing until C015
twice A054 FUNC once
FUNC once
keep pushing until 01
push + hold until 60 STR once C015
STR to save A054
keep pushing until C022
once A055 FUNC once
FUNC once
keep pushing until 05
push + hold until 5. 0 STR once C022
STR to save A055
push + hold until b01 FUNC
FUNC once
twice 02 STR
STR to save b001
once b002 FUNC
FUNC once
push + hold until 25.0 STR
STR to save b002
keep pushing until b005 FUNC
FUNC once STR to save 0. 0
keep pushing until F002
once
keep pushing until 2. 0 0
once once once
F002 F003
keep pushing until 5. 0 0
once
F003
keep pushing until d001
Programming Complete
0. 0
keep pushing until 01
Page 11
BLODGETT XL50EC - KFC - Motor Drive Parameters
Checking last three stored error codes
FUNC d001
keep pushing until d081
FUNC once FUNC once d081
keep pushing until d082
FUNC once FUNC once d082
keep pushing until d083
FUNC once FUNC once d083
keep pushing until d001
FUNC
Normal operation
Clearing stored error codes
FUNC d001
keep pushing until b---
FUNC
keep pushing until b084
FUNC FUNC
Press "STOP", "FUNC", and keys and continue to hold all 4 for three seconds. Display will show "D000", then "HC", then screen will scroll and stop at "d001"
FUNC 0. 0
STR
once b001
once 00 once b084
to save
Last error code will be displayed
2nd to last error code will be displayed
3rd to last error code will be displayed
0. 0
0. 0
Motor Inverter Error Codes
E_01 Over current event while at constant speed E_02 Over current event during deceleration E_03 Over current event during acceleration E_04 Over current event during other conditions E_05 Overload protection E_07 Over-voltage protection E_08 EEPROM error E_09 Under-voltage error E_11 CPU error E_22 CPU error E_12 External trip E_13 USP E_14 Groung Fault E_15 Input over-voltage E_21 Inverter thermal trip E_35 Thermistor
Page 12
Sequence of Operation for KFC, XL-50EC oven
Mode Switch in the “OFF” position
You will have AC voltage at:
The 50 AMP Fuse Holder
The Line Side of the (K1) Mech. Contactor
Circuit Breaker (CB1) on the front control panel
24 VDC power supply power light on
The large transformer (T2) on the left hand side in the back of the oven
The small transformer (T1) on the left hand side in the front of the oven
The Relay board Input J7-1 & 3 24 VAC Voltage
The Relay board Input J19-2 & 3 24 VAC Voltage
The VFD Computer Control Input 15 pin connector J1-1 & 3 24 VAC
Voltage
Mode Switch pins 1 & 3 Line Voltage
You will have DC voltage at:
Positive Red DC voltage (+24VDC) on the following;
Relay board J-19-1
TB-4 on back panel 9 down from top right RD 24
Proximity Switch
Door Switch (SW1)
SSR Heat Sink
Mode Switch, in on pin 6, out of pin 5 to the relay board J1-8 (closed in
the OFF position)
Door Lock Control Board
Auxiliary contactor mech. (K1 aux.) in A-1 out A-2 to Relay Board J11-3
Negative Black DC voltage (-24VDC RTN)
Relay Board J19-4
Relay Board J11-1
Door Lock Control Board
A-2 Coil of the Mechanical Contactor
The Drain Actuator
With your Meter Leads:
Black on J18-6 and Red on J18-7
You will have Negative -24vdc in the Closed position
You will have Positive +24vdc in the Open position
Page 13
Sequence of Operation for KFC, XL-50EC oven
Mode Switch in the “ON” position
The Relay Board Verifies the Following with DC voltage:
The Mode Switch contacts opens between 5 & 6 DC voltage is
removed from the Relay Board J11-8
The Door Switch (SW1) is closed sending DC voltage to J11-5
The Proximity Switch is closed sending DC voltage to J11-2
With the Door Lock Switch Open there is no DC voltage present from
the Door Lock Control to the Relay Board on J11-7
The SSR Heat-Sink is Closed sending DC voltage to J11-6
Dc voltage supplied out of the RELAY BOARD J6-5 through the CAVITY
HIGH LIMIT (SW4) to the COIL OF THE MECHANICAL CONTACTOR (K1)
The Contacts of the Mechanical Contactor (K1) close and opens the contacts of the Auxiliary contactor mech. (K1 aux.) removing DC voltage from the Relay Board J11-3
The contacts 1 & 2 and 3 & 4 close on the Mode Switch and send AC voltage to L-1 and L-3 of the Hitachi Motor Inverter Drive.
The Relay Board sends DC voltage out J-2 pins 9 & 10 to the Hitachi
Inverter pins 3 & 4
The Hitachi Inverter speeds up to 75 Hertz
The Hitachi Inverter Verifies DC voltage from pins 11 & L back to the
Relay Board on J11- 4 & 1 Showing the motor is running
The Relay Board sends DC voltage out of J20-2 & 3 to the Control Circuit of the SSR powering the Elements
The controller displays “Preheat” and starts to heat up to 450 degrees
When the oven reach’s a temp of 450 degrees the display will count
down from 30 minutes to heat soak the cavity.
When the 30 minute heat soak counts down the display will read “Load”
Set Program:
The Relay Board sends DC voltage from J2- 9 & 10 to the Hitachi Inverter 3 & 4 and the motors speeds up to 95 Hertz
The motor will reverse directions every 7 minutes by switching DC voltage from the Relay Board J2-11 To Pin 1 on the Hitachi for forward and J2-12 to pin 2 on the Hitachi for reverse
Page 14
Sequence of Operation for KFC, XL-50EC oven
Clean Cycle
Steam Cycle
+24vdc is powered out of J18-3 through the TB4-1 on the backpack
to the water Spritzer solenoid
The water will cycle 1 second ON every 20 seconds from 450 deg to
300 deg
Then the water will cycle 2 seconds ON every 20 seconds from 300
deg to 200 deg
Prerinse 3:00
Drain Opens
+24vdc is powered out of J18-3 through the TB4-1 on the backpack
to the water Spritzer solenoid
+24vdc is powered out of J2-6 through the TB4-2 on the backpack to
the quench solenoid
+24AC is powered out of J3-6 through the TB5-3 on the backpack to
the re-circulation solenoid
Fill Time 1:45
Drain Closed
+24vdc is powered out of J18-3 through the TB4-1 on the backpack
to the water Spritzer solenoid
Chemical Time 3:45
Drain Closed
+24vdc is powered out of J2-8 through the TB5-5 on the backpack to
the chemical pump
Wash Time 45:00
Drain Closed
+24AC is powered out of J6-8 through the TB5-1 on the backpack to
the re-circulation pump
+24AC is powered out of J3-6 through the TB5-3 on the backpack to
the re-circulation solenoid
Page 15
Sequence of Operation for KFC, XL-50EC oven
Rinse Time 5:00
Drain Open
+24vdc is powered out of J18-3 through the TB4-1 on the backpack
to the water Spritzer solenoid
+24vdc is powered out of J2-6 through the TB4-2 on the backpack to
the quench solenoid
+24AC is powered out of J3-6 through the TB5-3 on the backpack to
the re-circulation solenoid
Pump Fill Time 2:30
Drain Closed
+24vdc is powered out of J18-3 through the TB4-1 on the backpack
to the water Spritzer solenoid
+24vdc is powered out of J2-6 through the TB4-2 on the backpack to
the quench solenoid
+24AC is powered out of J3-6 through the TB5-3 on the backpack to
the re-circulation solenoid
Purge Time 2:00
Drain Closed
+24AC is powered out of J6-8 through the TB5-1 on the backpack to
the re-circulation pump
+24AC is powered out of J3-6 through the TB5-3 on the backpack to
the re-circulation solenoid
Final Rinse 10:00
Drain Open
+24vdc is powered out of J18-3 through the TB4-1 on the backpack
to the water Spritzer solenoid
+24vdc is powered out of J2-6 through the TB4-2 on the backpack to
the quench solenoid
+24AC is powered out of J3-6 through the TB5-3 on the backpack to
the re-circulation solenoid
Page 16
Sequence of Operation for KFC, XL-50EC oven
Flush Time 2:00
Drain Open
+24vdc is powered out of J2-6 through the TB4-2 on the backpack to
the quench solenoid
+24AC is powered out of J3-6 through the TB5-3 on the backpack to
the re-circulation solenoid
Final Drain Time 3:00
Drain Open
+24vdc is powered out of J2-6 through the TB4-2 on the backpack to
the quench solenoid
+24AC is powered out of J3-6 through the TB5-3 on the backpack to
the re-circulation solenoid
Page 17
FAST ~ VVC for XL-50EC Oven
Clean Cycle Programming
Press the clean Button “Clean”
Press the (P) Button “Is the Cavity clear of Debris” Press the (P) Button “Is the Drain Hose Connected” Press the (P) Button “Steam Cycle”
Water Spritz for 1 second every 20 seconds From 450°F to 300°F Water Spritz for 2 second every 20 seconds From 300°F to 200°F
Sequence Time Count Down Time
Pre-Rinse Time 3:00 1:20
Fill Time 1:45 1:17
Chemical Time 3:45 1:16
Wash Time 45:00 1:12 Rinse Time 5:00 0:25
Pump Fill Time 2:30 0:20
Purge Time 2:00 0:17
Final Rinse Time 10:00 0:15
Flush Time 2:00 0:05
Drain Time 3:00 0:03
Maintains Set Temp 180F
Turn Oven Off Wipe Cavity Clean
NOTE: Fill times are based on 20 PSI inlet flow pressure
Page 18
Page 19
NOTES: ___________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
Loading...