Blodgett KLS-80G Operation Manual

KLS-80G and KLS-100G
GAS FIRED TRI-LEG STATIONARY KETTLE
INSTALLATION – OPERATION – MAINTENANCE
BLODGETT OVEN COMPANY
www.blodgett.com
44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone (800) 331-5842, (802) 860-3700 Fax: (802) 864-0183
S00072 Rev C (12/07)
1
It is recommended that this manual be read thoroughly and that all instructions be followed carefully.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapours or liquids in the vicinity of this or any other appliance.
WARNING: Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment.
PURCHASER: Instructions to be followed in the event that the operator of this appliance smells gas must be posted in a prominent location. This information shall be obtained by consulting the local gas supplier.
Do not obstruct the flow of combustion and ventilation air.
Keep the appliance area free and clear from combustibles.
Adequate clearances must be maintained for servicing and proper operation.
Do not attempt to operate this unit in the event of a power failure.
Intended for commercial use only. Not for household use.
This manual should be retained for future reference.
2
TABLE OF CONTENTS
DESCRIPTION PAGE
1.0 Service Connections....................................................................................................4
2.0 Installation ...................................................................................................................5
3.0 Operation...................................................................................................................11
4.0 Cleaning Instructions .................................................................................................16
5.0 Maintenance ..............................................................................................................20
6.0 Service ....................................................................................................................21
7.0 Troubleshooting .......................................................................................................25
Appendix A, Material Safety Data Sheet .........................................................................26
3
1.0 SERVICE CONNECTIONS
Supply gas through 3/4" pipe.
Unless otherwise specified, Field Wire Electrical Connection to be 120 Volts, 60 Hertz single phase with grounding wire. Unit furnished with 6' cord and 3 prong plug. Total max. amps 2.0.
GAS SUPPLY
MODEL
KLS-80G KLS-100G
6"-14"(152-355mm)
SUPPLY PRESSURES (W.C.)
Natural
Propane
11"-14"(279-355mm)
BTU/HR.
150,000
kW/HR.
44
25 5/8 [652] 28 5/8 [727]
OPEN 6.88 [175] CLOSED 5 [128]
25 3/8 [645] KLS-80G
30 [762] KLS-100G
°
5
4
°
5
.
2
2
2" VALVE)
23 1/2 [598]
Ø41 5/8 [1057]
Ø35 1/2 [902]
18 7/8 [479]
20 3/4 [527]
18 13/16 [478]
14 1/8 [358]
8 1/8 [207]
35 5/8 B.C.
Ø
88[2235] KLS-80G
92 5/8 [2352] KLS-100G
DIMENSIONS ARE IN INCHES [MM]
°
0
3
0
44 5/8 [1133] KLS-80G
49 1/4 [1251] KLS-100G
6
°
FLANGED FOOT DETAIL
4
EQUALLY SPACED
7/16" [11mm] HOLES
Ø ON 3 [76] B.C.
6 [152]
7 1/4 [184]
2 [51]
4
2.0 INSTALLATION
INSTALLATION CODES AND STANDARDS
Installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1, as applicable.
1. The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of ½ psi (3.5 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).
Electrical grounding must be provided in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable.
Ventilation must be provided in accordance with local codes, or in the absence of local codes, with ANSI/NFPA 96 Standard for Ventilation and Fire Protection of Commercial Cooking
Operations.
The electrical diagram is located on the inside of the console control cover.
EXHAUST FANS AND CANOPIES: Canopies are set over ranges, ovens and kettles for ventilation purposes. It is recommended that a canopy extend 6" past appliance and be located
7.5 feet from the floor. Filters should be installed at an angle of 45 degrees or more with the
horizontal. This position prevents dripping of grease and facilitates collecting the run-off grease in a drip pan, usually installed with the filter. A strong exhaust fan tends to create a vacuum in the room and may interfere with burner performance or may extinguish pilot flames. Makeup air openings approximately equal to the fan area will relieve such vacuum. In case of unsatisfactory performance on any appliance, check operation with exhaust fan in the “OFF” position.
WALL EXHAUST FAN: The exhaust fan should be installed at least 2 feet above the vent opening at the top of the unit.
CLEARANCES: Adequate clearance must be provided in aisle and at the side and back. Adequate clearances for air openings into the combustion chamber must be provided, as well as for serviceability.
SIDES - 6 INCHES
BACK - 2 INCHES AT FLUE BOX
FLOORS - 6 INCH LEGS
5
All units must be installed in such a manner that the flow of combustion and ventilation air are not obstructed. Provisions for an adequate air supply must also be provided. Do not obstruct the lower front or right side of the unit, as combustion air enters through these areas. The bottom of the control area must also remain obstructed.
2.0 INSTALLATION (Continued)
TO INSTALL
1) Uncrate carefully. Report any hidden freight damage to the freight company immediately.
2) Set the unit in place. Be certain to maintain minimum clearances as stated above.
3) To level the unit use a spirit level in all directions on the top of the kettle (lid up).
a.) Units with legs - adjust the bottom foot on each leg to overcome an uneven floor.
b.) Units with casters - loosen the locking nuts, turn casters in or out as required and tighten locking nuts.
4) Be certain to leave adequate clearances for cleaning, maintenance and service.
5) The pressure relief valve is located at the left rear of the unit. This area should be kept clear and should not be in an area where operators will normally stand. The elbow on the relief valve should be turned toward the floor. A maximum 3 foot, 3/4" diameter pipe may be used to extend to the floor, but must not be piped directly to a drain. It must vent to the atmosphere.
6) Check the pressure gauge on the front panel before operating. If the pressure gauge does not indicate green vacuum zone (below 0 psi), see “Re-establishing Vacuum” section under SERVICE, after completing installation instructions.
GAS CONNECTION
WARNING: Do not connect the appliance to the electrical supply until after the gas connection has been made.
WARNING: The pipe thread compound used when installing pipes must be a type that is resistant to the action of liquified petroleum or propane gases.
6
2.0 INSTALLATION (Continued)
The serial plate on the lower right side of the unit indicates the type of gas your unit is equipped to burn. Do NOT connect to any other gas type.
A ¾" NPT line is provided at the rear for the connection. Each unit is equipped with an internal pressure regulator which is set for 4" W.C. manifold pressure for natural gas and 10" W.C. for propane gas. Use 1/8" pipe tap on the burner manifold for checking pressure.
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas required for satisfactory performance. A steady pressure, minimum 6" W.C. for natural gas and minimum 11" W.C. for propane gas, is recommended. With all units operating simultaneously, the manifold pressure on all units should not show any appreciable drop. Fluctuations of more than 25% on natural gas, and 10% on propane gas, will create pilot problems and affect burner operating characteristics. Contact your gas company for correct supply line sizes.
Purge the supply line to clean out any dust, dirt, or other foreign matter before connecting the line to the unit. It is recommended that an individual manual shut off valve be installed in the gas supply line to the unit. Use pipe joint compound which is suitable for use with LP gas on all threaded connections. Test pipe connections thoroughly for gas leaks.
WARNING: Never use an open flame to check for gas leaks. Check all connections for leaks using soapy water before use.
NOTICE: If applicable, the vent line from the gas appliance pressure regulator shall be installed to the outdoors in accordance with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code CSA B149.1, as applicable.
NOTICE: If this equipment is being installed at over 2,000 feet altitude and was not so specified on order, contact service department. Failure to install with proper orifice sizing may void the warranty.
7
2.0 INSTALLATION (Continued)
WARNING: If this appliance is equipped with casters, the installation shall be made with a connector that complies with the standard for connectors for moveable gas appliances, ANSI Z21.69-CSA 6.16 and a quick-disconnect device that complies with the standard for quick­disconnect devices for use with gas fuel, ANSI Z21.41-CSA 6.9; adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick­disconnect device or its associated piping to limit the appliance movement. Restraint means may be connected to bracket mounted near gas supply connection.
If the unit is also equipped with an optional water fill valve it too must be installed with a flexible water supply tube, a quick disconnect and strain relief.
WATER CONNECTION
On units equipped with an optional water fill valve connect a water line (minimum 1/4") to the valve with a 1/4" NPT female fitting. Units with dual (hot and cold) valves must have the hot water line connected to side with the hot water valve (red) and cold water line to the cold water valve (blue). Plastic or rubber hose is not recommended, as it may melt against the hot kettle side.
8
2.0 INSTALLATION (Continued)
ELECTRICAL CONNECTION
WARNING: Do not connect the kettle to the electrical supply until after the gas connection has been made.
1. 120 VAC - 60 Hz - Single Phase
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. (120V units only.)
Units with this electrical rating are factory supplied with a three-wired cord and three-prong plug which fits any standard 120V, three-prong grounded receptacle. A separate 15 amp supply is needed for each unit.
1. 208/240 VAC - 60 Hz - Single and Three Phase
Units with this electrical rating are factory equipped with a transformer. To connect supply wires remove cover from transformer box at right rear of unit. Route supply wires and ground wire through the hole in the cover with a strain relief fitting. Connect wires to the primary transformer relief fitting. Connect wires to the primary transformer terminals as required by your power supply voltage. Connect ground wire to lug. Replace cover. Three­phase units are wired as above, using only two supply wires. The third supply wire is not connected and must be properly terminated.
1. 220 VAC - 50 Hz - Single Phase
Units equipped with this voltage ratings should be wired exactly as in (2.) above.
9
2.0 INSTALLATION (Continued)
PERFORMANCE CHECK
The following items should be checked before or within the first 30 days of operation by a qualified service technician.
1. Verify correct gas type against rating plate on unit.
2. Verify correct voltage, cycle and phase against rating plate on unit.
3. Gas pressure.
4. Internal gas connections.
5. Internal electrical connections.
6. Pilots - adjustment and ignition.
7. Burners - adjustment and ignition.
8. Thermostat - cycle for operation check.
9. Supply valve - check for operation.
10. Check hinge and lid assembly.
11. Draw-off valve - check operation.
12. Advise user on cleaning procedure.
10
3.0 OPERATION
CAUTION: If you smell gas during the lighting procedure, immediately shut off the gas supply until the leak has been corrected.
WARNING: In the event of main burner ignition failure, a 5 minute purge period must be observed prior to re-establishing ignition source.
WARNING: In the event you smell gas, shut down equipment at the main shut off valve and contact the local gas company or gas supplier for service.
GAS CONTROL INSTRUCTIONS
The units do not require “lighting” the pilot with a match.
A. Lighting
1. Turn thermostat to “OFF” position and power switch to “OFF” position.
2. Open control panel access door located on right side at bottom.
3. Turn dial on combination gas control to “ON” position by rotating control dial counter-
clockwise. NOTE: Any gas service valves exterior to the unit must be open.
4. Turn power switch to “ON” position.
5. Set “COOK TEMP” to desired setting. The red “COOKING” pilot will be on until desired
setting has been reached.
11
3.0 OPERATION (Continued)
At this time the spark igniter will begin sparking at the burner. If after 4 seconds the burner does not light, the control will attempt to relight the burner two additional times at an interval of about 20 seconds.
NOTE: Should the red “COOKING” pilot not come on when the thermostat has been set to the desired setting, the unit has gone in to lock out and a five minute period of complete shut down is required before restarting.
After three trials for ignition, if flame is not established the unit will lockout, shutting off all gas. New installations (where there may be a considerable amount of air in the gas line) may require the unit to be turned off and immediately back on numerous times after each lockout period until the air is purged from the gas line.
B. Shut Down
1. Standby
1. Place power switch and thermostat to “OFF” position.
2. Complete
1. Place power switch and thermostat to “OFF” position.
2. Turn dial on combination gas control from “ON” to “OFF” position.
3. Close any main gas service valves supplying gas to the appliance.
Relighting
1. Turn power switch to “ON” position.
12
3.0 OPERATION (Continued)
FRONT PANEL CONTROLS
1. Power Switch
This switch turns the main power to the unit on and off. It must be turned on to heat the
kettle. It should be turned off when the kettle will not be in use for some time.
2. (Red) Cooking Light
This light is on whenever the main burner flames are on.
3. (Amber) Low Water Light
All kettles are supplied with sufficient distilled water in the pressurized jacket. If at any time the water level falls below that required for proper operation, the kettle will not heat and this light will come on. See “Adding Water” section of service instructions.
4. Thermostat
The thermostat selects the desired internal kettle operating temperature.
5. Pressure Gauge
The pressure gauge indicates the internal operating pressure of the kettle. When cold, the gauge should be in green vacuum zone (below 0 psi). If it is not, refer to “Re-establishing Vacuum” section of service instructions. Under normal operation with the kettle empty (thermostat set at 267 degrees Fahrenheit) the pressure shall reach 25 psi. When loaded, the pressure may be considerably less.
6. Sight Glass
The sight glass indicates the minimum and maximum water level within the kettle jacket. If water level falls below minimum level, more distilled water should be added. See “Adding Water” section of service instructions.
7. Pressure Relief Valve
The pressure relief valve is a safety device which prevents the internal kettle pressure from ever exceeding 35 psi. It should never be tampered with.
13
3.0 OPERATION (Continued)
DAILY OPERATION
Daily operation should consist of turning on the power switch and setting thermostat for the desired temperature. The thermostat will cycle the burners on and off to maintain desired temperature.
It is recommended the kettle be preheated prior to use. Milk or egg based products should be placed in the kettle before heating however, to prevent sticking. The kettle is preheated when the cooking light goes off the first time.
At the end of the day, or if the kettle will not be used for some time, shut the unit down by turning the power switch to “OFF”.
Clean as required or on a daily basis. See “Cleaning” section under MAINTENANCE.
WARNING: When this appliance is installed with casters and is connected to the supply piping by means of a connector for moveable appliances, a restraint to prevent damage to the connector or quick disconnect device should have been installed. If disconnection of the restraint is necessary, reconnect this restraint after the appliance has been returned to its originally installed position.
After igniting the main burners, the spark ignitor acts as a flame sensor. If it does not detect flame, due to gas interruption or excessive air draft, the main burner gas flow will be shut off. The ignition module will then automatically try to relight the main burner in approximately 20 seconds, two additional times. The red cooking light will be on when burners are on and off when burners are off.
END USE TIPS
For easier cleaning add cold water to the kettle immediately after removing contents.
When preparing foods containing vinegar or tomatoes, or those which have a high salt content, clean the kettle immediately after using to prevent pitting.
Do not use salt to clean the kettle. This will scratch the surface.
If using salt water to cook shellfish, be sure to rinse and wash the kettle thoroughly after use.
Bring milk and egg products slowly up to temperature in a cold kettle to prevent product from
14
adhering to the sides. When preparing milk-based products do not preheat the kettle.
When planning actual cooking capacity, allow room at top for stirring without spilling.
When preparing puddings from a mix, place the powder in a cold kettle, add a small amount of liquid, and stir to form a thin paste. Turn on the kettle and add the remainder of the liquid. Continue as per recipe instructions.
When browning meat, bring the kettle up to temperature before adding. This will seal the juices in the meat.
VENT SYSTEM: At least twice a year the unit venting system should be examined and cleaned.
GAS SAVING TIPS
Use these reminders to help develop energy-saving procedures and habits. Using less natural or propane gas saves energy as well as money.
1. Turn off when not in use.
2. Limit preheat times.
3. Use lid when possible.
4. Maintain equipment.
15
4.0 CLEANING INSTRUCTIONS
WARNING: Disconnect the power supply to the appliance before cleaning or servicing.
WARNING: Never spray water into electric controls or components!
CAUTION: The equipment and its parts are hot. Use care when operating, cleaning and servicing.
CAUTION: Do not use cleaning agents that are corrosive.
Your kettle should be cleaned immediately after each use or when cooking a different product. Before cleaning, check that the kettle has cooled enough to touch it.
1. Rinse the inside of the kettle thoroughly and drain to remove any food particles.
2. Using a nylon brush, clean the kettle with a mild detergent and water. Never use steel wool or scouring powder as it will scratch stainless steel. Plain steel wool can leave small pieces of steel which can rust.
3. Rinse the inside of the kettle thoroughly with clean water. Drain the kettle by tilting or the tangent draw-off valve, depending on model, to allow the detergent and water solution to drain.
4. Wipe the exterior of the kettle with a clean, damp cloth.
WARNING: If you are cleaning a valve that is assembled to a kettle, be sure the kettle is completely empty of any product.
16
4.0 CLEANING INSTRUCTIONS (Continued)
DRAW-OFF VALVE CLEANING
1. If equipped with a tangent draw-off valve, turn the large hex nut on the draw-off valve counterclockwise until it is completely disengaged from the threads. Grasp the valve knob and slowly pull out the valve stem and disk. Do not allow the disk to come in contact with hard surfaces as it can be damaged and cause valve leakage. Wash the valve stem, disk and handle. Insert a nylon brush, wet with detergent and water, into the valve body and tangent draw-off tube. Brush vigorously.
2. Replace the valve stem assembly and turn the hex nut until snug. Rinse the kettle with clean warm water.
3. Leave the draw-off valve open when the kettle is not in use.
DAIRY DRAW-OFF VALVE CLEANING
1. Remove the plug by first removing the handle, then turn the plug to line up with the pin and pull with both hands. It is important to use both hands because the plug is heavy.
2. Put the plug in a plastic pail that contains a mild soap solution. A plastic pail works best, as it reduces the possibility of nicking or scratching the plug. If the plug gets scratched it may not seal correctly and could leak.
3. Use a soft cloth or soft brush and clean all surfaces.
4. Using both hands remove the valve from the soap and rinse well in another plastic pail that contains fresh water.
5. Wash out the kettle as normal.
6. Once the kettle is washed out, return the plug into the body. Be sure the plug is inserted into the notch and turned. Ensure the plug is tight and secure before letting go of it.
If you are cleaning a body and plug assembly, remove the plug and follow the above procedures. When finished with the plug, follow the same instructions for washing the body. Always use both hands when handling the plugs. Reassemble the plug into the body and use as normal.
17
4.0 CLEANING INSTRUCTIONS (Continued)
WHAT TO DO IF SURFACE RUST APPEARS
Metal utensils should never be used as they will scratch the surface of the equipment and rust may begin to form. To remove surface accumulation of rust from the inadvertent use of such utensils, the following procedure may be used.
CAUTION: Improper use of this procedure may damage your appliance!
1. Use undiluted white vinegar with a non-abrasive scouring pad (plastic) or cloth on the affected area to remove the rust stain. The appliance should not be heated and remain at room temperature during the entire cleaning process.
2. If the stain resists removal, additional exposure time with vinegar may be required, to a maximum of one hour.
3. Thoroughly wash all of the vinegar away with fresh clear water. Dry the surface completely and allow one hour before using the appliance to cook.
Following daily and period maintenance procedures will prolong the life for your equipment. Climatic conditions - salt air - may require more thorough and frequent cleaning or the life of the equipment could be adversely affected.
STAINLESS STEEL
To remove normal dirt, grease or product residue from stainless steel, use ordinary soap and water (with or without detergent) applied with a sponge or cloth. Dry thoroughly with a clean cloth. Never use vinegar or any other corrosive cleaner.
To remove grease and food splatters or condensed vapors that have baked on the equipment, apply cleanser to a damp cloth or sponge and rub cleanser on the metal in the direction of the polishing lines. Rubbing cleanser as gently as possible in the direction of the polished lines will not mar the finish of the stainless steel. NEVER RUB WITH A CIRCULAR MOTION.
Soil and burn deposits which do not respond to the above procedure can usually be removed by rubbing the surface with SCOTCH-BRITE™ scouring pads or STAINLESS scouring pads. DO NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust and further spoil the appearance of the finish. NEVER USE A WIRE BRUSH, STEEL SCOURING PADS (EXCEPT STAINLESS), SCRAPER, FILE OR OTHER STEEL TOOLS. Surfaces which are marred collect dirt more rapidly and become more difficult to clean. Marring also increases the possibility of corrosive attack. Refinishing may then be required.
18
4.0 CLEANING INSTRUCTIONS (Continued)
STAINLESS STEEL
TO REMOVE HEAT TINT: Darkened areas sometimes appear on stainless steel surfaces
where the area has been subjected to excessive heat. These darkened areas are caused by thickening of the protective surface of the stainless steel and is not harmful. Heat tint can normally be removed by the foregoing, but tint which does not respond to this procedure calls for a vigorous scouring in the direction of the polish lines using SCOTCH-BRITE™ scouring pads or a STAINLESS scouring pad in combination with a powdered cleanser. Heat tint action may be lessened by not applying or by reducing heat to equipment during slack periods.
All food contact surfaces must be thoroughly drained and flushed prior to cooking in the kettle.
CONTROL PANEL: The textured control panel should be cleaned with warm water and mild soap. Never use an abrasive cloth or steel wool. Never use cleaning solvents with a hydrocarbon base.
19
5.0 MAINTENANCE
Contact the factory, the factory representative or a local service company to
perform maintenance and repairs.
WARNING: Disconnect the power supply to the appliance before cleaning or servicing.
Daily:
1. Wash exposed cleanable areas.
Monthly:
1) Clean around burner air mixers and louvered panels if grease or lint have accumulated.
TWICE A YEAR: (minimum)
Have an authorized service person clean and adjust the unit for maximum performance.
It is NOT RECOMMENDED to use cleaning agents that are corrosive.
Use of cleaning agents that contain chloride, acids or salts are corrosive and may cause pitting and corrosion when used over a period of time; this will reduce life of the appliance.
Should pitting or corrosion occur this is not covered by warranty.
Follow the recommended cleaning instructions. Use a mild detergent, warm water and rinse thoroughly.
Never spray water into electric controls.
NOTICE: Draw-off valve has a vulcanized rubber coated stem for better sealing. Do not over tighten. This may cause the rubber to pull away from stem and permanently damage it. This is not covered under warranty.
20
6.0 SERVICE
GENERAL
CAUTION: Operating, testing, and servicing should only be performed by qualified personnel.
When any difficulty arises always check that the unit has been connected to the gas supply type and voltage for which it was supplied. This can be done by examining the serial plate on the lower right side of the unit. It will list the gas type and voltage for which the unit was manufactured.
Wiring diagrams for the unit are located in a small envelope affixed to the rear side of the front control panel.
Orifice Size (0 - 2000 ft.)
Unit Total Input Natural Propane
KLS-80G and KLS-100G
MANIFOLD PRESSURE
Natural Gas - 4 inches W.C. LP Gas - 10 inches W.C.
GAS PRESSURE REGULATOR
The gas pressure regulator is an integral part of the combination gas control located just behind the lower front access door. The pressure regulator adjustment is on the lower right side of the gas control. The large slotted cap must be removed to access the adjustment screw.
ADJUSTMENTS
To check the manifold pressure a pressure gauge (manometer) must be connected to the 1/8" NPT pressure tap on the gas manifold. With the gas off, connect your pressure indicating instrument to the manifold with a fitting appropriate for your instrument.
Turn the unit on; with main burners on, read the manifold pressure. The pressure should be 4 inches water column (W.C.) (") .2 inches W.C. for natural gas or 10 inches W.C. for propane gas. Adjust the pressure regulator to obtain the appropriate pressure. Check serial plate on lower right side of unit to confirm exact gas type and manifold pressure for your unit.
150,000 BTU/Hour #29 #44
21
When pressure has been correctly adjusted turn unit off. Remove pressure indicating instrument and replace the 1/8" NPT plug in manifold. Replace regulator cap and close access door.
THERMOSTAT
The thermostat has been factory set and should not require adjustment. Adjustment may be made if an operating pressure deficiency has been determined and that the thermostat is the cause. Adjustment is made by using the set screw inside the stem. Turn the set screw clockwise to decrease pressure and counterclockwise to increase. The thermostat should cycle off at a gauge pressure reading of 25 psi. A voltmeter should be used by a properly trained serviceman to determine if the pressure switch or thermostat is actually cycling the burners.
PRESSURE SWITCH
The pressure switch is factory set and should not be adjusted unless it is determined to be the cause of an operating pressure deficiency. A voltmeter should be used by a properly trained serviceman to determine if the pressure switch or thermostat is actually cycling the burners.
The major difficulties caused by pressure switch mis-adjustment are:
1. Pressure relief valve opening, especially on preheat from a cold start to 267 degrees Fahrenheit (130EC) (pressure switch set too high).
2. Burners are being shut down by pressure switch, not the thermostat. (Pressure in kettle is
too low.)
The pressure switch is preset for proper operation from the factory. It is preset to 30 psi on pressure gauge. During preheat to the maximum thermostat setting (267 degrees Fahrenheit) (130EC), from either a cold condition or a lower temperature setting, the temperature may overshoot the thermostat setting and shut down the burners by the pressure switch. This is normal, however, after the kettle cycles several times (empty) the thermostat will begin cycling the unit.
TO ADJUST PRESSURE SWITCH:
1. To obtain access to the pressure switch, the front panel must be removed. Remove the
screws on either side of the panel.
2. To increase the pressure setting turn the white ribbed knob clockwise; to decrease the
pressure, turn it counterclockwise. Use the center of the black ring as an indicator.
3. Take thermostat out of circuit by removing the blue wire from the thermostat terminal and
attaching it to the piggy-back terminal on the other side of the thermostat.
4. With the kettle empty and completely cold, turn kettle on.
22
5. Pressure in kettle (read pressure gauge on front panel) should reach a maximum of 30 psi
and pressure relief valve should not open. Kettle pressure may rise 2 or 3 psi even after burners shut down.
6. Relief valve should not open when kettle pressure is 30 psi.
7. If relief valve opens, reduce setting on pressure switch, cool kettle completely by running
cold water through it and repeat steps 3 - 6.
8. If pressure in kettle is below 30 psi increase setting of pressure switch, cool kettle
completely by running cold water through it and repeat steps 3 - 7.
9. Replace the blue wire from the piggy-back terminal on the thermostat back to its original
position.
10. Replace the front panel when adjustment is complete.
ADDING WATER
It may be necessary to replenish water in the jacket when the low water indicator comes on. Do so as follows:
1. Unit should be completely cold and off.
2. Lift handle of pressure relief valve to release vacuum in kettle (relief valve is at left rear of
kettle).
3. Remove air vent nut on the elbow located at the rear left of the unit.
4. Using pure distilled water only, pour the water into the opening (a funnel will be helpful).
Water will enter the kettle slowly, as air must escape through the same hole. Water should be added until the water level at the sight glass is half way between the minimum and maximum levels.
5. When sufficient water has been added, replace and tighten the nut.
6. Vacuum must now be re-established. See following section.
23
RE-ESTABLISHING VACUUM
Periodically check pressure gauge when kettle is cold. Reading should be in green vacuum zone (below 0 psi). Otherwise air is present and proper heating will not occur. Use the following procedure to remove air and re-establish vacuum:
With the kettle empty, turn the thermostat knob to the highest temperature. When the temperature pilot light goes off, open air vent nut one (1) full turn for 20 seconds and then close and tighten the nut. This should remove the air and any loss in performance should return.
Should the kettle fail to maintain a vacuum after repeated attempts to establish vacuum, further checks should be made to see if the pressure relief valve is leaking or if there are any leaks in the pressure relief valve piping, copper lines going to the pressure switch, pressure gauge or thermostat fitting.
CONTROL CIRCUIT FUSES
The control circuit is protected by a 3 amp fuse which is located inside the control panel, top right side (120V units).
Should the unit fail to turn on, check this fuse by removing it and either replacing it or testing it with a continuity tester. If the fuse is good, check the main power circuit breaker, external to the kettle.
24
7.0 TROUBLESHOOTING
PROBLEM LOOK FOR
Unit will not come on. - Power switch is off.
- Unit not plugged in.
- Main power supply off.
- Faulty electronic module.
- Faulty low water control.
- Faulty igniter/sensor.
- Fuse in unit blown.
Unit will turn on electrically but will not heat. - Lockout has occurred.
- Thermostat not on.
- Gas control valve off.
- Main gas supply off.
- Low water.
- Faulty thermostat.
- Faulty pressure switch.
- Faulty gas control valve.
- Faulty or mislocated spark igniter/sensor.
- Faulty igniter cable - shorting to ground.
- Faulty gas control.
Excessive flame rollout on ignition, carboning.
- Natural gas unit on propane.
- Excessive gas pressure.
- Incorrect orifice size.
- Faulty regulator in gas control.
Unit slow to preheat and slow to recover. - Propane gas on natural.
- Low gas pressure.
- Incorrect orifice size.
- Loss of vacuum.
- Faulty regulator in gas control.
Unit continuously locks out.
- Excessive draft condition.
- Excessive steam around bottom of unit during operation of cleaning.
- Faulty electronic module.
- Ignitor cable damaged or shorting to ground.
- Faulty or mislocated spark igniter/sensor.
- Faulty gas control.
25
APPENDIX ‘A’
MATERIAL SAFETY DATA SHEET
PREPARATION INFORMATION:
Prepared for use in Canada by: E H & S Product Regulatory Management Department
DOW CHEMICAL CANADA INC. P.O. Box 1012 Sarnia, Ontario, N7T 7K7
(800) 331-6451
1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
IN CASE OF EMERGENCY: Fort Saskatchewan, Alberta: (780) 998-8282
Sarnia, Ontario: (519) 339-3711 Varennes, Quebec: (450) 652-1000
Product: DOWFROST* HD HEAT TRANSFER FLUID, DYED
Product Code: 04632
Effective Date: 2/20/01 Date Printed: 07/10/02 MSD: 002239
DOW CHEMICAL CANADA INC. P.O. Box 1012 Sarnia, Ontario, N7T 7K7
Prepared for use in Canada by the E H & S Product Regulatory Management Department; Phone: (800) 331-6451.
2. COMPOSITION/INFORMATION ON INGREDIENTS
Propylene Glycol CAS# 000057-55-6 94% Dipotassium Phosphate CAS# 007758-11-4 <5% Deionized Water CAS# 007732-18-5 <5%
26
EMERGENCY OVERVIEW
Clear yellow liquid. Odorless. Avoid temperatures above 450EF, 232EC.
POTENTIAL HEALTH EFFECTS (See Section 11 for toxicological data.)
EYE: May cause slight transient (temporary) eye irritation. Corneal injury is unlikely. Mists
may cause eye irritation.
SKIN CONTACT: Prolonged contact is essentially non-irritating to skin. A single prolonged exposure is not likely to result in the material being absorbed through skin in harmful amounts. Repeated exposures may cause flaking and softening of skin.
INGESTION: Single dose oral toxicity is considered to be extremely low. No hazards anticipated from swallowing small amounts incidental to normal handling operations.
INHALATION: At room temperature, vapours are minimal due to physical properties. Mists may cause irritation of upper respiratory tract (nose and throat).
SYSTEMIC (OTHER TARGET ORGAN) EFFECTS: Repeated excessive exposure to propylene glycol may cause central nervous system effects.
CANCER INFORMATION: Did not cause cancer in laboratory animals.
TERATOLOGY (BIRTH DEFECTS): Birth defects are unlikely. Exposures having no adverse
effects on the mother should have no effect on the fetus.
REPRODUCTIVE EFFECTS: In animal studies, has been shown not to interfere with reproduction.
27
4. FIRST AID
EYES: Flush eyes with plenty of water.
SKIN: Wash off in flowing water or shower.
INGESTION: No adverse effects anticipated by this route of exposure incidental
to proper industrial handling.
INHALATION: Remove to fresh air if effects occur. Consult a physician.
NOTE TO PHYSICIAN: No specific antidote. Supportive care. Treatment based on
judgment of the physician in response to reactions of the patient.
5. FIRE FIGHTING MEASURES
FLAMMABLE PROPERTIES
FLASH POINT: 214EF, 107EC (based on a similar material)
METHOD USED: PMCC
AUTOIGNITION TEMPERATURE: NOT DETERMINED
FLAMMABILITY LIMITS
LFL: Not determined
UFL: Not determined
HAZARDOUS COMBUSTION PRODUCTS: During a fire, smoke may contain the original material in addition to unidentified toxic and/or irritating compounds. Hazardous combustion products may include and are not limited to carbon monoxide and carbon dioxide.
OTHER FLAMMABILITY INFORMATION: Violent steam generation or eruption may occur upon application of direct water stream to hot liquids. Flammable concentrations of vapour can accumulate at temperatures above 214EF. Liquid mist of this product can burn. Spills of these organic liquids on hot fibrous insulations may lead to lowering of the autoignition temperatures possibly resulting in spontaneous combustion. Container may rupture from gas generation in a fire situation.
EXTINGUISHING MEDIA: Water fog or fine spray, carbon dioxide, dry chemical, foam. Alcohol resistant foams (ATC type) are preferred if available. General purpose synthetic foams (including AFFF) or protein foams may function, but much less effectively. Do not use direct water stream. May spread fire.
28
MEDIA TO BE AVOIDED: Do not use direct water stream.
FIRE FIGHTING INSTRUCTIONS: Keep people away. Isolate fire area and deny unnecessary
entry. Burning liquids may be moved by flushing with water to protect personnel and minimize property damage. Burning liquids may be extinguished by dilution with water. Do not use direct water stream. May spread fire. Fight fire from protected location or safe distance. Consider use of unmanned hose holder or monitor nozzles. Use water spray to cool fire exposed containers and fire affected zone until fire is out and danger of re-ignition has passed. Immediately withdraw all personnel from area in case of rising sound from venting safety device or discolouration of the container. Move container from fire area if this is possible without hazard.
PROTECTIVE EQUIPMENT FOR FIRE FIGHTERS: Wear positive-pressure self-contained breathing apparatus (SCBA) and protective fire fighting clothing (includes fire fighting helmet, coat, pants, boots and gloves). If protective equipment is not available or not used, fight fire from a protected location or safe distance.
6. ACCIDENTAL RELEASE MEASURES (See Section 15 for Regulatory Information)
PROTECT PEOPLE: Use appropriate safety equipment. For additional information, refer to Section 8, Exposure Controls/ Personal Protection.
PROTECT THE ENVIRONMENT: Avoid contamination of all waterways.
CLEAN-UP: See Section 13, Disposal Consideration.
7. HANDLING AND STORAGE
SPECIAL PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE: No special handling requirements data available. HANDLING: See Section 8, Exposure Controls/Personal Protection.
STORAGE: See Section 10, Stability and Reactivity.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
ENGINEERING CONTROLS: Provide general and/or local exhaust ventilation to control airborne levels below the exposure guidelines.
PERSONAL PROTECTIVE EQUIPMENT
EYE/FACE PROTECTION: Use safety glasses. Safety glasses should be sufficient for most operations; however, for misty operations wear chemical goggles.
SKIN PROTECTION: Use gloves impervious to this material.
29
RESPIRATORY PROTECTION: Atmospheric levels should be maintained below the exposure guideline. When respiratory protection is required for certain operations, use an approved air­purifying respirator. In misty atmospheres, use an approved mist respirator.
EXPOSURE GUIDELINES: Propylene glycol: AIHA WEEL is 50 ppm total, 10 mg/m3 aerosol only.
9. PHYSICAL AND CHEMICAL PROPERTIES
APPEARANCE/PHYSICAL STATE: Clear yellow liquid. ODOUR: Odorless VAPOUR PRESSURE: 0.22 mmHg @ 20EC VAPOUR DENSITY: 2.6 BOILING POINT: 320EF, 160EC SOLUBILITY IN WATER/MISCIBILITY: Complete SPECIFIC GRAVITY OR DENSITY: 1.058 @ 25/25EC
10. STABILITY AND REACTIVITY
CHEMICAL STABILITY: Thermally stable at typical use temperatures.
CONDITIONS TO AVOID: Avoid use temperatures above 450EF, 232EC. Product can degrade at elevated temperatures. Generation of gas during decomposition can cause pressure in closed systems.
INCOMPATIBILITY WITH OTHER MATERIALS: Avoid contact with oxidizing materials. Avoid contact with strong acids
HAZARDOUS DECOMPOSITION PRODUCTS: Hazardous decomposition products depend upon temperature, air supply and the presence of other materials.
HAZARDOUS POLYMERIZATION: Will not occur.
11. TOXICOLOGICAL INFORMATION (See Section 3 for Potential Health Effects. For
detailed toxicological data, write or call the address or non-emergency number shown in Section 1).
SKIN: The LD50 for skin absorption in rabbits is >10,000 mg/kg.
SKIN: The LD50 for skin absorption in rabbits is >10,000 mg/kg.
INGESTION: The oral LD50 for rats is 20,000 - 34,000 mg/kg.
MUTAGENICITY: In vitro mutagenicity studies were negative. Animal mutagenicity studies
were negative.
30
12. ECOLOGICAL INFORMATION (For detailed Ecological data, write or call the address or
non-emergency number shown in Section 1.)
ENVIRONMENTAL FATE
MOVEMENT & PARTITIONING: Based largely or completely on data for major component(s). Bioconcentration potential is low (BCF less than 100 or Log Pow less than 3). Potential for mobility in soil is very high (Koc between 0 and 50).
DEGRADATION AND PERSISTENCE: Based largely or completely on data for major component(s). Material is readily biodegradable. Passes OECD test(s) for ready biodegradability. Degradation is expected in the atmospheric environment within minutes to hours.
ECOTOXICITY: Based largely or completely on data for major component(s). Material is practically non-toxic to aquatic organisms on an acute basis (LC50/EC50 >100 mg/L in most sensitive species).
13. DISPOSAL CONSIDERATIONS (See Section 15 for Regulatory Information)
DISPOSAL: DO NOT DUMP INTO ANY SEWERS, ON THE GROUND OR INTO ANY BODY OF WATER. All disposal methods must be in compliance with all Federal, State/Provincial and local laws and regulations. Regulations may vary in different locations. Waste characterizations and compliance with applicable laws are the responsibility solely of the waste generator. THE DOW CHEMICAL COMPANY HAS NO CONTROL OVER THE MANAGEMENT PRACTICES OR MANUFACTURING PROCESSES OF PARTIES HANDLING OR USING THIS MATERIAL. THE INFORMATION PRESENTED HERE PERTAINS ONLY TO THE PRODUCT AS SHIPPED IN ITS INTENDED CONDITION AS DESCRIBED IN MSDS SECTION 2 (Composition/Information On Ingredients).
FOR UNUSED & UNCONTAMINATED PRODUCT, the preferred options include sending to a licensed, permitted: recycler, reclaimer, incinerator or other thermal destruction device.
As a service to its customers, Dow can provide names of information resources to help identify waste management companies and other facilities which recycle, reprocess or manage chemicals or plastics, and that manage used drums. Telephone Dow’s Customer Information Center at 800-258-2436 or 989-832-1556 for further details.
S TRANSPORT INFORMATION
DEPARTMENT OF TRANSPORTATION (D.O.T.): For D.O.T. regulatory information, if
required, consult transportation regulations, product shipping papers, or contact your Dow representative.
CANADIAN TDG INFORMATION: For TDG regulatory information, if required, consult transportation regulations, product shipping papers, or your Dow representative.
31
S REGULATORY INFORMATION (Not meant to be all-inclusive – selected regulations
represented).
NOTICE: The information herein is presented in good faith and believed to be accurate as of the effective date shown above. However, no warranty, express or implied is given. Regulatory requirements are subject to change and may differ from one location to another; it is the buyer’s responsibility to ensure that its activities comply with federal, state or provincial, and local laws. The following specific information is made for the purpose of complying with numerous federal, state or provincial, and local laws and regulations. See other sections for health and safety information.
U.S. REGULATIONS
SARA 313 INFORMATION: To the best of our knowledge, this product contains no chemical subject to SARA Title III Section 313 supplier notification requirements.
SARA HAZARD CATEGORY: This product has been reviewed according to the EPA “Hazard Categories” promulgated under Sections 311 and 312 of the Superfund Amendment and Reauthorization Act of 1986 (SARA Title III) and is considered, under applicable definitions, to meet the following categories:
Not to have met any hazard category.
TOXIC SUBSTANCES CONTROL ACT (TSCA):
All ingredients are on the TSCA inventory or are not required to be listed on the TSCA inventory.
STATE RIGHT-TO-KNOW: The following product components are cited on certain state lists as mentioned. Non-listed components may be shown in the composition section of the MSDS.
CHEMICAL NAME CAS NUMBER
LIST
1, 2-Propanediol 000057-55-6 PA1
PA1= Pennsylvania Hazardous Substance (present at greater than or equal to 1.0%).
OSHA HAZARD COMMUNICATION STANDARD:
This product is not a “Hazardous Chemical” as defined by the OSHA Hazard Communication Standard, 29 CFR 1910.1200.
32
CANADIAN REGULATIONS
WHMIS INFORMATION: The Canadian Workplace Hazardous Materials Information System (WHMIS) Classification for this product is:
This product is not a “Controlled Product” under WHMIS.
CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA)
This product contains one or more substances which are not listed on the Canadian Domestic Substances List (DSL). Contact your Dow representative for more information.
S OTHER INFORMATION
MSDS STATUS: Revised to 16 section format.
The information herein is given in good faith, but no warranty, express or implied, is made. Consult The Dow Chemical Company for further information.