Blodgett CB36G-6-6K User Manual

Project
Item No.
Quantity
Model CB36G-6-6K (two 6 gallon direct steam kettles on a 36” gas boiler
base)
KETTLES
Water resistant, 304 stainless steel construction316 stainless steel interior cooking surface for corrosion resistance2/3 jacketed, hemispherical design on bottom for superior heat circulationTilt mechanism permits kettle to tilt forward past 90° to emptyTubular stainless steel legs containing steam control valve and conden-
sate return pipes
Reversible operating handle with heat proof knob
GAS BOILER BASE
Gas operated steam boiler rated at 15 PSI (103 kPa) operating on
115VAC, 1 phase, 60 Hz rated at 140,000 BTU
Full perimeter painted angle iron frameReinforced counter and boiler mountingsStainless steel exteriorHinged door(s) with magnetic latch6” (152 mm) stainless steel legs with adjustable bullet feet on front and
adjustable flanged feet on rear
Thermostatically controlled drain boxAll piping is confined within cabinetAutomatic water level controlAutomatic boiler blowdownPressure gaugeWater gauge glassPressure control with pressure safety controlSafety relief valveCathodic protectorOn/Off switch with indicator lightElectronic ignitionSplit water linesCSD-1 secondary low water cut off
STANDARD FEATURES
Deck mount hot and cold faucet with riser3"(76mm) deep sinks with splash guards and gratesStartup inspection service by factory autorized service agentOne year parts and labor warranty*
* For all international markets, contact your local distributor
BLODGETT
www.blodgett.com
44 Lakeside Avenue, Burlington, VT 05401 • Phone: (802) 658-6600 • Fax: (802) 864-0183
OPTIONS AND ACCESSORIES
(AT ADDITIONAL CHARGE)
Power Increase
200,000 BTU boiler250,000 BTU boiler300,000 BTU boiler
Etched kettle markings
Gallon markings
Litre markingsFront flanged feetCorrectional packageStainless steel back panel208-240 VAC specify voltageOne year extended warranty
CB36G-6-6K
Two Direct Steam Kettles on a 36” Gas Boiler Base
CB36G-6-6K GAS BOILER BASE WITH KETTLES
BLODGETT
www.blodgett.com
44 Lakeside Avenue, Burlington, VT 05401 • Phone: (802) 658-6600 • Fax: (802) 864-0183
CB36G-6-6K
SHORT FORM SPECIFICATIONS
Provide Blodgett model CB36G-6-6K (6 pan) two 6 gallon direct steam kettles on a 140,000 BTU gas boiler base base. The kettles shall have a double wall interior to form a steam jacket around the lower 2/3 of the kettle. The bottom of the kettle shall be of hemispherical design for superior heat circula-
tion. Steam control valve mounted in leg. The tubular stainless steel mounting legs shall have the steam supply and condensate return pipes completely concealed within the leg meme­bers. The sealed stainless steel tilt mechanism bearings shall permit the kettle to tilt forward 90° for complete emptying. A removeable operating handle with heat proof knob shall be mounted on the left or right. Unit shall have a single support leg with nylon insert. Construction shall be all welded satin finish 304 stainless steel with a 316 stainless steel liner.
The boiler shall be suitable for operation at any pressure from 5-11 PSI (34-76 kPa) and operate on 115 VAC. Boiler shall be mounted in cabinet base. Polished stainless steel cabinet base shall be of modular design to match other Blodgett steam equipment. Unit shall have 6” (152mm) stainless steel legs and adjustable bullet feet, reinforced stainless steel counter top and hinged doors with magnetic latches. All piping shall be confined within the cabinet. Unit shall be automatically filled with water and brought to pressure when power switch is turned on. Cold water condenser shall automatically condense exhausted steam in water before releasing it to drain. Boiler controls shall include automatic water level, pressure gauge, water gauge glass, pressure control with pressure safety control, safety relief valve, cathodic protector and CSD-1 secondary low water cut off.
Unit shall have a hot and cold water faucet with control valves, 5" (152 mm) deep sink with drain and two splash guards. Kettles and boiler shall be ASME code stamped and National Board registered. Provide options and accessories as indicated.
Printed in U.S.A. NOTE: FOR COMMERCIAL USE ONLY
NOTE: The company reserves the right to make substitutions of components without prior notice.
NOTE: SPLASH GUARD NOT SHOWN ON FRONT VIEW
DIMENSIONS ARE IN INCHES [MM]
REAR FLANGED FOOT DETAIL
7/16" [11mm] HOLES
ON 2.5 [63] B.C.
2 EQUALLY SPACED Ø
S
ELECTRICAL CONNECTION: ½”conduit connection to controls. 120 volts, single phase with grounding wire required unless otherwise specified..
GAS CONNECTION: 3/4” IPS supply line required.
STEAM TAKE-OFF CONNECTION: 3/4” IPS optional to operate adjacent equipment.
COLD WATER: 3/8” O.D. tubing at 25-50 PSI (170-345 kPa)
DRAIN: 2” IPS piped to open floor drain. No solid connection.
SINK DRAIN: 1-1/8” O.D. tubing at 25-50 PSI (170-345 Kpa)
S
31 [787]
27 [686]
18 [457]
14.5 [368]
19.33 [491]
32 [813]
6 [152]
7.5 [457]
2.75
[70]
5.75 [146]
Ø12 [305]
S
6.75 [171]
8 [203]
3 [76]
2.38 [60]
26.63 [676]
10 [254]
3 [76]
36 [914]
0.63 [16]
4.88 [124]
33 [838]
APPROVAL/STAMP
P/N S00090 Rev D (12/09)
WATER SUPPLY:
Water quality is a major factor affecting the performance of your steamer. If you are unsure of water quality, consult a local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Total dissolved solids: Less than 60 PPM Total alkalinity: Less than 20 PPM Silica: Less than 13 PPM Chlorine: Less than 1.5 PPM pH Factor: 7.0 - 8.5 Water which fails to meet these standards should be treated by installation of a water conditioner. Failure or malfunction of this steamer due to poor water quality is not cov-
ered under warranty.
WATER & DRAIN CONNECTIONS:
Drain 2” (51mm) IPS piped to open floor drain. No solid connection.
24” length before open air opening (no bends or elbows) Cold Water 3/8” (10mm) tubing at 25-50 PSI (170-345 kPa) Steam Take Off 3/4” IPS optional to operate adjacent equipment Appliance is to be installed with backflow protection in accordance with Federal, State or
Local codes.
GAS SUPPLY:
3/4" IPS supply line required
Minimum Inlet Pressure:
Natural 7.0" W.C. static to unit Propane 11.0" W.C. static to unit
POWER SUPPLY:
Unless otherwise specified, field wire electrical con­nection to be 120VAC, single phase, 60 Hz with grounding wire.
PRODUCT CLEARANCE
Right and Left side 3” (76mm) Rear 6” (152mm)
SHIPPING INFORMATION:
Approx. Weight:
CB36G-6-6K 610 lbs. (277 kg)