Blodgett CB24-140G General Manual

Project
Item No.
Quantity
Model CB24-140G ( 24” wide 140,000 BTU gas boiler base cabinet)Model CB24-200G ( 24” wide 200,000 BTU gas boiler base cabinet)Model CB36-140G ( 36” wide 140,000 BTU gas boiler base cabinet)Model CB36-200G ( 36” wide 200,000 BTU gas boiler base cabinet)Model CB36-250G ( 36” wide 250,000 BTU gas boiler base cabinet)Model CB36-300G ( 36” wide 300,000 BTU gas boiler base cabinet)
CONSTRUCTION
Full perimeter painted angle iron frameReinforced counter and boiler mountingsStainless steel exteriorHinged door(s) with magnetic latch6” (152 mm) stainless steel legs with adjustable bullet feet on front and
adjustable flanged feet on rear
All piping is confined within cabinet
OPERATION
Automatic water level controlAutomatic boiler blowdownPressure gaugeWater gauge glassPressure control with pressure safety controlSafety relief valveCathodic protectorOn/Off switch with indicator lightCSD-1 secondary low water cut off
STANDARD FEATURES
Gas operated steam boiler rated at 15 PSI (103 kPa) operating on
115VAC
Electronic ignitionSplit water linesOne year parts and labor warranty*
* For all international markets, contact your local distributor.
BLODGETT COMBI
www.blodgett.com
44 Lakeside Avenue, Burlington, VT 05401 • Phone: (802) 658-6600 • Fax: (802) 864-0183
OPTIONS AND ACCESSORIES
(AT ADDITIONAL CHARGE)
Foot Options
Front flanged feet
Rear flanged feetPressure reducing valveStainless steel rear panelStainless steel frameSteam take off kitWater in “Y” strainerBall float trap208-240VAC operation (specify voltage)Correctional packageOne year extended warranty
CB-G
Gas Steam Boiler
CB-G GAS STEAM BOILER
CB-36G shown
BLODGETT COMBI
www.blodgett.com
44 Lakeside Avenue, Burlington, VT 05401 • Phone: (802) 658-6600 • Fax: (802) 864-0183
CB-G ELECTRIC STEAM BOILER
SHORT FORM SPECIFICATIONS
Provide Blodgett model CB24-140G (140,000 BTU) or CB24-200G (200,000 BTU 24” wide gas steam boiler cabinet, or CB36-140G (140,000 BTU), CB36-200G (200,000 BTU), CB36­250G (250,000 BTU) or CB36-300G (300,000 BTU) 36” wide gas steam boiler cabinet. Unit shall be suitable for operation at any pressure from 5-11 PSI (34-76 kPa) and operate on 115 VAC. Boiler shall be mounted in cabinet base. Polished stainless steel cabinet base shall be of modular design to match other Blodgett steam equipment. Unit shall have 6” (152mm) stainless steel legs and adjustable bullet feet, reinforced stainless steel counter top and hinged doors with magnetic latches. All piping shall be confined within the cabinet. Unit shall be automatically filled with water and brought to pressure when power switch is turned on. Cold water condenser shall automatically condense exhausted steam in water before releasing it to drain. Boiler controls shall include automatic water level, pressure gauge, water gauge glass, pressure control with pressure safety control, safety relief valve, cathodic protector and CSD-1 secondary low water cut off. Boiler shall be ASME code stamped and National Board registered. Provide options and accessories as indicated.
WATER SUPPLY:
Water quality is a major factor affecting the performance of your steamer. If you are unsure of water quality, consult a local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Total dissolved solids: Less than 60 PPM Total alkalinity: Less than 20 PPM Silica: Less than 13 PPM Chlorine: Less than 1.5 PPM pH Factor: 7.0 - 8.5
Water which fails to meet these standards should be treated by installation of a water conditioner. Failure or malfunction of this steamer due to poor water quality is not cov-
ered under warranty.
WATER & DRAIN CONNECTIONS:
Drain 2” (51mm) IPS piped to open floor drain. No solid connection.
24” length before open air opening (no bends or elbows) Cold Water 3/8” (10mm) tubing at 25-50 PSI (170-345 kPa) Steam Take Off 3/4” IPS optional to operate adjacent equipment Appliance is to be installed with backflow protection in accordance with Federal, State or
Local codes.
GAS SUPPLY:
3/4" IPS supply line required
Minimum Inlet Pressure:
Natural 7.0" W.C. static to unit Propane 11.0" W.C. static to unit
POWER SUPPLY:
Unless otherwise specified, field wire electrical con­nection to be 120VAC, single phase, 60 Hz with grounding wire.
PRODUCT CLEARANCE
Right and Left side 3” (76mm) Rear 2” (51mm)
SHIPPING INFORMATION:
Approx. Weight:
CB24-140G 425 lbs. (193 kg) CB24-200G 425 lbs. (193 kg) CB36-140G 500 lbs. (227 kg) CB36-200G 525 lbs. (238 kg) CB36-250G 525 lbs. (238 kg) CB36-300G 525 lbs. (238 kg)
Printed in U.S.A. NOTE: FOR COMMERCIAL USE ONLY
NOTE: The company reserves the right to make substitutions of components without prior notice.
APPROVAL/STAMP
P/N S00027 Rev F (12/09)
MODEL A B C D E F G H J K L M
24” models 8.75[222] 5.75[146] 13.5[343] 24[610] 5.75[146] 3.5[89] 5[127] 11[279] 4.75[121] 2.5[64] 3[76] 12.5[318]
36” models 8.75[222] 5.75[146] 13.5[343] 24[610] 8[203] 3.5[89] 6[152] 11[279] 6.75[171] 2.5[64] 3[76] 6[152]