Blodgett BCP-61E-PT, BCP-62-62E Owner’s Manual

BCP & BLCP
COMBI OVENS
INSTALLATION - OPERATION - MAINTENANCE
BLODGETT OVEN COMPANY
www.blodgett.com
44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone: (802) 658-6600 Fax: (802)864-0183
PN 60739 Rev Q (9/14)
© 2014 - G.S. Blodgett Corporation
Model
Serial number
Oven installed by
Installation checked by
IMPORTANT
TABLE OF CONTENTS
WARNING: Improper installa­tion, adjustment, alternation, service or maintenance can cause property damage, in­jury or death. Read the instl­lation, operation and mainte­nance instructions thoroughly before installing or servicing this equipment.
INSTRUCTIONS TO BE FOL­LOWED IN THE EVENT THE USER SMELLS GAS MUST BE POSTED IN A PROMINENT LO­CATION. This information may be obtained by contacting your local gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors or liq­uids in the vicinity of this or any other appliance.
The information contained in this manual is important for the prop­er installation, use, and mainte­nance of this oven. Adherence to these procedures and instruc­tions will result in satisfactory baking results and long, trou­ble free service. Please read this manual carefully and retain it for future reference.
ERRORS: Descriptive, typo­graphic or pictorial errors are subject to correction. Speci­cations are subject to change without notice.
INSTALLATION
Utility Connections - Standards and Codes ................................. 2
The Blodgett Combi-Oven/Steamer ........................................ 3
Description of the Combi-Oven/Steamer ................................... 4
Utility Specications ...................................................... 5
Oven Assembly to Stand .................................................. 7
Oven Location and Leveling ............................................... 8
Plumbing Connections .................................................... 9
Electrical Connection and Ventilation ...................................... 11
Gas Connection......................................................... 12
Gas Hose Restraint ..................................................... 14
Final Check Lists ........................................................ 15
OPERATION
Safety Information for Gas Ovens ........................................ 16
Blodgett Programmable Control Introduction ............................... 17
Cooking Modes ......................................................... 18
Welcome Screen and Work Menu ........................................ 21
Manual Cooking ........................................................ 22
Core Probe Cooking ..................................................... 26
Programmed Cooking ................................................... 30
Programming a Product ................................................. 32
Setting a Timed Start .................................................... 37
Setting Preset Time & Temperature ....................................... 40
Oven Setup ............................................................ 41
USB Functions .......................................................... 43
HACCP Library ......................................................... 45
Optional CombiNet ...................................................... 47
MAINTENANCE
Cleaning & Preventative Maintenance..................................... 49
Deliming - BCP only ..................................................... 52
Installation
Utility Connections - Standards and Codes
THE INSTALLATION INSTRUCTIONS CONTAINED HEREIN ARE FOR THE USE OF QUALIFIED INSTAL­LATION AND SERVICE PERSONNEL ONLY. INSTAL­LATION OR SERVICE BY OTHER THAN QUALIFIED PERSONNEL MAY RESULT IN DAMAGE TO THE OVEN AND/OR INJURY TO THE OPERATOR.
Qualied installation personnel are individuals, a rm,
a corporation, or a company which either in person or through a representative are engaged in, and responsible for:
the installation or replacement of gas piping and the connection, installation, repair or servicing of equip-
ment.
the installation of electrical wiring from the electric meter, main control box or service outlet to the elec­tric appliance.
Qualied installation personnel must be experienced in such work, familiar with all precautions required, and have complied with all requirements of state or local authorities
having jurisdiction.
U.S. and Canadian installations
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1, as applicable.
Installation must conform with local codes, or in the ab­sence of local codes, with the National Electrical Code, ANSI/NFPA 70-Latest Edition and/or Canadian National Electric Code C22.1 as applicable.
Appliance is to be installed with backow prevention in
accordance with applicable federal, province and local codes.
Australia and general export installations
Instllation must conform with Local and National instal-
lation standards. Local installation codes and/or require­ments may vary. If you have any questions regarding the
proper installation and/or operation of your Blodgett oven, please contact your local distributor. If you do not have a local distributor, please call the Blodgett Oven Company at 0011-802-658-6600.
2
Installation
The Blodgett Combi-Oven/Steamer
The Blodgett Combi-Oven/Steamer offers a completely new method of cooking. With the Oven/Steamer you have the choice of two cooking processes: Steam and Hot Air, either...
Separately
Combined, or
In Sequence
And for easy operation you can choose from three modes:
In the Steam mode you can:
steam reheat reconstitute stew thaw simmer blanche preserve braise poach
In the Hot Air mode you can:
roast bake grill gratinate broil
In the Combination Steam and Hot Air mode you can:
defrost roast rethermalize reheat bake forced steam
There are four additional specialized modes to help you make the most of your time:
Retherm - for perfect reheating
Proong - Proof and bake all in the same oven
Preheat - in this mode the oven will preheat to 575ºF (300ºC) for 15 minutes. The oven will then automatically lower to 480ºF (249ºC) to protect the advanced elec­tronic components.
Cool Down - allows the oven cavity to cool down rapidly with the door opened
You can also use two or three functions in se-
quence during one cooking process. We call this:
combi-steaming
combi-roasting
combi-baking
The combination of circulating hot air and steam in the space saving, high performance Combi-Oven/Steamer leads to improvements in the following areas:
increased productivity in the kitchen
a reduction in capital expenditures for multiple equip-
ment replacement
a wider range of menu choices
a simplied cleaning process
The work process is simplied since products are pre-
pared on or in steam table pans and trays. Food can be cooked, stored, and transported with the same pans.
Small amounts of product can be processed efciently;
pre-cooked and convenience foods can be reheated with­in minutes. Many frozen foods can be processed with-
out pre-thawing. This exibility in preparation reduces the
need for kettles and steam tables since there is no need for large amounts of food to be kept warm for long periods of time.
Today the improvement of food quality is more important
than ever. Vegetables are cooked in the Blodgett Combi­Oven/Steamer without water at the optimal temperature of just under 212ºF (100ºC), maintaining valuable vita­mins, minerals, nutrients and trace elements. Cooking
meat in the Combi results in less shrinkage and a rmer,
juicier product. The Blodgett Combi-Oven/Steamer is be­ing used more and more for baking. Steam and Hot Air modes make it a general purpose baking appliance.
3
Installation
Description of the Combi-Oven/Steamer
ABOUT THE OVEN/STEAMER
Blodgett Combi-Oven/Steamers are quality produced us­ing high-grade stainless steel with rst class workman-
ship.
The multiple speed fan, which is guarded against acci-
dental nger contact, is driven by a quiet and powerful
motor. The condenser draws out excess steam from the appliance. Condensation and waste water, which result during steaming and cleaning, are continuously drained.
The use of high quality insulation impedes excessive heat
radiation and saves energy.
The BCP/BLCP makes it possible to enjoy all of the ad-
vantages of a high quality steamer at the ick of a switch.
Fresh steam enters the oven cavity without pressure and
is circulated at high speed. This process enables quick and gentle cooking and ensures high quality food while
providing convenient working methods. The steam gen­erator is completely automatic and protected from running dry.
OVEN/STEAMER OPERATION
The practical oven door, with a viewing window, has a wide swing radius and handle which can be operated eas­ily, even with wet or greasy hands.
Ease of operation is guaranteed through the simple to use touchscreen control. With graphical symbols and storage for 199 product recipes the BCP/BLCP is easy for even inexperienced kitchen staff to operate.
Cleaning is kept to a minimum thanks to the automatic Combi Wash system.
4
PLUMBING SPECIFICATIONS
WATER
Water pressure 36.26 PSI (250 kPa, 2.5 bar) during Combi Wash
21.76 PSI (150 kPa, 1.5 bar) when Combi Wash is not active
40(min)-50(max) PSI supply pressure Water connection 3/4” garden hose cold water Water quality requirements TDS: 40-125 ppm
Hardness: 35-100 ppm
Chlorides: <25 ppm
Silica: <13 ppm
Chlorine: 0 ppm
pH: 7.0-8.5
DRAINAGE
Drain type Atmospheric Vented Drain Drain connection 2.00” (50.8mm) Copper Maximum water drain temperature 140ºF (60ºC)
Installation
Utility Specications
RATINGS - GAS OVENS
Model Gas Type Input Voltage Phase Amps
BLCP-61G Natural 58,000 BTU 115 1 9
Propane 58,000 BTU 11 5 1 9
BLCP-101G Natural 87,000 BTU 115 1 9
Propane 87,000 BTU 11 5 1 9
BLCP-102G Natural 95,500 BTU 115 1 9
Propane 95,500 BTU 11 5 1 9
BLCP-202G Natural 190,000 BTU 115 1 17
Propane 190,000 BTU 115 1 17
5
Installation
Utility Specications
Model Voltage kW Hz Phase Max Load (amps)
208/230/240
BLCP-23E
Mini Combi
BLCP-6E
Mini Combi
BLCP-10E
Mini Combi
BCP-61E
BLCP-61E
BCP-101E
BLCP-101E
BCP-102E
BLCP-102E
BCP-202E
BLCP-202E
400/415
440/480 5.4/6.5 50/60 2AC 15
208 4.6 50/60 1 23 240 6.1 50/60 1 26 208 6.9 50/60 3 20 240 9.2 50/60 3 23
208/230/240
400/415
440/480 10.4/12.4 50/60 3AC 18
208 9 60 3 25 240 9 60 3 22 480 9 60 3 11 208 18 60 3 50 240 18 60 3 44 480 18 60 3 22 208 27 60 3 75 240 27 60 3 65 480 27 60 3 33 208 60 60 3 167 240 60 60 3 145 480 60 60 3 73
ELECTRICAL RATINGS
2.7/3.3/3.6 50/60 1NAC 15
2.7/3.3/3.6 50/60 2AC 15
5.4/6.6/7.2 50/60 3AC 30
6.6/7.2 50/60 2NAC 15
5.4/5.8 50/60 2AC 15
10.4/12.7/13.8 50/60 3AC 34
10.4/12.7/13.8 50/60 3NAC 34
12.7/13.8 50/60 3NAC 20
12.7/13.8 50/60 3AC 20
6
Your Blodgett COMBI oven has been shipped with black plastic caps on the corners of its base. In order to mount your oven to its stand, please do the following:
1. Remove the stand from the packaging. Install the casters or feet into the base of the stand. If inserting casters ensure that the locking casters are at the front
of the stand, see gure. Place the stand upright in an
area readily available.
2. Remove all packaging from the oven, so that the oven can be picked up.
3. Remove the black plastic caps on each corner by removing the two screws holding them on. Do NOT
discard these screws; they will be used to mount the
oven to the stand.
4. Position the oven over the stand and align the corner brackets on the stand with the holes on the oven.
5. Use the screws from the plastics caps to mount the oven to the stand.
Installation
Oven Assembly to Stand
Note difference in rail placement
Front of stand
6. The oven has now been properly fastened to the stand.
Figure 1
7
Installation
Oven Location and Leveling
The well planned and proper placement of your oven will result in long term operator convenience and satisfactory performance.
Certain minimum clearances must be maintained be­tween the oven and any combustible or non-combustible construction.
MINIMUM REQUIRED CLEARANCES
Size Left Right Back
Electric Ovens
61, 101,
102 & 202
Gas Ovens
61, 101,
102 & 202
2.75”
(70mm)
2.75”
(70mm)
2.75”
(70mm)
2.75”
(70mm)
2”
(50mm)
2”
(50mm)
Strong sources of heat such as hotplates, tilting frying pans, deep fat fryers, etc. should not be placed near the oven, especially near its right side. An optional side heat shield is available.
In addition, the following clearances are recommended for servicing.
Oven body sides - 12” (30cm)
Oven body back - 12” (30cm)
To ensure that the oven functions correctly when installed, it should be placed upright and level (horizontally). This is measured at the front and side edge of the roof. The oven can be levelled using the adjusting screws on the stand or on the legs of table models. The height of the oven should
also be adjusted to t the trolley for rack.
Correct Installation Incorrect Installation
Figure 2
8
Installation
Plumbing Connections
WATER CONNECTION
Blodgett BCP/BLCP ovens have two water connections. Both are located at the back of the unit.
BCP/BLCP-61, 101, 102 and 202 models
1 connection for raw water for the condensation jet.
1 connection for steam generation and the Combi
Wash jet in the oven chamber. Must meet the re-
quirements applying to water supplied to household
appliances.
Quench
Steam
Figure 3
To facilitate cleaning and servicing, the oven should be
connected with an approved exible 3/4” hose. Perma­nent installations should be tted with a stop-tap and a
non-return valve.
Before connecting the oven to water, ush the tubes
thoroughly. Connect the oven.
DRAIN CONNECTION
Blodgett ovens are equipped with a drain system that re­moves surplus water from the oven chamber. This may be condensed water from the products, or it may occur when the oven chamber is cooled down with cold water, or when the oven chamber is cleaned.
WARNING!!
Connection must be carried out by an autho­rised plumber, to an open or closed drain. The drain must never end directly beneath the oven.
The drain must be of stainless steel or an equally tem­perature-resistant material, have a diameter of at least 2” (49 mm) and a fall of at least 3° or 5%.
BLCP-23, 6 and 10 Mini Combi models
1 water connection. Must meet the requirements ap­plying to water supplied to household appliances.
Water connection
Figure 4
WARNING!!
If the water temperature exceeds 70°F (21°C), problems with regard to Combi Optima cali­bration and cooling of the oven may occur.
The water connection must be carried out by an authorized plumber in accordance with existing local codes.
Clogged up water lters and dirt in the sole­noid valves are not covered by the warranty.
9
Installation
Plumbing Connections
CLEANING & DELIMING CHEMICAL
1. BCP/BLCP-61, 101, 102 and 202 ovens only. The oven is supplied with a chemical bottle holder. The
holder can be afxed to either side of the oven. Place
it on the stand crossmember.
Figure 5
2. Connect the supplied detergent tubes (red and blue) to the underside of the oven near the rear. Connect
the blue hose to the tting with the blue sticker and the red hose to the tting with the red sticker.
3. Insert the blue and red hoses into the proper bottles. Red is for detergent, blue is for rinse aid.
4. BCP only - The last line is for the delimer. This is the tan colored tube protroding from the bottom of the oven. Cut the tubing to the proper length, if needed, and place the tubing into the delime bottle.
NOTE: If the tube is cut to length, remove the stain-
less steel weight from the end of the tube and reinsert.
Blue Sticker
Red Sticker
Red Tube
Blue Tube
Figure 6
10
ELECTRICAL CONNECTION
NOTE: Electrical connections must be performed by a
qualied installer only.
Before making any electrical connections to these appli-
ances, check that the power supply is adequate for the voltage, amperage, and phase requirements stated on
the rating name plate mounted on the appliance.
1. The rating plate is located on the right side of the oven.
An approved plug outlet or a safety cutout must be locat­ed close to the oven so that the oven can be disconnected during installation and repair. The safety cutout must be able to cut off all poles with a total distance of break of at least 3 mm.
All appliances must be installed in accordance with Local or National Electrical codes.
The wiring diagram is located in the motor compartment.
NOTE: Disconnect the power supply to the appliance
before servicing.
WARNING!!
Improper installation may invalidate your war­ranty.
Electric Models
A strain relief for the power supply cord is provided. The installer must supply a cord that meets all Local and Na­tional installation standards.
Gas Models
U.S. and Canadian Installations
A power cord (115V units only) is supplied with a plug at­tached. Plug the power cord into the desired receptacle.
NOTE: The BLCP-202G must be hard wired.
This oven model uses a variable frequency inverter drive. Appliances that use variable frequency inverter drives produce high frequency noise and require lters and
shielded motor cabling. This causes higher leakage cur­rent toward Earth Ground. Especially, at the moment of switching ON this can cause an inadvertent trip of the ap­pliance’s ground fault interrupter (GFCI). Some GFCIs
are more sensitive than others. Blodgett has qualied the
Pass and Seymour brand, part number 2095, 20 A, 125
VAC, 60 Hz, specication grade GFCI duplex receptacle as being immune to the variable frequency inverter drive’s noise. Blodgett recommends using this specic GFCI for
this model oven.
Installation
Electrical Connection and Ventilation
WARNING!!
If the supply cord is damaged, it must be re­placed by a special cord or assembly available from the manufacturer or its service agent.
VENTILATION
Blodgett BCP/BLCP ovens are equipped with an open/
direct exhaust system that removes surplus humidity from the oven chamber. The exhaust system has an electrically operated damper.
The ventilation motor can be controlled directly from the oven. This means that the ventilation starts when a pro­gram is started and runs for 10 minutes after the program is completed.
The exhaust tube can be connected to a ventilation sys-
tem. In that case, a special extraction funnel is tted to
avoid suction directly from the oven chamber. This extrac­tion funnel can be ordered from Blodgett.
If an extraction hood is installed in the ceiling above the oven, it should project 20” (50 cm) over the front of the oven.
Figure 7
11
Installation
Gas Connection
GAS PIPING
A properly sized gas supply system is essential for maxi­mum oven performance. Piping should be sized to pro­vide a supply of gas sufcient to meet the maximum de­mand of all appliances on the line without loss of pressure
at the equipment.
Example:
NOTE: BTU values in the following example are for
natural gas.
You purchase a BLCP-61G to add to your existing cook line.
1. Add the BTU rating of your current appliances.
Pitco Fryer 120,000 BTU
6 Burner Range 60,000 BTU
Deck Oven 50,000 BTU
Total 230,000 BTU
2. Add the BTU rating of the new oven to the total.
Previous Total 230,000 BTU
BLCP-61G 40,900 BTU
New Total 270,900 BTU
3. Measure the distance from the gas meter to the cook line. This is the pipe length. Let’s say the pipe length is 40’ (12.2 m) and the pipe size is 1” (2.54 cm).
4. Use the appropriate table to determine the total ca­pacity of your current gas piping.
The total capacity for this example is 375,00 BTU. Since
the total required gas pressure, 270,900 BTU is less than
375,000 BTU, the current gas piping will not have to be increased.
NOTE: The BTU capacities given in the tables are for
straight pipe lengths only. Any elbows or other
ttings will decrease pipe capacities. Contact
your local gas supplier if you have any ques­tions.
Maximum Capacity of Iron Pipe in Cubic Feet of
Natural Gas Per Hour
(Pressure drop of 0.5 Inch W.C.)
PIPE
LENGTH (FT)
10 360 680 1400 2100 3950 20 250 465 950 1460 2750 30 200 375 770 1180 2200 40 170 320 660 990 1900 50 151 285 580 900 1680 60 138 260 530 810 1520 70 125 240 490 750 1400 80 118 220 460 690 1300 90 110 205 430 650 1220
100 103 195 400 620 1150
From the National Fuel Gas Code Part 10 Table 10-2
Maximum Capacity of Pipe in Thousands of
BTU/hr of Undiluted L.P. Gas at 11” W.C.
(Pressure drop of 0.5 Inch W.C.)
PIPE
LENGTH (FT)
10 608 1146 3525 20 418 788 2423 30 336 632 1946 40 287 541 1665 50 255 480 1476 60 231 435 1337 70 215 404 1241 80 198 372 1144 90 187 351 1079
100 175 330 1014
From the National Fuel Gas Code Part 10 Table 10-15
NOMINAL SIZE, INCHES
3/4” 1” 1-1/4” 1-1/2” 2”
OUTSIDE DIAMETER, INCHES
3/4” 1” 1-1/2”
12
PRESSURE REGULATION AND TESTING
The gas pressure to the appliance must be rated for each appliance while the burners are on. A sufcient gas pres­sure must be present at the inlet to satisfy these condi­tions. Refer to the table below for correct gas pressure.
Each appliance has been adjusted at the factory to oper-
ate with the type of gas specied on the rating plate.
Each oven is supplied with a regulator to maintain the proper gas pressure. The regulator is essential to the
proper operation of the oven and should not be re­moved.
DO NOT INSTALL AN ADDITIONAL REGULATOR WHERE THE UNIT CONNECTS TO THE GAS SUPPLY UNLESS THE INLET PRESSURE IS GREATER THAN 14” W.C. (1/2 PSI) (37mbar).
The oven and its individual shutoff valve must be discon­nected from the gas supply piping system during any pressure testing of that system at test pressures in ex­cess of 1/2 psig (3.45kPa).
The oven must be isolated from the gas supply piping system by closing its individual manual shutoff valve dur­ing any pressure testing of the gas piping system at test
pressures equal or less than 1/2 psig (3.45kPa).
Installation
Gas Connections
Prior to connecting the appliance, gas lines should be
thoroughly purged of all metal lings, shavings, pipe
dope, and other debris. After connection, the appliance must be checked for correct gas pressure.
U.S. and Canadian Installations
Installation must conform with local codes, or in the ab­sence of local codes, with the National Fuel Gas Code, NFPA54/ANSI Z223.1-Latest Edition, the Natural Gas In­stallation Code CAN/CGA-B149.1 or the Propane Instal­lation Code, CAN/CGA-B149.2 as applicable.
General Export Installations
Installation must conform with Local and National instal-
lation standards. Local installation codes and/or require­ments may vary. If you have any questions regarding the
proper installation and/or operation of your appliance, please contact your local distributor. If you do not have a local distributor, please call Blodgett Combi at 0011-802­658-6600.
GAS PRESSURE
Model Gas Type Inlet Pressure
BLCP-61G Natural 3.2-8.0” W.C.
Propane 5.2-14” W.C.
BLCP-101G Natural 3.2-8.0” W.C.
Propane 5.2-14” W.C.
BLCP-102G Natural 3.2-8.0” W.C.
Propane 5.2-14” W.C.
BLCP-202G Natural 3.2-8.0” W.C.
Propane 5.2-14” W.C.
13
Installation
Gas Hose Restraint
If the appliance is mounted on casters, a commercial ex­ible connector with a minimum of 3/4” (1.9 cm) inside di-
ameter must be used along with a quick connect device.
A restraint must be used to limit the movement of the ap­pliance so that no strain is placed upon the exible con­nector. The restraint should be fastened to the base frame
of the oven as close to the exible connector as possible.
It should be short enough to prevent any strain on the connector. With the restraint fully stretched the connector
should be easy to install and quick connect.
The restraint (ie: heavy gauge cable) should be attached without damaging the building. DO NOT use the gas pip­ing or electrical conduit for the attachment of the perma­nent end of the restraint! Use anchor bolts in concrete or cement block. On wooden walls, drive hi test wood lag screws into the studs of the wall.
WARNING!!
If the restraint is disconnected for any reason it must be reconnected when the appliance is returned to its original position.
U.S. and Canadian installations
The connector must comply with the Standard for Con­nectors for Movable Gas Appliances, ANSI Z21.69 or Connectors For Moveable Gas Appliances CAN/CGA-
6.16 and a quick disconnect device that complies with the
Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41 or Quick Disconnect For Use With Gas
Fuel CAN 1-6.9. Adequate means must be provided to
limit the movement of the appliance without depending
on the connection and the quick disconnect device or its
associated piping.
A drip leg must be used at each appliance. Refer to NFPA54/ANSI Z223.1 - Latest Edition (National Fuel Gas Code) for proper drip leg installation.
General export installations
Installation must conform with Local and National instal-
lation standards. Local installation codes and/or require­ments may vary. If you have any questions regarding the
proper installation and/or operation of your appliance, please contact your local distributor. If you do not have a local distributor, please call Blodgett Combi at 0011-802­658-6600.
Attachment Plate (secure with leg mount bolt)
Quick Connect
Gas Hose
Restraint
Installation of Gas Hose and Restraint
(Single Section Shown)
Figure 8
Gas Supply Line
IMPORTANT: Cable restraint should be fastened as close as possible
to the exible connector and short
enough to prevent any strain on the
exible connector.
At maximum stretch of shortened
restraint, the exible connector should be easy to install and quick
to connect.
14
WARNING!!
Final check list must be performed by a quali-
ed installer only.
OVEN EXTERIOR
1. Check that the oven has not been damaged in transit (dents, scratches, etc.)
2. Check/adjust the height and check that the oven is placed level (horizontally)
3. Check/adjust oven door
CONNECTIONS
1. Check for correct water connection
2. Turn on water supply
3. Check for leaks
4. Turn off water supply
Installation
Final Check Lists
OVEN INTERIOR
1. Check that lter housing is mounted correctly
2. Check interior light
3. Clean the oven
CONTROL
1. Check and adjust, if necessary, each of the preset values
2. Heat up the oven at 480°F (249°C) for approximately 5 minutes.
5. Check and clean dirt lter
6. Turn on water supply again
7. Check hand shower
8. Check for correct electrical connection
9. Check for correct gas connection (if applicable)
10. Check connection to drip tray
11. Check for correct mounting of drip tray
12. Check for correct fall of hose from drip tray, and check for leaks
13. Check for correct exhaust and drain connection
14. Clean the oven
15. Apply steel oil
15
Loading...
+ 37 hidden pages