WARNING: Improper installation, adjustment, alternation,
service or maintenance can
cause property damage, injury or death. Read the instllation, operation and maintenance instructions thoroughly
before installing or servicing
this equipment.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE
USER SMELLS GAS MUST BE
POSTED IN A PROMINENT LOCATION. This information may
be obtained by contacting your
local gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or
other ammable vapors or liquids in the vicinity of this or any
other appliance.
The information contained in this
manual is important for the proper installation, use, and maintenance of this oven. Adherence
to these procedures and instructions will result in satisfactory
baking results and long, trouble free service. Please read
this manual carefully and retain
it for future reference.
ERRORS: Descriptive, typographic or pictorial errors are
subject to correction. Specications are subject to change
without notice.
INSTALLATION
Utility Connections - Standards and Codes ................................. 2
The Blodgett Combi-Oven/Steamer ........................................ 3
Description of the Combi-Oven/Steamer ................................... 4
Deliming - BCP only ..................................................... 52
Installation
Utility Connections - Standards and Codes
THE INSTALLATION INSTRUCTIONS CONTAINED
HEREIN ARE FOR THE USE OF QUALIFIED INSTALLATION AND SERVICE PERSONNEL ONLY. INSTALLATION OR SERVICE BY OTHER THAN QUALIFIED
PERSONNEL MAY RESULT IN DAMAGE TO THE OVEN
AND/OR INJURY TO THE OPERATOR.
Qualied installation personnel are individuals, a rm,
a corporation, or a company which either in person or
through a representative are engaged in, and responsible
for:
• the installation or replacement of gas piping and the
connection, installation, repair or servicing of equip-
ment.
• the installation of electrical wiring from the electric
meter, main control box or service outlet to the electric appliance.
Qualied installation personnel must be experienced in
such work, familiar with all precautions required, and have
complied with all requirements of state or local authorities
having jurisdiction.
U.S. and Canadian installations
The installation must conform with local codes, or in the
absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54, or the Natural Gas and Propane
Installation Code, CSA B149.1, as applicable.
Installation must conform with local codes, or in the absence of local codes, with the National Electrical Code,
ANSI/NFPA 70-Latest Edition and/or Canadian National
Electric Code C22.1 as applicable.
Appliance is to be installed with backow prevention in
accordance with applicable federal, province and local
codes.
Australia and general export installations
Instllation must conform with Local and National instal-
lation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the
proper installation and/or operation of your Blodgett oven,
please contact your local distributor. If you do not have a
local distributor, please call the Blodgett Oven Company
at 0011-802-658-6600.
2
Installation
The Blodgett Combi-Oven/Steamer
The Blodgett Combi-Oven/Steamer offers a completely
new method of cooking. With the Oven/Steamer you have
the choice of two cooking processes: Steam and Hot Air,
either...
• Separately
• Combined, or
• In Sequence
And for easy operation you can choose from three modes:
There are four additional specialized modes to help you
make the most of your time:
Retherm - for perfect reheating
Proong - Proof and bake all in the same oven
Preheat - in this mode the oven will preheat to 575ºF
(300ºC) for 15 minutes. The oven will then automatically
lower to 480ºF (249ºC) to protect the advanced electronic components.
Cool Down - allows the oven cavity to cool down rapidly
with the door opened
You can also use two or three functions in se-
quence during one cooking process. We call this:
• combi-steaming
• combi-roasting
• combi-baking
The combination of circulating hot air and steam in the
space saving, high performance Combi-Oven/Steamer
leads to improvements in the following areas:
• increased productivity in the kitchen
• a reduction in capital expenditures for multiple equip-
ment replacement
• a wider range of menu choices
• a simplied cleaning process
The work process is simplied since products are pre-
pared on or in steam table pans and trays. Food can be
cooked, stored, and transported with the same pans.
Small amounts of product can be processed efciently;
pre-cooked and convenience foods can be reheated within minutes. Many frozen foods can be processed with-
out pre-thawing. This exibility in preparation reduces the
need for kettles and steam tables since there is no need
for large amounts of food to be kept warm for long periods
of time.
Today the improvement of food quality is more important
than ever. Vegetables are cooked in the Blodgett CombiOven/Steamer without water at the optimal temperature
of just under 212ºF (100ºC), maintaining valuable vitamins, minerals, nutrients and trace elements. Cooking
meat in the Combi results in less shrinkage and a rmer,
juicier product. The Blodgett Combi-Oven/Steamer is being used more and more for baking. Steam and Hot Air
modes make it a general purpose baking appliance.
3
Installation
Description of the Combi-Oven/Steamer
ABOUT THE OVEN/STEAMER
Blodgett Combi-Oven/Steamers are quality produced using high-grade stainless steel with rst class workman-
ship.
The multiple speed fan, which is guarded against acci-
dental nger contact, is driven by a quiet and powerful
motor. The condenser draws out excess steam from the
appliance. Condensation and waste water, which result
during steaming and cleaning, are continuously drained.
The use of high quality insulation impedes excessive heat
radiation and saves energy.
The BCP/BLCP makes it possible to enjoy all of the ad-
vantages of a high quality steamer at the ick of a switch.
Fresh steam enters the oven cavity without pressure and
is circulated at high speed. This process enables quick
and gentle cooking and ensures high quality food while
providing convenient working methods. The steam generator is completely automatic and protected from running
dry.
OVEN/STEAMER OPERATION
The practical oven door, with a viewing window, has a
wide swing radius and handle which can be operated easily, even with wet or greasy hands.
Ease of operation is guaranteed through the simple to use
touchscreen control. With graphical symbols and storage
for 199 product recipes the BCP/BLCP is easy for even
inexperienced kitchen staff to operate.
Cleaning is kept to a minimum thanks to the automatic
Combi Wash system.
4
PLUMBING SPECIFICATIONS
WATER
Water pressure36.26 PSI (250 kPa, 2.5 bar) during Combi Wash
21.76 PSI (150 kPa, 1.5 bar) when Combi Wash is not active
40(min)-50(max) PSI supply pressure
Water connection3/4” garden hose cold water
Water quality requirementsTDS: 40-125 ppm
Hardness: 35-100 ppm
Chlorides: <25 ppm
Silica: <13 ppm
Chlorine: 0 ppm
pH: 7.0-8.5
DRAINAGE
Drain typeAtmospheric Vented Drain
Drain connection2.00” (50.8mm) Copper
Maximum water drain temperature140ºF (60ºC)
Your Blodgett COMBI oven has been shipped with black
plastic caps on the corners of its base. In order to mount
your oven to its stand, please do the following:
1. Remove the stand from the packaging. Install the
casters or feet into the base of the stand. If inserting
casters ensure that the locking casters are at the front
of the stand, see gure. Place the stand upright in an
area readily available.
2. Remove all packaging from the oven, so that the oven
can be picked up.
3. Remove the black plastic caps on each corner by
removing the two screws holding them on. Do NOT
discard these screws; they will be used to mount the
oven to the stand.
4. Position the oven over the stand and align the corner
brackets on the stand with the holes on the oven.
5. Use the screws from the plastics caps to mount the
oven to the stand.
Installation
Oven Assembly to Stand
Note difference in rail
placement
Front of stand
6. The oven has now been properly fastened to the
stand.
Figure 1
7
Installation
Oven Location and Leveling
The well planned and proper placement of your oven will
result in long term operator convenience and satisfactory
performance.
Certain minimum clearances must be maintained between the oven and any combustible or non-combustible
construction.
MINIMUM REQUIRED CLEARANCES
SizeLeftRightBack
Electric Ovens
61, 101,
102 & 202
Gas Ovens
61, 101,
102 & 202
2.75”
(70mm)
2.75”
(70mm)
2.75”
(70mm)
2.75”
(70mm)
2”
(50mm)
2”
(50mm)
Strong sources of heat such as hotplates, tilting frying
pans, deep fat fryers, etc. should not be placed near the
oven, especially near its right side. An optional side heat
shield is available.
In addition, the following clearances are recommended
for servicing.
• Oven body sides - 12” (30cm)
• Oven body back - 12” (30cm)
To ensure that the oven functions correctly when installed,
it should be placed upright and level (horizontally). This is
measured at the front and side edge of the roof. The oven
can be levelled using the adjusting screws on the stand or
on the legs of table models. The height of the oven should
also be adjusted to t the trolley for rack.
Correct InstallationIncorrect Installation
Figure 2
8
Installation
Plumbing Connections
WATER CONNECTION
Blodgett BCP/BLCP ovens have two water connections.
Both are located at the back of the unit.
BCP/BLCP-61, 101, 102 and 202 models
• 1 connection for raw water for the condensation jet.
• 1 connection for steam generation and the Combi
Wash jet in the oven chamber. Must meet the re-
quirements applying to water supplied to household
appliances.
Quench
Steam
Figure 3
To facilitate cleaning and servicing, the oven should be
connected with an approved exible 3/4” hose. Permanent installations should be tted with a stop-tap and a
non-return valve.
Before connecting the oven to water, ush the tubes
thoroughly. Connect the oven.
DRAIN CONNECTION
Blodgett ovens are equipped with a drain system that removes surplus water from the oven chamber. This may
be condensed water from the products, or it may occur
when the oven chamber is cooled down with cold water,
or when the oven chamber is cleaned.
WARNING!!
Connection must be carried out by an authorised plumber, to an open or closed drain.
The drain must never end directly beneath the
oven.
The drain must be of stainless steel or an equally temperature-resistant material, have a diameter of at least 2”
(49 mm) and a fall of at least 3° or 5%.
BLCP-23, 6 and 10 Mini Combi models
• 1 water connection. Must meet the requirements applying to water supplied to household appliances.
Water
connection
Figure 4
WARNING!!
If the water temperature exceeds 70°F (21°C),
problems with regard to Combi Optima calibration and cooling of the oven may occur.
The water connection must be carried out by
an authorized plumber in accordance with
existing local codes.
Clogged up water lters and dirt in the solenoid valves are not covered by the warranty.
9
Installation
Plumbing Connections
CLEANING & DELIMING CHEMICAL
1. BCP/BLCP-61, 101, 102 and 202 ovens only. The
oven is supplied with a chemical bottle holder. The
holder can be afxed to either side of the oven. Place
it on the stand crossmember.
Figure 5
2. Connect the supplied detergent tubes (red and blue)
to the underside of the oven near the rear. Connect
the blue hose to the tting with the blue sticker and
the red hose to the tting with the red sticker.
3. Insert the blue and red hoses into the proper bottles.
Red is for detergent, blue is for rinse aid.
4. BCP only - The last line is for the delimer. This is the
tan colored tube protroding from the bottom of the
oven. Cut the tubing to the proper length, if needed,
and place the tubing into the delime bottle.
NOTE: If the tube is cut to length, remove the stain-
less steel weight from the end of the tube
and reinsert.
Blue Sticker
Red Sticker
Red Tube
Blue Tube
Figure 6
10
ELECTRICAL CONNECTION
NOTE: Electrical connections must be performed by a
qualied installer only.
Before making any electrical connections to these appli-
ances, check that the power supply is adequate for the
voltage, amperage, and phase requirements stated on
the rating name plate mounted on the appliance.
1. The rating plate is located on the right side of the
oven.
An approved plug outlet or a safety cutout must be located close to the oven so that the oven can be disconnected
during installation and repair. The safety cutout must be
able to cut off all poles with a total distance of break of at
least 3 mm.
All appliances must be installed in accordance with Local
or National Electrical codes.
The wiring diagram is located in the motor compartment.
NOTE: Disconnect the power supply to the appliance
before servicing.
WARNING!!
Improper installation may invalidate your warranty.
Electric Models
A strain relief for the power supply cord is provided. The
installer must supply a cord that meets all Local and National installation standards.
Gas Models
U.S. and Canadian Installations
A power cord (115V units only) is supplied with a plug attached. Plug the power cord into the desired receptacle.
NOTE: The BLCP-202G must be hard wired.
This oven model uses a variable frequency inverter drive.
Appliances that use variable frequency inverter drives
produce high frequency noise and require lters and
shielded motor cabling. This causes higher leakage current toward Earth Ground. Especially, at the moment of
switching ON this can cause an inadvertent trip of the appliance’s ground fault interrupter (GFCI). Some GFCIs
are more sensitive than others. Blodgett has qualied the
Pass and Seymour brand, part number 2095, 20 A, 125
VAC, 60 Hz, specication grade GFCI duplex receptacle
as being immune to the variable frequency inverter drive’s
noise. Blodgett recommends using this specic GFCI for
this model oven.
Installation
Electrical Connection and Ventilation
WARNING!!
If the supply cord is damaged, it must be replaced by a special cord or assembly available
from the manufacturer or its service agent.
VENTILATION
Blodgett BCP/BLCP ovens are equipped with an open/
direct exhaust system that removes surplus humidity from
the oven chamber. The exhaust system has an electrically
operated damper.
The ventilation motor can be controlled directly from the
oven. This means that the ventilation starts when a program is started and runs for 10 minutes after the program
is completed.
The exhaust tube can be connected to a ventilation sys-
tem. In that case, a special extraction funnel is tted to
avoid suction directly from the oven chamber. This extraction funnel can be ordered from Blodgett.
If an extraction hood is installed in the ceiling above the
oven, it should project 20” (50 cm) over the front of the
oven.
Figure 7
11
Installation
Gas Connection
GAS PIPING
A properly sized gas supply system is essential for maximum oven performance. Piping should be sized to provide a supply of gas sufcient to meet the maximum demand of all appliances on the line without loss of pressure
at the equipment.
Example:
NOTE: BTU values in the following example are for
natural gas.
You purchase a BLCP-61Gto add to your existing cook
line.
1. Add the BTU rating of your current appliances.
Pitco Fryer 120,000 BTU
6 Burner Range 60,000 BTU
Deck Oven 50,000 BTU
Total 230,000 BTU
2. Add the BTU rating of the new oven to the total.
Previous Total 230,000 BTU
BLCP-61G 40,900 BTU
New Total 270,900 BTU
3. Measure the distance from the gas meter to the cook
line. This is the pipe length. Let’s say the pipe length
is 40’ (12.2 m) and the pipe size is 1” (2.54 cm).
4. Use the appropriate table to determine the total capacity of your current gas piping.
The total capacity for this example is 375,00 BTU. Since
the total required gas pressure, 270,900 BTU is less than
375,000 BTU, the current gas piping will not have to be
increased.
NOTE: The BTU capacities given in the tables are for
straight pipe lengths only. Any elbows or other
ttings will decrease pipe capacities. Contact
your local gas supplier if you have any questions.
From the National Fuel Gas Code Part 10 Table 10-15
NOMINAL SIZE, INCHES
3/4”1”1-1/4” 1-1/2”2”
OUTSIDE DIAMETER, INCHES
3/4”1”1-1/2”
12
PRESSURE REGULATION AND TESTING
The gas pressure to the appliance must be rated for each
appliance while the burners are on. A sufcient gas pressure must be present at the inlet to satisfy these conditions. Refer to the table below for correct gas pressure.
Each appliance has been adjusted at the factory to oper-
ate with the type of gas specied on the rating plate.
Each oven is supplied with a regulator to maintain the
proper gas pressure. The regulator is essential to the
proper operation of the oven and should not be removed.
DO NOT INSTALL AN ADDITIONAL REGULATOR
WHERE THE UNIT CONNECTS TO THE GAS SUPPLY
UNLESS THE INLET PRESSURE IS GREATER THAN
14” W.C. (1/2 PSI) (37mbar).
The oven and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psig (3.45kPa).
The oven must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during any pressure testing of the gas piping system at test
pressures equal or less than 1/2 psig (3.45kPa).
Installation
Gas Connections
Prior to connecting the appliance, gas lines should be
thoroughly purged of all metal lings, shavings, pipe
dope, and other debris. After connection, the appliance
must be checked for correct gas pressure.
U.S. and Canadian Installations
Installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code,
NFPA54/ANSI Z223.1-Latest Edition, the Natural Gas Installation Code CAN/CGA-B149.1 or the Propane Installation Code, CAN/CGA-B149.2 as applicable.
General Export Installations
Installation must conform with Local and National instal-
lation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the
proper installation and/or operation of your appliance,
please contact your local distributor. If you do not have a
local distributor, please call Blodgett Combi at 0011-802658-6600.
GAS PRESSURE
ModelGas TypeInlet Pressure
BLCP-61GNatural3.2-8.0” W.C.
Propane5.2-14” W.C.
BLCP-101GNatural3.2-8.0” W.C.
Propane5.2-14” W.C.
BLCP-102GNatural3.2-8.0” W.C.
Propane5.2-14” W.C.
BLCP-202GNatural3.2-8.0” W.C.
Propane5.2-14” W.C.
13
Installation
Gas Hose Restraint
If the appliance is mounted on casters, a commercial exible connector with a minimum of 3/4” (1.9 cm) inside di-
ameter must be used along with a quick connect device.
A restraint must be used to limit the movement of the appliance so that no strain is placed upon the exible connector. The restraint should be fastened to the base frame
of the oven as close to the exible connector as possible.
It should be short enough to prevent any strain on the
connector. With the restraint fully stretched the connector
should be easy to install and quick connect.
The restraint (ie: heavy gauge cable) should be attached
without damaging the building. DO NOT use the gas piping or electrical conduit for the attachment of the permanent end of the restraint! Use anchor bolts in concrete or
cement block. On wooden walls, drive hi test wood lag
screws into the studs of the wall.
WARNING!!
If the restraint is disconnected for any reason
it must be reconnected when the appliance is
returned to its original position.
U.S. and Canadian installations
The connector must comply with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or
Connectors For Moveable Gas Appliances CAN/CGA-
6.16 and a quick disconnect device that complies with the
Standard for Quick-Disconnect Devices for Use With Gas
Fuel, ANSI Z21.41 or Quick Disconnect For Use With Gas
Fuel CAN 1-6.9. Adequate means must be provided to
limit the movement of the appliance without depending
on the connection and the quick disconnect device or its
associated piping.
A drip leg must be used at each appliance. Refer to
NFPA54/ANSI Z223.1 - Latest Edition (National Fuel Gas
Code) for proper drip leg installation.
General export installations
Installation must conform with Local and National instal-
lation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the
proper installation and/or operation of your appliance,
please contact your local distributor. If you do not have a
local distributor, please call Blodgett Combi at 0011-802658-6600.
Attachment Plate
(secure with leg mount bolt)
Quick Connect
Gas Hose
Restraint
Installation of Gas Hose and Restraint
(Single Section Shown)
Figure 8
Gas Supply Line
IMPORTANT: Cable restraint should
be fastened as close as possible
to the exible connector and short
enough to prevent any strain on the
exible connector.
At maximum stretch of shortened
restraint, the exible connector
should be easy to install and quick
to connect.
14
WARNING!!
Final check list must be performed by a quali-
ed installer only.
OVEN EXTERIOR
1. Check that the oven has not been damaged in transit
(dents, scratches, etc.)
2. Check/adjust the height and check that the oven is
placed level (horizontally)
3. Check/adjust oven door
CONNECTIONS
1. Check for correct water connection
2. Turn on water supply
3. Check for leaks
4. Turn off water supply
Installation
Final Check Lists
OVEN INTERIOR
1. Check that lter housing is mounted correctly
2. Check interior light
3. Clean the oven
CONTROL
1. Check and adjust, if necessary, each of the preset
values
2. Heat up the oven at 480°F (249°C) for approximately
5 minutes.
5. Check and clean dirt lter
6. Turn on water supply again
7. Check hand shower
8. Check for correct electrical connection
9. Check for correct gas connection (if applicable)
10. Check connection to drip tray
11. Check for correct mounting of drip tray
12. Check for correct fall of hose from drip tray, and check
for leaks
13. Check for correct exhaust and drain connection
14. Clean the oven
15. Apply steel oil
15