Blodgett B24C-FF User Manual

Owner’s Manual
Sectional Fryer Filter System
IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this manual for the life of the equipment:
Model #: __________________________
Serial #: __________________________
Date Purchased: ___________________
WARNING
Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Read installation, operation, and maintenance instructions thoroughly before installing or servicing this equipment.
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526 USA • www.blodgettrange.com
MANUAL 1184960 $18.00
SECTIONAL FRYER FILTER SYSTEM
MANUAL SECTION SR
SAFETY PRECAUTIONS SECTIONAL FRYER FILTER SYSTEM

SAFETY PRECAUTIONS

Before installing and operating this equipment, be sure everyone involved in its operation is fully trained and aware of precautions. Accidents and problems can be caused by failure to follow fundamental rules and precautions.
The following symbols, found throughout this manual, alert you to potentially dangerous conditions to the operator, service personnel, or to the equipment.
DANGER
WARNING
CAUTION
NOTICE
This symbol warns of immediate hazards that will result in severe injury or death.
This symbol refers to a potential hazard or unsafe practice that could result in injury or death.
This symbol refers to a potential hazard or unsafe practice that could result in injury, product damage, or property damage.
This symbol refers to information that needs special attention or must be fully understood, even though not dangerous.
WARNING
FIRE HAZARD
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of cooking appliances. Keep area around cooking appliances free and clear of combustibles. Purchaser of equipment must post in a prominent location detailed instructions to be followed in the event the
operator smells gas. Obtain the instructions from the local gas supplier.
WARNING
BURN HAZARD
Contact with hot surfaces will cause severe burns. Always use caution when operating cooking appliances.
WARNING
EXPLOSION AND ASPHYXIATION HAZARD
In the event a gas odor is detected, shut down equipment at the main gas shut-off valve and immediately call the emergency phone number of your gas supplier.
Improper ventilation can result in headaches, drowsiness, nausea, and could result in death. Do not obstruct the flow of combustion and ventilation air to and from cooking appliances.
WARNING
ELECTRIC SHOCK HAZARD
For appliances that use electric power, disconnect the power to the appliance before cleaning. Do not remove panels that require tools to remove.
NOTICE
Blodgett Range appliances are intended for commercial use only. Not for household use. Warranty will be void if service work is performed by other than a qualified technician, or if other than genuine
Blodgett Range replacement parts are installed. Give this Owner’s Manual and important papers to the proper authority to retain for future reference.
Copyright © 2002 by Blodgett Range. All rights reserved. Published in the United States of America.
PAGE 2 OF 20 OWNERS MANUAL 1184960
SECTIONAL FRYER FILTER SYSTEM INTRODUCTION

INTRODUCTION

Congratulations! You have purchased one of the finest pieces of heavy-duty commercial cooking equipment on the market.
You will find that your new equipment, like all Blodgett Range equipment, has been designed and manufactured to meet the toughest standards in the industry. Each piece of Blodgett Range equipment is carefully engineered and designs are verified through laboratory tests and field installations. With proper care and field maintenance, you will experience years of reliable, trouble-free operation. For best results, read this manual carefully.
RETAIN THIS MANUAL FOR FUTURE REFERENCE. This manual is for the Blodgett Range Sectional Fryer Filter System model B24C-FF. The serial plate is located inside the cabinet door (see Figure 1 below). Read these instructions carefully before attempting installation. Installation and initial startup should be performed by
a qualified installer. Unless the installation instructions for this product are followed by a qualified service technician (a person experienced in and knowledgeable with the installation of commercial gas and/or electric cooking equipment) then the terms and conditions on the Manufacturer’s Limited Warranty will be rendered void and no warranty of any kind shall apply.
In the event you have questions concerning the installation, use, care, or service of the product, write to:
Blodgett Range
1100 Old Honeycutt Road
Fuquay-Varina, North Carolina 27526 USA
Figure 1

Location of Serial Plate

Location of Serial Plate
OWNERS MANUAL 1184960 PAGE 3 OF 20
SPECIFICATIONS SECTIONAL FRYER FILTER SYSTEM

SPECIFICATIONS

NOTICE
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, Inc. states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to installation requirements for equipment. Therefore, installations should comply with all local codes.
Blodgett Range reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, additions, or replacements for previously purchased equipment.
This product is intended for commercial use only, not for household use.
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA- B149.2, as applicable, including:
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45 kPa).

DIMENSIONS

Figure 2
Dimensions are in inches and (millimeters).
36" Flue Riser
24" Flue Riser
30"
36"
(762)
(914)
6" (152)
FRONT VIEW
60"
(1524)
72"
(1829)
Flue riser for “deep” depth-option extends rearward 6"
(drain pan size is the same as for “standard” depth).
41-3/4" (1060) 38" (965)
35-3/4" (908)
32" (813)
Front Gas
Manifold
33-3/4"
(859)
2-1/2" (64)
SIDE VIEW
SHIPPING CRATE DIMENSIONS & WEIGHT
Width Height Depth Volume Weight
44.0
45.0
45.5
(1118)
(1143)
Optional drain pan is 12-1/4" (311 mm) wide
and 20" (508 mm) front-to-back.
32"
(813)
4"
(102)
2"
(51)
(1156)
52.1 cu ft
(1.48cum)
24"
(610)
TOP VIEW
200 lbs (91 kg)

CLEARANCES

Clearance must be provided in front of the cabinet for servicing and for operation. If the appliance is installed as part of a battery that has a continuous shared flue riser, follow the minimum clearance requirements for the flue riser of the adjoining section(s).
PAGE 4 OF 20 OWNERS MANUAL 1184960
SECTIONAL FRYER FILTER SYSTEM SPECIFICATIONS

GAS SUPPLY

The Sectional Fryer Filter System does not use any gas, but it does have a 1-1/4" front gas manifold the couples to the adjacent sectional unit(s).

ELECTRICITY SUPPLY

The Sectional Fryer Filter System requires electric power (50Hz or 60Hz single-phase AC). 120V models draw a maximum of 6.5 amps, and have a 7-foot (2134 mm) power cord with a grounded plug. 230V models draw a maximum of 2.6 amps, and have a terminal block for connection to a single-phase 230V source.
The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable.

VENTILATION

WARNING
Improper ventilation can result in personal injury or death. Ventilation which fails to properly remove flue products can cause headaches, drowsiness, nausea, or could result in death.
All gas appliances must be installed in such a manner that the flow of combustion and ventilation air is not obstructed. Provisions for adequate air supply must be provided.
NOTICE
Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the warranty.
Be sure to inspect and clean the ventilation system according to the ventilation equipment manufacturer’s instructions.
The Sectional Fryer Filter System is electrically powered, and so does not require combustion air. However, the flue riser may contain exhaust gasses from adjoining appliances that share an optional continuous flue riser. Follow the ventilation requirements for the adjoining section(s).
OWNERS MANUAL 1184960 PAGE 5 OF 20
OPERATION SECTIONAL FRYER FILTER SYSTEM

OPERATION

DANGER
EXPLOSION HAZARD
In the event a gas odor is detected, shut down equipment at the main shut off valve. Immediately call the emergency phone number of your gas supplier.
WARNING
BURN HAZARD
CONTACT WITH HOT OIL WILL CAUSE SEVERE BURNS. ALWAYS USE CAUTION. OIL AT 200°F IS MORE DANGEROUS THAN BOILING WATER.
The fryer filter system is contained in a cabinet that is part of a battery that includes deep fryers (see Figure 3). The frypot-drains of the fryers are connected to a pipe that drains into a filter pan in the bottom of the filter cabinet. When the power switch of the filter system is turned on, a pump draws the drained oil through a filter on the bottom of the filter pan to remove breading and other impurities, and pumps the oil out of a discharge hose. The discharge hose can be positioned to return the filtered oil to a frypot, to pump it into a container for disposal, or to pump it into a container for storage while the frypot is cleaned.
Figure 3

Fryer Filter System Operation

Filter Discharge Hose
Drain Pan
(Cabinet Doors Not Shown)
Fryer Drain Pipe
PAGE 6 OF 20 OWNERS MANUAL 1184960