NOTES:
1. Hinged cover standard on 20 gallon kettle.
2. Power aid cover (shown) standard on 40-100
gallon kettles.
3. Single or double pantry faucets are optional.
4. 3” tangent drawoff is optional.
5. Dimensions are in inches (mm).
Draft Diverter
N Dia. Flue Outlet
Rear Clearance
6” (152)
D
E
6” (152)
Min. Side
Clearance
4-3/4”
(121)
ASME Approved
Safety Valve
30 PSI
6” (152)
Min. Side Clearance
4” (102)
6-3/4”
(171)
TOP VIEW
F
H
Rim
Height
G
Pilot Access Door
Adjustable
Bullet Feet
Faucet
Bracket
FRONT VIEW
C
L
Gas
Connection
L
S
K
C
L
Electrical
Connection
2” Tangent
Drawoff
P
RIGHT SIDE VIEW
Burner Assy
(not shown in
other views)
M
w/Cover
Open
A I.D.
B O.D.
Cover Open
See notes1&2
(not shown in other views)
R
Optional 3”
Tangent Drawoff
30°
C Dia.
Kettle
Leg Position
APPROVAL/STAMP
P/N S00116 Rev B (6/11)
20G-KLS 40G-KLS 60G-KLS 80G-KLS 100G-KLS
A
20 (508) 26 (660) 30 (762) 31.75 (806) 31.75 (806)
B
26.13 (664) 32.38 (822) 36 (914) 37.75 (959) 37.75 (959)
C
24 (610) 30.38 (772) 33.5 (851) 35.75 (908) 35.75 (908)
D
26.5 (673) 29.13 (740) 29.5 (749) 30.5 (775) 30.5 (775)
E
50.75 (1289) 56.25 (1429) 58.25 (1480) 61.25 (1556) 61.25 (1556)
F
39.5 (1003) 43.25 (1099) 46.25 (1175) 48 (1219) 48 (1219)
G
33.5 (851) 33 (838) 38.13 (968) 43.25 (1099) 43.25 (1099)
H
40 (1016) 41 (1041) 48.88(1241) 56.5 (1435) 62.5 (1588)
J
9 (229) 9 (229) 11 (279) 11.5 (292) 11.5 (292)
K
18.5 (470) 16.75 (425) 21.38 (543) 24.25 (616) 24.25 (616)
L
6.75 (171) 6 (152) 6.13 (156) 8.5 (216) 8.5 (216)
M
73 (1854) 74.75 (1899) 76.63 (1946) 91.5 (2324) 97.5 (2477)
N
6 (152) 6 (152) 7 (178) 7 (178) 7 (178)
P
17.5 (445) 21.38 (543) 24.63 (625) 29.5 (749) 35.25 (895)
R
17.5 (445) 21 (533) 16.63 (422) 24.5 (622) 24.5 (622)
S
12 (305) 12 (305) 12 (305) 12 (305) 12 (305)
SHORT FORM SPECIFICATIONS
Provide Blodgett model 20G-KLS (20 gallon), 40G-KLS (40 gallon), 60G-KLS (60 gallon), 80G-KLS (80 gallon) or 10G-KLS (100 gallon) gas heated, stainless steel, steam jacketed kettle. Unit shall include 2” tangent draw-off valve, (3”optional) and No. 41 cover. 40to 100 gallon units furnishedwith No. 51 spring assistedcover. Steam jacket is insulatedand ASME code
constructedfor maximum workingpressure of 30 PSI. Unit is thermostatically controlled, with electronic ignition standard. Requires 1/2” gas supply and 115 Volt electric service. Provide
options and accessories as indicated.
MAXIMUM INPUT: Natural Gas Propane
20G-KLS 85,000 BTU 85,000 BTU
40G-KLS 100,000 BTU 85,000 BTU
60G-KLS, 80G-KLS & 100G-KLS 145,000 BTU 145,000 BTU
GAS SUPPLY:
1/2" NPT connection required. A gas shut-off valve must be installed
in supply piping convenient and adjacent to unit.
Inlet Pressure:
Natural 4.5" W.C. min, 14” W.C. max
Propane 11" W.C. min, 14” W.C. max
ELECTRICAL CONNECTION:
Requires one 115 Volt, single-phase, 60 HZ, 5 AMP supply.
SHIPPING INFORMATION:
Approx. Weight:
20G-KLS 468 lbs. (212 kg)
40G-KLS 620 lbs. (281 kg)
60G-KLS 885 lbs. (401 kg)
80G-KLS 1067 lbs. (484 kg)
100G-KLS 1135 lbs. (515 kg)