Block HLV310-500/100 Catalog Page

Radio interference suppression filter, three-phase with neutral conductor, low leakage current
HLV 310
Typ HLV 310-500/8 HLV 310-500/12 HLV 310-500/16 HLV 310-500/30 HLV 310-500/42 HLV 310-500/55
Special features
Characteristics Suitable for the medical
field
Suitable for the medical field
Suitable for the medical field
Suitable for the medical field
Suitable for the medical field
Suitable for the medical field
Operating data
Rated voltage 3 x 520 Vac 3 x 520 Vac 3 x 520 Vac 3 x 520 Vac 3 x 520 Vac 3 x 520 Vac
Voltage range 0 - 3 x 520 Vac 0 - 3 x 520 Vac 0 - 3 x 520 Vac 0 - 3 x 520 Vac 0 - 3 x 520 Vac 0 - 3 x 520 Vac
Rated current 3 x 8 A+N 3 x 12 A+N 3 x 12 A+N 3 x 30 A+N 3 x 42 A+N 3 x 55 A+N
Leakage current (50 Hz)* <1.0 mA <1.0 mA <1.0 mA <1.0 mA <1.0 mA <1.0 mA
Leakage current (50 Hz)** <3.5 mA <3.5 mA <3.5 mA <3.5 mA <3.5 mA <3.5 mA
Rated frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz
Overrating Capacity 150 %, shortly 150 %, shortly 150 %, shortly 150 %, shortly 150 %, shortly 150 %, shortly
Environment
Climatic category 25/085/21
[in accordance with EN 60068-1]
25/085/21 [in accordance with EN 60068-1]
25/085/21 [in accordance with EN 60068-1]
25/085/21 [in accordance with EN 60068-1]
25/085/21 [in accordance with EN 60068-1]
25/085/21 [in accordance with EN 60068-1]
Ambient temperature max. 50 °C 50 °C 50 °C 50 °C 50 °C 50 °C
Safety and protection
Type
Metal enclosure Metal enclosure Metal enclosure Metal enclosure Metal enclosure Metal enclosure
Protection index
IP 20 IP 20 IP 20 IP 20 IP 20 IP 20
Safety class (prepared)
I I I I I I
Test voltage 2150 Vdc Phase/Phase,
2700 Vdc Phase/PE
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
Notes
*
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
**
Leakage current by loss of two phases
Leakage current by loss of two phases
Leakage current by loss of two phases
Leakage current by loss of two phases
Leakage current by loss of two phases
Leakage current by loss of two phases
Order numbers
Order Number HLV 310-500/8 HLV 310-500/12 HLV 310-500/16 HLV 310-500/30 HLV 310-500/42 HLV 310-500/55
+
-
Reactors / EMI filters
Three-phase radio interference suppression filters with neutral conductor
3
Radio interference suppression filter, three-phase with neutral conductor, low leakage current
HLV 310
General Data
Voltage range 0 - 3 x 520 Vac
Rated current 3 x 8 - 3 x 250 A+N
Leakage current <1.0 mA
Degree of protection IP 20
Advantages
For enhanced requirements
Low leakage current
Single-stage filter concept
Efficient filter effect against line-bound interference emissions
Increase in the interference immunity of the connected consumer
Applications
Radio interference suppression filter for line-side interference suppression of single devices, frequency converters or as group interference suppression.
Sample application
StandardsZ
Radio interference suppression filter to DIN EN 60939-2
Subject to change
550
Approvals J Z
+
-
1.1
1.2
5.1
1.3
2.1
2.2
3.1
3.2
3.3
5.2
4.0
Reactors / EMI filters
Three-phase radio interference suppression filters with neutral conductor
3
Radio interference suppression filter, three-phase with neutral conductor, low leakage current
HLV 310
Typ HLV 310-500/8 HLV 310-500/12 HLV 310-500/16 HLV 310-500/30 HLV 310-500/42 HLV 310-500/55
Special features
Characteristics Suitable for the medical
field
Operating data
Rated voltage 3 x 520 Vac 3 x 520 Vac 3 x 520 Vac 3 x 520 Vac 3 x 520 Vac 3 x 520 Vac
Voltage range 0 - 3 x 520 Vac 0 - 3 x 520 Vac 0 - 3 x 520 Vac 0 - 3 x 520 Vac 0 - 3 x 520 Vac 0 - 3 x 520 Vac
Rated current 3 x 8 A+N 3 x 12 A+N 3 x 12 A+N 3 x 30 A+N 3 x 42 A+N 3 x 55 A+N
Leakage current (50 Hz)* <1.0 mA <1.0 mA <1.0 mA <1.0 mA <1.0 mA <1.0 mA
Leakage current (50 Hz)** <3.5 mA <3.5 mA <3.5 mA <3.5 mA <3.5 mA <3.5 mA
Rated frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz
Overrating Capacity 150 %, shortly 150 %, shortly 150 %, shortly 150 %, shortly 150 %, shortly 150 %, shortly
Environment
Climatic category 25/085/21
Ambient temperature max. 50 °C 50 °C 50 °C 50 °C 50 °C 50 °C
[in accordance with EN 60068-1]
Safety and protection
Type
Protection index
Safety class (prepared)
Test voltage 2150 Vdc Phase/Phase,
Metal enclosure Metal enclosure Metal enclosure Metal enclosure Metal enclosure Metal enclosure
IP 20 IP 20 IP 20 IP 20 IP 20 IP 20
I I I I I I
2700 Vdc Phase/PE
Notes
*
**
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current by loss of two phases
Order numbers
Order Number HLV 310-500/8 HLV 310-500/12 HLV 310-500/16 HLV 310-500/30 HLV 310-500/42 HLV 310-500/55
Suitable for the medical field
25/085/21 [in accordance with EN 60068-1]
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current by loss of two phases
Suitable for the medical field
25/085/21 [in accordance with EN 60068-1]
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current by loss of two phases
Suitable for the medical field
25/085/21 [in accordance with EN 60068-1]
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current by loss of two phases
Suitable for the medical field
25/085/21 [in accordance with EN 60068-1]
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current by loss of two phases
Suitable for the medical field
25/085/21 [in accordance with EN 60068-1]
2150 Vdc Phase/Phase, 2700 Vdc Phase/PE
Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 %
Leakage current by loss of two phases
Subject to change
551