What’s In The Box? 3
Getting It Out Of The Box 3
Powering Up! 3
Getting A Hold Of Us 3
Safety Instructions (Don’t Stick Your Hand In The Toaster!) 4
2. Meet The TOURnado™ CSI COB 5
Main Features 5
DMX Quick Reference 5
The TOURnado™ CSI COB Pin-up Picture 6
3. Setup 7
Fuse Replacement 7
Connecting A Bunch Of TOURnado™ CSI COB Fixtures 7
Data/DMX Cables 7
Cable Connectors 8
3-Pin??? 5-Pin??? Huh? 8
Take It To The Next Level: Setting up DMX Control 8
Fixture Linking (Master/Slave Mode) 9
Mounting/Rigging 9
4. Operating Adjustments 10
Navigating The Control Panel 10
Control Panel Menu Structure 11
DMX Mode 11
Set The Starting DMX Address 12
Select the DMX Channel Mode 12
Slave Mode 12
Strobe Mode 12
Dimming Mode Settings 13
LED Display and Key Lock Setting 12
DMX Channel Values In-Depth 13
Troubleshooting 13
5. Appendix 14
A Quick DMX Lesson 14
Keeping Your TOURnado™ CSI COB As Good As New 15
Returns (Gasp!) 15
Shipping Issues 15
Tech Specs 16
Dimensional Drawings 17
• 1 x TOURnado™ CSI COB Professional LED PAR Fixture
• 1 x IP Rated AC power cord
• 1 x Set of IP Rated DMX in/out cables
• This Lovely User Manual
Getting It Out Of The Box
Congratulations aspiring crime ghter and/or psychedelic music acionado for purchasing
the TOURnado™ CSI COB! So now that you’ve got your new TOURnado™ (or hopefully,
TOURnados!), you should carefully unpack the box and check the contents to ensure that
all parts are present and in good condition. If anything looks as if it has been damaged
in transit, notify the shipper immediately and keep the packing material for inspection.
Again, please save the carton and all packing materials. If a xture must be returned
to the factory, it is important that the xture be returned in the original factory box and
packing.
Powering Up!
All xtures must be powered directly off a switched circuit and cannot be run off a
rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer
channel is used solely for a 0% to 100% switch.
AC Voltage Switch - Not all xtures have a voltage select switch, so please verify that the
xture you receive is suitable for your local power supply. See the label on the xture or
refer to the xture’s specications chart for more information. A xture’s listed current
rating is its average current draw under normal conditions. Check the xture or device
carefully to make sure that if a voltage selection switch exists that it is set to the correct
line voltage you will use.
Warning! Verify that the voltage select switch on your unit matches the line
voltage applied. Damage to your xture may result if the line voltage applied does
not match the voltage indicated on the voltage selector switch. All xtures must
be connected to circuits with a suitable Ground (Earthing).
Getting A Hold Of Us
If something happens goes wrong, please visit www.blizzardlighting.com/
support and open a support ticket. We’ll be happy to help, honest.
Disclaimer: The information and specications contained in this document are subject
to change without notice. Blizzard Lighting™ assumes no responsibility or liability for any
errors or omissions that may appear in this user manual. Blizzard Lighting™ reserves the
right to update the existing document or to create a new document to correct any errors
or omissions at any time. You can download the latest version of this document from www.
blizzardlighting.com.
• Please keep this User Guide for future use. If you sell the unit to someone
else, be sure that they also receive this User Guide.
• ALWAYS make sure that you are connecting to the proper voltage, and that
the line voltage you are connecting to is not higher than that stated on the de-
cal or rear panel of the xture.
• Make sure there are no ammable materials close to the unit while operating.
• The unit must be installed in a location with adequate ventilation, at least
20in (50cm) from adjacent surfaces.
• ALWAYS disconnect from the power source before servicing or replacing fuse
and be sure to replace with same fuse size and type.
• ALWAYS secure xture using a safety chain. NEVER carry the xture by its
cord. Use its carrying handles.
• DO NOT operate at ambient temperatures higher than 104°F (40°C).
• In the event of a serious operating problem, stop using the unit immediately.
NEVER try to repair the unit by yourself. Repairs carried out by unskilled people
can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
• NEVER connect the device to a dimmer pack.
• Make sure the power cord is never crimped or damaged.
• Never disconnect the power cord by pulling or tugging on the cord.
• Avoid direct eye exposure to the light source while it is on.
Caution! There are no user serviceable parts inside the unit. Do not
open the housing or attempt any repairs yourself. In the unlikely event
your unit may require service, please contact Blizzard Lighting at www.
blizzardlighting.com/support.
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor & shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms
Cables must have a male XLR connector on one end and a female XLR
connector on the other end. (Duh!)
CAUTION: Do not allow contact between the common and the x-
ture’s chassis ground. Grounding the common can cause a ground
loop, and your xture may perform erratically. Test cables with an
ohm meter to verify correct polarity and to make sure the pins are not
grounded or shorted to the shield or each other.
3-Pin??? 5-Pin??? Huh?!?
If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter.
They are widely available over the internet and from specialty retailers If you’d like to build your own, the
chart below details a proper cable conversion:
Conductor3-Pin Female
(Output)
5-Pin Male
(Input)
Ground/ShieldPin 1Pin 1
DMX Data (-)Pin 2Pin 2
DMX Data (+)Pin 3Pin 3
Not Used.No Connection.No Connection.
Not Used.No Connection.No Connection.
Take It To The Next Level: Setting Up DMX Control
Step 1: Connect the male connector of the
DMX cable to the female connector (output)
on the controller.
Step 2: Connect the female connector of the
DMX cable to the rst xture’s male connector (input). Note: It doesn’t matter which
xture address is the rst one connected.
We recommend connecting the xtures in
terms of their proximity to the controller,
rather than connecting the lowest xture
number rst, and so on.
All the goodies and different modes possible with the TOURnado™ CSI
COB are accessed by using the control panel on the rear of the xture.
There are 4 control buttons below the LED display which allow you to
navigate through the various control panel menus.
<MENU>
Is used to navigate to the previous higher-level menu item.
<UP>
Scrolls through menu items and numbers in ascending order.
<DOWN>
Scrolls through menu items and numbers in descending order.
<ENTER>
Is used to select and conrm/store the current selection.
The Control Panel LED Display shows the menu items you select from
the menu map on page #11. When a menu function is selected, the
display will show immediately the rst available option for the selected
menu function. To select a menu item, press <ENTER>.
Use the <UP> and <DOWN> buttons to navigate the menu options.
Press the <ENTER> button to select the menu function currently displayed, or to enable a menu option. To return to the previous option or
menu, press the <MENU> button.
Allows the unit to be controlled by any universal DMX controller.
Set the Starting DMX Address:
The default mode for the xture is DMX, so the rst menu item that you can edit is the
starting DMX address.
1.) Navigate the menu using the <UP/DOWN> buttons until you reach Addr.
2.) Push the <ENTER> button.
3.) Use the <UP/DOWN> buttons to select a DMX channel from 001-512.
4.) Press the <ENTER> button to conrm.
Select the DMX Channel Mode:
1.) Navigate the menu using the <UP/DOWN> buttons until you reach CHnd.
2.) Push the <ENTER> button.
3.) Use the <UP/DOWN> buttons to select either 1CH, or 3CH mode.
4.) Press the <ENTER> button to conrm.
Slave Mode:
1.) Daisy chain the xtures DMX in/out, having the controller at the beginning of the line.
2.) There is nothing else to it! The rst xture in the DMX chain is the master xture, and
the following xtures will be slave units that follow the master xture.
Strobe Mode:
1.) Navigate the menu using the <UP/DOWN> buttons until you reach STAT.
2.) Push the <ENTER> button.
3.) Use the <UP/DOWN> buttons to adjust the ash rate from 000-255.
4.) Press the <ENTER> button to conrm.
LINLinear dimming curve
SQRSquare law curve
ISQRInverse square law curve
SCURS-curve
LIN.Linear dimming curve (smooth)
SQR.Square law curve (smooth)
ISQR.Inverse square law curve (smooth)
SCUR.S-curve (smooth)
2MINLED menu display shuts off after 2 minutes of inactivity
If set to YES, the menu will lock after 2 minutes of inactivity. To
No Function
Normal Strobe (Slow <--> Fast)
Random Strobe (Slow <--> Fast)
Electronic Sinewave (Slow <--> Fast)
Opening pulse(Slow <--> Fast)
Closing pulse (Slow <--> Fast)
No Function
32-Bit Dimmer
As set in the control menu display
Linear curve
Square law curve
Inverse square law curve
S-curve
Linear curve and smooth
Square law curve and smooth
Inverse square law curve and smooth
S-curve and smooth
Use the dimmer mode which menu had set up
DMX Values In-Depth (1-Channel Mode)
ChannelValueWhat It Does
1000 <--> 255Dimmer (0% <--> 100%)
Troubleshooting
SymptomSolution
Fixture Auto-Shut
Off
Beam is DimCheck optical system and clean excess dust/grime. Also, the overheat protec-
No Light OutputCheck to ensure xture is operating under correct mode, IE DMX/Etc., if ap-
No PowerCheck fuse, AC cord and circuit for malfunction.
Fixture Not Responding / Responding
Erratically
Check the fan in the xture. If it is stopped or moving slower than normal,
the unit may have shut itself off due to high heat. This is to protect the xture
from overheating. Clear the fan of obstructions, or return the unit for service.
tion mode (100%/80%/50% output) could be active. To check, see the LED
menu display reading at INFO>SOFT>POW.
plicable.
Make sure all connectors are seated properly and securely.
Use Only DMX Cables and/or check cables for defects
Install a Terminator.
Reset xture(s).
please open a support ticket at www.blizzardlighting.com/support.
If your problem isn’t listed, or if problems persist,
DMX (aka DMX-512) was created in 1986 by the United States Institute for Theatre
Technology (USITT) as a standardized method for connecting lighting consoles to lighting
dimmer modules. It was revised in 1990 and again in 2000 to allow more exibility. The
Entertainment Services and Technology Association (ESTA) has since assumed control over
the DMX512 standard. It has also been approved and recognized for ANSI standard clas-
sication.
DMX covers (and is an abbreviation for) Digital MultipleXed signals. It is the most common
communications standard used by lighting and related stage equipment.
DMX provides up to 512 control “channels” per data link. Each of these channels was originally intended to control lamp dimmer levels. You can think of it as 512 faders on a lighting
console, connected to 512 light bulbs. Each slider’s position is sent over the data link as an
8-bit number having a value between 0 and 255. The value 0 corresponds to the light bulb
being completely off while 255 corresponds to the light bulb being fully on.
DMX data is transmitted at 250,000 bits per second using the RS-485 transmission standard over two wires. As with microphone cables, a grounded cable shield is used to prevent
interference with other signals.
There are ve pins on a DMX connector: a wire for ground (cable shield), two wires for
“Primary” communication which goes from a DMX source to a DMX receiver, and two wires
for a “Secondary” communication which goes from a DMX receiver back to a DMX source.
Generally, the “Secondary” channel is not used so data ows only from sources to receivers. Hence, most of us are most familiar with DMX-512 as being employer over typical
3-pin “mic cables,” although this does not conform to the dened standard.
DMX is connected using a daisy-chain conguration where the source connects to the input
of the rst device, the output of the rst device connects to the input of the next device,
and so on. The standard allows for up to 32 devices on a single DMX link.
Each receiving device typically has a means for setting the “starting channel number” that
it will respond to. For example, if two 6-channel xtures are used, the rst xture might
be set to start at channel 1 so it would respond to DMX channels 1 through 6, and the next
xture would be set to start at channel 7 so it would respond to channels 7 through 12.
The greatest strength of the DMX communications protocol is that it is very simple and
robust. It involves transmitting a reset condition (indicating the start of a new “packet”),
a start code, and up to 512 bytes of data. Data packets are transmitted continuously. As
soon as one packet is nished, another can begin with no delay if desired (usually another
follows within 1 ms). If nothing is changing (i.e. no lamp levels change) the same data will
be sent out over and over again. This is a great feature of DMX -- if for some reason the
data is not interpreted the rst time around, it will be re-sent shortly.
Not all 512 channels need to be output per packet, and in fact, it is very uncommon to nd
all 512 used. The fewer channels are used, the higher the “refresh” rate. It is possible to
get DMX refreshes at around 1000 times per second if only 24 channels are being transmitted. If all 512 channels are being transmitted, the refresh rate is around 44 times per
second.
In summary, since its design and evolution in the 1980’s DMX has become the standard
for lighting control. It is exible, robust, and scalable, and its ability to control everything
from dimmer packs to moving lights to foggers to lasers makes it an indispensable tool for
any lighting designer or lighting performer.
The xture you’ve received is a rugged, tough piece of pro lighting equipment, and as long as you take care of it, it will take care of you. That said, like
anything, you’ll need to take care of it if you want it to operate as designed.
You should absolutely keep the xture clean, especially if you are using it in an
environment with a lot of dust, fog, haze, wild animals, wild teenagers or spilled
drinks.
Cleaning the optics routinely with a suitable glass cleaner will greatly improve
the quality of light output. Keeping the fans free of dust and debris will keep
the xture running cool and prevent damage from overheating.
In transit, keep the xtures in cases. You wouldn’t throw a prized guitar,
drumset, or other piece of expensive gear into a gear trailer without a case,
and similarly, you shouldn’t even think about doing it with your shiny new light
xtures.
Common sense and taking care of your xtures will be the single biggest thing
you can do to keep them running at peak performance and let you worry about
designing a great light show, putting on a great concert, or maximizing your client’s satisfaction and “wow factor.” That’s what it’s all about, after all!
Returns (Gasp!)
We’ve taken a lot of precautions to make sure you never even have to worry
about sending a defective unit back, or sending a unit in for service. But, like
any complex piece of equipment designed and built by humans, once in a while,
something doesn’t go as planned. If you nd yourself with a xture that isn’t
behaving like a good little xture should, you’ll need to obtain a Return Authori-
zation (RA).
Don’t worry, this is easy. Just go to our website and open a support ticket at
www.blizzardlighting.com/tickets, and we’ll issue you an RA. Then, you’ll need
to send the unit to us using a trackable, pre-paid freight method. We suggest
using USPS Priority or UPS. Make sure you carefully pack the xture for transit,
and whenever possible, use the original box & packing for shipping.
When returning your xture for service, be sure to include the following:
1.) Your contact information (Name, Address, Phone Number, Email address).
2.) The RA# issued to you
3.) A brief description of the problem/symptoms.
We will, at our discretion, repair or replace the xture. Please remember that
any shipping damage which occurs in transit to us is the customer’s responsibility, so pack it well!
Shipping Issues
Damage incurred in shipping is the responsibility of the shipper, and
must be reported to the carrier immediately upon receipt of the items.
Claims must be made within seven (7) days of receipt.