BLAUBERG Sileo Service Instructions Manual

5 (2)
EN
Sileo
Service Instructions
BLAUBERG VENTILATOREN GmbH is happy to offer you a new generation product, the BLAUBERG Sileo fan. The solid team of high-qualified professionals with many years of working experience, technological innovations in design and production, high-quality components and materials from the top worldwide producers have become the precondition for the best fan in its class. BLAUBERG Sileo fan is the combination of design, high performance and silence operation.
INTRODUCTION
The present operation manual contains a technical description, technical data sheets, operation and mounting guidelines, safety precautions and warnings for safe and correct operation of the fan BLAUBERG Sileo.
USE
BLAUBERG Sileo fan is designed for ventilation of residential and public premises heated during winter season and is constructed for wall or ceiling mounting, fig. 2-4. The fan is equipped with a back valve to prevent air backdrafting when the fan is off.
COMPLETE SET
The complete set includes:
fan - 1 item; screws and dowels - 4 items; plastic screwdriver (for the models with a timer) - 1 item; operation manual; packing box.
The fan design is regularly improved, so some models can slightly differ from those ones described in this operation manual.
22
BASIC CHARACTERISTICS
Table 1. Technical data
Table 2. Fan modifications
23
Rated power [W]
3
Max. air flow [m /h]
RPM [min-1]
Noise level, 3 m [dBA]
min
max
Sileo
125
Sileo 150
17
19
17
7,5
225 31818797
1540 207021152165
28 333225
Parameters
Model
Power voltage and frequency [V/Hz]
230/50
Option
Switch
Turn-off delay timer
Humidity sensor
Motion sensor
Sileo 100
Turn-on delay timer
Fan model
Sileo 100 S
Sileo 100 T
Sileo 100 H
Sileo 100 ST
Sileo 100 SH
Sileo 100 IR
Sileo 125
Sileo 125 S
Sileo 125 T
Sileo 125 H
Sileo 125 ST
Sileo 125 SH
Sileo 125 IR
Sileo 150
Sileo 150 S
Sileo 150 T
Sileo 150 H
Sileo 150 ST
Sileo 150 SH
Sileo 150 IR
Sileo Max 150
Sileo Max 150 S
Sileo Max 150 T
Sileo Max 150 H
Sileo Max 150 ST
Sileo Max150 SH
Sileo Max 150 IR
Switch - integrated pull cord switch. Timer - turn-on delay timer adjustable from 0 up to 2 minutes
(only Sileo 150 and Sileo Max 150 models) and turn-off delay timer adjustable from 2 up to 30 minutes.
Humidity sensor - humidity control with set point from 60% up to 90%. Motion sensor - reach distance from 1 to 4 m and sensor viewing angle
up to 100°.
The fan does not cause interference with radio-, TV- or video- equipment.
Sileo
100
230/50 230/50 230/50 230/50 230/50
Sileo Max 150
19
283
1780
32
22
375
2300
38
min
max
Dimensions [mm]
Table 3. Overall dimensions
Model
Sileo 100
OPERATION RULES
The fan is rated for connection to 220...240 V / 50 Hz power mains and is designed for continuous operation always connected to power mains.
The air motion direction in the system must match the pointer on the fan casing.
The fan is rated for operation at ambient temperature from +1 °C up to +45 °C.
The fan does not require grounding.
24
Fig. 1
Sileo 125
Sileo 150 Sileo Max 150
a
158
182
214
b
136
158
190
c
81
91
98
d
99
124
148
e
26
27
32
SAFETY RULES
All operations related to the fan electrical connections, servicing and repair works are allowed only after the fan disconnection from power mains. All mounting and servicing operations are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user's manual. The single-phase power grid must comply with the acting local electrical norms and standards.
The fixed electrical wiring must be equipped with an automatic switch that is used for connection of the fan to power mains with gap on all poles at least 3 mm. Make sure the impeller, the casing and the grille are not damaged before connecting the fan to power mains. The casing internals must be free of any foreign objects which can damage the impeller blades.
Misuse of the fan or any unauthorized modification are not allowed. Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney flues or other fire-protection devices. Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back
drafting.
The maximum permitted pressure difference per living units is 4 Pa. The transported air must not contain any dust or other solid impurities, sticky substances or fibrous materials.
The fan is not rated for operation in a media that contains hazardous or explosive materials and vapours, i.e. spirits, gasoline, insecticides, etc. Do not close or block the fan intake or exhaust vent not to disturb the natural air passage.
Do not sit on the fan and do not put objects on the fan.
Follow the guidelines of this operation manual to ensure durable operation of the product.
25
MOUNTING AND SETUP
The fan is designed for ceiling or wall mounting and installation into a ventilation shaft or connection to a round air duct of respective diameter, fig. 2-4.
The fan mounting sequence is shown in fig. 5-13. The wiring diagrams are shown in fig. 14-25.
26
Fig. 2
Fig. 4
Fig. 3