Blancett Turbine Flow Meter Specifications

Turbine Flow Meter
Top Load 1 in. and 2 in. Meters
DESCRIPTION
The Top Load Turbine Flow Meter is designed to withstand the demands of the most rigorous flow measurement applications. Originally developed for the secondary oil recovery market, the Top Load Turbine Flow Meter is an ideal meter for liquid flow measurement on or off the oil field.
The meter features a rugged 316 stainless steel housing, rotor shaft and rotor support assemblies, C17-4 PH stainless steel rotor, and hybrid ceramic ball bearings. The meter maintains measurement accuracy and mechanical integrity in the corrosive and abrasive fluids commonly found in oil field water flood projects and many industrial applications.
When paired with a Blancett flow monitor, the meter meets a wide range of measurement requirements. This makes it ideal for applications such as pipelines, production and injection fields, mining operations, offshore facilities, and other industrial applications. For a full list of Blancett flow monitors, see www.badgermeter.com.
FEATURES
Offers accurate and repeatable flow measurement in ranges from 5…225 gpm (18.9… 851.72 lpm)
Cost-effective solution for turbine flow meter applications
Rugged 316 stainless steel construction offers long service life in severe operating environments
Available in NPT
NIST-traceable calibration
Installation in 1 in. and 2 in. pipe sizes
Can integrate electronically with a Blancett flow monitor and K-factor Scaler, or the F-to-I/F-to-V Intelligent Converter
Field replaceable repair kits allow for turbine replacement without loss of accuracy
Can be repaired without removing the body from the line
INSTALLATION
The Top Load Turbine Flow Meter is simple to install and service. It operates in any orientation (horizontal to vertical) as long as the flow direction arrow is aligned in the same direction as the actual line flow. For optimum performance, the meter should be installed with a minimum of 10 diameters upstream straight pipe length and 5 diameters downstream straight pipe length.
REPAIR KITS
Designed for easy field service of a damaged turbine assembly, the repair kits replace only the internal parts, rather than replacing the entire meter.
Each repair kit assembly is factory calibrated to provide accuracy throughout the entire flow range. Each kit is complete and includes a new K-factor, which is the calibrated number of pulses generated by each gallon of liquid. Recalibration of the monitor or other electronics use the K-factor to provide accurate output data.
TRB-DS-02470-EN-01 (September 2018)
Product Data Sheet
Turbine Flow Meter, Top Load 1 in. and 2 in. Meters
+1%
+%
AVG. K-FACTOR (K)
-%
STANDARD TURNDOWN APPROX. 10:1
OPERATING PRINCIPLE
Fluid entering the meter passes through the inlet flow straightener which reduces its turbulent flow pattern and improves the fluid’s velocity profile. Fluid then passes through the turbine, causing it to rotate at a speed proportional to fluid velocity. As each turbine blade passes through the magnetic field at the base of the transducer, an AC voltage pulse is generated in the pickup coil. These pulses produce an output frequency proportional to the volumetric flow through the meter.
Magnetic Pickup
or
Other Frequency
Output Device
Output
Turbine Rotor
Signal
KFACTOR
The K-factor represents the number of output pulses transmitted per gallon of fluid passing through the turbine meter. Each turbine has a unique K-factor. However, turbine meters are not functionally consistent throughout the full flow range of the meter.
There are several forms of friction inherent in the turbine meters that retard the rotational movement of the turbine rotor. These frictional forces include: magnetic drag, created by electromagnetic forces of pickup transducers; mechanical drag, due to bearing friction; and viscous drag, produced by flowing fluid.
As flow increases, the frictional forces are minimized and the free-wheeling motion of the turbine rotor becomes more linear (proportional to flow). This is approximately a 15:1 turndown ratio from the maximum flow rate down to the minimum flow rate.
Typical K-factor Curve (Pulse per US Gallon)
(CYCLES/GALLON)
CTOR A
K-F
RATE
(CYCLES/SEC)
FLOW AT
LUE A
V
FREQUENCY
OF %
OUTPUT
100%
50%
0% 10%
K-FACTOR (PULSES/GALLON)
50%
FULL FLOW RANGE
LINEAR FLOW RANGE
100%
LINEARITY (DESIGN DEVIATION)
-1%
K
-
F
A
C
T
O
R
(
P
S
U
L
)
N
O
L
L
A
G
/
E
TRB-DS-02470-EN-01Page 2 September 2018
SPECIFICATIONS
Body 316 stainless steel Rotor C17-4PH stainless steel
Materials of Construction
Operating Temperature –150…350° F (–101…177° C)
Pressure Rating 1500 psi max.
End Connections NPT
Turndown Ratio 15:1
Accuracy ±1% of reading
Repeatability ±0.1%
Calibration Water (NIST-traceable calibration)
Pickup B111129
Certifications
Bearing
Rotor Shaft 316 stainless steel Rotor Support 316 stainless steel O-ring Buna-N
Hybrid ceramic ball bearing with AMS 5898 duplex stainless steel race and stainless steel retainer
METER PARTS
Specications
Magnetic Pickup
External Retainer Ring
O-Ring
Shaft Nut
Flow Straightener Shaft
Rotor Support
Magnetic Pickup Hub
Insert
Retainer Nut
Meter Housing
Hybrid Ceramic Ball Bearing
Rotor
TRB-DS-02470-EN-01 Page 3 September 2018
Turbine Flow Meter, Top Load 1 in. and 2 in. Meters
PART NUMBER INFORMATION
1
Part
Number
B411-110
B411-120
1
Includes Low Drag 3 in. Mag Pickup, p/n B111129, -150…330° F (-101…165° C), suitable for all mounting styles
Bore Size
1 in.
(25.4 mm)
2 in.
(50.8 mm)
End
Connections
1 in. male
NPT
2 in. male
NPT
Max.
PSI
1500
1500
gpm (lpm) bpd m/d
5…75
(18.9…283.91)
15…225
(56.78…851.72)
Flow Ranges
171.43…2571.43 27.26…408.82 40 870 2
514.29…7714.29 81.76…1226.47 20 52 14
Strainer
Mesh
Approx. K-factor
Pulse/Gal
Meter
Weight
(lb)
End to End
Length
6 in.
(152.4 mm)
6 in.
(152.4 mm)
Control. Manage. Optimize.
Blancett is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specications without notice, except to the extent an outstanding contractual obligation exists. © 2018 Badger Meter, Inc. All rights reserved.
www.badgermeter.com
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882 Europe, Eastern Europe Branch Oce (for Poland, Latvia, Lithuania, Estonia, Ukraine, Belarus) | Badger Meter Europe | ul. Korfantego 6 | 44-193 Knurów | Poland | +48-32-236-8787 Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuen | Germany | +49-7025-9208-0 Europe, Middle East Branch Oce | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Oce #C209 | Dubai / UAE | +971-4-371 2503 Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01 Asia Pacic | Badger Meter | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836 Switzerland | Badger Meter Swiss AG | Mittelholzerstrasse 8 | 3006 Bern | Switzerland | +41-31-932 01 11