Blancett B3000 Specifications

Page 1
Flow Monitor
B3000 Series
DESCRIPTION
The B3000 Series flow monitor is a flexible, durable, easy-to-use platform for your flow metering applications. Our trusted flow metering technology now offers a new flow monitor with more options and features than ever before with the B3000 Series.
OPERATION
This monitor is capable of accepting low-level frequency input signals typically found in turbine flow sensors. The output signal for these type of sensors is a frequency proportional to the rate of flow. The B3000 monitor uses the frequency information to calculate flow rate and total flow. Through the use of the programming buttons, you can select rate units, total units and unit time intervals among other functions. If required, the flow monitor can easily be reconfigured in the field. Finally, you can choose between simultaneously showing rate and total, or alternating between rate and grand total.
The monitor is available in three levels of functionality and two packaging options. The base model provides all the functions necessary for the most common flow metering applications. The advanced version adds communications capabilities over an RS485 bus using Modbus RTU and control outputs. The third version is a solar-powered model (NEMA 4X only).
Packaging options include a polycarbonate, NEMA 4X version and an aluminum explosion proof enclosure.
APPLICATIONS
The B3000 monitor is suitable for application in a wide variety of metering needs. A few of the more common industries are:
Secondary oil recovery applications
Remediation and reclamation
Fracture/refracture
Coal bed methane
Regulatory compliance and environmental accountability
Industrial chemicals
Aggressive chemical processing applications
Semiconductor manufacturing
Fertilizer production and dispensing
Pesticide manufacture
Liquid batching and water cooling
FEATURES
Robust alarm parameters provide faster warning when something changes in the process or pipeline.
Greater control and greater visibility of batch operations.
Advanced connectivity options allow you to connect meters to your network for remote monitoring and process automation capabilities.
Solar, battery, and 4…20 milliamperes loop power options provide the ability to install in a remote location and be up and running immediately, maintain readings and settings during power loss, and a battery life up to 8 years.
Updated display and totalization options provide more flow information, including simultaneous display of rate and total as well as standard, batch and grand totals.
Various mounting and enclosure options provide a B3000 model for your operation.
DSY-DS-00691-EN-10 (November 2018)
Product Data Sheet
Page 2
Part Number Construction
PART NUMBER CONSTRUCTION
Blancett B3000 Display
Model
Blancett B3000 Display B30
Model
Base B
Advanced A
Solar S
Mounting
Meter M
Remote R
Swivel S
Units of Measure
Customer Selectable CS
-
Blancett B3000 Explosion-proof Display
-
Model
Blancett B3000 Explosion-proof Display B30
Model
Base, Explosion-proof*, Battery & Loop Power X
Advanced, Explosion-proof*, Battery & Loop Power Z
Mounting
Remote R
Units of Measure
Customer Selectable CS
*For hazardous locations, the monitor must be installed on an explosion-proof rated meter. To maintain compliance, kit P/N B280-737 for meter mounting is required.
DSY-DS-00691-EN-10Page 2 November 2018
Page 3
SPECIFICATIONS
COM
Specications
Display
Power
Inputs
Outputs
Modbus Digital
Communications
Data Configuration
and Protection
Common
Simultaneously shows Rate and Total 5 x 7 Dot Matrix LCD, STN Fluid 6 Digit Rate, 0.5 inch (12.7 mm) numeric
B30A/B/S
7 Digit Total, 0.5 inch (12.7 mm) numeric Engineering Unit Labels 0.34 inch (8.6 mm) 6 Digit Rate, 0.37 inch (9.4 mm) numeric
B30X/Z
7 Digit Total, 0.37 inch (13 mm) numeric Engineering Unit Labels 0.24 inch (6.1 mm)
Annunciators
Alarm 1(1), Alarm 2 (2), Battery Level ( ), RS485 Communications ( Auto switching between internal battery and external loop power; B30A/Z includes isolation between
B30A/B/X/Z
loop power and other I/O Battery 3.6V DC lithium D Cell gives up to 6 years of service life Loop 4…20 mA, two wire, 25 mA limit, reverse polarity protected, 7V DC loop loss
B30S
Internal battery (3.6V DC Nicd) provides up to 30 days of power after 6…8 hours exposure of the integrated photovoltaic cell to direct sunlight
Frequency Range
1…3500 Hz
Frequency
Magnetic Pickup
Measurement Accuracy
Over Voltage Protection
Trigger Sensitivity
±0.1%
28V DC
30 mV
(High) or 60 mV
p-p
(Low) - (selected by circuit board jumper)
p-p
Amplified Pulse Direct connection to amplified signal (pre-amp output from sensor)
Analog 4…20 mA 4…20 mA, two-wire current loop. 25 mA current limit
One pulse for each Least Significant Digit (LSD) increment of the totalizer
Totalizing Pulse
Pulse Type (selected by circuit board jumper)
Maximum Voltage
Maximum Current
Opto-isolated (Iso) open collector transistor
Non-isolated open drain FET
28V DC
100 mA
Capacity Maximum
Output
16 Hz
Frequency Pulse Width 30 mSec fixed
Open collector transistor Adjustable flow rate with programmable dead band and phase.
28V DC
100 mA
Status Alarms B30A/Z
Type
Maximum Voltage
Maximum Current
Pullup Resistor External required (2.2 k Ohm minimum, 10 k Ohm maximum)
Status Alarms
B30B/S/X
None
Modbus RTU over RS485, 127 addressable units / 2-wire network, 9600 baud, long integer and single
B30A/Z
precision IEEE754 formats; retrieve: flow rate, job totalizer, grand totalizer, alarm status and battery level; write: reset job totalizer, reset grand totalizer
B30B/S/X None
Two four-digit user selectable passwords; level one password enables job total reset only, level two
B30A/B/X/Z
password enables all configuration and totalizer reset functions
Not applicable on solar powered units.
)
DSY-DS-00691-EN-10 Page 3 November 2018
Page 4
Specications
B30A/B/S
Safety
B30X/Z
Certifications
Entity Parameters
EMC 2004/108/EC
Measurement
Accuracy
Response Time
(Damping)
Environmental Limits Common Limits –22…158° F (–30…70° C); 0…90% humidity, non-condensing
Materials and
Enclosure Ratings
Engineering Units
Common Accuracy 0.05%
Common Response
Time
B30A/B/S Polycarbonate, stainless steel, polyurethane, thermoplastic elastomer, acrylic; NEMA 4X/IP 66
B30X/Z Copper free, epoxy-coated, aluminum, buna seal, NEMA 4X/IP66
Liquid
Gas
Rate Time Seconds, minutes, hours, days
Totalizer Exponents 0.00, 0.0, x1, x10, x100, x1000
K factor Units Pulses/US gallon, pulses/cubic meter, pulses/liter, pulses/cubic foot
B30A/B only 4…20 mA Loop: Vmax = 28V DC Imax = 26 mA Ci = 0.5 μF Li = 0 mH
B30A/B/S only Pulse Output: Vmax = 28V DC Imax = 100 mA Ci = 0 μF Li = 0 mH
B30A/B/S only Reset Input: Vmax = 5V DC Imax = 5 mA Ci = 0 μF Li = 0 mH
B30A only RS485: Vmax = 10V DC Imax = 60 mA Ci = 0 μF Li = 0 mH
B30A/B/S only Turbine Input: Voc = 2.5V Isc = 1.8 mA Ca = 1.5 μF La = 1.65 H
1…100 seconds response to a step change input, user adjustable
US Gallons, Liters, Oil Barrels (42 US gallons), Liquid Barrels (31.5 US gallons), Cubic Meters, Million US Gallons, Cubic Feet, Million Liters, Acre Feet
Cubic Feet, Thousand Cubic Feet, Million Cubic Feet, Standard Cubic Feet, Actual Cubic Feet, Normal Cubic Meters, Actual Cubic Meters, Liters
Class I Division 1, Groups C, D; Class II, Division 1 Groups E, F, G; Class III for US and Canada. Complies with UL 913 and CSA C22.2 No. 157-92
Class I Division 1 Groups B, C, D; Class II, Division 1, Groups E, F, G; Class III for US and Canada Complies with UL 1203 and CSA C22.2 No. 30-M1986
ATEX II 2 G Ex d IIC T4 Gb and ATEX II D Ex tb IIIC T135 °C Db Complies with Directive 2014/34/EU
DSY-DS-00691-EN-10Page 4 November 2018
Page 5
MOUNTING STYLES
Meter Mount
Monitor is assembled to the flow meter, creating a compact flow measurement system.
NEMA 4X (IP 66) enclosure.
Remote Mount
Ideal when monitor needs to be located away from flow meter. Suitable for high temperature, excessive noise or inaccessible areas.
NEMA 4X (IP 66) enclosure.
Panel, DIN rail, and pipe mounting hardware included.
Cable lengths from 10…100 ft (3…30.5 m) sold separately.
Mounting Styles
Swivel Mount
Capable of adjustment pivot of 180 degrees for ease of viewing.
NEMA 4X (IP 66) enclosure.
Remote Swivel mount also available, consult factory for details.
Offers additional protection from elements.
Explosion Proof
Ideal for hazardous locations.
NEMA 4X (IP 66) enclosure.
Rugged compact design.
Remote or meter mount.
DSY-DS-00691-EN-10 Page 5 November 2018
Page 6
Dimensions
DIMENSIONS
Meter Mount
Remote Mount
A
B
C
A B C
4.50 in. (114.3 mm) 5.08 in. (129.0 mm) 4.78 in. (121.4 mm)
A
C
Explosion Proof
B
A B C
4.50 in. (114.3 mm) 5.08 in. (129.0 mm) 3.80 in. (96.5 mm)
A
B
F
D
E
C
A B C D E F
5.25 in.
(133.4 mm)
5.65 in.
(143.5 mm)
4.86 in.
(123.4 mm)
2.25 in.
(57.1 mm)
3.35 in.
(85.1 mm)
DSY-DS-00691-EN-10Page 6 November 2018
0.33 in.
(8.4 mm)
Page 7
Swivel Mount
Dimensions
A
C
B
D
E
F
A B C D E F
4.50 in. (114.3 mm) 10.9 in. (276.9 mm) 6.90 in. (175.4 mm) 3.21 in. (81.5 mm) 4.25 in. (107.9 mm) 7.00 in. (177.8 mm)
DSY-DS-00691-EN-10 Page 7 November 2018
Page 8
Flow Monitor, B3000 Series
ACCESSORIES
Part Number Description
B280-737 Explosion-proof Meter Mount Kit, 1 in. connections
B280-742 Explosion-proof Meter Mount Kit, 1/2 in. connections
Meter Mounting Kits
Turbine with 1 in. NPT hub size Turbine with 1/2 in. NPT hub size
Control. Manage. Optimize.
Blancett is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specications without notice, except to the extent an outstanding contractual obligation exists. © 2018 Badger Meter, Inc. All rights reserved.
www.badgermeter.com
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882 Europe, Eastern Europe Branch Oce (for Poland, Latvia, Lithuania, Estonia, Ukraine, Belarus) | Badger Meter Europe | ul. Korfantego 6 | 44-193 Knurów | Poland | +48-32-236-8787 Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuen | Germany | +49-7025-9208-0 Europe, Middle East Branch Oce | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Oce #C209 | Dubai / UAE | +971-4-371 2503 Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01 Asia Pacic | Badger Meter | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836 China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412 Switzerland | Badger Meter Swiss AG | Mittelholzerstrasse 8 | 3006 Bern | Switzerland | +41-31-932 01 11 Legacy Document Number: DSY-BR-00089-EN-02