2 of 3
FEATURES
• Interconnect a digital 20/30/60-mA
unipolar Current Loop interface to
an RS-232 interface.
• Units available for active or passive
devices or passive-only devices.
• AC powered or interface powered.
• 220-VAC version of the active/passive
model is available.
• Switches control duplex, loop current,
and operation as either DTE or DCE
devices.
We have the ideal Current Loop solutions
for your point-to-point configuration!
OVERVIEW
The RS-232↔Current Loop Interface Converters are bidirectional, self-contained units that enable you to interconnect a
digital 20/30/60-mA unipolar Current Loop interface to an
RS-232 interface. The converters cannot be used with an
analog Current Loop (4 to 20 mA) or bipolar Current Loop.
AC-Powered Active/Passive and Passive-Only
Converters
These Active/Passive RS-232↔Current Loop Interface
Converters (CL050A-R3, CL050A-E, and CL050-C) use AC power
and act either as active or passive devices on the Current Loop.
As active devices, these converters supply 20-, 30-, or 60-mA
loop current at 18 VDC for operation. As passive devices, the
converters will not supply loop current, but will operate with
20-, 30-, or 60-mA unipolar current at up to 30 VDC.
In contrast, the CL051A RS-232↔Current Loop Interface
Converter operates in passive mode only. It will operate with
60-mA unipolar current at 65 to 130 VDC.
Switch selections enable you to choose half- or full duplex
operation; loop current at 20, 30, or 60 mA; and configuring
the converters as either DTE (data terminal equipment) or DCE
(data communications equipment). Two LEDs monitor data
flow.
RS-232↔ Current Loop
Interface Converter
(CL050A-R3)
5/16/2007
#17068
724-746-5500 blackbox.com
Current Loop
device
Device using
RS-232 interface
Current Loop was designed to transfer data in a noisy
environment with as much integrity as possible. All featured
interface converters include optical isolators in both the
transmit and receive loops to keep out electrical interference.
Note that the maximum calculated distance that any of
these converters or adapters can be placed from other devices
on the Current Loop is based on using 24 AWG and the lowest
data rate.
Technically Speaking
Interface-Powered Passive-Only Converters
For full duplex conversion of RS-232 async data to unipolar
Current Loop, choose an interface-powered converter (CL412AM, CL412A-F).
These units operate as passive devices only, and they must
connect to the active Current Loop. They derive their power
from the RS-232 device, which must provide 12 VDC on pins
6 or 20.
The converters are DTE/DCE selectable. Just flip a switch
on the side of the units to configure them to operate as either
data terminal or data communications equipment.

3 of 3
TECH SPECS
Distance (Maximum) — CL050A-R3, CL050A-E, CL050-C: Up to 9842.5 ft.
(3000 m) at 300 bps over 24 AWG;
CL051A: Up to 2000 ft. (609.6 m) at 9600 bps over 24 AWG
Operation — CL050A-R3, CL050A-E, CL050-C, CL051A: Full or half-duplex;
CL412A-M, CL412A-F: Full duplex
Switches — CL050A-R3, CL050A-E, CL050-C, CL051A:
(1) 10-position DIP switch for Current Loop transmission mode,
(1) 10-position DIP switch for RS-232 DTE or DCE configuration,
(1) 4-screw terminal block for electrical current in the Current Loop
Interface — CL050A-R3, CL050A-E, CL050-C: RS-232 (DTE/DCE switch-
selectable); unipolar 20/30/60 mA at 18 VDC (active) or up to
30 VDC (passive);
CL051A: RS-232 (DTE/DCE) switch-selectable;
unipolar 20/60 mA (passive) up to 130 VDC;
CL412A-M, CL412A-F: RS-232 (DTE/DCE) switch-selectable;
unipolar 20 mA (passive)
Connectors — CL050A-R3, CL050A-E, CL050-C, CL051A, CL412A-F:
RS-232: (1) DB25 F;
Current Loop: (1) 4-screw terminal block;
CL412A-M: RS-232: (1) DB25 M;
Current Loop: (1) 4-screw terminal block
Indicators — CL050A-R3, CL050A-E, CL050-C, CL051A: (1) RX, (1) TX LEDs
for RS-232 port activity;
CL412A-M, CL412A-F: None
Power — CL050A-R3, CL050-C, CL051A: Input: 115 VAC, 60 Hz;
CL050A-E: Input: 220 VAC, 50 Hz;
CL412A-M, CL412A-F: From EIA interface (Pin 6 or 20), +12 VDC from
the RS-232 device
Size — CL050A-R3, CL050A-E, CL050-C, CL051A:
1.75"H (1U) x 5.5"W x 8.5"D (4.4 x 14 x 21.6 cm);
CL412A-M, CL412A-F: 0.6"H x 1.6"W x 2.8"D (1.5 x 4.1 x 7.1 cm)
Weight — CL050A-R3, CL050A-E, CL050-C, CL051A: 1.5 lb. (0.7 kg);
CL412A-M, CL412A-F: 0.2 lb. (0.1 kg)
5/16/2007
#17068
724-746-5500 blackbox.com
✦
(1) RS-232↔Current Loop Interface Converter (232/CL-E)
✦
(1) 6-foot (1.8-m) AT®Modem Cable (EVMBMC-0006)
✦
(1) DB9 Male to DB25 Female AT Adapter (FA521A-R3)
✦
(1) Users’ manual
WHAT‘S INCLUDED (CL050A-R3):
Item Code
RS-232↔Current Loop Interface Converters
Active/Passive
Standalone (115-VAC) CL050A-R3
Standalone (220-VAC) CL050A-E
Rackmount Card (115-VAC) CL050-C
Passive Only
Standalone (115-VAC) CL051A
RS-232↔Current Loop Interface-Powered Converters
Passive Only
Male CL412A-M
Female CL412A-F
To rackmount your CL050-C cards, order…
16-Card Rack RM005
For optimum performance and a 20% savings, order…
Bulk Category 3 Cable, 2-Pair, PVC,
500-ft. (152.4-m) EYN712A-0500
Top: CL412A-M;
bottom: CL050A-R3
Recognize any of these situations?
• You wait more than 30 minutes to get through
to a vendor’s tech support.
• The so-called “tech” can’t help you or gives you
the wrong answer.
• You don’t have a purchase order number and the
tech refuses to help you.
• It’s 9 p. m. and you need help, but your vendor’s
tech support line is closed.
According to a survey by Data Communications
magazine, 90% of network managers surveyed say
that getting the technical support they need is extremely
important when choosing a vendor. But even though
network managers pay anywhere from 10 to 20% of their
overall purchase price for a basic service and support
contract, the technical support and service they receive falls
far short of their expectations— and certainly isn’t worth
what they paid.
At Black Box, we guarantee the best value and the
best support. You can even consult our Technical Support
Experts before you buy if you need help selecting just
the right component for your application.
Don’t waste time and money— call Black Box today.
Why Buy From Black Box? Exceptional Value.
Exceptional Tech Support. Period.