The B&K Precision model 5492B is a versatile
5½-digit, 120,000-count bench multimeter
suitable for applications in education, service
repair, and manufacturing. The instrument
enhances your productivity with built-in math
functions and USB connectivity. Rel, Max/Min,
dBm, dB, %, and Hold functions provide
educators with a convenient tool to teach basic
math concepts. Additionally, the 5492B offers
powerful features not commonly found in other
5½- digit DMMs such as advanced triggering,
buffer storage operation, and a GPIB interface
option.
Increase Productivity with PC Connectivity
The 5492B is programmable via USB, RS232,
and GPIB (5492BGPIB only) interface using
industry standard SCPI commands. Users can
remotely control and configure the instrument
from a PC and retrieve measurement results for
further analysis. The multimeter can also be
remotely controlled using application software
(via USB & RS232), which supports front panel
emulation and data logging of measurement
results.
The 5492B measures volts and amps with great
accuracy and stability, with basic VDC accuracy
of 0.01%. The meter is also capable of measuring frequency, period, resistance, continuity, and
performing diode tests. Readings can be taken at
a maximum rate of 57 readings/sec and stored
to an internal 512-byte buffer for post
acquisition statistical analysis.
The 5492B was designed for cost-conscious
users requiring an accurate meter with a broad
range of features offered at a value price.
The limit operation lets you set and control the
values that determine a HI / IN / LO status of
subsequent measurements. The meter can be
configured to emit an audible alarm when
readings are outside of the configured limit.
Advanced Triggering
A variety of advanced trigger options are
available: Manual Trigger via a front panel button
press, Bus Trigger sending a *TRG command
via PC interface, External Trigger using the EXT
TRIG input terminal on the rear panel.
Additionally, a trigger delay can be programmed
after an event detection, and a VM Comp output
is available to indicate the instrument’s
completion of a present measurement.
Easy operation
▲
Front panel
right VFD display
B
nput banana terminals
I
mA Fuse socketInterface keypadPower button
Fast Buffering with Built-in
Statistics
The 5492B provides an internal buffer capable
of storing up to 512 readings. Buffer storage
operation can be enabled via front panel or
remote command. The buffer fills up with the
requested number of readings at a rate of up to
57 readings/sec and then stops. The instrument
automatically calculates statistical information
based on the stored readings such as minimum,
maximum, or average reading, and standard
deviation, which can then be retrieved along with
the readings via the front panel or remote
command.
Rear panel
Serial number label
Power line
fuse holder
VM Comp
(Voltmeter
complete) BNC
output terminal
GPIB (IEEE-488) interface
(model 5492BGPIB)
External
Trigger BNC
input terminal
RS-232
(Serial) interface
USB interface
Chassis ground
screw terminal
2ww w.b k pr ec is ion .c om
True RMS Bench Multimeter
odel 5492B
M
Specifications
pecifications are based on the following conditions:
S
■ One year calibration cycle
■ Operating temperature between 18 °C to 28 °C
■ Accuracy expressed as: ± (% of reading + % of range) after 30 minutes warm-up and valid for 10 PLC (Slow)
■ Temperature coefficient: add ± [0.1% × (applicable accuracy)/°C] for 0 °C to 18 °C and 28 °C to 40 °C
■ Relative humidity: Up to 80% RH for 0 °C to 28 °C (75% RH for 10 MΩ and above ranges
for resistance measurement), up to 70% RH for 28 °C to 40 °C
DC Voltage
Resolution, Full Scale Reading and Accuracy ± (% of reading + % of range), 23 °C ± 5 °C
Ra ng eRe solu tio n
20.000 mV
1
µV
1
Ful l S c al e
Re a d ing
19.999
1
1.20000 V10 µV1.199990.01+0.004
2.0000 V
1
20.000 V1 mV119.9990.01+0.00410 MΩ ±1%
1
000.00 V
1
1) under REL status
(
00 µV
1
0 mV
1
1.9999
1
010.00
1
(2)
(2) 1% overrange (1010 V) is readable at 1000 V range
Input protection: 1000 V
Ac c urac y
(1 y ear)
.02+0.008
0
.01+0.004
0
.01+0.004
0
(1)
1)
(
Ty p ica l In p ut
Im pe da nce
10 GΩ
>
>10 GΩ
10 GΩ
>
0 MΩ ±1%
1
AC Voltage (True RMS, AC coupled)
Resolution, Full Scale Reading and Accuracy ± (% of reading + % of range), 23 °C ± 5 °C
Ra ngeRe sol u tio n
Fu l l Sca le
Re adi n g
10 -20 Hz20 -50 H z50 -20 kHz20 -50 kHz50 -10 0 k Hz
(1) Specifications are for sine wave inputs >5% of range
(2) ≤ 3×10
7
Volt-Hz for 750 V range
3)
(
1.50+0.1000.50+0.1000.10+0.1000.30+0.150
(3) 1% overrange (757.5V) is readable at 750 V range
Measurement method: AC coupled true RMS, measuring the AC component only
Maximum Crest factor: 3.0 at full scale
Input impedance: 1 MΩ ± 2% in parallel with capacitance <100 pF
Input protection: 750 Vrms, 500 Vdc
(1 )
2)
(
1.0+0.100
DC Current
Resolution, Full Scale Reading and Accuracy ± (% of reading + % of range), 23 °C ± 5 °C
Ra ngeRe solu tio n
Fu l l Sca le
Re adi n g
12.0000 mA0.1 µA11.99990.05+0.008
120.000 mA1 µA119.9990.05+0.004
1.20000 A10 µA1.199990.10+0.004
12.0000 A
(3)
100 µA11.99990.25+0.004
Ac c urac y
(1 y ear )
Bur d en Vo lta ge
& Sh u n t Re sis t o r
(2)
<0.15 V / 10.1 Ω
(2)
<1.5 V / 10.1 Ω
<0.3 V / 0.1 Ω
<0.15 V / 10 mΩ
(1) Typical voltage across the input terminals at full scale reading
(2) Use REL function
(3) In 12 A range, >10~12 ADC is readable for 20 seconds maximum
Input protection: Externally accessible 2A / 250V fuse protecting the low input current terminal (LO).
Internally accessible 20A / 250V fuse protecting the high current input terminal (10A)
(1)
1)
(
3ww w.b k pr ec is ion .c om
True RMS Bench Multimeter
odel 5492B
M
Specifications (cont.)
AC Current (True RMS, AC Coupled)
esolution, Full Scale Reading and Accuracy ± (% of reading + % of range), 23 °C ± 5 °C
R
Ra ngeR eso lut ion
2.0000 mA
1
.20000 A
1
2)
(
12.0000 A
(1) Typical voltage across the input terminals at full scale reading
(2) In 12 A range,>10-12 A AC is readable for 20 seconds maximum
3) Specifications are for sine wave inputs >5% of range
(
easurement method: AC coupled true RMS, measuring the AC component only
M
nput protection: Externally accessible 2 A / 250 V fuse protecting the low input current terminal (LO). Internally accessible 20 A / 250 V fuse protecting the
I
high current input terminal (10A)
ax. crest factor: 3.0 at full scale
M
.1 µA
0
0 µA
1
100 µA11.9999<0.15 V / 10 mΩ1.0+0.0800.50+0.0800.25+0.0802.0+0.080
Ful l S ca le
Re a ding
1.9999
1
.19999
1
Bu rde n Volta g e
& Shun t R esis t o r
0.15 V / 10.1 Ω
<
0.3 V / 0.1 Ω
<
Resistance (2-Wire and 4-Wire)
esolution, Full Scale Reading and Accuracy ± (% of reading + % of range), 23 °C ± 5 °C
R
(1)
Ra n g e
120.000 Ω1 mΩ119.9991 mA0.05 +0.008
1.20000 kΩ10 mΩ1.199991 mA0.03 +0.004
12.0000 kΩ100 mΩ11.9999100 µA0.03 +0.004
120.000 kΩ1 Ω119.99910 µA0.03 +0.004
1.20000 MΩ10 Ω1.1999910 µA0.03 +0.004
12.0000 MΩ100 Ω11.99997.0/(10M+Rx) µA0.10 +0.004
120.000 MΩ1 kΩ119.9997.0/(10M+Rx) µA0.50 +0.008
(1) In order to eliminate the noise interference, which might be induced to the test leads, it is recommended to use a
shielded test cable for measuring resistance above 120 kΩ
(2) Using REL function
Input protection: 1000 Vdc or 750 Vac for all ranges
Note: Rx is the measured resistance value
Re sol u tio nFull Sc al e Re adi n gTes t C urr e n t
(1 )
10 -20 H z20 -50 H z50-2 kHz2- 20 kH z
.0+0.080
1
.0+0.080
1
Accu r ac y
(1 yea r )
Ac curac y (1 yea r)
.50+0.080
0
.50+0.080
0
2)
(
2)
(
(2)
.25+0.080
0
.25+0.080
0
(3)
.0+0.080
2
.0+0.080
2
Continuity
Resolution, Full Scale Reading and Accuracy ± (% of reading + % of range), 23 °C ± 5 °C
Ra ngeRe solu t ion
1 kΩ100 mΩ999.91 mA0.1%+0.02%
For 0.1 PLC (Fast)
Input protection: 1000 Vdc or 750 Vac
Ful l S c al e
Re a d ing
Tes t C urr e n t
Accu r ac y
(1 yea r )
Diode
Resolution, Full Scale Reading and Accuracy ± (% of reading + % of range), 23 °C ± 5 °C
Ran g eResol uti o n
3.0000 V100 µV2.99991 mA0.030+0.020
10.0000 V100 µV10.0000100 µA0.030+0.020
10.0000 V100 µV10.000010 µA0.030+0.020
For 1 PLC (Medium)
Input protection: 1000 Vdc or 750 Vac for all ranges
Fu l l Sca le
Rea d ing
Te st C u r ren t
4ww w.b k pr ec is ion .c om
Ac c urac y
(1 y ear)
True RMS Bench Multimeter
odel 5492B
M
Specifications (cont.)
Frequency
esolution, Full Scale Reading and Accuracy ± (% of reading + % of range), 23 °C ± 5 °C
R
ACV
Ra nge
00 mV
1
750 V
(1) If testing frequency is greater than 1MHz, it will be displayed but no specified accuracy is guaranteed.
(2) Specified accuracy at input >5 % of range.
Gate Time at 1 Sec.
Input protection: 750 Vrms or 500 Vdc
Fr e quen c y R ang eRes o luti on
5 ~ 10 Hz10 µHz9.999990.05200 mVrms
o
t
10 ~ 100Hz100 µHz99.99990.0140 mVrms
00 ~ 100 kHz
1
100 k ~ 1 MHz
(
1 Hz999.9990.005100 mVrms
mHz
1
1)
Period
Resolution, Full Scale Reading and Accuracy ± (% of reading + % of range), 23 °C ± 5 °C
AC V Rang ePe rio d Ran geR e s olut i on
(1)
~ 10 µs
00 mV
1
to
750 V
(1) If testing frequency is greater than 1MHz, it will be displayed but no specified accuracy is guaranteed.
(2) Specified accuracy at input >5 % of range.
Gate Time at 1 Sec.
Input protection: 750 Vrms or 500 Vdc
1
10 µs ~ 10 ms0.1 ns9.999990.00540 mVrms
10 ms ~ 100 ms0.1 µs99.99990.0140 mVrms
100 ms ~ 200 ms1 µs199.9990.05200 mVrms
.01 ns
0
Fu l l Sca le
Re adi n g
99.999
9
Fu l l Sca le
Re adi n g
.99999
9
Ac c urac y
0
Ac c urac y
.005
0
.005
In p ut Sensi tiv i ty
(2 )
(S ine Wav e )
Inp ut Sens i tiv ity
(2 )
0 mVrms
4
(S i n e Wa ve)
00 mVrms
1
Supplemental
Environmental
Op erati n g Env iro n men t
St ora ge En viro n m ent
Hu mid i ty
General
Re m o te Inte r faces
Me a surem e nt Ca teg o ry
Ma th Func tio n s
AC Inp ut
Po we r Co nsu m ptio n
Sa fet y & EMC
Di m ensi ons (W× H×D)
Ne t Wei g h t
Inc lud ed Acce s sor ies
0 °C to 40 °C, 32 ºF to 104 ºF
-40 °C to 70 °C -40 ºF to 158 ºF
≤ 90 %RH
RS232, USB (virtual COM) GPIB (model 5492BGPIB only)