BK Precision 5105 Data Sheet

48
200 MS/s Digital Storage Oscilloscope
These digital scopes store waveforms in memory. For one-shot events, you can see what happened before the trigger. You can store up to two waveforms, each 2kx8 bit long. After acquisition, the data can be manipulated and displayed in many different ways. You can change time base or vertical position. You can select which portion of a wave­form you’d like to look at in more depth. You can compare the measured waveform to a “known-good” waveform in memory. Additionally, Model 5105A incorporate glitch capture to see signals that otherwise would not be seen. You can interpolate or smooth the wave form to “fill in the gaps.”
Simply selected by pressing the auto measurement button, these 17 different amplitude and time related functions are available to make automatic calculations on digitized stored waveforms.
events. ENVELOPE MODE (pictured center): Each sweep of a repetitive signal accumulates on the screen, building up an envelope view of the signal variations.
5105A
T= 1/F
W+ W-
Vh
Vamp
Vlow
Vmin
Vpp
Vmax
tr tf
10 0 %
90%
50%
10 %
0%
Selectable acquisition modes
REFRESH:Trace is updated left to right.
Display may show only part of record
ROLL: adds new sample to right side of display. Display always
shows what’s changing. Useful for slow moving signals.
SINGLE to store one shot event for analysis
PRETRIG to see what happened before the trigger
ENVELOPE to see how signal fluctuates
On-CRT readout for ease of use.Works in both analog
and digital mode.
Set cursors or have scope automatically take measurements
Linear, sinusoidal interpolation: Fills in digital dots between
two samples. Good for digital expansion.
Analog smoothing: Fills gap in an analog manner between
two adjacent display dots.
For your nearest distributor, call 800-462-9832 or www.bkprecision.com
49
VERTICAL DEFLECTION
OPERATING MODES Channel I or II separate
both Channels (alternated or chopped) CHOPPER FREQUENCY approx. 0.5MHz SUM OR DIFFERENCE from CH I and CH II INVERT CH I and CH II XY-MODE via channel I (Y) and channel II (X) FREQUENCY RANGE DC to 150MHz (-3dB) RISETIME <2.3ns OVERSHOOT 1 % DEFLECTION COEFFICIENT 14 calibrated positions from 1mV/div to 20V/div in
1-2-5 sequence, variable 2.5:1 to min. 50V/div.
ACCURACY IN CALIBRATED POSITIONS
1mV/DIV - 2mV/DIV ±5% (DC - 10MHz (3dB)) 5mV/DIV - 20V/DIV ±3% INPUT IMPEDANCE 1MIl 15pF INPUT COUPLING DC-AC-GD (ground) INPUT VOLTAGE max. 400V (DC + peak AC) DELAY LINE aporox. 70ns
TRIGGERING
AUTOMATIC (PEAK TO PEAK) 20Hz - 250MHz (0.5div.) NORMAL WITH LEVEL CONTROL DC - 250MHz (≥ 0.5div.) INDICATOR FOR TRIGGER ACTION
LED SLOPE positive or negative SOURCES Channel I or II, line and external ALT. TRIGGERING CH I/CH II (≥ 0.8div.) COUPLING AC (10 - 250MHz) DC (0 - 250MHz) HF (50kHz - 250MHz) LF (0 - 1.5kHz) NR (Noise reject) 0 - 50MHz (≥ 0~8div.) TRIGGERING TIME BASE B normal with evel control and slope selection
(0 - 250MHz) EXTERNAL 0.3Vpp (0 - 250MHz) ACTIVE TV SYNC. SEPARATOR field & line, + / -
HORIZONTAL DEFLECTION
ANALOG TIME BASE Accuracy in calibr. position 3%; 1-2-5 sequence A 0.5s - 50ns/div. B 20ms - 50ns/div. OPERATING MODES A or B, alternate A/B VARIABLE 2.5:1 up to 1.25s/div. X-MAG. x10 (±5%) max. 5ns/div. HOLDOFF TIME variable to approx. 10:1 BANDWIDTH X-AMPLIFLER 0 - 3MHz (-3dB) X-Y PHASE SHIFT <3° below 220kHz
DIGITAL TIME BASE
ACCURACY 3%, 1-2-5 sequence A 100s - 0.1µs/div. B 20ms - 0.1µs/div. OPERATING MODES A or B, alternate A/B X-MAG. x10 (±5%) 10ns/div. BANDWIDTH X-AMPLIFIER 0 - 20MHz (-3dB) X-Y PHASE SHIFT <3° below 20MHz INPUT X-AMPLIFIER via Channel II SENSITIVITY see CH II
DIGITAL STORAGE
OPERATING MODES Refresh, Roll, Single, XY Average
(2 to 512 waveforms), Envelope DOT JOIN FUNCTION automatically ACQUISITION (REAL TIME) 8 BIT FLASH A/D max. 200MS/s DISPLAY REFRESH RATE max. 180/s MEMORY & DISPLAY 2k x 8bit per channel REFERENCE MEMORY 2 waveforms 2k x 8bit SAVED IN (EEPROM) RESOLUTION (SAMPLES/DIV.) X 200/div.
Y 25/div.
XY 25 x 25/div. PRE-/POST TRIGGER 25,50,75,100, -25,-50, -75%
OPERATION / CONTROL
MANUAL front panel switches Auto Set signal related automatic parameter selection SAVE & RECALL 9 user defined parameter settings
READOUT & CURSOR (ANALOG/DIGITAL)
Display of parameter settings and other functions on the screen. Triggerpoint indication. Cursor measurement of ∆U, ∆t or 1/t (frequency), separate or in tracking mooe.
READOUT INTENSITY separately adjustable
INTERFACE
PC REMOTE CONTROL built-in RS232 intertace
COMPONENT TESTER
TEST VOLTAGE max. 7Vrms (o/c) TEST CURRENT max. 7mArms (s/c) TEST FREQUENCY approx. 50Hz
One test lead is grounded (Safety Earth)
GENERAL INFORMATION CRT D14-375GY, 8 x 10cm internal graticule
ACCELERATION VOLTAGE approx. 14kV TRACE ROTATION adiustable on front panel CALIBRATOR 0.2V ±1%, 1kHz/1MHz (tr <4ns)
LINE VOLTAGE 100 - 240V AC ±10%, 50/60Hz POWER CONSUMPTION approx. 42 Watt as 50Hz MIN./MAX. AMBIENT TEMPERATURE 32˚ TO 104˚F (0˚C + 40°C) PROTECTIVE SYSTEM Safety class II EC1010-1 WEIGHT approx. 12.4 lbs. ( 6.5 kg) COLOR techno brown DIMENSIONS (W x H x D) 11.6 x 4.9 x 15.0" (295 x 125 x 380 mm)
Lockable tilt handle
SUPPLIED: Operating Manual, 4 Disks, Line Cord, 2 Probes 10:1 OPTION­AL: PR-150 Low Capacitance Probe, PR-2000 High Voltage Probe,
PR-60 Active Differential Probe, CC-21 BNC Cable to Alligator Clips, LC-210A Carrying Case
Specifications
model
5105A
Accessories
Two Year Warranty
Loading...