300
Type Analog Analog Analog Digital Output Voltage 1000VDC 500VDC 1000VDC 1000VDC Maximum current 250µA 500µA 2mA 1.2mA Resistance Range 1MΩ -2000MΩ 0.2MΩ - 1000 MΩ 1000V 0-200M 0-2000M
500V 0-100M 0-2000MΩ 250V 0-50M 0-2000MΩ
Infinity: within 1% of scale length
Zero: within 1% of scale length
All points ±5% of reading
AC Voltage Test Range 0 to 600 VDC Live Circuit Indicator Frequency Response 10Hz to 100kHz Accuracy ±4% of full scale Low resistance Test Does not apply 0-50 0-200Ω Accuracy Does not apply ±5% of reading ±(1.5% + 2 digits) General Specifications Power Requirements Six “AA” cells (supplied) Eight “AA” cells (supplied) Battery Life 4 hours typical alkaline 12 hours continuous 10 hours continuous w/alkaline Operating Temperature 32˚ to 122˚F (0˚ to 50˚C), 70% RH Storage Temperature -4˚ to 140˚F (-20˚ to 60˚C), <80% RH (with batteries removed) Dimensions 6.66 x 4.18 x 1.42" (169 x 106 x 36mm) 7 x 8.5 x 3.5" (180 x 220 x 90mm) Weight 15oz. (430g) w/batteries 2.6 lb (925g) with batteries
250V 500V 1000V
0-100 ±(1.5%+3D) ±(1.5%+2D) ±(1.5%+2D) 100-200M ±(2%+5D) ±(1.5%+2D) ±(1.5%+2D) 200-1700M±(3%+7D) ±(3%+4D) ±(3%+3D) 1700-2000M±(4%+8D) ±(4%+6D) ±(4%+5D)
Models 300, 305
These insulation testers are intended primarily for periodic testing of industrial motors, transformers, electrical wiring, and cable insulation for signs of deteri­oration. Low readings may indicate impending failure and permit replacement during routine maintenance rather than risking production downtime. Also useful for safety testing of TV sets and appliances to assure no hazardous leakage current. The voltage and resistance ratings for insulation testing are often specified for the product to be tested.
Supplied: Batteries, Carrying Case, Test Leads, Instruction Manual Batteries, Integral Carrying Case w/strap, Test Lead, Instruction Manual
Specifications
models
300 305 307 308
Models 307, 308
Selectable 250V, 500V, or 1000V insulation test
Low resistance test
Extra rugged integral carrying case
Live circuit indicator warns of safety hazard
Push to test
Test insulation resistance
Measure AC voltage to 600V
Battery powered
1000V, 2000M(Model 300)
500V, 1000M(Model 305)
One Year Warranty
307