BK Precision 2704C Data Sheet

34
2707A2708
Basic Functions
Ranging Auto Manual Manual Manual Manual Current 10A AC/DC 10A AC/DC 10A AC/DC 10A AC/DC 10A DC
Component Tests
Resistance 0.1to 43M 0.1to 200M0.1to 20M0.1to 20M0.1to 20M Capacitance to 20µF to 20µF to 20µF
Common Features:
2000 count
0.5% DCV accuracy
DC voltage to 1000V
AC voltage to 750V
DC current to 10A
Continuity
Diode test
Drop resistant case
Features
models
2708 2707A 2706A 2704B 2703B
Excellent meters for most jobs that require flexibility, accu­racy and speed. Value packed features make these meters a must in every “Tool Kit®.”
DC Volts
Ranges 430mV, 4.3V, 43V, 1000V 200mV, 2V, 20V, 200V, 1000V Resolution 100µV, 1mV, 10mV, 100mV, 1V Accuracy ±(0.5% + 1 Digit) Overload Protection 200mV Range 500V DC + AC Peak, 350V RMS Sine: All Other Ranges: 1200V DC + AC Peak, 800V RMS, Sine Input Impedance 10M
AC Volts
Ranges 430mV, 4.3V, 43V, 430V, 750V 200mV, 2V, 20V, 200V, 750V 200V, 750V, Resolution 100µV, 1mV, 10mV, 100mV, 1V 100µV, 1mV, 10mV, 100mV, 1V 100mV, 1V Basic Accuracy ±(1.5% + 4 Digits) Frequency Response 50 to 100 Hz 50 to 500 Hz Overload Protection 200mV Range: 500V DC + AC Peak, 350V RMS, Sine: All Other Ranges: 1200V DC + AC Peak, 800V RMS, Sine: 500VDC + AC Peak,
750VRMS, Sine
Input Impedance 10M 4.5M
DC Current
Ranges 430µA, 43mA, 430mA, 10A 200µA, 2mA, 20mA, 200mA, 2A, 10A (2A: 2706A only) 200mA, 20mA, 200mA, 10A Resolution 0.1µA, 10µA, 100µA, 10mA 0.1µA, 1µA, 10µA, 100µA, 1mA, 10mA (1mA: 2706A only) 0.1µA, 1µA, 100µA, 10mA Accuracy ±(0.5% + 1 Digit) ±(1% + 1 Digit): 10A Range: ±(2% + 3 Digits) Burden Voltage 10A and 200mA range: 750mV max.; All Other Ranges: 325mV max. Overload Protection 10A Range: Unfused; All Other Ranges: 250V Fuse
AC Current
Ranges 430µA, 43mA, 430mA, 10A 200µA, 2mA, 20mA, 200mA, 2A, 10A (2A: 2706A only) Does not apply Resolution 0.1µA, 10µA, 100µA, 10mA 0.1µA, 1µA, 10µA, 100µA, 1mA, 10mA (1mA: 2706A only) Accuracy ±(1.2% + 4 Digits): 10A Range: ±(2% + 4 Digits) Frequency Response 50 to 500 Hz Burden Voltage 10A and 200mA Range: 750mV max.; All Other Ranges: 325mV max. Overload Protection 10A Range: Unfused; All Other Ranges: 250 V Fuse
Resistance
Ranges 430, 4.3k, 43k, 4.3M, 43M200, 2k, 20k, 200k, 2M, 20M, 200M(200M: 2707A only) Resolution 0.1, 1, 10, 100, 1k, 10k 0.1, 1, 10, 100, 1k, 10k, 100k(100kΩ: 2707A only) Basic Accuracy 430Ω Range: ±(0.3% + 3 Digit)
200MΩ Range (2707A only): ±(5% + 10 Dgt.);
±(0.8% + 1 Digit)
4.3k - 4.3MΩ Range: ±(0.3% + 2dgt) 20MΩ Range: ±(3% + 1 Digit) 43MΩ Range: ±(1.5% + 4 Digit) 200Ω Range: ±(1% + 3 D)
Overload Protection 500V DC + AC Peak
Specifications
models
2708 2707A 2706A 2704B 2703B
For your nearest distributor, call 800-462-9832 or www.bkprecision.com
35
2706A
2703B
2704B
One Year Warranty
Diode Test Tested at 1.6mA and 3.2V Max. Transistor Test (hFE) Does not apply Base Current: 10µA Vce; 2.8V; Gain Indication: 0 to 1,000 Does not apply Capacitance
Ranges Does not apply 2,000pF, 20nF, 200nF, 2µF, 20µF Does not apply Resolution 1pF, 10pF, 100pF, 1nF, 10nF Accuracy ±(3% + 10 Digits) Test Frequency, Voltage 400Hz, 50mV
Frequency
Ranges Does not apply 2kHz, 20kHz, 200kHz, 2MHz, 15MHz Does not apply Resolution 1Hz, 10Hz, 100Hz, 1KHz, 10KHz Accuracy ±(0.1% + 2 Digit) Sensitivity 1Vrms Overload Protection 500V DC + AC Peak
Logic Probe (TTL)
Logic Threshold 1 = 2.8 ± 0.8V, Does not apply Does not apply Does not apply
0 = 0.8 ± 0.5V
Minimum Pulse Width 25nS Input Impedance 120kΩ nom. Overload Protection 500V DC + AC Peak
Temperature
Range Does not apply Does not apply -4° to + 1400°F Does not apply Does not apply
(-20° to + 750°C)
Accuracy
-4° to + 900°F ±(2% + 4°F) (-20° to 500°C) ±(2% + 2°C) 900° to + 1400°F ±(3% + 4°F)
(500° to + 750°C) ±(3% + 2°C) Continuity Tone Tone Sounds within 100mS for Resistance Under 100V General
Display 3 1/2 digit, high-contrast 0.7" LCD, 1999 counts Sampling 3 times/sec. (nominal) Operating Temp: 32° to 104°F (0° to + 40°C), 0 to 70% RH Storage Temp -4° to 140°F (-20° to + 60°C), 0 to 80% RH Power Requirements 9 Volt NEDA 1604. Battery Life 200 hours (alkaline) nominal 275 hours (alkaline) Nominal (2703B only) Dimensions (HxWxD) 5.9 x 3.1 x 1.3" (150 x 79 x 33 mm) Weight 9 oz. (250g) with batter y
Specifications (continued)
models
2708 2707A 2706A 2704B 2703B
SUPPLIED:Battery, Test Leads, Instruction Manual.Thermocouple Probe (2706A only) OPTIONAL:TL-2A Deluxe Test Leads, TL-3 Accessory Tip Kit (for TL-2A), PR-28A High Voltage DMM Probe (40kVDC),
TL-130A General Purpose DMM Kit
Carrying Case (not included): LC-29B
Accessories
See previous page
Loading...