B&K IR80 User Manual

B&K Components, Ltd.
IR80
IR Distribution Module
User Manual
14193 051607
User Manual - IR80 © 2007 B&K Components Ltd. All rights reserved.
The information in this manual is copyright protected. No part of this manual may be copied or reproduced in any form without prior written consent from B&K Components, Ltd. B&K Components Ltd. SHALL NOT B E LIABLE FOR OPERATIONAL, TECHNICAL OR EDITORIAL ERRORS/OMISSIONS MADE IN THIS MANUAL. The information in this manual is subject to change without prior notice.
Limited Warranty B&K Components Ltd., referred to herein as B&K, warr ants your B&K equipment against all defects in material and workmanship for a period of five years from the date of purchase. This warranty applies only to the original purchaser and only to equipment in normal residential us e and service. Defective equipment must be returned to B&K, prepaid , accompanied by proof of purchase and sufficient payment to cover the cost of return shipping and handling, and will be repaired or replaced at the discretion of B&K whose decision as to the method of reparation will be final.
This warranty shall not apply to any equipment which is found to have been impro perly installed, incorrectly fused, misused, abused, or sub­jected to harmful elements, used in any way not in accordanc e with instructions supplied with the unit, or to have been modified, repaired or altered in any way without the expressed, written consent of B& K. This warranty does not apply to the cabinet or appearance items such as the faceplate or control buttons, nor does it cover any expenses in curred in shipping the unit to and from the manufacturer's service department.
This warranty on B&K Components, Ltd. products is NOT VALID if the products hav e been purchased from an unauthorized dealer or an E­tailer or if the original factory serial number has been remov ed, defaced or replaced in any way. B&K Components, Ltd. sells its products through authorized dealers in order to ensure that consumers obtain proper dealer service and support. Buying from an authorized B&K Components, Ltd. dealer insures that you have a FACTORY WARRANTY on your B&K Compone nts, Ltd. product. If you have any questions concerning your Factory Warranty call B&K Components, Ltd. at 716-656-0026.
THE EXPRESS FACTO RY WARRANTY HEREIN CONTAI NED IS IN LIEU OF ANY AND ALL OTHE R WARRANTIES, EXPRESSED OR IMPLIED, INCLUDI NG ANY WARRANTY OF MERCHANT ABILITY, UPGRADEABILITY OR OF FITNESS FOR ANY PARTICULA R PUR­POSE. B&K COMPONENTS, LTD. SHALL NOT UNDER ANY CIRCUMSTANCES BE LIABLE FOR DAMAGES, INCLUDING SPECIAL, INCIDENTAL, EXE MPLARY, PUNITIVE OR CONSEQ UENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH TH E PURCHASE, USE OR PERFORMANCE OF ANY B&K PRODUCT.
This warranty gives you specific legal rights. You may also hav e other rights which vary from State to State. Some States do not allow the exclusion or limitation of incidental or consequential dam ages and the foregoing exclusions may not apply to you. No agent, representative, dealer or employee of B&K has the authority to increase or alter the o bligations or terms of this warranty.
Returning Equipment No equipment may be returned to B&K Components Ltd. witho ut a RETURN AUTHORIZATION (RA). Should you find it necessary to return equipment to B&K, for any reason, a RETURN AUTHORIZATION (RA) number mu st be issued by B&K in respect to the equipment being returned. You may request an RA number by calling B&K at th e numbers below. We will need the following information to issue your RA number. Please have it ready before you call.
1. Your name, address, and phone number.
2. The model and serial number of the equipment being returned.
3. A description of the problem being experienced.
4. Your sales receipt.
Your call will be referred to a Technical Service Representat ive who will work with you to resolve the problem. If it is determined that the unit must be returned for repair, an RA number will be issued.
SIMPLY BETTER! is a registered trademark of B&K Compon ents, Ltd.
Accessories Included 1– Users Manual 4– Felt Feet
The IR80 is a device that accepts an infrared signal from a B&K keypad or an external control receiver and sends the received signal out eight 3.5mm mono outputs simultaneously. This device may also be slaved to another IR80, which will provide another eight infrared outputs. The IR80 is typically used to provide multiple infrared outputs to control preamplifiers, receivers and source pieces within a single installation.
1. Dual Box and Decora Chassis Configuration - The IR80 is shipped default as a floor box design (F) for use on a shelf, mounting behind a rack or even next to the source. The IR80 may be configured for use in a decora wall plate by removing the screws of the chassis and extracting the decora module assembly.
2. Input— RJ45 CAT-5 input from a CK 1.1 keypad, CK 1.2 keypad or other IR80 module. The conversion module uses this input as the source of IR to be sent to the 8 IR Outputs. Maximum length of CAT-5 run should be no longer than 500 feet total when powering the IR80 and/or keypad from the CT Receiver or 1,000 feet total when powering the IR80 and/or keypad with an external power source.
3. Pass-Thru—RJ45 CAT-5 pass through that will send the Input signal (see 2.) to another IR80 distribution module, CK 1.2 keypad or CK 1.1 keypad.
4. Phoenix Input—Three-position phoenix adaptor for an +12VDC , DATA IN and grou nd. When external power is needed the ground and +12VDC would be connected to power the IR80.
5. Eight Flasher Outputs—Eight flasher outputs are available for sending IR information to source pieces, preamplifiers, receivers, etc. All eight flashers would send infrared information simultaneously from the RJ45 CAT-5 input or the IN on the 3 -position ph oenix adapter.
Input
RJ45 CAT-5 Input from a CK 1.1 keypad, CK 1.2 keypad or other IR80 module. The conver­sion module uses this input as the source of IR to be sent to the eight 3.5mm IR Outputs. Maximum length of CAT-5 run should be no longer than 1,000 feet. When using with another IR80 module, CK 1.2 or CK 1.1 keypad the total length of run for all devices can be no longer than 1,000 feet.
Pass-Thru
RJ45 CAT-5 pass through that will send the Input signal (see above) to another IR80 distribu­tion module, CK 1.2 keypad or CK 1.1 keypad.
Phoenix Input
Three-posit ion phoenix adaptor for an +12 VDC, IN and ground. When external power is needed th e ground and +12VDC would be connected to power the IR80..
Front Panel Decora and Box Summary
Eight Flasher Outputs
Eight flasher outputs are available for sending IR information to source pieces, preamplifiers, receivers, etc. All eight flashers would send infrared information simultaneously from the RJ45 CAT-5 inp ut or the IN on th e 3-position phoenix adapt er.
Rear Panel Decora and Box Configuration Summary
CAT5 Audio/Video Drive Pinout
CAT-5 RJ45 pinouts use the T568B standard. See the figure at left. Pins 1 and 3 send power for up to 500 feet. Use of other CAT-5 connection stan­dards may result in increased signal degradation.
The IR 80 has a maximum length of CAT-5 that should be no longer than 500 feet total when powering the IR80 and/or keypad from the CT Receiver or 1,000 feet total when powering the IR80 and/or keypad with an external power supply.
CAT-5 T568B Standard
The IR80 module accepts an infrared signal from a B&K Keypad and sends a received signal out to eight 3.5mm mono outputs simultaneously (note: identical sources with the same IR identification code can not be controlled independently). Shown below is an IR80 connected to the Zone Control I/O on a CT Receiver. Then the CK 1.2 keypad is connected to the pass-thru input on the IR80 module. This allows for keypad to control the local sources through the IR80 module, while still allowing for a pass through to the CT Receiver.
Connection to a CK 1.2 keypad and CT Receiver
1.
CK 1.2 Keypad
IR80 Module
CT Zone Control I/O
Local Source #1
Local Source #2
Local Source #3
The IR80 module is a flexible IR distribution system that can be used in many situations. Shown below is an example of the IR80 module used to provide multiple IR outputs to control preamplifiers, receivers and source pieces within an installation.
Connection as a standalone IR distribution module
IR80 Module
IR Receiver
To External Power
2.
3.
4.
5.
Loading...