OIL FILL QUANTITY/TYPE .................................................................................................................................................... 7
POSITIONING THE PUMP .................................................................................................................................................... 8
PUMP WILL NOT RUN ........................................................................................................................................................ 14
PUMP RUNS BUT DOES NOT DELIVER RATED CAPACITY ........................................................................................... 14
SERVICING YOUR SUBMERSIBLE PUMP ........................................................................................................................ 14
MAINTAINING YOUR PUMP ............................................................................................................................................... 14
CHANGING SEAL OIL ......................................................................................................................................................... 15
EXPLODED VIEW OF JX22SS-F, JX37SS-F (PRECISION CAST MODELS) ......................................................................... 22
J-F SERIES PARTS LIST ......................................................................................................................................................... 23
JX-F SERIES PARTS LIST ....................................................................................................................................................... 25
THREE PHASE WIRING DIAGRAM ......................................................................................................................................... 27
SEAL MINDER® - THERMAL MOTOR SENSOR SWITCH ...................................................................................................... 31
WARRANTY AND LIMITATION OF LIABILITY ........................................................................................................................ 33
START-UP REPORT FORM .................................................................................................................................................... 34
This Installation, Operation and Maintenance manual provides important information on safety
and the proper inspection, disassembly, reassembly and testing of the BJM Pumps® J-F & JXF Series submersible pump. This manual also contains information to optimize performance
and longevity of your BJM Pumps submersible pump. The F Series FARHRENHEIT™ pumps
are engineered to pump water based liquids up to 200° Fahrenheit (93°C).
The submersible J-F Series pumps are designed to pump water and wastewater. The
JX-F Series pumps are designed to pump corrosive liquids in concentrations
chemically compatible with 316SS and FKM. The J-F & JX-F Series pumps are not
explosion proof. They are not designed to pump volatile or flammable liquids.
Note: Consult chemical resistance chart for compatibility between pump materials and
liquid before operating pump. Consult BJM engineering if there is a question on
chemical compatibility.
If you have any questions regarding the inspection, disassembly, assembly or testing please
contact your BJM Pumps distributor, or BJM Pumps, LLC.
BJM Pumps, LLC
123 Spencer Plain Rd.
Old Saybrook, CT 06475, USA
Information, including pump data sheets and performance curves, is also available on
our web site: HHUUwww.bjmpumps.comUU
For assistance with your electric power source, please contact a certified electrician.
Please pay attention to the following alert notifications. They are used to notify
operators and maintenance personnel to pay special attention to procedures, to avoid
causing damage to the equipment, and to avoid situations that could be dangerous to
personnel.
NOTE: Instructions to aid in installation, operation, and maintenance or which
clarify a procedure.
Immediate hazards that WILL result in severe personal injury or
death. These instructions describe the procedure required and the injury which will
result from failure to follow the procedure.
Hazards or unsafe practices that COULD result in severe personal
injury or death. These instructions describe the procedure required, and the injury which
could result from failure to follow the procedure.
Hazards or unsafe practices which COULD result in personal injury
or product or property damage. These instructions describe the procedure required and
the possible damage which could result from failure to follow the procedure.
5
SAFETY
Pump installations are seldom identical. Each installation and application can vary due
to many different factors. It is the owner/service mechanics responsibility to repair,
service, and test to ensure that the pump integrity is not compromised according to this
manual.
Risk of electric shock – this pump has not been investigated for use
in swimming pool areas.
Do not pump flammable or volatile liquids. UUDeath or serious
injury will result.
Before attempting to open or service the pump:
1) Familiarize yourself with this manual.
2) Unplug or disconnect the pump power cable to ensure that the pump will remain
inoperative.
3) Allow the pump to cool if overheated.
Do not operate the pump with a worn or damaged electric power
cable. Death or serious injury could occur.
Never attempt to alter the length or repair any power cable with a
splice. The pump motor and pump motor and cable must be completely waterproof.
Damage to the pump or personal injury may result from alterations.
After the pump has been installed, make sure that the pump and all
piping are secure before operation.
Do not lift the pump by the power cable piping or discharge hose.
Attach proper lifting equipment to the lifting handle (or lifting rings) fitted to the pump. Do
not suspend the pump by the power cable.
Obtain the services of a qualified electrician to troubleshoot, test
and/or service the electrical components of this pump.
Pumps and related equipment must be installed and operated
according to all national, local and industry standards.
6
INSPECTION
Review all safety information before servicing pump.
The following are recommended installation practices/procedures for the pump. If there
are questions in regards to your specific application, contact your local BJM Pumps
distributor or BJM Pumps, LLC.
PRE-INSTALLATION INSPECTION
1) Check the pump for damage that may have occurred during shipment.
2) Inspect the pump for any cracks, dents, damaged threads, etc.
3) Check power cord and sensor cable for any cuts or damage.
4) Check for, and tighten any hardware that appears loose.
5) Carefully read all tags, decals and markings on the pump.
If anything appears to be abnormal, contact your BJM Pumps distributor or BJM
Pumps, LLC. If damaged, the pump may need to be repaired before use. Do not install
or use the pump until appropriate action has been taken.
LUBRICATION:
No additional lubrication is necessary. The shaft seal and bearings are fully lubricated
from the factory. Seal oil should be checked once per year. See table on page 7.
7
Qty. oil in seal chamber
Models
U.S. fl. oz.
C.C.
Type of oil
J08-F
9
265
ISO 32 NSF Food Grade Mineral Oil
J15-F
9
265
ISO 32 NSF Food Grade Mineral Oil
J22-F
10.8
320
ISO 32 NSF Food Grade Mineral Oil
J37-F
10.8
320
ISO 32 NSF Food Grade Mineral Oil
J55C-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
J75C-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
Qty. oil in seal chamber
Models
U.S. fl. oz.
C.C.
U.S. fl. oz.
J08H-F
9
265
ISO 32 NSF Food Grade Mineral Oil
J15H-F
9
265
ISO 32 NSF Food Grade Mineral Oil
J22H-F
10.8
320
ISO 32 NSF Food Grade Mineral Oil
J37H-F
10.8
320
ISO 32 NSF Food Grade Mineral Oil
J55CH-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
J75CH-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
Qty. oil in seal chamber
Models
U.S. fl. oz.
C.C.
Type of oil
JX08SS-F
10.1
300
ISO 32 NSF Food Grade Mineral Oil
JX15SS-F
10.1
300
ISO 32 NSF Food Grade Mineral Oil
JX22SS-F
13.5
400
ISO 32 NSF Food Grade Mineral Oil
JX37SS-F
13.5
400
ISO 32 NSF Food Grade Mineral Oil
JX55CSS-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
JX75CSS-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
Qty. oil in seal chamber
Models
U.S. fl. oz.
C.C.
Type of oil
J08HSS-F
10.1
300
ISO 32 NSF Food Grade Mineral Oil
JX15HSS-F
10.1
300
ISO 32 NSF Food Grade Mineral Oil
JX22HSS-F
13.5
400
ISO 32 NSF Food Grade Mineral Oil
JX37HSS-F
13.5
400
ISO 32 NSF Food Grade Mineral Oil
JX55CHSS-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
JX75CHSS-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
OIL FILL QUANTITY/TYPE
Note: The stator on this model is oil filled. This needs to be changed annually
when the seal oil is changed. With the power cable entry removed, fill the motor
chamber with oil to a level that insures the oil is covering the motor windings by
½”, and that will be above the upper bearing. Do not overfill, an air gap of 10-15%
must be maintained for heat expansion.
8
PUMP INSTALLATION
J-F & JX-F Series pumps have been evaluated for use with water or water based
solutions. Please contact the manufacturer for additional information.
Lifting:
Attach a rope or lifting chain (not included) to the handle (or lifting rings) on the top of
the pump.
Do not lift the pump by the power cable or discharge hose/piping.
Proper lifting equipment (rope/chain) must be used.
POSITIONING THE PUMP
BJM Pumps, J-F & JX-F Series pumps are designed to operate fully submerged. Data
sheets can be obtained online at HHUUwww.bjmpumps.comUUHH or by calling BJM Pumps, LLC at
860-399-5937.
Do not run pump dry.
Pump liquid should not exceed a maximum temperature of 200°F (93°C).
Never place the pump on loose or soft ground. The pump may sink, preventing
water from reaching the impeller. Place on a solid surface or suspend the pump
with a lifting rope/chain. The J-F & JX-F Series pumps are provided with a
suction strainer to prevent large solids from clogging the impeller. Any spherical
solids which pass through the strainer should pass through the pump.
For maximum pumping capacity, use the proper size non-collapsible hose or rigid
piping. A check valve may be installed after the discharge to prevent back flow
when the pump is shut off.
9
PUMP ROTATION
Two ways to check the correct pump rotation:
1. By looking at the impeller; the rotation of the impeller should be counter
clockwise as shown in the picture below.
2. By looking from the top of the pump. Since the impeller cannot be seen, the best
way to check the rotation is to check the kick back motion of the pump when the
pump just starts. The kick back motion of the pump should be counter clockwise
as shown in the picture below.
10
PUMP OPERATION
This pump is designed to handle dirty water that contains some
solids. It is not designed to pump volatile or flammable liquids. Do not attempt to pump
any liquids which may damage the pump or endanger personnel as a result of pump
failure.
Do not operate this pump where explosive vapors or
flammable material exist. Death or Serious injury will result.
NOTE: Maximum recommended starts should not exceed 10 times per hour.
All J-F & JX-F models are provided with a 33” (10m) power cord. NEVERUU splice the
power cable due to safety and warranty considerations. Always keep the lead end dry.
Note: 208V, 230V, 460V & 575V three phase units do not have a plug and have to be
provided separately.
Do not alter the length or repair any power cable with a splice. The
pump motor and cable must be completely waterproof. Damage to the pump or
personal injury may result from alterations.
For manual operation: 208, 230, 460 & 575 volt: Connect directly to the power source or
control box. Check the direction of the rotation. Tilt the pump and start it. It should twist
in the opposite direction of the arrow (on pump).
NOTE: Maximum recommended starts should not exceed 10 times per hour.
Three phase pumps need a separate control box with float(s) for automatic
operation.
STOPPING
To stop the pump (manual and automatic mode), unplug it from the power source, turn
off the breaker, or turn the power source off (generator).
12
Typical 3 Phase Manual Control 1
INTENDED METHODS OF CONNECTION
Use with approved motor control that matches motor input in full
load amperes. “UTILLISER UN DÉMARREAR APPROUVÉ CONVENANT AU
COURANT Á PLEINE CHARGE DU MOTEUR.”BJM Pumps submersible pumps have been evaluated for use with water or water
based solutions. Please contact the manufacturer for additional information.
FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP
FROM ITS POWER SOURCE BEFORE HANDLING.
“Risk of electrical shock” Do not remove power supply cord and
strain relief or connect conduit directly to the pump.
Installation and checking of electrical circuits and hardware should
be performed by a qualified licensed electrician.
THREE PHASE WIRING INSTRUCTIONS
FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP
FROM ITS POWER SOURCE BEFORE HANDLING.
“Risk of electrical shock” Do not remove power supply cord and
strain relief.
Installation and checking of electrical circuits and hardware should
be performed by a qualified licensed electrician.
13
Typical 3 Phase Auto Control 1
To automatically operate a non-automatic three phase pump, a control panel is
required. UUFollow the instructions provided with the panel to wire the system.UU For
automatic three phase pumps see automatic three phase wiring diagram.
Before installing a pump, make sure both of the ground leads and the power leads have
been connected properly. Once the power connections have been confirmed, then
check the pump rotation. Momentarily energize the pump, observing the directions of
kick back due to starting torque. Momentarily energize the pump, observing the
directions of kick back due to starting torque. Rotation is correct if kick back is in the
opposite direction of rotation arrow on the pump casing. If rotation is not correct,
switching of any two power leads other than ground will provide the proper rotation.
Three phase pumps do NOT have integral motor overload protection. Pumps must be
installed in accordance with the National Electrical Code and all applicable local codes
and ordinances. Pumps are not to be installed in locations classified as hazardous in
accordance with National Electrical Code, ANSI/NFPA 70.
Connect pump to a junction box, outlet box, control box, enclosure with a wiring
compartment that meets NEC and local codes. The provision for supply connection
shall reduce the risk of water entry during temporary, limited submersion and shall
comply with the applicable requirements of the Standard for Enclosures for Electrical
Equipment, UL 50, or the standard for Metallic Outlet Boxes, UL 514A, and the standard
for Motor-Operated Water Pumps. UL 778.
14
TROUBLE SHOOTING
Disconnect the power source to the pump BEFORE attempting
any type of trouble shooting, service or repair.
PUMP WILL NOT RUN
1. Check power supply (fuses, breaker).
Reset power.
2. Blocked impeller. Remove strainer,
check and clean.
3. Defective cable or incorrect wiring.
4. Strainer clogged. Check and clean as
necessary.
UU
PUMP RUNS BUT DOES NOT DELIVER RATED CAPACITY
1. Discharge line clogged, restricted or
hose kinked. Check discharge
hose/pipe.
2. Worn impeller and/or suction cover.
Inspect and replace as necessary.
3. Pump overloaded due to liquid pumped
being too thick.
5. Float switch tangled/obstructed.
Clean and free float switch from
obstruction.
6. Float switch defective. Replace float
switch.
4. Pumping air. Check liquid level and
position of pump.
5. Excessive voltage drops due to long
cables.
6. Three phase only; pump running
backwards, check rotation.
SERVICING YOUR SUBMERSIBLE PUMP
Pump should be disconnected from the electric power supply before proceeding to do
any service or maintenance.
The design of the “F” Series high temperature pump models is unique and requires
specific knowledge to perform the proper assembly. BJM Pumps recommends that all
electrical service work be performed at the factory, or by a factory trained and certified
repair technician, to insure that the materials and assembly methods meet BJM
standards.
MAINTAINING YOUR PUMP
Pump should be disconnected from the electric power supply before proceeding to
do any service or maintenance.
Pump should be inspected at regular intervals.
More frequent inspections are required if the pump is used in a harsh environment.
Preventative maintenance should be performed to reduce the chance of premature
failure.
Worn impellers and lip seals should be replaced.
Cut or cracked power cords must be replaced. (Never operate a pump with a cut,
cracked or damaged power cord.)
15
Seal oil should be checked once per year.
Maintenance should always be done when taking a pump out of service before
storage.
1) Clean pump of dirt and other build up.
2) Check condition of oil around the shaft seals.
3) Check hydraulic parts: check for wear.
4) Inspect power cable. Make sure that it is free of nicks or cuts.
CHANGING SEAL OIL
Changing the seal oil in the J-F & JX-F Series pumps is very easy.
1) Make sure that the pump is
deengergized and locked out for
service.
2) Lay the pump down on its side.
3) Remove the screws that hold the
bottom plate in place.
4) Remove bottom plate.
5) Remove screws holding the suction
cover.
6) Remove the suction cover.
7) Remove the impeller.
8) Remove the inspection screw for the oil
sample of the oil. If it is milky white, or
contains water, then the oil and
possible, the mechanical seal, should
be changed. If an oil change is needed:
9) Remove the screws that hold the oil
chamber cover in place & remove the
oil.
10) Replace the mechanical seal if
necessary.
11) Replace the oil.
12) Assemble the pump.
chamber (pos#50-08). Pour out a small
STATOR REPLACEMENT OR ELECTRICAL REPAIR
The BJM Pumps “F” Series designed pumps utilize unique construction methods and
materials. The inner connection of all wiring requires use of a BJM wire connection kit.
Included in this kit are specific instructions on how a qualified factory trained and
certified repair technician can perform this work properly. No other materials or methods
should be used on this product.
16
EXPLODED VIEW OF J08-F, J15-F, J15H-F
17
EXPLODED VIEW OF JX08SS-F, JX15SS-F, JX15HSS-F
18
EXPLODED VIEW OF J22-F, J22H-F, J37-F, J37H-F
19
EXPLODED VIEW OF JX22SS-F, JX22HSS-F, JX37SS-F, JX37HSS-F
20
EXPLODED VIEW OF J55C-F, JX55CSS-F, J55CH-F, JX55CHSS-F, J75C-F,
JX75CSS-F, J75CH-F, JX75CHSS-F
21
EXPLODED VIEW OF JX08SS-F, JX15SS-F, JX15HSS-F (PRECISION CAST
MODELS)
22
EXPLODED VIEW OF JX22SS-F, JX37SS-F (PRECISION CAST MODELS)
Seal Minder:
Also known as a seal failure circuit (or moisture detection circuit) is designed to inform
the pump operator that there is moisture within the oil chamber. This early warning can
allow the operator to schedule repair & inspection on the pump. The Seal Minder
sensor probe is inside the oil chamber. (The oil chamber houses the mechanical seals
that are cooled & lubricated by oil). The Seal Minder, when properly connected to a
control panel, can help indicate seal failure. The Seal Minder cord requires a seal fail
circuit in control panel for warning signal.
Along, with the Seal Minder, the Fahrenheit™ Series high temperature pumps also
feature thermal temperature sensor switches that are imbedded into the motor stator
windings. Three switches are imbedded into the stator windings and wired in series. The
leads are connected to the pump control panel through the sensor cable. If the windings
would see a temperature above 300 degrees F, then the switch(s) would open and cut
power to the pump. Once the temperature dropped below 300 degrees F, the switch(s)
would reset, and the pump would be returned to a state of operation. This feature is
designed to prevent damage to the stator winding and allow for longer pump life.
The sensor cable consists of four leads, two are connected to the Seal Minder, and two
are connected to the thermal sensor switches located in the stator windings. These four
leads run to the pump control panel and connect to the proper connections points for
seal alarm and thermal cut off. The black and white wires are for the Seal Minder
connections and the thermal sensors will be connected to the yellow and red wires. The
three phase automatic wiring diagram shown earlier in the manual will give a guide to
the connections in the control panel. The manual for the control panel should be
consulted for the exact connections.
The sensor cable with Seal Minder and thermal sensor switch connections is standard
on all Fahrenheit™ Series high temperature pumps. The cable is designed for a high
temperature environment. The proper replacement part can be found parts list found in
this manual. BJM Pumps, can supply a control with the Seal Minder and Thermal
sensor switch option. Separate stand alone Seal Minder alarm panels are also
available. Consult your BJM Pumps representative for part numbers and ordering
details. BJM Pumps requires the Seal Minder and thermal sensor switches be used.
Failure to connect or misuse of these devices will void warranty.
32
33
BJM Pumps, LLC
123 Spencer Plain Road
Old Saybrook, CT 06475, U.S.A.
WARRANTY AND LIMITATION OF LIABILITY
Unless otherwise expressly authorized in writing, specifying a longer or shorter period, BJM
Pumps, LLC warrants for a period of eighteen (18) months from the date of shipment from the
Point of Shipment, or one (1) year from the date of installation, whichever occurs first, that all
products or parts thereof furnished by BJM Pumps, LLC under the brand name BJM Pumps,
hereinafter referred to as the “Product” are free from defects in materials and workmanship and
conform to the applicable specification.
BJM Pumps, LLC’s liability for any breach of this warranty shall be limited solely to replacement
or repair, at the sole option of BJM Pumps, LLC, of any part or parts of the Product found to be
defective during the warranty period, provided the Product is properly installed and is being
used as originally intended. Any breach of this warranty must be reported to BJM Pumps, LLC
or BJM Pumps, LLC’s authorized service representative within the aforementioned warranty
period, and defective Product or parts thereof must be shipped to BJM Pumps, LLC or BJM
Pumps, LLC’s authorized representative, transportation charges prepaid. Any cost associated
with removal or installation of a defective Product or part is excluded.
IT IS EXPRESSLY AGREED THAT THIS SHALL BE THE SOLE AND EXCLUSIVE REMEDY
OF BJM PUMPS, LLC’S DISTRIBUTORS AND CUSTOMERS. UNDER NO CIRCUMSTANCES
SHALL BJM PUMPS, LLC BE LIABLE FOR ANY COSTS, LOSS, EXPENSE, DAMAGES,
SPECIAL DAMAGES, INCIDENTAL DAMAGES OR CONSEQUENTIAL DAMAGES ARISING
DIRECTLY OR INDIRECTLY FROM THE DESIGN, MANUFACTURE, SALE, USE OR REPAIR
OF THE PRODUCT, WHETHER BASED ON WARRANTY, CONTRACT, NEGLIGENCE, OR
STRICT LIABILITY. IN NO EVENT WILL LIABILITY EXCEED THE PURCHASE PRICE OF
THE PRODUCT.
THE WARRANTY AND LIMITS OF LIABILITY CONTAINED HEREIN ARE IN LIEU OF ALL
OTHER WARRANTIES AND LIABILITIES, EXPRESSED OR IMPLIED. ALL IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
HEREBY DISCLAIMED BY BJM PUMPS, LLC AND EXCLUDED FROM THIS WARRANTY.
BJM Pumps, LLC neither assumes, nor authorizes any person to assume for it, any other
warranty obligation in connection with the sale of the Product. This warranty shall not apply to
any Product or parts of Product which have (a) been repaired or altered outside of BJM Pumps,
LLC’s facilities unless such repair was authorized in advance by BJM Pumps, LLC or by its
authorized representative; or (b) have been subject to misuse, negligence or accident; or (c)
have been used in a manner contrary to BJM Pumps, LLC’s instruction.
In any case of products not manufactured and sold under the BJM Pumps, LLC brand name,
there is no warranty from BJM Pumps, LLC; however BJM Pumps, LLC will extend any warranty
received from BJM Pumps, LLC’s supplier of such products.
START-UP REPORT FORM
Pump Owner’s Name
Location of Installation
Person in Charge
Phone( )
Purchased From
Model
Serial No
Voltage
Phase
Hertz
HP
Does impeller turn freely
by hand?
Yes No
Condition of Equipment
New Good Fair Poor
Condition of Cable Jacket
New Good Fair Poor
Rotation: Direction of Impeller Rotation (Use C/W for clockwise, CC/W for counterclockwise):
Method used to check rotation (viewed from bottom)
Resistance of cable and Pump Motor (measured at pump control)
Red-Black
ohms
Red-White
ohms
White-Blackohms
Resistance of ground circuit between control panel and outside of pumps
Ohms
MEG OHM CHECK OF INSULATION
Red to ground White to ground Black to ground
Condition of location at start-up
Dry Wet Muddy
Was equipment stored
If YES, length of storage:
Yes No.
Liquid being pump
Debris in bottom of station?
Yes No
Was debris removed in your
Yes No
START-UP REPORT FORM
This form is designed to record the initial installation, and to serve as a guide for troubleshooting at a
later date (if needed).
BJM Pumps, LLC
123 Spencer Plain Road
Old Saybrook, CT. 06475
START-UP REPORT FORM
presence?
Are guide rails exactly vertical?
Yes No
Is base elbow installed level?
Yes No
Liquid level controls: Model
Is control installed away from
turbulence?
Yes No
Operation Check
Tip lowest float (stop float), all pumps should remain off.
Tip second float (and stop float), one pump comes on.
Tip third float (and stop float), both pumps on (alarm on simplex).
Tip fourth float (and stop float), high level alarm on (omit on simplex).
If not on levels controls, describe type of controls
Does liquid level ever drop below
volute top?
Yes No
Control Panel MFG & model no.
Number of pumps operated by control panel
NOTE: At no time should hole be made in top of control panel, unless proper sealing
devices are utilized.
Short Circuit protection:
Type:
Number and size of short circuit device(s)
Amp rating:
Overload type:
Size:
Amp rating:
Do protective devices comply with
pump motor amp rating?
Yes No
Are all pump connections tight?
Yes No
Is the interior of the panel dry?
Yes No
If No, correct moisture problem.
SINGLE PHASE
Voltage supply at panel line
connection, pump off
L1
L2
Voltage supply at panel line
connection, pump on
L1
L2
Amperage load connection, pump on
L1
L2
THREE PHASE
Voltage supply at panel line connection, pump off
L1-L2
L2-L3
L3-L1
START-UP REPORT FORM
Voltage supply at panel line connection, pump on
L1-L2
L2-L3
L3-L1
Amperage load connection, pump on
L1
L2
L3
FINAL CHECK
Is pump secured properly?
Yes No
Was pump checked for leaks?
Yes No
Do check valves operate properly?
Yes No
Flow: Does station appear to operate at
proper rate?
Yes No
Noise level:
Acceptable
Unacceptable
Comments:
Describe and equipment difficulties during start-up
Installed by:
Company:
Person:
Date:
Maintained by:
Company:
Person:
Date and time of start-up
Present at start-up:
( ) Engineer’s name( )Contractor’s name( ) Operator’s name
( ) others
NOTES:
BJM Pumps, LLC
123 Spencer Plain Road • PO Box 1138 • Old Saybrook, CT 06475, USA
• Phone: (860) 399-5937 • Fax: (860) 399-7784
Email: sales@bjmpumps.com • Web Site: www.bjmpumps.com
BJM Pumps & Seal Minder is a registered trademark of BJM Pumps, LLC