BJM Pumps JX-F User Manual

UUCAST IRONUU
UUTHREE PHASEUU
J08-F J15-F J22-F
J37-F J55C-F J75C-F
J15H-F J22H-F J37H-F J55CH-F J75CH-F
U316 STAINLESS STEELU
UUTHREE PHASEUU
JX08SS-F JX15SS-F JX22SS-F
JX37SS-F JX55CSS-F JX75CSS-F
JX15HSS-F JX22HSS-F JX37HSS-F JX55CHSS-F JX75CHSS-F
INSTALLATION, OPERATION & MAINTENANCE MANUAL
FARHENHEIT
J-F & JX-F SERIES
SIDE DISCHARGE
Three Phase
208V, 230V, 460V & 575V
Read this manual carefully before installing, operating or servicing these pump models.
UUObserve all safety information.UU Failure to comply with instructions may result in personal
injury and/or property damage. Please retain these instructions.
Version 2/11/14
TABLE OF CONTENTS
INTRODUCTION ........................................................................................................................................................................ 4
SAFETY ...................................................................................................................................................................................... 5
INSPECTION .............................................................................................................................................................................. 6
PRE-INSTALLATION INSPECTION ...................................................................................................................................... 6
LUBRICATION: ...................................................................................................................................................................... 6
OIL FILL QUANTITY/TYPE .................................................................................................................................................... 7
PUMP INSTALLATION .......................................................................................................................................................... 8
POSITIONING THE PUMP .................................................................................................................................................... 8
PUMP ROTATION ................................................................................................................................................................. 9
TYPICAL MANUAL WATER/WASTEWATER EFFLUENT INSTALLATION ............................................................................. 10
TYPICAL AUTOMATIC WATER/WASTEWATER EFFLUENT INSTALLATION ...................................................................... 11
STOPPING .......................................................................................................................................................................... 11
INTENDED METHODS OF CONNECTION .............................................................................................................................. 12
THREE PHASE WIRING INSTRUCTIONS .......................................................................................................................... 12
TROUBLE SHOOTING ............................................................................................................................................................. 14
PUMP WILL NOT RUN ........................................................................................................................................................ 14
PUMP RUNS BUT DOES NOT DELIVER RATED CAPACITY ........................................................................................... 14
SERVICING YOUR SUBMERSIBLE PUMP ........................................................................................................................ 14
MAINTAINING YOUR PUMP ............................................................................................................................................... 14
CHANGING SEAL OIL ......................................................................................................................................................... 15
EXPLODED VIEW OF J08-F, JX08SS-F, J15-F, JX15SS-F, J15H-F, JX15HSS-F .................................................................. 17
EXPLODED VIEW OF J22-F, JX22SS-F, J22H-F, JX22HSS-F, J37-F, JX37SS-F, J37H-F, JX37HSS-F ............................... 18
EXPLODED VIEW OF J55C-F, JX55CSS-F, J55CH-F, JX55CHSS-F, J75C-F, JX75CSS-F, J75CH-F, JX75CHSS-F ........... 20
EXPLODED VIEW OF JX08SS-F, JX15SS-F, JX15HSS-F (PRECISION CAST MODELS) .................................................... 21
EXPLODED VIEW OF JX22SS-F, JX37SS-F (PRECISION CAST MODELS) ......................................................................... 22
J-F SERIES PARTS LIST ......................................................................................................................................................... 23
JX-F SERIES PARTS LIST ....................................................................................................................................................... 25
THREE PHASE WIRING DIAGRAM ......................................................................................................................................... 27
208V ..................................................................................................................................................................................... 27
MODELS: J08-F, JX08SS-F, J15-F, JX15SS-F, J15H-F, JX15HSS-F, J22-F, JX22SS-F, J22H-F, JX22HSS-F, J37-F,
JX37SS-F, J37H-F, J37HSS-F, J55C-F, J55CSS-F, J55CH-F, J55CHSS-F ................................................................... 27
230V ..................................................................................................................................................................................... 28
MODELS: J08-F, JX08SS-F, J15-F, JX15SS-F, J15H-F, JX15HSS-F, J22-F, JX22SS-F, J22H-F, JX22HSS-F, J37-F. JX37SS-F, J37H-F, J37HSS-F, J55C-F, J55CSS-F, J55CH-F, J55CHSS-F, J75C-F, JX75CSS-F, J75CH-F, J75CHSS-F
.......................................................................................................................................................................................... 28
460V ..................................................................................................................................................................................... 29
MODELS: J08-F, JX08SS-F, J15-F, JX15SS-F, J15H-F, JX15HSS-F, J22-F, JX22SS-F, J22H-F, JX22HSS-F, J37-F. JX37SS-F, J37H-F, J37HSS-F, J55C-F, J55CSS-F, J55CH-F, J55CHSS-F, J75C-F, JX75CSS-F, J75CH-F, J75CHSS-F
.......................................................................................................................................................................................... 29
575V ..................................................................................................................................................................................... 30
MODELS: J08-F, JX08SS-F, J15-F, JX15SS-F, J15H-F, JX15HSS-F, J22-F, JX22SS-F, J22H-F, JX22HSS-F, J37-F. JX37SS-F, J37H-F, J37HSS-F, J55C-F, J55CSS-F, J55CH-F, J55CHSS-F, J75C-F, JX75CSS-F, J75CH-F, J75CHSS-F
.......................................................................................................................................................................................... 30
SEAL MINDER® - THERMAL MOTOR SENSOR SWITCH ...................................................................................................... 31
WARRANTY AND LIMITATION OF LIABILITY ........................................................................................................................ 33
START-UP REPORT FORM .................................................................................................................................................... 34
NOTES: .................................................................................................................................................................................... 37
4
INTRODUCTION
This Installation, Operation and Maintenance manual provides important information on safety and the proper inspection, disassembly, reassembly and testing of the BJM Pumps® J-F & JX­F Series submersible pump. This manual also contains information to optimize performance
and longevity of your BJM Pumps submersible pump. The F Series FARHRENHEIT™ pumps are engineered to pump water based liquids up to 200° Fahrenheit (93°C).
The submersible J-F Series pumps are designed to pump water and wastewater. The JX-F Series pumps are designed to pump corrosive liquids in concentrations chemically compatible with 316SS and FKM. The J-F & JX-F Series pumps are not explosion proof. They are not designed to pump volatile or flammable liquids.
Note: Consult chemical resistance chart for compatibility between pump materials and liquid before operating pump. Consult BJM engineering if there is a question on chemical compatibility.
If you have any questions regarding the inspection, disassembly, assembly or testing please contact your BJM Pumps distributor, or BJM Pumps, LLC.
BJM Pumps, LLC 123 Spencer Plain Rd. Old Saybrook, CT 06475, USA
Fax: 860-399-7784 Phone: 877-256-7867 Phone: 860-399-5937
Information, including pump data sheets and performance curves, is also available on our web site: HHUUwww.bjmpumps.comUU
For assistance with your electric power source, please contact a certified electrician. Please pay attention to the following alert notifications. They are used to notify
operators and maintenance personnel to pay special attention to procedures, to avoid causing damage to the equipment, and to avoid situations that could be dangerous to personnel.
NOTE: Instructions to aid in installation, operation, and maintenance or which clarify a procedure.
Immediate hazards that WILL result in severe personal injury or death. These instructions describe the procedure required and the injury which will result from failure to follow the procedure.
Hazards or unsafe practices that COULD result in severe personal injury or death. These instructions describe the procedure required, and the injury which could result from failure to follow the procedure.
Hazards or unsafe practices which COULD result in personal injury or product or property damage. These instructions describe the procedure required and the possible damage which could result from failure to follow the procedure.
5
SAFETY
Pump installations are seldom identical. Each installation and application can vary due to many different factors. It is the owner/service mechanics responsibility to repair, service, and test to ensure that the pump integrity is not compromised according to this manual.
Risk of electric shock – this pump has not been investigated for use
in swimming pool areas.
Do not pump flammable or volatile liquids. UUDeath or serious
injury will result.
Before attempting to open or service the pump:
1) Familiarize yourself with this manual.
2) Unplug or disconnect the pump power cable to ensure that the pump will remain
inoperative.
3) Allow the pump to cool if overheated.
Do not operate the pump with a worn or damaged electric power
cable. Death or serious injury could occur.
Never attempt to alter the length or repair any power cable with a splice. The pump motor and pump motor and cable must be completely waterproof. Damage to the pump or personal injury may result from alterations.
After the pump has been installed, make sure that the pump and all piping are secure before operation.
Do not lift the pump by the power cable piping or discharge hose. Attach proper lifting equipment to the lifting handle (or lifting rings) fitted to the pump. Do not suspend the pump by the power cable.
Obtain the services of a qualified electrician to troubleshoot, test and/or service the electrical components of this pump.
Pumps and related equipment must be installed and operated
according to all national, local and industry standards.
6
INSPECTION
Review all safety information before servicing pump.
The following are recommended installation practices/procedures for the pump. If there are questions in regards to your specific application, contact your local BJM Pumps distributor or BJM Pumps, LLC.
PRE-INSTALLATION INSPECTION
1) Check the pump for damage that may have occurred during shipment.
2) Inspect the pump for any cracks, dents, damaged threads, etc.
3) Check power cord and sensor cable for any cuts or damage.
4) Check for, and tighten any hardware that appears loose.
5) Carefully read all tags, decals and markings on the pump.
If anything appears to be abnormal, contact your BJM Pumps distributor or BJM Pumps, LLC. If damaged, the pump may need to be repaired before use. Do not install or use the pump until appropriate action has been taken.
LUBRICATION:
No additional lubrication is necessary. The shaft seal and bearings are fully lubricated from the factory. Seal oil should be checked once per year. See table on page 7.
7
Qty. oil in seal chamber
Models
U.S. fl. oz.
C.C.
Type of oil
J08-F
9
265
ISO 32 NSF Food Grade Mineral Oil
J15-F
9
265
ISO 32 NSF Food Grade Mineral Oil
J22-F
10.8
320
ISO 32 NSF Food Grade Mineral Oil
J37-F
10.8
320
ISO 32 NSF Food Grade Mineral Oil
J55C-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
J75C-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
Qty. oil in seal chamber
Models
U.S. fl. oz.
C.C.
U.S. fl. oz.
J08H-F
9
265
ISO 32 NSF Food Grade Mineral Oil
J15H-F
9
265
ISO 32 NSF Food Grade Mineral Oil
J22H-F
10.8
320
ISO 32 NSF Food Grade Mineral Oil
J37H-F
10.8
320
ISO 32 NSF Food Grade Mineral Oil
J55CH-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
J75CH-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
Qty. oil in seal chamber
Models
U.S. fl. oz.
C.C.
Type of oil
JX08SS-F
10.1
300
ISO 32 NSF Food Grade Mineral Oil
JX15SS-F
10.1
300
ISO 32 NSF Food Grade Mineral Oil
JX22SS-F
13.5
400
ISO 32 NSF Food Grade Mineral Oil
JX37SS-F
13.5
400
ISO 32 NSF Food Grade Mineral Oil
JX55CSS-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
JX75CSS-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
Qty. oil in seal chamber
Models
U.S. fl. oz.
C.C.
Type of oil
J08HSS-F
10.1
300
ISO 32 NSF Food Grade Mineral Oil
JX15HSS-F
10.1
300
ISO 32 NSF Food Grade Mineral Oil
JX22HSS-F
13.5
400
ISO 32 NSF Food Grade Mineral Oil
JX37HSS-F
13.5
400
ISO 32 NSF Food Grade Mineral Oil
JX55CHSS-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
JX75CHSS-F
45.6
1350
ISO 32 NSF Food Grade Mineral Oil
OIL FILL QUANTITY/TYPE
Note: The stator on this model is oil filled. This needs to be changed annually
when the seal oil is changed. With the power cable entry removed, fill the motor
chamber with oil to a level that insures the oil is covering the motor windings by
½”, and that will be above the upper bearing. Do not overfill, an air gap of 10-15%
must be maintained for heat expansion.
8
PUMP INSTALLATION
J-F & JX-F Series pumps have been evaluated for use with water or water based solutions. Please contact the manufacturer for additional information.
Lifting:
Attach a rope or lifting chain (not included) to the handle (or lifting rings) on the top of the pump.
Do not lift the pump by the power cable or discharge hose/piping.
Proper lifting equipment (rope/chain) must be used.
POSITIONING THE PUMP
BJM Pumps, J-F & JX-F Series pumps are designed to operate fully submerged. Data
sheets can be obtained online at HHUUwww.bjmpumps.comUUHH or by calling BJM Pumps, LLC at 860-399-5937.
Do not run pump dry. Pump liquid should not exceed a maximum temperature of 200°F (93°C). Never place the pump on loose or soft ground. The pump may sink, preventing
water from reaching the impeller. Place on a solid surface or suspend the pump with a lifting rope/chain. The J-F & JX-F Series pumps are provided with a suction strainer to prevent large solids from clogging the impeller. Any spherical solids which pass through the strainer should pass through the pump.
For maximum pumping capacity, use the proper size non-collapsible hose or rigid
piping. A check valve may be installed after the discharge to prevent back flow when the pump is shut off.
9
PUMP ROTATION
Two ways to check the correct pump rotation:
1. By looking at the impeller; the rotation of the impeller should be counter clockwise as shown in the picture below.
2. By looking from the top of the pump. Since the impeller cannot be seen, the best way to check the rotation is to check the kick back motion of the pump when the pump just starts. The kick back motion of the pump should be counter clockwise as shown in the picture below.
10
PUMP OPERATION
This pump is designed to handle dirty water that contains some solids. It is not designed to pump volatile or flammable liquids. Do not attempt to pump any liquids which may damage the pump or endanger personnel as a result of pump failure.
Do not operate this pump where explosive vapors or
flammable material exist. Death or Serious injury will result.
TYPICAL MANUAL WATER/WASTEWATER EFFLUENT INSTALLATION
NOTE: Maximum recommended starts should not exceed 10 times per hour.
All J-F & JX-F models are provided with a 33” (10m) power cord. NEVERUU splice the power cable due to safety and warranty considerations. Always keep the lead end dry.
Note: 208V, 230V, 460V & 575V three phase units do not have a plug and have to be provided separately.
Do not alter the length or repair any power cable with a splice. The pump motor and cable must be completely waterproof. Damage to the pump or personal injury may result from alterations.
For manual operation: 208, 230, 460 & 575 volt: Connect directly to the power source or control box. Check the direction of the rotation. Tilt the pump and start it. It should twist in the opposite direction of the arrow (on pump).
11
TYPICAL AUTOMATIC WATER/WASTEWATER EFFLUENT INSTALLATION
NOTE: Maximum recommended starts should not exceed 10 times per hour.
Three phase pumps need a separate control box with float(s) for automatic operation.
STOPPING
To stop the pump (manual and automatic mode), unplug it from the power source, turn off the breaker, or turn the power source off (generator).
12
Typical 3 Phase Manual Control 1
INTENDED METHODS OF CONNECTION
Use with approved motor control that matches motor input in full load amperes. UTILLISER UN DÉMARREAR APPROUVÉ CONVENANT AU COURANT Á PLEINE CHARGE DU MOTEUR.” BJM Pumps submersible pumps have been evaluated for use with water or water based solutions. Please contact the manufacturer for additional information.
FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP
FROM ITS POWER SOURCE BEFORE HANDLING.
“Risk of electrical shock” Do not remove power supply cord and
strain relief or connect conduit directly to the pump.
Installation and checking of electrical circuits and hardware should
be performed by a qualified licensed electrician.
THREE PHASE WIRING INSTRUCTIONS
FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP
FROM ITS POWER SOURCE BEFORE HANDLING.
“Risk of electrical shock” Do not remove power supply cord and
strain relief.
Installation and checking of electrical circuits and hardware should
be performed by a qualified licensed electrician.
Loading...
+ 26 hidden pages