All BJM Pumps are carefully inspected and water tested to insure both safety and operating performance. Failure
to follow the instructions and warnings in this manual may result in pump damage and/or bodily injury.
This pump is designed to operate, completely or partially, submerged. Do not let pump run dry for more than ten
minutes. Do not use this pump in chemicals, solvents, flammables, or heavy liquids such as oil or grease. Always
lift the pump by its handle.
RULES FOR SAFE
INSTALLA TION & OPERATION
CAUTION:
1.TO REDUCE THE RISK OF ELECTRIC SHOCK, ALWAYS DISCONNECT THE PUMP FROM THE
POWER SOURCE BEFORE SERVICING ANY PUMP.
2. Read and follow all instructions carefully.
3. Do not pump flammable liquids such as gasoline or other fuels.
4. Always connect pump to a properly grounded receptacle.
5. Do not handle the pump with wet hands or while standing in water.
PUMP PERFORMANCE
DISCHARGE HEAD
GALLONS PER HOUR
NOTE: The above ratings are based on 1" pipe discharge. The use of the 3/4" garden hose adaptor will reduce
the "gallons per hour" flow by approximately 15%.
3'6'9'12'15'18'21'
1300 1150 925750450250 61
SHUT OFF FEET
23'
ELECTRICAL CONNECTIONS
Your 12 Volt "BABY" pump is supplied with 16.5 feet of power cord, and standard battery clips.
IMPORTANT: RED LEAD T O POSITIVE (+)
BLACK LEAD TO NEGATIVE (-)
THE WARRANTY ON THE MOTOR BRUSHES FOR "THE BABY" PUMP, IS 500 HOURS OF OPERATING
TIME.
WARNING
Always disconnect power before undertaking any work on pump, cable, control box, or accessories. Do not
attempt to attach any AC type adaptors to the power cord, or use an AC power source to operate the pump.
OPERATION
3 of 4
Place pump on flat, solid surface in at least 3/4" of water. Connect garden hose to hose adaptor
or install 1" threaded pipe directly into the discharge of the pump. Connect power supply cord to
a 12 Volt D.C. grounded receptacle.
When using pump on a dirt or sand surface, always have outer screen in place to prevent mud or
debris from entering the pump.
MAINT AINING YOUR PUMP
The motor housing of the "BABY" pump is completely sealed and requires no service. Disassembly
of the housing or the power cord will void the warranty.
The motor of this pump has a built-in thermal overload protector that will automatically shut the
pump off if the operating temperature of the motor becomes too high.
If the pump becomes clogged; disconnect the power source, remove the outer screen, and flush
thoroughly with water. If the impeller will not turn, remove the six screws that secure the pump
volute (Fig. 1) and check for debris that may be lodged between the impeller and volute.
CAUTION: Not suitable for use in corrosive or flammable liquids.
Unless otherwise expressly authorized in writing, specifying a longer or shorter period, BJM Corp warrants for a
period of eighteen (18) months from the date of shipment from the Point of Shipment, or one (1) year from the
date of installation, whichever occurs first, that all products or parts thereof furnished by BJM Corp under the
brand name BJM, hereinafter referred to as the “Product” are free from defects in materials and workmanship
and conform to the applicable
specification.
BJM Corp’s liability for any breach of this Warranty shall be limited solely to replacement or repair, at the sole
option of BJM Corp, of any part or parts of the Product found to be defective during the Warranty period,
provided the Product is properly installed and is being used as originally intended. Any breach of this Warranty
must be reported to BJM Corp or BJM Corp’s authorized service representative within the aforementioned
Warranty period, and defective Product or parts thereof must be shipped to BJM Corp or BJM Corp’s authorized
representative, transportation charges prepaid. Any cost associated with removal or installation of a defective
Product or part is excluded.
IT IS EXPRESSLY AGREED THAT THIS SHALL BE THE SOLE AND EXCLUSIVE REMEDY OF BJM CORP’S
DISTRIBUTORS AND CUSTOMERS. UNDER NO CIRCUMSTANCES SHALL BJM CORP BE LIABLE FOR
ANY COSTS, LOSS, EXPENSE, DAMAGES, SPECIAL DAMAGES, INCIDENTAL DAMAGES OR
CONSEQUENTIAL DAMAGES ARISING DIRECTLY OR INDIRECTLY FROM THE DESIGN, MANUFACTURE,
SALE, USE OR REPAIR OF THE PRODUCT, WHETHER BASED ON WARRANTY, CONTRACT,
NEGLIGENCE, OR STRICT LIABILITY. IN NO EVENT WILL LIABILITY EXCEED THE PURCHASE PRICE
OF THE PRODUCT.
THE WARRANTY AND LIMITS OF LIABILITY CONTAINED HEREIN ARE IN LIEU OF ALL OTHER
WARRANTIES AND LIABILITIES, EXPRESSED OR IMPLIED. ALL IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED BY BJM
CORP AND EXCLUDED FROM THIS WARRANTY.
BJM Corp neither assumes, nor authorizes any person to assume for it, any other Warranty obligation in
connection with the sale of the Product. This Warranty shall not apply to any Product or parts of Product which
have (a) been repaired or altered outside of BJM Corp’s facilities unless such repair was authorized in advance
by BJM Corp or by its authorized representative; or (b) have been subject to misuse, negligence or accident; or
(c) have been used in a manner contrary to BJM Corp’s instruction.
In any case of products not manufactured and sold under the BJM Corp brand name, there is no Warranty from
BJM Corp; however BJM Corp will extend any Warranty received from BJM Corp’s supplier of such products.
8/5/2014
Visit our website: www.bjmpumps.com 0806
Supersedes
TECHNICAL DATA
MODEL BABY – 12V
BJM SUBMERSIBLE PUMP
GENERAL DATA
MAX. FLOW: 1500 GPH / 25 GPM (94.6 L/min)
MAX. HEAD: ft (m) 23’ (7 m)
MAX. SUBMERSION DEPTH: ft (m) 20’ (6 m) or limited to length of power cord
PUMP TYPE 12 Volt D.C. ELECTRIC SUBMERSIBLE
SOLID SIZE: in (mm) 1/16” (1.58 mm)
STRAINER OPENING 1/16” x 9/16” slot (1.58 mm x 14.28 mm)
DISCHARGE SIZE 1” (¾” GARDEN HOSE ADAPTER INCLUDED)
WEIGHT: lbs (kg) 8 lbs (3.7 kg)
CONSTRUCTION/MATERIAL DATA
MOTOR CASING ANODIZED ALUMINUM
MOTOR HOUSING PVC
PUMP VOLUTE PVC
IMPELLER- MULTI VANE PVC
STRAINER PVC
SHAFT SEAL – LIPSEAL BUNA-N
O-RING BUNA-N
ROTOR SHAFT AISI 420
EXTERNAL HARDWARE 304 SS
BALL BEARING: PERM. LUBE. UPPER 608
BALL BEARING: PERM. LUBE. LOWER 608
ELECTRICAL /MOTOR DATA
MOTOR: TYPE, RATING POWER SUBMERSIBLE, 200 WATTS
MOTOR INSULATION CLASS F
MOTOR SERVICE FACTOR 1.0
VOLTAGE 12 VOLT D.C.
CURRENT F.L.A. 16
POWER CORD: GAGE; LENGTH 14/2; 16.5’ (5 m) WITH TERMINAL CLIPS
MINIMUM SUBMERSION DEPTH FOR
CONTINUOUS DUTY: in (mm)
2.5” (64 mm)
PUMP PERFORMANCE
HEAD (FT)
U.S. GALLONS
PER HOUR
NOTE: The above ratings are based on 1” pipe discharge. The use of the ¾” garden hose adapter
will reduce the “gallons per hour” flow by approximately 15%.
Unless otherwise expressly authorized in writing, specifying a longer or shorter period, BJM
Pumps, LLC warrants for a period of eighteen (18) months from the date of shipment from the
Point of Shipment, or one (1) year from the date of installation, whichever occurs first, that all
products or parts thereof furnished by BJM Pumps, LLC under the brand name BJM Pumps,
hereinafter referred to as the “Product” are free from defects in materials and workmanship and
conform to the applicable specification.
BJM Pumps, LLC’s liability for any breach of this warranty shall be limited solely to replacement
or repair, at the sole option of BJM Pumps, LLC, of any part or parts of the Product found to be
defective during the warranty period, provided the Product is properly installed and is being
used as originally intended. Any breach of this warranty must be reported to BJM Pumps, LLC
or BJM Pumps, LLC’s authorized service representative within the aforementioned warranty
period, and defective Product or parts thereof must be shipped to BJM Pumps, LLC or BJM
Pumps, LLC’s authorized representative, transportation charges prepaid. Any cost associated
with removal or installation of a defective Product or part is excluded.
IT IS EXPRESSLY AGREED THAT THIS SHALL BE THE SOLE AND EXCLUSIVE REMEDY
OF BJM PUMPS, LLC’S DISTRIBUTORS AND CUSTOMERS. UNDER NO CI RCUMSTA NCES
SHALL BJM PUMPS, LLC BE LIABLE FOR ANY COSTS, LOSS, EXPENSE, DAMAGES,
SPECIAL DAMAGES, INCIDENTAL DAMAGES OR CONSEQUENTIAL DAMAGES ARISING
DIRECTLY OR INDIRECTLY FROM THE DESIGN, MANUFACTURE, SALE, USE OR REPAIR
OF THE PRODUCT, WHETHER BASED ON WARRANTY, CONTRACT, NEGLIGENCE, OR
STRICT LIABILITY. IN NO EVENT WILL LIABILITY EXCEED THE PURCHASE PRICE OF
THE PRODUCT.
THE WARRANTY AND LIMITS OF LIABILITY CONTAINED HEREIN ARE IN LIEU OF ALL
OTHER WARRANTIES AND LIABILITIES, EXPRESSED OR IMPLIED. ALL IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A P ARTICULAR PURPOSE ARE
HEREBY DISCLAIMED BY BJM PUMPS, LLC AND EXCLUDED FROM THIS WARRANTY.
BJM Pumps, LLC neither assumes, nor authorizes any person to assume for it, any other
warranty obligation in connection with the sale of the Product. This warranty shall not apply to
any Product or parts of Product which have (a) been repaired or altered outside of BJM Pumps,
LLC’s facilities unless such repair was authorized in advance by BJM Pumps, LLC or by its
authorized representative; or (b) have been subject to misuse, negligence or accident; or (c)
have been used in a manner contrary to BJM Pumps, LLC’s instruction.
In any case of products not manufactured and sold under the BJM Pumps, LLC brand name,
there is no warranty from BJM Pumps, LLC; however BJM Pumps, LLC will extend any warranty
received from BJM Pumps, LLC’s supplier of such products.