Dual Sensor & High Power Calibration Carts ................................................................................................9
Model 4421 Power Meter and 4020 Series................................................................................................10
Model 4027A ............................................................................................................................................11
Model 4028 ..............................................................................................................................................12
Power Measurement
Model 5012 Wideband Sensor and vDPM software....................................................................................13
Model 5011 and 5011-EF Terminating Sensor ..........................................................................................14
RF Monitoring System ..............................................................................................................22
RF Power Analyst ......................................................................................................................................22
Bus Interface Units and
RF Signal Samplers ..................................................................................................................................23
Field Strength Meter ..................................................................................................................................24
Meter Movements and 7/8” Line Sections ................................................................................................24
1 5/8” - 6 1/8” Rigid Line Systems
Wattcher
®
RF Monitoring System ..............................................................................................................25
Rigid Line Sections ....................................................................................................................................26
Meters for Rigid Line Use ..........................................................................................................................26
Digital Air Loads ........................................................................................................................................35
Elements ............................................................................................................................................40-43
Accessories and Connectors ..........................................................................................................44-46
Technical Information ......................................................................................................................47-50
Product Index ....................................................................................................................................51-52
Bird®Electronic Corporation maintains an aggressive program of testing products for conformity applicable electromagnetic and safety
standards, including European Union Directives. We are proud to announce that, where applicable, Bird products carry the “CE” Mark.
A CE marked product complies with the relevant EU Directives and is approved for sale in the European Union. The specific standards
that were used to evaluate the product compliance are listed on the Declaration of Conformity (DOC).
Bird®Electronic Corporation provides solutions to the following markets.
For your convenience, each product represented in the catalog includes the market
icon(s) for your reference. For more application information, please visit our
website www.bird-technologies.com.
Market Solutions
Public Safety
Integrated Antenna Analysis
Reliable, Rugged, Power Measurement
Rugged, Versatile Load and Attenuator Kits Available
Government/Military
Integrated Antenna Analysis
Field Testing of Tactical Radio Systems
Power Measurement, Resistive Components and Subassemblies
Rugged, Versatile Load and Attenuator Kits Available
Semiconductor
Precision Power Measurement Solutions and Calorimetric Systems
Highly Stable, Reliable, Terminations, Loads, and Attenuators
MODEL SH-36S Spectrum Analyzer with Power Meter Option
SIGNALHAWK
TM
Bird Technologies SignalHawkTMAnalyzes radio frequency spectrum.
Measures intended and interfering signals. Allows setup of parameters
such as frequency, amplitude, and markers. Graphically displays signal
amplitude vs. frequency and saves traces.
KEY FEATURES
• Fast, Accurate, and Sensitive: -135 dBm Noise Floor
• Large High-Resolution Display: Full Color, Indoor/Outdoor Viewable
• Easy-to-Use: Intuitive Menus, One-Button Setup, and On-Board Help
• Long Battery Life: 5.5 Hours per Charge, Field Replaceable Battery
• Rugged: Drop Tested per Military and European Standards
• USB Connectivity: USB Drive Stores 40,000 Traces
• Wideband 5012: 350 MHz to 4 GHz, 150 mW
to 150 W average, 400 W peak, Forward
• Directional 5010B: 450 kHz to 2.7 GHz,
100 mW to 10 kW, Forward and Reflected
• Terminating 5011: 40 MHz to 4 GHz,
10 uW to 10 mW, 50 W Attenuator Option
Model 5010B
Directional Power Sensor
Model 5011
Model 5012
Wideband Power Sensor
WIDEBAND POWER SENSOR (MODEL 5012) (See page 13)
Wideband Power Sensor, 350 MHz to 4 GHz, 150 mW to 150 W Avg, 400
W Peak. Measures forward and reflected average, VSWR, return loss (dB),
peak, burst average, crest factor and CCDF. Forward average power accuracy is 4% (0.2 dB).
DIRECTIONAL POWER SENSOR (MODEL 5010B) (See page 16)
Directional Power Sensor, 2 to 2700 MHz, 100 mW to 10 kW, requires elements. Measures forward and reflected average, VSWR, return loss (dB),
and peak. Forward average power accuracy is 5% (0.2 dB).
TERMINATING POWER SENSOR (MODEL 5011) (See page 14)
Terminating Power Sensor, 40 MHz to 4 GHz, 10µW to 10 mW (-20 dBm to
+10 dBm). Measures forward average power.Accuracy is 5% (0.2 dB).
TERMINATING POWER SENSOR (MODEL 5011-EF) (See page 14)
Terminating Power Sensor, 40 MHz to 12 GHz, 10µW to 10 mW (-20 to
+10 dBm) Measures forward average power. Accuracy is 5% (0.2 dB).
Terminating Power Sensor
STANDARD ACCESSORIES
Soft Carrying Case, Quick Start Manual, PC Tool Software CD, Serial Cable,
USB Cable, USB Drive, AC Power Supply, AutomotivePower Adapter,
Headphones, Connector Cover
* Note: Adapter 4240-500-10 required for field strength antenna.
DESCRIPTION
Wideband Power Sensor
Directional Power Sensor
Terminating Power Sensor
Replacement Battery
Replacement USB Drive-WinCE compatible
Attenuator, 50 W, 30 dB, N(M)/N(F)
Attenuator, 10 W, 30 dB, N(M)/N(F)
Attenuator, 2 W, 20 dB, N(M)/N(F)
Attenuator, 100 W, 40 dB, N(M)/N(F)
Attenuator, 25 W, 30 dB, N(M)/N(F)
Attenuator, 5 W, 20 dB, N(M)/N(F)
Test Cable, 1.5 m, N(M)/N(F)
Test Cable, 3.0 m, N(M)/N(F)
Test Cable, 1.5 m, N(M)/N(M)
Test Cable, 3.0 m, N(M)/N(M)
Test Cable, 1.5 m, N(M)/DIN(F)
Test Cable, 3.0 m, N(M)/DIN(F)
Test Cable, 1.5 m, N(M)/DIN(M)
Test Cable, 3.0 m, N(M)/DIN(M)
Adapter, N(M)/DIN(M)
Adapter, N(F)/DIN(M)
Adapter, N(M)/DIN(F)
Adapter, N(F)/DIN(F)
Adapter Kit, 7/16 DIN
Adapter, N(F)/N(F)
Adapter, N(M)/N(M)
Adapter, N(M)/SMA(F)
Field Strength Antenna, 136 to 221MHz, SMA(M)
Field Strength Antenna, 400 to 512MHz, SMA(M)
Field Strength Antenna, 824 to 894MHz, SMA(M)
Field Strength Antenna, 890 to 960MHz, SMA(M)
Field Strength Antenna, 1710 to 1880MHz, SMA(M)
Field Strength Antenna, 1850 to 1990MHz, SMA(M)
Field Strength Antenna, 2400 to 2500MHz, SMA(M)
Hard Transit Case
USB Mouse, Portable, Optical
USB HUB, 4 Port, Ultra Mini
www.bird-technologies.com 1-866-695-4569
®
Electronic Corporation
Bird
4
Antenna and Cable Testing
Model SA-6000EX, Model SA-2500EX, Model SA-1700EX & Model SA-1700EXP
SITE ANALYZER®SERIES
Site Analyzer
MODEL SA-6000EX (25 - 6000 MHz), MODEL SA-2500EX (780 - 2500 MHz),
MODEL SA-1700EX (25 - 1700 MHz), MODEL SA-1700EXP (25 - 1700 MHz)
• ONE UNIT covers the entire 25-6000 MHz range!
• Easy to operate and field ready for first-time, occasional and experienced users.
• Suitable for use in Worldwide Cellular and PCS/DCS; supporting
measurement of CDMA, GSM,TDMA and AMPS modulation schemes.
• Other applications include 3G, Broadcast, Government, Tactical Military, Microwave,
Paging, Public Safety, Trunking, WLAN and WLL, and TETRA (see model matrix).
• Color display is clearly visible in direct sunlight
• WIth a single download you can view as Distance to Fault or Measurement
Match-no need to store two traces.
• FDR (Frequency Domain Relectrometry) measurement method results in a
highly reliable assessment of the health of critical components in your
system; ultimately providing a “heads-up” before a failure occurs.
• Fault location or DTF mode indicates VSWR or Return Loss levels at each
point along the cable and antenna system length.
• Cable Loss function measures insertion loss of the cable system over a
given frequency range.
®
Bird's
Site Analyzer®is the user-friendly test solution for installing, maintaining,
and troubleshooting your antenna and cable systems. Field engineers and
technicians rely on this rugged handheld tool to get the job done. Wireless
equipment manufacturers, service providers, contractors, tower erectors,
and military field personnel world wide approve of the analyzer's precision
VSWR and Return Loss results.
This versatile unit also includes a Digital Power Meter option to accurately measure the output power of your base station. Wideband
Power Sensors are available from Bird up to 4 GHz for use with this option, and are listed with the Accessories.
Model SA-6000EX, Model SA-2500EX, Model SA-1700EX & Model SA-1700EXP
DIGITAL POWER METER OPTION
Site Analyzer
Digital Power Meter option allows accurate power readings for
digital or analog systems including those with CDMA, GSM, TDMA
or AMPS modulation. Operators of analog and digital two-way radio
systems, including tactical military users, will benefit as well.
• Compatible with the Model 5010B Directional Power Sensor to
display forward and reflected power as well as VSWR and
STANDARD ACCESSORIES
The Site Analyzer®includes Carrying Case, Instruction
Manual, Serial Cable, PC Tool Software for Windows, AC
Power Supply and Automotive Power Adapter.
Return Loss, DPM elements range from 2 MHz - 2700 MHz.
• Compatible with the Model 5011 Terminating Power Sensor
to measure power directly or via a coupled test port from
40 MHz - 4000 MHz.
• Compatible with the Model 5012 Wideband Power Sensor to
display forward and reflected power 350 MHz - 4000 MHz.
Digital Power Meter option included with SA-6000EX,
SA-2500EX and SA-1700EXP.
Antenna and Cable Testing
®
Standard
Accessories
Calibration
Combos
Model SA-2500EX
Site Analyzer®with
Digital Power Option
WIDEBAND POWER SENSOR (MODEL 5012) (See page 13)
The Model 5012 provides customers a TOTAL RF POWER MEASUREMENT
SOLUTION for Directional Power Measurement with Accuracy of ±5% of
readings.
DIRECTIONAL POWER SENSOR (MODEL 5010B) (See page 16)
The Model 5010B provides customers a TOTAL RF POWER MEASUREMENT
SOLUTION for Thruline®(In-line) Power Measurements with Accuracy of
±5% of readings.
NEW TERMINATING POWER SENSOR (MODEL 5011) (See page 14)
The Model 5011 provides customers a TOTAL RF POWER MEASUREMENT
SOLUTION to measure Base Station Power and/or Broadcast Transmitter
Power with Accuracy of ±5% of readings.
ACCESSORIES
Model Description
CAL-MN-CCalibration combo, (M) N
CAL-FN-CCalibration combo, (F) N
CAL-ME-CCalibration combo, (M) 7/16 DIN
CAL-FE-CCalibration combo, (F) 7/16 DIN
5012Wideband Power Sensor 350 - 4000MHz
5011Terminating Power Sensor 40 - 4000MHz
5010BDirectional Power Sensor 2 - 2700MHz
TC-MNMN-1.5Test cable, 1.5 m., N (M) conn.
TC-MNMN-3.0Test cable, 3 m., N (M) conn.
TC-MNFN-1.5Test cable, 1.5 m., N (M)/N (F) conn.
TC-MNFN-3.0Test cable, 3 m., N (M)/N (F) conn.
TC-MNME-1.5 Test Cable, 1.5m, N(M) - 7/16 DIN (M)
TC-MNME-3.0Test Cable, 3.0m, N(M) - 7/16 DIN (M)
TC-MNFE-1.5Test cable, 1.5 m., N (M)/7/16 DIN (F) conn.
TC-MNFE-3.0Test cable, 3 m., N (M)/7/16 DIN (F) conn.
PA-MNMEAdapter, N (M) to 7/16 DIN (M)
PA-FNMEAdapter, N (F) to 7/16 DIN (M)
PA-MNFEAdapter, N (M) to 7/16 DIN (F)
PA-FNFEAdapter, N (F) to 7/16 DIN (F)
4240-550 Precision Connector Adapter Kit,
7/16 DIN, SA-Series
7002C870Hard shell transit case
SA-BATPAKExternal battery pack
DC-DB9 USBSerial-USB Adapter
Model 5010B
Directional Power Sensor
Model 5011
Terminating Power Sensor
www.bird-technologies.com 1-866-695-4569
Model 5012
Wideband Power Sensor
®
Bird
Electronic Corporation
6
Antenna & Cable Testing
MinimizeMinimize
DowntimeDowntime
Minimize
Downtime
Keep Your Critical
Antenna Sites
Up & Running
Antenna & Cable Monitor
BIRD®ANTENNA & CABLE MONITOR
Bird
Cable Monitor
Accurately detects antenna system degradation and failures
• Compatible with analog or digital cellular and two-way radio systems
®
Antenna
• Worldwide applications include Tetra, Cellular, PCS and many others
• Monitors VSWR and power levels and provides alarm outputs
• Sensitive to antenna faults that internal transmitter VSWR monitors may not detect
• Local or remote operation via PC software
• Ideal for multi-carrier applications
FORWARD POWER MEASUREMENT
REFLECTED POWER MEASUREMENT
VSWR ALARM CHARACTERISTICS
MODEL NUMBER DEFINITION
Frequency Range*136* - 225 MHz
225 - 520 MHz
470 - 960 MHz
960 - 2400 MHz
Measurement Range2.5 - 100 W, contact factory to inquire about
other power measurement ranges
Power Accuracy±5% of reading, ±1 count
Insertion Loss 0.1 dB, 136 - 960 MHz
0.15 dB, 960 - 2400 MHz
VSWR 1.07, 136 - 960 MHz
1.1, 960 - 2400 MHz, N Connectors
1.1, 960 - 2000 MHz, 7/16 Connectors
1.2, 2000 - 2400 MHz, 7/16 Connectors
Directivity 30 dB, 136 - 960 MHz
26 dB, 960 - 2400 MHz
Alarm Set Point1.3, 1.4, 1.5, 1.6, 1.7, 1.8 to 1
Relay Contact TypeDry, Form C, relay contacts,
common, normally open, normally closed.
Contact Rating 100 VDC @ 0.5 A
Visual Alarm Red LED will illuminate to indicate alarm
StimulusVSWR set point exceeded, response time
proportional to overload.
ResetLocal Mechanical reset switch.
Remote input (Reset if VDC is 0 to +0.8 volts).
Monitor Ports - ConnectorsFemale N, TNC or BNC
Coupling-63 dB approx.,
Subject to changes in full-scale power
Interface Port - ConnectorFemale DB-9, compatible with IBM PC AT serial port.
ProtocolSerial RS-232, 9600 baud, no parity, 8
data bits, 1 stop bit, no handshake.
*Other frequencies & power ranges available - contact factory.
ACM-RACK 19" rack shelf, mounts up to two Antenna &
ACM-RACKU 19" rack shelf with universal power supply
Input Voltage
L = + (11 to 26) VDC
H = ± (36 to 72) VDC
nectors) 4.2” (107 mm) high, 1.06“(27 mm) deep
EMCEuropean Standard EN 61326-1:1997+
Addendums A1: 1998 and A2: 2001Electrical equipment for measurement, control
and laboratory use
Safety Requirements - Electrical equipment for
measurement, control and laboratory useECM reqirements
readings and alarms, controls alarm set points
Cable Monitors
(100 to 240 VAC, 50 - 60 Hz), mounts up to
two +12 to +26 VDC Antenna & Cable
Monitors
(Contact factory to inquire about other
optional accessories. Specifications are
subject to change.)
Options
Any combination of male or female N or 7/16
DIN input/output connector, female N or TNC
coupler connector,or +11 VDC to +25 VDC or
±36 VDC to ±72 VDC power supply.
PC Software Tool
7005A970
(Optional Accessory)
FAB-READY
CAL CART
Laboratory Grade Instruments
Calibration Cart
BIRD®CALIBRATION CART
Calibration Cart
Turnkey RF Measurements at Your Fingertips
• Stainless steel mobile cart with locking wheels
• High return loss ensures minimal power measurement
error contribution
• Available in international and domestic versions
• Frequency and power upgrades available
(Contact factory for more details)
• Service plans available with Bird®Service Center
The SCC7 Series provides quality turnkey calibration for fab houses
and equipment suppliers. The system consists of (1) 4421 Power Meter,
(1) Power Sensor, (1) Oil Load, (1) Mobile Cart, and Minor Accessories.
4020 Series Power Sensor
ModelFrequency RangePower Input
40211.8-32 MHz300 mW to 1 kW (1.2 kW max.)
402225-1000 MHz300 mW to 1 kW (1.2 kW max.)
40241.5-32 MHz3 W to 10 kW (12 kW max.)
4025100-2500 kHz3 W to 10 kW (12 kW max.)
4027A Series Power Sensor
ModelFrequency RangePower Input
4027A250K250-400 kHz3 W to 10 kW
4027A400K400-550 kHz3 W to 10 kW
4027A800K800-950 kHz3 W to 10 kW
4027A2M1.5-2.5 MHz3 W to 10 kW
4027A4M3-5 MHz3 W to 10 kW
4027A10M10-15 MHz3 W to 10 kW
4027A12M10-15 MHz300 mW to 1kW
4027A25M25-30 MHz3 W to 9 kW
4027A35M35-45 MHz3 W to 7.5 kW
4027A60M45-65 MHz3 W to 6 kW
4027A100M95-105 MHz3 W to 4 kW
4027A150M150-170 MHz3.75 W to 3.75 kW
4027F Series Filtered Power Sensor
ModelFrequency RangePower Input
4027F2M1.8-2.2 MHz100 W to 10 kW
4027F10M12-15 MHz100 W to 10 kW
High Power Loads
ModelFrequency Range & VSWRPower Rating
8251DC to 1 GHz at 1.1 max.1000 W continuous
8890-300DC to 1 GHz at 1.1 max.2500 W continuous
1 GHz to 2 GHz at 1.25 max.
2 GHz to 2.4 GHz at 1.3 max.
8921DC to 1 GHz at 1.1 max.5000 W continuous
8931-115DC to 400 MHz at 1.15 max.10 kW continuous w/ blower on
400 MHz to 1 GHz at 1.20 max.2.5 kW continuous w/ blower off
8931-230DC to 400 MHz at 1.15 max.10 kW continuous w/ blower on
400 MHz to 1 GHz at 1.20 max.2.5 kW continuous w/ blower off
Ultra-Stable SC13 Loads
ModelFrequency Range & VSWRPower Rating
8865SC13DC to 28 MHz at 1.1 max.1 kW
(VSWR less than 1.05:1)
8890-300SC13DC to 28 MHz at 1.1 max.2.5 kW
(VSWR less than 1.05:1)
8921SC13DC to 28 MHz at 1.1 max.5 kW
(VSWR less than 1.05:1)
8931-115SC13DC to 28 MHz at 1.1 max.10 kW, 115 V
(VSWR less than 1.05:1)
8931-230SC13DC to 28 MHz at 1.1 max.10 kW, 230 V
(VSWR less than 1.05:1)
Fully
Assembled
FAB-READY
FAB-READY
CAL CART
CAL CART
Power Levels 1, 2.5, 5, 10 kW
Meter 4421
Sensor Options 4020 Series or 4027A Series
Load Options 8251, 8890-300, 8921,
Impedance 50 ohm
Frequency Range 4020 Sensor 100 kHz - 1000 MHz
Frequency Range 4027A Sensor 250 kHz - 65 MHz
Accuracy 4020 Series ±3% (1) across power and
Accuracy 4027A Series ±1% (1) at calibration
Accuracy 4027F Series ±1% (2) across power and freqency
Casters 4 locking swivel
Connector Type *Customer Specified
Operating Position Vertical only
Power Requirements 115/230 VAC, ±10%, 50/60 Hz
Ambient Temp Range 0ºC to 45ºC
Storage Temperature -20ºC to +70ºC
Humidity 85% Max., Non condensing
Altitude Load derated above 5,000 feet
5 kW & 10 kW Size/Weight 52" L x 20" W x 42" H /
1 kW & 2.5 kW Size/Weight 42" L x 20" W x 42" H /
Material of Construction Stainless steel cart
Applicable Standards CE pending
*For connector options, please refer to our catalog or contact sales
at 866.695.4569 or sales@bird-electronic.com
www.bird-technologies.com 1-866-695-4569
8931-115, 8931-230
frequency range
frequency and power levels;
±2% (1) over remainder of power
range, and at other than
calibration frequencies
range;
±2% (2) over remainder
(For 10 kW 0°C to +40°C)
250 lbs. Fully assembled
175 lbs. Fully assembled
Bird
®
Electronic Corporation
8
Laboratory Grade Instruments
Multi-Sensor Calibration Cart &
High Power Calibration Cart
BIRD®MULTI-SENSOR CALIBRATION CART
Turnkey RF Measurements at Your Fingertips
• Stainless steel mobile cart with locking wheels
• High return loss ensures minimal power measurement error contribution
• Available in international and domestic versions
• Frequency and power upgrades available (Contact factory for more details)
• Service plans available with Bird®Service Center
The MSCC7 Series provides quality turnkey calibration for fab houses and
equipment suppliers. The system consists of (1) 4421 Power Meter,
(2) Power Sensors, (1) Oil Load, (1) Mobile Cart, and Minor Accessories.
4020 Series Power Sensor
ModelFrequency RangePower Input
40211.8-30 MHz300 mW to 1 kW (1.2 kW max.)
40241.5-30 MHz3 W to 10 kW (12 kW max.)
4025100-2500 kHz3 W to 10 kW (12 kW max.)
4027A Series Power Sensor
ModelFrequency RangePower Input
4027A250K250-400 kHz3 W to 10kW
4027A400K400-550 kHz3 W to 10kW
4027A800K800-950 kHz3 W to 10kW
4027A2M1.5-2.5 MHz3 W to 10kW
4027A4M3-5 MHz3 W to 10kW
4027A10M10-15 MHz3 W to 10kW
4027A12M10-15 MHz300 mW to 1kW
4027A25M25-30 MHz3 W to 9 kW
Power Levels 5 kW or 10 kW for either sensor
Meter 4421
Sensor Options 4020, 4027A, or 4027F Series
Load Options 8921A100, 8931A400-115, 8931A400-230
Impedance 50 ohm
Frequency Range 100 kHz - 30 MHz (depending on sensor)
Accuracy 4020 Series ±3% (1)
Accuracy 4027A Series ±1% (1)
Accuracy 4027F Series ±1% (2)
Casters 4 locking swivel
Connector Type *Customer Specified
Operating Position Vertical only
Power Requirements 115/230 VAC, ±10%, 50/60 Hz
Ambient Temp Range 0ºC to 35ºC (For 10 kW 0°C to +40°C)
Storage Temperature -20ºC to +70ºC
Humidity 85% Max., Non condensing
Altitude Load derated above 5,000 feet
5 kW & 10 kW Size/Weight 52" L x 20" W x 42" H /290 lbs. Fully assembled
Material of Construction Stainless steel cart
Applicable Standards CE
*For connector options, please refer to our catalog or contact sales at
866.695.4569 or sales@bird-electronic.com
4027F Series Filtered Power Sensor
ModelFrequency RangePower Input
4027F2M1.8-2.2 MHz100 W to 10 kW
4027F10M12-15 MHz100 W to 10 kW
High Power Loads for Semiconductor
ModelFrequency Range & VSWRPower Rating
8921A1005 kW
8931A400-11510 kW
8931A400-23010 kW
DC to 30 MHz at 1.1 max.
(less than 1.05 typical)
BIRD®HIGH POWER CALIBRATION CART
• Stainless steel mobile cart with locking wheels
• High return loss ensures minimal power measurement
error contribution
• Available in international and domestic versions
• Service plans available with Bird®Service Center
The SCC8 Series provides quality turnkey calibration for fab houses and
equipment suppliers. The system consists of (1) 4421 Power Meter,
(1) 4028 A or B Series Power Sensor, (1) Moduload, (1) Mobile Cart,
and Minor Accessories.
Frequency Range1.8-32 MHz25-1000 MHz1.5-32 MHz100-2500 kHz
Insertion Loss<0.05 dB<0.05 dB<0.05 dB<0.05 dB
Accuracy ±3% of reading from rated max. to rated min.
BIRD®MODEL 4421
Precision Power Meter for Semiconductor Processing Applications
• ±1% Accuracy - Accomplished through the use of sensors with an
automatic frequency compensation scheme, where the error contributions due to directional coupler frequency response characteristics are
eliminated.
• Wide Dynamic Range - The instrument will meet the full accuracy
specification over a 35 dB dynamic range.
• Excellent Measurement Repeatability - Typically <0.1%
• Digital Display - Along with automatic VSWR calculation
• Computer Interface - RS-232 and IEEE-488 standard
The Bird®Model 4421 is a precision RF power meter that, while
originally intended for general purpose laboratory applications where
high accuracy is required, has found wide acceptance in semiconductor
processing applications. The product is configured as a system,
consisting of the Model 4421 digital display and a precision power
sensor selected for the application based upon maximum power
and operating frequency.
Model 4421
MODEL 4421 MULTIFUNCTION POWER METER
Power Range 100 mW to 25 kW FS
Frequency Range 100 kHz - 1 GHz
VSWR Range 1.0 - 199.9
Functions Forward and reflected power in W or dBm, VSWR,
return loss in dB and min./max. values
Overrange Audible warning when RF power input exceeds
120% of sensor's maximum power range
Indication Display 3 1/2 digit-liquid crystal display with indicator
for mode, measurement units, battery condition,
programming status, and trend arrows.
Switchable backlight.
Operating Power 115/230 VAC, 50/60 Hz or 8 nickel metal hydride
1.2 V cells (NEDA type 10014)
Nominal Size 12 9/32" L x 12 5/32" W x 4 1/4" H
(312 mm x 309 mm x 108 mm)
with handle extended 15 7/16" L (392 mm)
Weight 11 lbs. (5 kg.)
Interconnects 1 meter latch-n-lock coiled cable
Interfaces IEEE-488 and RS-232 standard
Dimensions 4 1/2" x 6 1/2" (114 x 165 mm)
Required Product RF Power Sensor
Accessories Case 4300A215 (page 43)
19” Panel Mount Kit 4421-250
Latch & Lock Case 4421-038
MODEL 4421A530 CALIBRATION KIT
Calibration Key
Weight 3 oz. (85 g.)
Cable Length Approx. 3 ft. (1 m)
Required Products 4421 power meter, 4020 Series power sensor,
RF power source, RF low-pass filter, RF terminating
power standard (Bird®Model 6091 calorimeter
recommended) and IBM compatible computer
fitted with a GPIB card-specify standard.
Performance
Measurement Cycle 1 Year
Limitation Not compatible with 4027 Series Sensor
www.bird-technologies.com 1-866-695-4569
®
Electronic Corporation
Bird
10
Laboratory Grade Instruments
±1%1%
ACCURACYACCURACY
Model 4027A Power Sensor
BIRD®Model 4027A
Precision Power Sensors for Precision Process Applications
Achieves tighter, more consistent RF power measurements for
improved yield.
• ±1% accuracy at specified calibration frequencies and power levels.
• Direct, plug-in operation with the industry standard Bird® Model 4421
RF Power Meter.
• Multiple sensors provide for measurement of 0.3 W - 10 kW over a
250 kHz - 170 MHz frequency range.
Bird's®new 4027A Series Power Sensors represent a family of
sensors for use in semiconductor processing and other precision process
applications. Intended for use with the industry standard Bird®Precision
Laboratory Power Meter Model 4421, these products provide a threefold
improvement in long-term unit-to-unit accuracy.
High Power, Precision Power Sensors for Precision
Process Applications
Achieves tighter, more consistent RF power measurements
for improved yields.
• ± 2% at calibration frequencies and power levels.
± 4% at other frequencies and power levels. Add 2% to
uncertainty outside 25 ± 10 °C.
• Direct, plug-in operation with the industry standard
Bird® Model 4421 RF Power Meter.
• Multiple sensors provide for measurement over a 250 kHz to 30 MHz frequency range
• Capable of power measurements up to 50kW.
With the expanding surface areas in the LCD and Solar panel industry, higher power levels are necessary for the industries
processes. The Bird 4028 series sensor is designed to meet the growing RF power measurement challenge with accuracy,
repeatability and versatility to meet current and future applications. Bird continues to innovate useful sensor technology to
meet these fast paced markets.
±4% at other frequencies and power levels. Add 2% to
uncertainty outside 25 ± 10°C
all other units: 3.5kW
and power levels.
Speed 2 readings per second.
4028AxxM: 25kW
4028B: 25kW
4028C: 50kW
±2% (1) at calibration frequencies and power levels; ±4% at other frequencies and power levels.
Add 2% to uncertainty outside 25 ± 10°C
250 and 400kHz units: 1.7kW; all other units: 3.5kW
0°C to 50°C (32°F to 122°F)
-20°C to 70°C (-4°F to 158°F)
POWER REQUIREMENTS
External DC 12 VDC, supplied from Bird 4421 Power Meter
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature 0°C to 50°C (32°F to 122°F)
(derate accuracy outside 25 ± 10°C)
Storage Temperature -20°C to 70°C (-4°F to 158°F)
Humidity 95% non-condensing
Altitude 10,000 feet (3,000 m)
General EMC Designed to carry CE mark (with immunity
exception noted below)
Emissions EN-55011, 1991, Class B
Immunity EN-50082-1, 1995
Safety EN-61010, 1993 in accordance with Council
Directives 73/23/EEC and 93/68/EEC
Calibration Cycle 6 months
www.bird-technologies.com 1-866-695-4569
®
Electronic Corporation
Bird
12
Power Measurement
Model 5012 Wideband Sensor
and vDPM Software
Wideband
BIRD®Model 5012
Bird's®Site Management Solutions for Power Measurement
Power Sensor
• Easy to use & competitive price
• Wide frequency range (350 MHz - 4000 MHz)
• Direct connection to PC, Digital Power Meter or Site Analyzer®- NO BLACK BOX !!!!
• 30 dB Directivity-Up to 3 GHz; 28 dB up to 4 GHz
• Directional-Forward and Reflected Power
• No elements required!
When combined with a Digital Power Meter, Site Analyzer®Family of line and antenna
analysis products, or a Personal Computer, the Wideband Power Sensor becomes an
integral part of a very robust and sophisticated power measurement solution.
Sensor Characteristics - General
Power Measurement Range 0.15 W - 150 W average, 400 W peak
Reflection Measurement Characteristics
Interface Specifications:
Power Requirements
Power Measurement Characteristics
Power Measurement 2.0 W - 150 W10 W - 150 W 4.0 W - 150 W4.0 W - 400 W0.1 - 100%
Peak/Average Ratio12 dB max.––––
Repetition Rate–15 Hz min.–––
Threshold Level Range––––4 W to 400 W
Level Set Accuracy––––±5% of level ±0.5 W
Measurement
Frequency Range 350 MHz - 4 GHz
Impedance 50 ohm (nominal)
Insertion Loss <0.05 dB up to 1 GHz,
Insertion VSWR <1.05 up to 2.5 GHz,
Input Connector N Female
Output Connector N Female
Directivity 30 dB up to 3.0 GHz, 28 dB up to 4.0 GHz
Measurement Range Return Loss, 0.0 to 23 dB
Minimum Forward Power 0.5 W
DC input connector7-18 VDC at less than 0.1A
Range
Burst Width–
Duty Cycle–
Uncertainty
Weight 1.2 lb. max.
DPM Interface EIA-232, 9600 Baud, no parity,
PC Interface(1) EIA-232, 9600 Baud, no parity,
PC Interface(2) USB 1.1 compliant interface
USB port Less than one low-power USB load
(+15°C to +35°C)Duty Cycle Entered, (+15°C to +35°C)power uncertainty(+15°C to +35°C)
BIRD®Model 5011 & 5011-EF Terminating Power Sensor
Terminating
Designed to make Terminating Power Measurements with the full flexibility
of a portable precision instrument
(Requires Bird®MODEL 5000EX, SA-6000EX,
SA-2500EX or SA-1700EXP)
Power Sensor
Significant cost and time savings, easy to use and field ready
•
No calibration and no elements required
•
Both digital as well as analog modulations including
•
(CDMA, GSM, TDMA, 8-VSB and COFDM)
Broadcast Transmitter Power with accuracy of ±5% of readings
•
Measure power directly or via coupled test port
•
Power Measurement
Model 5011 Terminating Sensor
Model 5011
Terminating Power Sensor
SPECIFICATIONS
Sensor Type Terminating Power Sensor. Terminated
Frequency Range 5011 - 40 MHz - 4 GHz
Power Range -20.000 to +10.000 dBm (10.000 µW to 10.000 mW)
Peak/Average Ratio 12 dB max.
* When operating below 100 MHz and above 40°C, add 1%.
NOTE: The Bird
(SA-6000EX, SA-2500EX, or SA-1700EXP) is required.
Accuracy ±5% of reading ±1mW RSS (excluding mismatch
Warm Up Time 5 Minutes
Input Impedance 50 ohm (nominal)
Input VSWR 5011 -Typical 1.03 (36.6 dB return loss); maximum 1.20
Input Connector Precision N Male
Output Connector Male DB-9 to interface to Digital Power Meter or
Power Supply From host instrument via cable connection
Operating Temp. -10°C to 50°C (14°F to 122°F)
Storage Temp. -40°C to 80°C (40°F to 176°F)
Humidity 95% maximum (non-condensing)
Altitude 15,000 ft operating
Weight 3/4 lb. max.
®
Model 5000-EX or the Bird®Site Analyzer®Series
average power measurement.
5011EF - 40 MHz to 12 GHz
uncertainty)*
(20.8 dB return loss)
5011-EF -Typical 1.05 (32.3 dB return loss); maximum
1.25 (19.1 dB return loss)
Site Analyzer
Size 6" long (including connectors); 1.5" diameter
®
ACCESSORIES
Model Description
8353A040-50** Attenuator, 50 W, 40 dB, N (F) to
8353A030-10 Attenuator, 10 W, 30 dB, N (F) to
5011-CALDATA Calibration Data for TPS 5011 Attenuators
4240-500-1 Adapter, N (F) to N (F)
4240-500-3 Adapter, right angle, N (F) to N (M)
4240-500-4 Adapter, N (F) to SMA (F)
4240-500-5 Adapter, N (F) to SMA (M)
PA-FNME Adapter, N (F) to 7/16 DIN (M)
PA-FNFE Adapter, N (F) to 7/16 DIN (F)
TC-MNFN-1.5-G Test cable, 1.5 m., N (M)/N (F) conn.
TC-MNFN-1.5 Test cable, armored, PS, 1.5 m.,
TC-MNFN-3.0 Test cable, armored, PS, 3.0 m.,
N (F) to N (M)
5011A035-1 DC Block, N (F) to N (M)
**Optional 40 dB attenuator provides 100 mW to 50 W capability, other
ranges also available.
COMPATIBLE DEVICES
5000-EX Digital Power Meter
SA-6000EX Site Analyzer
SA-2500EX Site Analyzer
SA-1700EXP Site Analyzer
SH-36S SignalHawk
N (M) 100 mW to 50 W with TPS 5011
N (M) 10 mW to 10 W with TPS 5011
and Accessories.
N (F) to N (M)
®
,
Antenna, & Cable Tester
®
,
Antenna, & Cable Tester
®
,
Antenna, & Cable Tester
®
,
Spectrum Analyzer
www.bird-technologies.com 1-866-695-4569
®
Electronic Corporation
Bird
14
Power Measurement
Wideband Coupler
Wideband
BIRD®Wideband Coupler
Cost effective
•
Portable
•
Easy-to-use
•
SPECIFICATIONS
Frequency Range 45 MHz - 230 MHz (VHF Models)
Maximum Power Transmission line and frequency dependent
Nominal Coupling Transmission line dependent (See Table 1)
Directivity 28 dB Min.
Coupler Output
Connector Type “N” Female
Coupler Output
Main Line VSWR 1.1 Max.
Coupling Uncertainty
(after correction) ±0.05 dB
Operating Temp. -10°C to 40°C
Storage Temp. -20°C to 85°C
Weight Transmission Line Dependent (See Table 2)
Dimensions Transmission Line Dependent (See Table 2)
TABLE 1
Line SizeVHFUHF
1-5/8"62 dB ±2 dB59 dB ±2 dB
3-1/8"69 dB ±2 dB64 dB ±2 dB
4-1/16"70 dB ±2 dB67 dB ±2 dB
6-1/8"75 dB ±2 dB75 dB ±2 dB
is a precision 50-ohm 7/8-inch “Smart” Line Section which accepts
Bird®digital-ready Plug-in DPM Elements. The
true average and peak power readings for digital as well as traditional analog RF systems.
The
Model 5010B Power Sensor
is compatible with many existing Bird®accessories for 7/8" line,
including signal samplers, and over 20 types of QC connectors. QC Connectors can be changed rapidly
and conveniently in the field by removing four screws from the connector.
Model 5010B Sensor
provides
Model 5010B
Thruline®Directional
Power Sensor
*DPM Element Guide
Frequency ForwardReflectedForward Reflected
RangePower RangePower RangeElementElement
2 - 30 MHz
25 - 60 MHz
50 - 125 MHz12.5 W to 500 W1.25 W to 50 WDPM-500BDPM-50B
100 - 250 MHz12.5 W to 500 W1.25 W to 50 WDPM-500CDPM-50C
200 - 500 MHz1.25 W to 50 W125 mW to 5 WDPM-50DDPM-5D
400 - 960 MHz2.5 W to 100 W250 mW to 10 WDPM-100EDPM-10E
950 - 1260 MHz
1100 - 1800 MHz
1700 - 1990 MHz
1900 - 2200 MHz
2200 - 2300 MHz
2300 - 2500 MHz125 mW to 5 W 12.5 mW to 500 mWDPM-5NDPM-.5N
2500 - 2700 MHz125 mW to 5 W 12.5 mW to 500 mWDPM-5RDPM-.5R
1.25 W to 50 W125 mW to 5 WDPM-50HDPM-5H
12.5 W to 500 W1.25 W to 50 WDPM-500HDPM-50H
1.25 W to 50 W125 mW to 5 WDPM-50ADPM-5A
12.5 W to 500 W1.25 W to 50 WDPM-500ADPM-50A
1.25 W to 50 W125 mW to 5 WDPM-50BDPM-5B
25 W to 1 kW2.5 W to 100 WDPM-1000BDPM-100B
1.25 W to 50 W125 mW to 5 WDPM-50CDPM-5C
62.5 W to 2.5 kW6.25 W to 250 WDPM-2500CDPM-250C
125 mW to 5 W 12.5 mW to 500 mWDPM-5DDPM-.5D
12.5 W to 500 W1.25 W to 50 WDPM-500DDPM-50D
125 mW to 5 W 12.5 mW to 500 mWDPM-5EDPM-.5E
1.25 W to 50 W125 mW to 5 WDPM-50EDPM-5E
12.5 W to 500 W1.25 W to 50 WDPM-500EDPM-50E
25 W to 1 kW2.5 W to 100 WDPM-1000EDPM-100E
125 mW to 5 W 12.5 mW to 500 mWDPM-5JDPM-.5J
1.25 W to 50 W125 mW to 5 WDPM-50JDPM-5J
125 mW to 5 W 12.5 mW to 500 mWDPM-5KDPM-.5K
1.25 W to 50 W125 mW to 5 WDPM-50KDPM-5K
125 mW to 5 W 12.5 mW to 500 mWDPM-5L1DPM-.5L1
1.25 W to 50 W125 mW to 5 WDPM-50L1DPM-5L1
12.5 W to 500 W1.25 W to 50 WDPM-500L1DPM-50L1
1.25 W to 50 W125 mW to 5 WDPM-50L2DPM-5L2
125 mW to 5 W 12.5 mW to 500 mWDPM-5L2DPM-.5L2
625 mW to 25 W 62.5 mW to 2.5 WDPM-25MDPM-2.5M
125 mW to 5 W 12.5 mW to 500 mWDPM-5MDPM-.5M
SPECIFICATIONS
Sensor Type Bird
Frequency Range Element limited. Please view element
Power Range Element limited. Please view element guide
Pulse width >100 MHz 800 ns min.
Parameters 26-99 MHz 1.5 µs min.
Pulse Rep. Rate Peak 15 pps min.
Pulse Duty Factor 1 x 10-4min.
Accuracy TRUE AVERAGE POWER, ±5% of reading (15°C to
Dynamic Range 40:1 (E.G. 50 W element
Peak/Average 10 dB maximum with DPM elements
Power Ratio
Settling Time < 2 seconds
Connectors QC Type. Female N normally supplied.
Insertion VSWR 1.05:1 from 0.45 to 1000 MHz
Dimensions 1.875" H x 1.875" W x 3.5" D
Weight 1.12 lbs. (0.51 kg)
Operating Temp. -10°C to +50°C
Storage Temp. -40°C to +75°C
Humidity 95% max. (non-condensing)
COMPATIBLE DEVICES
5000-EX Digital Power Meter
SA-6000EX Site Analyzer
SA-2500EX Site Analyzer
SA-1700EXP Site Analyzer
SH-36S SignalHawk
®
THRULINE®directional
dual-element line section
guide for current listing.
for current listing. 1 W to 1000 W*
2-25 MHz 15 µs min.
35°C), ±7% of reading (-10°C to 50°C)
PEAK POWER, ±8% of full scale
measure 1.25 W to 50 W).
(with N connectors)
(47.7 mm x 47.7 mm x 88.9 mm)
excluding connectors
®
,
Antenna, & Cable Tester
®
,
Antenna, & Cable Tester
®
,
Antenna, & Cable Tester
®
,
Spectrum Analyzer
* Note: 5010B supercedes 5010
**Note: For average power readings, use the elements listed above in the DPM Element Guide.
For peak power readings, use elements from Tables 1-6 pages 42 & 43.
www.bird-technologies.com 1-866-695-4569
®
Electronic Corporation
Bird
16
Loading...
+ 39 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.