Bird 782-BGC User Manual

General Catalog
Table of Contents
TABLE OF CONTENTS
Spectrum Analysis
Antenna and Cable Testing
Site Analyzer Site Analyzer Site Analyzer
®
6000EX..............................................................................................................................5-6
®
2500EX..............................................................................................................................5-6
®
1700EX and 1700EXP........................................................................................................5-6
Antenna and Cable Monitor..........................................................................................................................7
Antenna Testers ..........................................................................................................................................7
Laboratory Grade Instruments
Calibration Cart............................................................................................................................................8
Dual Sensor & High Power Calibration Carts ................................................................................................9
Model 4421 Power Meter and 4020 Series................................................................................................10
Model 4027A ............................................................................................................................................11
Model 4028 ..............................................................................................................................................12
Power Measurement
Model 5012 Wideband Sensor and vDPM software....................................................................................13
Model 5011 and 5011-EF Terminating Sensor ..........................................................................................14
Wideband Coupler ....................................................................................................................................15
Model 5010B Thruline
®
Sensor ..................................................................................................................16
Model 5000-EX Digital Power Meter ..........................................................................................................17
Broadcast Power Monitor - including the coupler and DPS ........................................................................18
Thruline
®
RF Directional Wattmeters
50-ohm Cable Systems and 7/8” Line
Portable Wattmeters ............................................................................................................................19-22
Wattcher
®
RF Monitoring System ..............................................................................................................22
RF Power Analyst ......................................................................................................................................22
Bus Interface Units and
RF Signal Samplers ..................................................................................................................................23
Field Strength Meter ..................................................................................................................................24
Meter Movements and 7/8” Line Sections ................................................................................................24
1 5/8” - 6 1/8” Rigid Line Systems
Wattcher
®
RF Monitoring System ..............................................................................................................25
Rigid Line Sections ....................................................................................................................................26
Meters for Rigid Line Use ..........................................................................................................................26
Power Termination
Termaline
®
RF Coaxial Termination........................................................................................................27-34
Digital Air Loads ........................................................................................................................................35
13.56 Load ................................................................................................................................................36
Power Attenuators
®
Tenuline
RF Coaxial Attenuators ........................................................................................................37-38
Selector Switches, Couplers, Dividers ................................................................................................39
Elements ............................................................................................................................................40-43
Accessories and Connectors ..........................................................................................................44-46
Technical Information ......................................................................................................................47-50
Product Index ....................................................................................................................................51-52
Bird®Electronic Corporation maintains an aggressive program of testing products for conformity applicable electromagnetic and safety standards, including European Union Directives. We are proud to announce that, where applicable, Bird products carry the “CE” Mark. A CE marked product complies with the relevant EU Directives and is approved for sale in the European Union. The specific standards that were used to evaluate the product compliance are listed on the Declaration of Conformity (DOC).
1 Bird®Electronic Corporation 1-866-695-4569 www.bird-technologies.com
Wireless Market Solutions
Bird®Electronic Corporation provides solutions to the following markets. For your convenience, each product represented in the catalog includes the market icon(s) for your reference. For more application information, please visit our website www.bird-technologies.com.
Market Solutions
Public Safety
Integrated Antenna Analysis
Reliable, Rugged, Power Measurement
Rugged, Versatile Load and Attenuator Kits Available
Government/Military
Integrated Antenna Analysis
Field Testing of Tactical Radio Systems
Power Measurement, Resistive Components and Subassemblies
Rugged, Versatile Load and Attenuator Kits Available
Semiconductor
Precision Power Measurement Solutions and Calorimetric Systems
Highly Stable, Reliable, Terminations, Loads, and Attenuators
Integrated Power Measurement and Load Systems
RF Accessories, Mismatches, Adapters, Subassemblies
Broadcast Market Solutions
Analog and Digital Universal Power Measurement
High Power Digital Load Solutions
Broadcast Accessories
Wireless Market Solutions
Integrated Antenna Analysis
Analog and Digital Universal Power Measurement
Lightweight, Portable Resistive Products
Spread Spectrum
Special Markets
Solutions for Medical, Avionics, Transportation
and Other Markets
Bird®Service Center
Service and Calibration of Bird®Products
www.bird-technologies.com 1-866-695-4569
®
Electronic Corporation
Bird
2
Text Here
Spectrum Analyzer
SignalHawk
SignaHawk
MODEL SH-36S Spectrum Analyzer with Power Meter Option
SIGNALHAWK
TM
Bird Technologies SignalHawkTMAnalyzes radio frequency spectrum. Measures intended and interfering signals. Allows setup of parameters such as frequency, amplitude, and markers. Graphically displays signal amplitude vs. frequency and saves traces.
KEY FEATURES
• Fast, Accurate, and Sensitive: -135 dBm Noise Floor
• Large High-Resolution Display: Full Color, Indoor/Outdoor Viewable
• Easy-to-Use: Intuitive Menus, One-Button Setup, and On-Board Help
• Long Battery Life: 5.5 Hours per Charge, Field Replaceable Battery
• Rugged: Drop Tested per Military and European Standards
• USB Connectivity: USB Drive Stores 40,000 Traces
WORLDWIDE APPLICATIONS
Cellular, PCS, DCS, 2 G, 3 G, CDMA, cdmaOne, CDMA 2000, 1x, 1x EV-DO, GSM, GPRS, EDGE, UMTS, HSDPA, W-CDMA, TDMA, AMPS as well as 802.11, Bluetooth, Broadcast, Emergency, Fire, GPS, HDTV, IBOC, Microwave, NPSPAC, Paging, Police, Private, Project 25, Public Safety, Tactical Military, Telematics, Tetra, Trunking, Utilities, WLAN and WLL.
TM
Model
SH-36S
SignalHawk
TM
SPECTRUM ANALYZER
• 100 kHz to 3.6 GHz
• Low Displayed Average Noise Level
• Interference Identification
• Measurements: Occupied Band Width, Channel Power, Adjacent Channel Power Ratio, Field Strength, AM/FM Demod, C/I, and more.
GENERAL SPECIFICATIONS
CE Compliance YES
Military Specifications MIL-PRF-28800F, Drop & Drip Test
Operating Temperature 0 to 50 °C
Storage Temperature -20 to +80 °C
Humidity, Max 95% non-condensing
Altitude, Max 4600m above sea level
Dimensions 11.5” x 10.5” x 3.8”
Weight, with battery, Max 7.8 lbs
Operating Time 5.5 Hours continuous
Environmental Testing Drop Test, Transit Drop Test, Bench Handling, Vibration,
Shock, Functional, Drip Proof, Salt Exposure, Fungus Resistance
Win CE Viewers Word, Excel, PPT, PDF, Image
INPUT
Test Port N (F)
Impedance, Nominal 50 ohms
VSWR, Nominal 1.8
RF Input, Max. +20 dBm, 30 dBm for 30 sec.
Attenuator 0, 10, 20, or 30 dB; internal
Pre-Amplifier +24 dB gain, internal
FREQUENCY
Range 100 kHz to 3.6 GHz
Resolution 1 Hz
Uncertainty ± 1ppm
Temperature Drift ± 1ppm/°C
Reference Aging ± 1ppm/year
SPECTRAL PURITY
30 kHz from carrier -85 dBc / (RBW Hz) 100 kHz from carrier -100 dBc / (RBW Hz) 100 kHz from carrier -124 dBc / (RBW Hz)
BANDWIDTH
Resolution 100 Hz - 1 MHz in 1,3,10 steps
AMPLITUDE
Measurement Range -135 dBm to +20 dBm
Dynamic Range 66 dB, intermod-free
Noise Floor -135 dBm DANL
Inherernt Spurious -80 dBm
Input Related Spurious -70 dBc
Amplitude Accuracy ±1.0 dB typ, ±1.5 dB max
DISPLAY
Reference Level -140 dBm to +30 dBm, User selectable
Resolution 800 x 600 pixels
Offset Range -99 to 99 dB
Data Points 705 displayed
Sweep Time 2 s, full span; 1 ms, zero span
TRIGGER
Sources Internal, external TTL, internal video
Connector BNC(F)
1/2
1/2
1/2
Video 10 Hz - 1 MHz in 1,3,10 steps
Screen 8.4”, SVGA, indoor/outdoor
or autoscale
Units dBm, µW, mW, W, dBµV, dBmV, dBV, µV,
mV, V, db/m2, µV/m2
3 Bird®Electronic Corporation 1-866-695-4569 www.bird-technologies.com
SignalHawk
TM
Text Here
Spectrum Analyzer
SignalHawk
POWER METER OPTION
• Data Logging
• Optional Power Sensors: 5012, 5010B, 5011
• Wideband 5012: 350 MHz to 4 GHz, 150 mW to 150 W average, 400 W peak, Forward
• Directional 5010B: 450 kHz to 2.7 GHz, 100 mW to 10 kW, Forward and Reflected
• Terminating 5011: 40 MHz to 4 GHz, 10 uW to 10 mW, 50 W Attenuator Option
Model 5010B Directional Power Sensor
Model 5011
Model 5012 Wideband Power Sensor
WIDEBAND POWER SENSOR (MODEL 5012) (See page 13)
Wideband Power Sensor, 350 MHz to 4 GHz, 150 mW to 150 W Avg, 400 W Peak. Measures forward and reflected average, VSWR, return loss (dB), peak, burst average, crest factor and CCDF. Forward average power accu­racy is 4% (0.2 dB).
DIRECTIONAL POWER SENSOR (MODEL 5010B) (See page 16)
Directional Power Sensor, 2 to 2700 MHz, 100 mW to 10 kW, requires ele­ments. Measures forward and reflected average, VSWR, return loss (dB), and peak. Forward average power accuracy is 5% (0.2 dB).
TERMINATING POWER SENSOR (MODEL 5011) (See page 14)
Terminating Power Sensor, 40 MHz to 4 GHz, 10µW to 10 mW (-20 dBm to +10 dBm). Measures forward average power.Accuracy is 5% (0.2 dB).
TERMINATING POWER SENSOR (MODEL 5011-EF) (See page 14)
Terminating Power Sensor, 40 MHz to 12 GHz, 10µW to 10 mW (-20 to +10 dBm) Measures forward average power. Accuracy is 5% (0.2 dB).
Terminating Power Sensor
STANDARD ACCESSORIES
Soft Carrying Case, Quick Start Manual, PC Tool Software CD, Serial Cable, USB Cable, USB Drive, AC Power Supply, AutomotivePower Adapter, Headphones, Connector Cover
Standard Accessories
OPTIONAL ACCESSORIES
MODEL
5012 5010B 5011 5A2720-2 5A2745-1 50-A-MFN-30 10-A-MFN-30 2-A-MFN-20 100-SA-MFN-40 25-A-MFN-30 5-A-MFN-20 TC-MNFN-1.5 TC-MNFN-3.0 TC-MNMN-1.5 TC-MNMN-3.0 TC-MNFE-1.5 TC-MNFE-3.0 TC-MNME-1.5 TC-MNME-3.0 PA-MNME PA-FNME PA-MNFE PA-FNFE 4240-550 4240-500-1 4240-500-2 4240-500-10 ANT-100* ANT-400* ANT-800* ANT-900* ANT-1800* ANT-1900* ANT-2400* 7002C870 USB-Mouse USB-HUB
* Note: Adapter 4240-500-10 required for field strength antenna.
DESCRIPTION
Wideband Power Sensor Directional Power Sensor Terminating Power Sensor Replacement Battery Replacement USB Drive-WinCE compatible Attenuator, 50 W, 30 dB, N(M)/N(F) Attenuator, 10 W, 30 dB, N(M)/N(F) Attenuator, 2 W, 20 dB, N(M)/N(F) Attenuator, 100 W, 40 dB, N(M)/N(F) Attenuator, 25 W, 30 dB, N(M)/N(F) Attenuator, 5 W, 20 dB, N(M)/N(F) Test Cable, 1.5 m, N(M)/N(F) Test Cable, 3.0 m, N(M)/N(F) Test Cable, 1.5 m, N(M)/N(M) Test Cable, 3.0 m, N(M)/N(M) Test Cable, 1.5 m, N(M)/DIN(F) Test Cable, 3.0 m, N(M)/DIN(F) Test Cable, 1.5 m, N(M)/DIN(M) Test Cable, 3.0 m, N(M)/DIN(M) Adapter, N(M)/DIN(M) Adapter, N(F)/DIN(M) Adapter, N(M)/DIN(F) Adapter, N(F)/DIN(F) Adapter Kit, 7/16 DIN Adapter, N(F)/N(F) Adapter, N(M)/N(M) Adapter, N(M)/SMA(F) Field Strength Antenna, 136 to 221MHz, SMA(M) Field Strength Antenna, 400 to 512MHz, SMA(M) Field Strength Antenna, 824 to 894MHz, SMA(M) Field Strength Antenna, 890 to 960MHz, SMA(M) Field Strength Antenna, 1710 to 1880MHz, SMA(M) Field Strength Antenna, 1850 to 1990MHz, SMA(M) Field Strength Antenna, 2400 to 2500MHz, SMA(M) Hard Transit Case USB Mouse, Portable, Optical USB HUB, 4 Port, Ultra Mini
www.bird-technologies.com 1-866-695-4569
®
Electronic Corporation
Bird
4
Antenna and Cable Testing
Model SA-6000EX, Model SA-2500EX, Model SA-1700EX & Model SA-1700EXP
SITE ANALYZER®SERIES
Site Analyzer
MODEL SA-6000EX (25 - 6000 MHz), MODEL SA-2500EX (780 - 2500 MHz), MODEL SA-1700EX (25 - 1700 MHz), MODEL SA-1700EXP (25 - 1700 MHz)
• ONE UNIT covers the entire 25-6000 MHz range!
• Easy to operate and field ready for first-time, occasional and experienced users.
• Suitable for use in Worldwide Cellular and PCS/DCS; supporting measurement of CDMA, GSM,TDMA and AMPS modulation schemes.
• Other applications include 3G, Broadcast, Government, Tactical Military, Microwave, Paging, Public Safety, Trunking, WLAN and WLL, and TETRA (see model matrix).
• Color display is clearly visible in direct sunlight
• WIth a single download you can view as Distance to Fault or Measurement Match-no need to store two traces.
• FDR (Frequency Domain Relectrometry) measurement method results in a highly reliable assessment of the health of critical components in your system; ultimately providing a “heads-up” before a failure occurs.
• Fault location or DTF mode indicates VSWR or Return Loss levels at each point along the cable and antenna system length.
• Cable Loss function measures insertion loss of the cable system over a given frequency range.
®
Bird's
Site Analyzer®is the user-friendly test solution for installing, maintaining, and troubleshooting your antenna and cable systems. Field engineers and technicians rely on this rugged handheld tool to get the job done. Wireless equipment manufacturers, service providers, contractors, tower erectors, and military field personnel world wide approve of the analyzer's precision VSWR and Return Loss results.
This versatile unit also includes a Digital Power Meter option to accurately measure the output power of your base station. Wideband Power Sensors are available from Bird up to 4 GHz for use with this option, and are listed with the Accessories.
®
Model
SA-1700EX
Site Analyzer
Model
SA-6000EX
Site Analyzer
®
®
Model # SA-6000EX SA-2500EX SA-1700EXP SA-1700EX
Frequency Range 25 - 6000 MHz 780 - 2500 MHz 25 - 1700 MHz 25 - 1700 MHz
Frequency Resolution 25 kHz from 25-800 MHz
50 kHz from 800-2500 MHz 50 kHz
150 kHz from 2500-6000 MHz
Power Measurement Yes Yes Yes No
Return Loss 0 to -60 dB
Test Port N-type female connector
Impedance 50
Speed 1 multi-frequency scan - (238 points)/2 seconds; (475 points)/3.5 seconds; (949 points)/6 seconds
Trace Resolution 238 (default), 475, or 949 per trace data points
Storage Capacity 15 Set-Ups/(500) 238 point traces
Immunity to
Interfering Signals
Maximum Input Signal +22 dBm
Data Transfer 9-pin RS-232 (DB9), compatible with serial port
Internal Rechargeable Lithium-Ion batteries. 3-hour minimum operating time. Auto shut-off conserves battery life. External DC 9 to 16 VDC fused, <3A External AC 90 to 264 VAC @ 45-66 Hz; AC/DC adapter required
Operating Temperature -10°C to 50°C (14°F to 122°F)
Storage Temperature -40°C to 80°C (-40°F to 176°F)
Humidity 95% ±5% max., (non-condensing)
Altitude Up to 15,000 feet (4572 m)
Dimensions 10.5" x 8.4" x 3.3" (265 mm x 212 mm x 83 mm)
Weight 5.5 lbs. (2.5 kg)
Upgradeable No Yes, SA-6000EX Yes SA-6000EX Yes, SA-6000EX
5 Bird®Electronic Corporation 1-866-695-4569 www.bird-technologies.com
25 kHz from 25-800 MHz 25 kHz from 25-800 MHz
50 kHz from 800-1700 MHz 50 kHz from 800-1700 MHz
Rejects on-frequency signals up to +13 dBm
Model SA-6000EX, Model SA-2500EX, Model SA-1700EX & Model SA-1700EXP
DIGITAL POWER METER OPTION
Site Analyzer
Digital Power Meter option allows accurate power readings for digital or analog systems including those with CDMA, GSM, TDMA or AMPS modulation. Operators of analog and digital two-way radio systems, including tactical military users, will benefit as well.
• Compatible with the Model 5010B Directional Power Sensor to display forward and reflected power as well as VSWR and
STANDARD ACCESSORIES
The Site Analyzer®includes Carrying Case, Instruction Manual, Serial Cable, PC Tool Software for Windows, AC Power Supply and Automotive Power Adapter.
Return Loss, DPM elements range from 2 MHz - 2700 MHz.
• Compatible with the Model 5011 Terminating Power Sensor to measure power directly or via a coupled test port from 40 MHz - 4000 MHz.
• Compatible with the Model 5012 Wideband Power Sensor to display forward and reflected power 350 MHz - 4000 MHz. Digital Power Meter option included with SA-6000EX, SA-2500EX and SA-1700EXP.
Antenna and Cable Testing
®
Standard Accessories
Calibration Combos
Model SA-2500EX Site Analyzer®with Digital Power Option
WIDEBAND POWER SENSOR (MODEL 5012) (See page 13)
The Model 5012 provides customers a TOTAL RF POWER MEASUREMENT SOLUTION for Directional Power Measurement with Accuracy of ±5% of readings.
DIRECTIONAL POWER SENSOR (MODEL 5010B) (See page 16)
The Model 5010B provides customers a TOTAL RF POWER MEASUREMENT SOLUTION for Thruline®(In-line) Power Measurements with Accuracy of ±5% of readings.
NEW TERMINATING POWER SENSOR (MODEL 5011) (See page 14)
The Model 5011 provides customers a TOTAL RF POWER MEASUREMENT SOLUTION to measure Base Station Power and/or Broadcast Transmitter Power with Accuracy of ±5% of readings.
ACCESSORIES
Model Description
CAL-MN-C Calibration combo, (M) N CAL-FN-C Calibration combo, (F) N CAL-ME-C Calibration combo, (M) 7/16 DIN CAL-FE-C Calibration combo, (F) 7/16 DIN 5012 Wideband Power Sensor 350 - 4000MHz 5011 Terminating Power Sensor 40 - 4000MHz 5010B Directional Power Sensor 2 - 2700MHz TC-MNMN-1.5 Test cable, 1.5 m., N (M) conn. TC-MNMN-3.0 Test cable, 3 m., N (M) conn. TC-MNFN-1.5 Test cable, 1.5 m., N (M)/N (F) conn. TC-MNFN-3.0 Test cable, 3 m., N (M)/N (F) conn. TC-MNME-1.5 Test Cable, 1.5m, N(M) - 7/16 DIN (M) TC-MNME-3.0 Test Cable, 3.0m, N(M) - 7/16 DIN (M) TC-MNFE-1.5 Test cable, 1.5 m., N (M)/7/16 DIN (F) conn. TC-MNFE-3.0 Test cable, 3 m., N (M)/7/16 DIN (F) conn. PA-MNME Adapter, N (M) to 7/16 DIN (M) PA-FNME Adapter, N (F) to 7/16 DIN (M) PA-MNFE Adapter, N (M) to 7/16 DIN (F) PA-FNFE Adapter, N (F) to 7/16 DIN (F) 4240-550 Precision Connector Adapter Kit,
7/16 DIN, SA-Series
7002C870 Hard shell transit case SA-BATPAK External battery pack DC-DB9 USB Serial-USB Adapter
Model 5010B Directional Power Sensor
Model 5011 Terminating Power Sensor
www.bird-technologies.com 1-866-695-4569
Model 5012 Wideband Power Sensor
®
Bird
Electronic Corporation
6
Antenna & Cable Testing
MinimizeMinimize DowntimeDowntime
Minimize Downtime
Keep Your Critical Antenna Sites Up & Running
Antenna & Cable Monitor
BIRD®ANTENNA & CABLE MONITOR
Bird
Cable Monitor
Accurately detects antenna system degradation and failures
Compatible with analog or digital cellular and two-way radio systems
®
Antenna
Worldwide applications include Tetra, Cellular, PCS and many others
Monitors VSWR and power levels and provides alarm outputs
Sensitive to antenna faults that internal transmitter VSWR monitors may not detect
Local or remote operation via PC software
Ideal for multi-carrier applications
FORWARD POWER MEASUREMENT
REFLECTED POWER MEASUREMENT
VSWR ALARM CHARACTERISTICS
MODEL NUMBER DEFINITION
Frequency Range* 136* - 225 MHz
225 - 520 MHz 470 - 960 MHz 960 - 2400 MHz
Measurement Range 2.5 - 100 W, contact factory to inquire about
other power measurement ranges
Power Accuracy ±5% of reading, ±1 count
Insertion Loss 0.1 dB, 136 - 960 MHz
0.15 dB, 960 - 2400 MHz
VSWR 1.07, 136 - 960 MHz
1.1, 960 - 2400 MHz, N Connectors
1.1, 960 - 2000 MHz, 7/16 Connectors
1.2, 2000 - 2400 MHz, 7/16 Connectors
Directivity 30 dB, 136 - 960 MHz
26 dB, 960 - 2400 MHz
Alarm Set Point 1.3, 1.4, 1.5, 1.6, 1.7, 1.8 to 1
Relay Contact Type Dry, Form C, relay contacts,
common, normally open, normally closed.
Contact Rating 100 VDC @ 0.5 A
Visual Alarm Red LED will illuminate to indicate alarm
Stimulus VSWR set point exceeded, response time
proportional to overload.
Reset Local Mechanical reset switch.
Remote input (Reset if VDC is 0 to +0.8 volts).
Monitor Ports - Connectors Female N, TNC or BNC
Coupling -63 dB approx.,
Subject to changes in full-scale power
Interface Port - Connector Female DB-9, compatible with IBM PC AT serial port.
Protocol Serial RS-232, 9600 baud, no parity, 8
data bits, 1 stop bit, no handshake.
*Other frequencies & power ranges available - contact factory.
ACM ––
Freq. Range
L1 = 136* - 225 MHz L2 = 225 - 520 MHz M = 470 - 960 MHz H = 960 - 2400 MHz
AT100, AT400, AT800
7 Bird®Electronic Corporation 1-866-695-4569 www.bird-technologies.com
RF Input Connector
NM = N Male NF = N Female DM = 7/16 DIN Male DF = 7/16 DIN Female
Frequency Range 2 - 136 MHz 65 - 520 MHz 806 - 960 MHz
Frequency Resolution 20 kHz 30 kHz 30 kHz
Frequency Accuracy ±50 kHz ±100 kHz ±100 kHz
Measurement Range VSWR: 1.00 - 99.99, Match Efficiency: 00 to 100.0%, Return Loss: 0.0 to -32.0 dB
Measurement Speed (Typical) Single Frequency: 5 readings/second, Swept Frequency: 1 sweep/second
Preprogrammed Bands AMPS, NADC, GSM, PDC, CT2
Field Strength 0 to 100% (relative) Sensitivity for Full-scale deflection:
Test Port Impedance: 50 ohm, nominal. Connector (others available)
Power Requirements Batteries: 6 rechargeable AA (KR-15/51)
Operating Temperature 0°C to 50°C (32°F to 122°F)
Storage Temperature -41°C to 71°C (-40°F to 160°F)
Size (including connector) 8" H x 4 5/8" W x 1 3/4" D, (205 mm x 118mm x 42 mm)
Interface Serial (female DB-9 connector)
Weight 1 3/4 lbs. (0.8 kg)
RF Output Connector
NM = N Male
NF = N Female
DM = 7/16 DIN Male
DF = 7/16 DIN Female
Antenna & Cable Monitor
PHYSICAL AND ENVIRONMENTAL SPECIFICATIONS
Maximum Line Section Power Dependent on frequency and connector
Alarm/Power Connector 15-pin male "D" connector
Operating Temperature 0°C to 50°C
Storage Temperature -20°C to 80°C
Passive Intermodulation
Power Requirements +11 to +26 VDC or ±36 to ±72 VDC
ACCESSORIES
SUBCON-15/M-SH DB 15-pin connector
Monitor Port Connector
N = N Female T = TNC Female B = BNC Female
AT-100 AT-400 AT-800
8 v/m @ 100 MHz 0.22 v/m @ 400 MHz 3m @ 12.6 W ERP
N (F) TNC (F)
External DC: 11-16 VDC, External AC Adapter: 108-132 VAC @ 57-63 Hz, or 207-253 VAC @ 48-52 Hz
General Thruline® sensor for direct insertion in 50-ohm line
RF Connectors N or 7/16 DIN
Humidity 0 to 95% maximum (non-condensing)
Altitude Up to 3000 meters above sea level
Products Less than -130 dBc
Dimensions 4.75” (121 mm) wide (7.55” (192 mm) with con-
Weight less than 2 lbs. (0.9 kg)
Safety European Standard EN 61010-1:2001-
Model Description
7005A970 PC software, displays Antenna & Cable Monitor
ACM-RACK 19" rack shelf, mounts up to two Antenna &
ACM-RACKU 19" rack shelf with universal power supply
Input Voltage
L = + (11 to 26) VDC H = ± (36 to 72) VDC
nectors) 4.2” (107 mm) high, 1.06“(27 mm) deep
EMC European Standard EN 61326-1:1997+
Addendums A1: 1998 and A2: 2001­Electrical equipment for measurement, control and laboratory use
Safety Requirements - Electrical equipment for measurement, control and laboratory use­ECM reqirements
readings and alarms, controls alarm set points
Cable Monitors
(100 to 240 VAC, 50 - 60 Hz), mounts up to two +12 to +26 VDC Antenna & Cable Monitors
(Contact factory to inquire about other optional accessories. Specifications are subject to change.)
Options
Any combination of male or female N or 7/16 DIN input/output connector, female N or TNC coupler connector,or +11 VDC to +25 VDC or ±36 VDC to ±72 VDC power supply.
PC Software Tool 7005A970 (Optional Accessory)
FAB-READY
CAL CART
Laboratory Grade Instruments
Calibration Cart
BIRD®CALIBRATION CART
Calibration Cart
Turnkey RF Measurements at Your Fingertips
• Stainless steel mobile cart with locking wheels
• High return loss ensures minimal power measurement error contribution
• Available in international and domestic versions
• Frequency and power upgrades available (Contact factory for more details)
• Service plans available with Bird®Service Center
The SCC7 Series provides quality turnkey calibration for fab houses and equipment suppliers. The system consists of (1) 4421 Power Meter, (1) Power Sensor, (1) Oil Load, (1) Mobile Cart, and Minor Accessories.
4020 Series Power Sensor
Model Frequency Range Power Input
4021 1.8-32 MHz 300 mW to 1 kW (1.2 kW max.) 4022 25-1000 MHz 300 mW to 1 kW (1.2 kW max.) 4024 1.5-32 MHz 3 W to 10 kW (12 kW max.) 4025 100-2500 kHz 3 W to 10 kW (12 kW max.)
4027A Series Power Sensor
Model Frequency Range Power Input
4027A250K 250-400 kHz 3 W to 10 kW 4027A400K 400-550 kHz 3 W to 10 kW 4027A800K 800-950 kHz 3 W to 10 kW 4027A2M 1.5-2.5 MHz 3 W to 10 kW 4027A4M 3-5 MHz 3 W to 10 kW 4027A10M 10-15 MHz 3 W to 10 kW 4027A12M 10-15 MHz 300 mW to 1kW 4027A25M 25-30 MHz 3 W to 9 kW 4027A35M 35-45 MHz 3 W to 7.5 kW 4027A60M 45-65 MHz 3 W to 6 kW 4027A100M 95-105 MHz 3 W to 4 kW 4027A150M 150-170 MHz 3.75 W to 3.75 kW
4027F Series Filtered Power Sensor
Model Frequency Range Power Input
4027F2M 1.8-2.2 MHz 100 W to 10 kW 4027F10M 12-15 MHz 100 W to 10 kW
High Power Loads
Model Frequency Range & VSWR Power Rating
8251 DC to 1 GHz at 1.1 max. 1000 W continuous 8890-300 DC to 1 GHz at 1.1 max. 2500 W continuous
1 GHz to 2 GHz at 1.25 max.
2 GHz to 2.4 GHz at 1.3 max. 8921 DC to 1 GHz at 1.1 max. 5000 W continuous 8931-115 DC to 400 MHz at 1.15 max. 10 kW continuous w/ blower on
400 MHz to 1 GHz at 1.20 max. 2.5 kW continuous w/ blower off 8931-230 DC to 400 MHz at 1.15 max. 10 kW continuous w/ blower on
400 MHz to 1 GHz at 1.20 max. 2.5 kW continuous w/ blower off
Ultra-Stable SC13 Loads
Model Frequency Range & VSWR Power Rating
8865SC13 DC to 28 MHz at 1.1 max. 1 kW
(VSWR less than 1.05:1) 8890-300SC13 DC to 28 MHz at 1.1 max. 2.5 kW
(VSWR less than 1.05:1) 8921SC13 DC to 28 MHz at 1.1 max. 5 kW
(VSWR less than 1.05:1) 8931-115SC13 DC to 28 MHz at 1.1 max. 10 kW, 115 V
(VSWR less than 1.05:1) 8931-230SC13 DC to 28 MHz at 1.1 max. 10 kW, 230 V
(VSWR less than 1.05:1)
Fully Assembled
FAB-READY
FAB-READY
CAL CART
CAL CART
Power Levels 1, 2.5, 5, 10 kW
Meter 4421
Sensor Options 4020 Series or 4027A Series
Load Options 8251, 8890-300, 8921,
Impedance 50 ohm
Frequency Range 4020 Sensor 100 kHz - 1000 MHz
Frequency Range 4027A Sensor 250 kHz - 65 MHz
Accuracy 4020 Series ±3% (1) across power and
Accuracy 4027A Series ±1% (1) at calibration
Accuracy 4027F Series ±1% (2) across power and freqency
Casters 4 locking swivel
Connector Type *Customer Specified
Operating Position Vertical only
Power Requirements 115/230 VAC, ±10%, 50/60 Hz
Ambient Temp Range 0ºC to 45ºC
Storage Temperature -20ºC to +70ºC
Humidity 85% Max., Non condensing
Altitude Load derated above 5,000 feet
5 kW & 10 kW Size/Weight 52" L x 20" W x 42" H /
1 kW & 2.5 kW Size/Weight 42" L x 20" W x 42" H /
Material of Construction Stainless steel cart
Applicable Standards CE pending
*For connector options, please refer to our catalog or contact sales at 866.695.4569 or sales@bird-electronic.com
www.bird-technologies.com 1-866-695-4569
8931-115, 8931-230
frequency range
frequency and power levels; ±2% (1) over remainder of power range, and at other than calibration frequencies
range; ±2% (2) over remainder
(For 10 kW 0°C to +40°C)
250 lbs. Fully assembled
175 lbs. Fully assembled
Bird
®
Electronic Corporation
8
Laboratory Grade Instruments
Multi-Sensor Calibration Cart & High Power Calibration Cart
BIRD®MULTI-SENSOR CALIBRATION CART
Turnkey RF Measurements at Your Fingertips
• Stainless steel mobile cart with locking wheels
• High return loss ensures minimal power measurement error contribution
• Available in international and domestic versions
• Frequency and power upgrades available (Contact factory for more details)
• Service plans available with Bird®Service Center
The MSCC7 Series provides quality turnkey calibration for fab houses and equipment suppliers. The system consists of (1) 4421 Power Meter, (2) Power Sensors, (1) Oil Load, (1) Mobile Cart, and Minor Accessories.
4020 Series Power Sensor
Model Frequency Range Power Input
4021 1.8-30 MHz 300 mW to 1 kW (1.2 kW max.) 4024 1.5-30 MHz 3 W to 10 kW (12 kW max.) 4025 100-2500 kHz 3 W to 10 kW (12 kW max.)
4027A Series Power Sensor
Model Frequency Range Power Input
4027A250K 250-400 kHz 3 W to 10kW 4027A400K 400-550 kHz 3 W to 10kW 4027A800K 800-950 kHz 3 W to 10kW 4027A2M 1.5-2.5 MHz 3 W to 10kW 4027A4M 3-5 MHz 3 W to 10kW 4027A10M 10-15 MHz 3 W to 10kW 4027A12M 10-15 MHz 300 mW to 1kW 4027A25M 25-30 MHz 3 W to 9 kW
Power Levels 5 kW or 10 kW for either sensor
Meter 4421
Sensor Options 4020, 4027A, or 4027F Series
Load Options 8921A100, 8931A400-115, 8931A400-230
Impedance 50 ohm
Frequency Range 100 kHz - 30 MHz (depending on sensor)
Accuracy 4020 Series ±3% (1␴) Accuracy 4027A Series ±1% (1␴) Accuracy 4027F Series ±1% (2␴)
Casters 4 locking swivel
Connector Type *Customer Specified
Operating Position Vertical only
Power Requirements 115/230 VAC, ±10%, 50/60 Hz
Ambient Temp Range 0ºC to 35ºC (For 10 kW 0°C to +40°C)
Storage Temperature -20ºC to +70ºC
Humidity 85% Max., Non condensing
Altitude Load derated above 5,000 feet
5 kW & 10 kW Size/Weight 52" L x 20" W x 42" H /290 lbs. Fully assembled
Material of Construction Stainless steel cart
Applicable Standards CE
*For connector options, please refer to our catalog or contact sales at
866.695.4569 or sales@bird-electronic.com
4027F Series Filtered Power Sensor
Model Frequency Range Power Input
4027F2M 1.8-2.2 MHz 100 W to 10 kW 4027F10M 12-15 MHz 100 W to 10 kW
High Power Loads for Semiconductor
Model Frequency Range & VSWR Power Rating
8921A100 5 kW 8931A400-115 10 kW 8931A400-230 10 kW
DC to 30 MHz at 1.1 max. (less than 1.05 typical)
BIRD®HIGH POWER CALIBRATION CART
• Stainless steel mobile cart with locking wheels
• High return loss ensures minimal power measurement error contribution
• Available in international and domestic versions
• Service plans available with Bird®Service Center
The SCC8 Series provides quality turnkey calibration for fab houses and equipment suppliers. The system consists of (1) 4421 Power Meter, (1) 4028 A or B Series Power Sensor, (1) Moduload, (1) Mobile Cart, and Minor Accessories.
4028 Series Power Sensor
Model Frequency Range Power Range
4028A10M 10-15 MHz 1kW-25kW 4028A250k 250-400 kHz 1kW-20kW 4028A25M 25-30 MHz 1kW-25kW 4028A2M 1.5-2.5 MHz 1kW-25kW 4028A3M 2.5-3.5 MHz 1kW-25kW 4028A400K 400-550 kHz 1kW-20kW 4028A4M 3.5-4.5 MHz 1kW-25kW 4028B10M 10-15 MHz 1kW-25kW 4028B3M 3-4 MHz 1kW-25kW
Frequency Range 250 kHz - 30 MHz, depending on sensor (see chart)
Power Range 1 kW - 25 kW
Accuracy ±1% of reading at calibration frequency and power
levels, ±2% of reading at other power levels and frequencies within sensor range.
Connector Customer specified, appropriate for power level.
Impedance 50 ohm nominal
Sensor VSWR 1.05 max. (32.2 dB return loss)
Load VSWR 1.1 max. (26.4 dB return loss)
Coolant 100% water or 35% industrial ethylene glycol/
65% water, 9 quarts (8.5 liters), forced air cooling
Particle Generation 156 per cfm (0.5 µm), 29 per cfm (1 µm), 0 per cfm (3 µm)
Humidity 85% maximum, non-condensing
Altitude Load derated above 5,000 ft (1,524 m)
Operating Temperature +5°C to +30°C, < 25 kW, 100% water,
+5°C to +45°C, < 20 kW, 100% water, 0°C to +25°C, < 25 kW, 35% ethylene glycol/65% water, 0°C to +35°C, < 20 kW, 35% ethylene glycol/65% water
Storage Temperature +5°C to +50°C, 100% water,
- 20°C to +50°C, 35% ethylene glycol/65% water
Size 39.5" L x 21.5" W x 39.5" H
(1003.3mm x 546.1mm x 876.3mm)
Weight 240 lbs (109 kg)
Material of Construction Stainless steel cart
Applicable Standards CE pending
9 Bird®Electronic Corporation 1-866-695-4569 www.bird-technologies.com
Laboratory Grade Instruments
4020 Series & 4021 Power Meter
Semiconductor
4020 SERIES — Power Sensor
4021 4022 4024 4025
Power Input 300 mW to 1 kW 300 mW to 1 kW 3 W to 10 kW 3 W to 10 kW
(1.2 kW max.) (1.2 kW max.) (12 kW max.) (12 kW max.)
Frequency Range 1.8-32 MHz 25-1000 MHz 1.5-32 MHz 100-2500 kHz
Insertion Loss <0.05 dB <0.05 dB <0.05 dB <0.05 dB
Accuracy ±3% of reading from rated max. to rated min.
BIRD®MODEL 4421
Precision Power Meter for Semiconductor Processing Applications
±1% Accuracy - Accomplished through the use of sensors with an
automatic frequency compensation scheme, where the error contribu­tions due to directional coupler frequency response characteristics are eliminated.
Wide Dynamic Range - The instrument will meet the full accuracy
specification over a 35 dB dynamic range.
Excellent Measurement Repeatability - Typically <0.1%
Digital Display - Along with automatic VSWR calculation
Computer Interface - RS-232 and IEEE-488 standard
The Bird®Model 4421 is a precision RF power meter that, while originally intended for general purpose laboratory applications where high accuracy is required, has found wide acceptance in semiconductor processing applications. The product is configured as a system, consisting of the Model 4421 digital display and a precision power sensor selected for the application based upon maximum power and operating frequency.
Model 4421
MODEL 4421 MULTIFUNCTION POWER METER
Power Range 100 mW to 25 kW FS
Frequency Range 100 kHz - 1 GHz
VSWR Range 1.0 - 199.9
Functions Forward and reflected power in W or dBm, VSWR,
return loss in dB and min./max. values
Overrange Audible warning when RF power input exceeds
120% of sensor's maximum power range
Indication Display 3 1/2 digit-liquid crystal display with indicator
for mode, measurement units, battery condition, programming status, and trend arrows. Switchable backlight.
Operating Power 115/230 VAC, 50/60 Hz or 8 nickel metal hydride
1.2 V cells (NEDA type 10014)
Nominal Size 12 9/32" L x 12 5/32" W x 4 1/4" H
(312 mm x 309 mm x 108 mm) with handle extended 15 7/16" L (392 mm)
Weight 11 lbs. (5 kg.)
Interconnects 1 meter latch-n-lock coiled cable
Interfaces IEEE-488 and RS-232 standard
Dimensions 4 1/2" x 6 1/2" (114 x 165 mm)
Required Product RF Power Sensor
Accessories Case 4300A215 (page 43)
19” Panel Mount Kit 4421-250 Latch & Lock Case 4421-038
MODEL 4421A530 CALIBRATION KIT
Calibration Key
Weight 3 oz. (85 g.)
Cable Length Approx. 3 ft. (1 m)
Required Products 4421 power meter, 4020 Series power sensor,
RF power source, RF low-pass filter, RF terminating power standard (Bird®Model 6091 calorimeter recommended) and IBM compatible computer fitted with a GPIB card-specify standard.
Performance
Measurement Cycle 1 Year
Limitation Not compatible with 4027 Series Sensor
www.bird-technologies.com 1-866-695-4569
®
Electronic Corporation
Bird
10
Laboratory Grade Instruments
±1%1%
ACCURACYACCURACY
Model 4027A Power Sensor
BIRD®Model 4027A
Precision Power Sensors for Precision Process Applications
Achieves tighter, more consistent RF power measurements for improved yield.
• ±1% accuracy at specified calibration frequencies and power levels.
• Direct, plug-in operation with the industry standard Bird® Model 4421 RF Power Meter.
• Multiple sensors provide for measurement of 0.3 W - 10 kW over a 250 kHz - 170 MHz frequency range.
Bird's®new 4027A Series Power Sensors represent a family of sensors for use in semiconductor processing and other precision process applications. Intended for use with the industry standard Bird®Precision Laboratory Power Meter Model 4421, these products provide a threefold improvement in long-term unit-to-unit accuracy.
POWER MEASUREMENT
CONNECTORS Customer specified
POWER REQUIREMENTS
4027A SERIES — Power Sensor
Power Range 300 mW-1 kW 3 W-10 kW 3 W-9 kW 3 W-7.5 kW 3 W-6 kW 3 W-4 kW 3.75 W-3.75 kW 100 W-10 kW
Frequency 10-15 MHz 250-400 kHz 400-550 kHz 800-950 kHz 1.5-2.5 MHz 3-5 MHz 10-15 MHz 25-30 MHz 35-45 MHz 45-65 MHz 95-105 MHz 150-170 MHz 1.8-2.2 MHz 12-15 MHz
Accuracy
VSWR Range 1.0 to 2.0 (40.0 to 9.5 dB return loss)
Directivity 28 dB
Insertion Loss < 0.05 dB
Calibration
Power Level
Uniformity 2% maximum unit to unit, at calibration frequency and power levels
Speed 2 readings per second.
Maximum
Power
Connectors Must be specified at time of order
Sensor Interface Latch-n-Lock
External DC 12 VDC, supplied from Multifunction Power Meter Dimensions 5 7/32" L x 2 1/2" W x 3 1/4" H 5.128”L x 2.506”W x 3.280”H
Weight 1 lb. 11 oz. (0.76 kg)
Operating
Temperature
Storage
Temperature
Calibration Cycle 6 month. Performance before and performance after data to be supplied for units.
Accuracy ±1% (1) at calibration frequencies and power levels;
Calibration
Power Level 1000 W units: 700 watts. 10 kW units: 1700 watts.
Uniformity 2% maximum unit to unit, at calibration frequency
Maximum Power 10 kW units - 12 kW max.
External DC 12 VDC, supplied from Bird 4421 Power Meter
4027A12M 4027A250K 4027A400K 4027A800K 4027A2M 4027A4M 4027A10M 4027A25M 4027A35M 4027A60M 4027A100M 4027A150M 4027F2M 4027F10M
±2% at other frequencies and power levels. Add 2% to uncertainty outside 25 ± 10°C
and power levels.
Speed 2 readings per second.
1 kW units - 1.2 kW max.
±1% at calibration frequencies and power levels; (59°F to 95°F) operating temp.
±2% at other frequencies & power levels within sensor range. ±3%within 0°C-15°C or within
1000 W units: 700 watts. 10 kW units: 1700 watts.
15°C to 35°C (59°F to 95°F)
-40°C to 80°C (-40°F to 176°F)
PHYSICAL SPECIFICATIONS
Dimensions 5.2" L x 2.5" W x 3.25" H
Weight 13 oz. (0.8 kg)
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature 15°C to 35°C (59°F to 95°F)
Storage Temperature -40°C to 80°C (-40°F to 176°F)
Humidity 95% maximum (non-condensing)
Altitude Up to 10,000 feet (3,048 m)
General EMC Designed to carry CE mark (with immunity
exception noted below)
Emissions EN-55011, 1991, Class B
Immunity EN-50082-1, 1995
Safety EN-61010, 1993 in accordance with Council
Directives 73/23/EEC and 93/68/EEC
Calibration Cycle 6 month. Performance before and performance after
data to be supplied for units.
±1%within 15°C to 35°C
35°C-50°C operating temp.
1.2 kW (on 1 kW units)
11 Bird®Electronic Corporation 1-866-695-4569 www.bird-technologies.com
Laboratory Grade Instruments
Model 4028 Power Sensor
BIRD®Model 4028
High Power, Precision Power Sensors for Precision Process Applications
Achieves tighter, more consistent RF power measurements for improved yields.
• ± 2% at calibration frequencies and power levels. ± 4% at other frequencies and power levels. Add 2% to
uncertainty outside 25 ± 10 °C.
• Direct, plug-in operation with the industry standard Bird® Model 4421 RF Power Meter.
• Multiple sensors provide for measurement over a 250 kHz to 30 MHz frequency range
• Capable of power measurements up to 50kW.
With the expanding surface areas in the LCD and Solar panel industry, higher power levels are necessary for the industries processes. The Bird 4028 series sensor is designed to meet the growing RF power measurement challenge with accuracy, repeatability and versatility to meet current and future applications. Bird continues to innovate useful sensor technology to meet these fast paced markets.
POWER MEASUREMENT
CONNECTORS
4028 SERIES — Power Sensor
Power Range 1 kW - 20 kW 1 kW - 25 kW 500 W-50 kW
Frequency 250 - 400 kHz 400 - 550 kHz 1.5 - 2.5 MHz 2.5 - 3.5 MHz 3.5 - 4.5 MHz 10 - 15 MHz 25 - 30 MHz 2.5 - 4 MHz 10 - 15 MHz 10 - 15 MHz
Accuracy
VSWR Range 1.0 to 2.0 (40.0 to 9.5 dB return loss)
Directivity 28 dB
Insertion Loss < 0.05 dB
Calibration
Power Level
Uniformity 2% maximum unit to unit, at calibration frequency and power levels
Speed 2 readings per second.
Connectors Must be specified at time of order 1-5/8 EIA Flanged 3-1/8 EIA Flanged
Sensor Interface Latch-n-Lock
External DC 12 VDC, supplied from Power Meter Dimensions 4.7" L x 3.2" W x 4.0" H 6.8" L x 3.5" W x 4.8" H 8.0" L x 5.2" W x 6.4" H
Weight 1.7 lbs. 3.3 lbs. 5.2 lbs. 7.3 lbs.
Operating
Temperature
Storage
Temperature
Calibration Cycle 6 months. Performance before and performance after data to be supplied for units.
Accuracy ±2% (1) at calibration frequencies and power levels;
Calibration
Power Level 250 and 400kHz units: 1.7kW
Uniformity 2% maximum unit to unit, at calibration frequency
Maximum Power 4028AxxK: 20kW
4028A Series Customer Specified 4028B Series 1-5/8 EIA Flanged 4028C Series 3-1/8 EIA Flanged
4028A250K 4028400K 4028A2M 4028A3M 4028A4M 4028A10M 4028A25M 4028B3M 4028B10M 4028C10M
±4% at other frequencies and power levels. Add 2% to uncertainty outside 25 ± 10°C
all other units: 3.5kW
and power levels.
Speed 2 readings per second.
4028AxxM: 25kW 4028B: 25kW 4028C: 50kW
±2% (1) at calibration frequencies and power levels; ±4% at other frequencies and power levels.
Add 2% to uncertainty outside 25 ± 10°C
250 and 400kHz units: 1.7kW; all other units: 3.5kW
0°C to 50°C (32°F to 122°F)
-20°C to 70°C (-4°F to 158°F)
POWER REQUIREMENTS
External DC 12 VDC, supplied from Bird 4421 Power Meter
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature 0°C to 50°C (32°F to 122°F)
(derate accuracy outside 25 ± 10°C)
Storage Temperature -20°C to 70°C (-4°F to 158°F)
Humidity 95% non-condensing
Altitude 10,000 feet (3,000 m)
General EMC Designed to carry CE mark (with immunity
exception noted below)
Emissions EN-55011, 1991, Class B
Immunity EN-50082-1, 1995
Safety EN-61010, 1993 in accordance with Council
Directives 73/23/EEC and 93/68/EEC
Calibration Cycle 6 months
www.bird-technologies.com 1-866-695-4569
®
Electronic Corporation
Bird
12
Power Measurement
Model 5012 Wideband Sensor and vDPM Software
Wideband
BIRD®Model 5012
Bird's®Site Management Solutions for Power Measurement
Power Sensor
• Easy to use & competitive price
• Wide frequency range (350 MHz - 4000 MHz)
• Direct connection to PC, Digital Power Meter or Site Analyzer®- NO BLACK BOX !!!!
• 30 dB Directivity-Up to 3 GHz; 28 dB up to 4 GHz
• Directional-Forward and Reflected Power
• No elements required!
When combined with a Digital Power Meter, Site Analyzer®Family of line and antenna analysis products, or a Personal Computer, the Wideband Power Sensor becomes an integral part of a very robust and sophisticated power measurement solution.
Sensor Characteristics - General
Power Measurement Range 0.15 W - 150 W average, 400 W peak
Reflection Measurement Characteristics
Interface Specifications:
Power Requirements
Power Measurement Characteristics
Power Measurement 2.0 W - 150 W 10 W - 150 W 4.0 W - 150 W 4.0 W - 400 W 0.1 - 100%
Peak/Average Ratio 12 dB max.
Repetition Rate 15 Hz min.
Threshold Level Range 4 W to 400 W
Level Set Accuracy ±5% of level ±0.5 W
Measurement
Frequency Range 350 MHz - 4 GHz
Impedance 50 ohm (nominal)
Insertion Loss <0.05 dB up to 1 GHz,
Insertion VSWR <1.05 up to 2.5 GHz,
Input Connector N Female
Output Connector N Female
Directivity 30 dB up to 3.0 GHz, 28 dB up to 4.0 GHz
Measurement Range Return Loss, 0.0 to 23 dB
Minimum Forward Power 0.5 W
DC input connector 7-18 VDC at less than 0.1A
Range
Burst Width
Duty Cycle
Uncertainty
Weight 1.2 lb. max.
DPM Interface EIA-232, 9600 Baud, no parity,
PC Interface(1) EIA-232, 9600 Baud, no parity,
PC Interface(2) USB 1.1 compliant interface
USB port Less than one low-power USB load
(+15°C to +35°C) Duty Cycle Entered, (+15°C to +35°C) power uncertainty (+15°C to +35°C)
<0.1 dB from 1 GHz to 4.0 GHz
<1.10 from 2.5 to 4.0 GHz
VSWR, 1.15 to 99.9 Rho, 0.07 to 1.0
8 data bits, 1 stop bit
8 data bits, 1 stop bit
Average Burst Average Crest Factor Peak Envelope Complementary Cumulative
Power Power Peak-to-Average Power Distribution Function (CCDF)
1 us to 50 ms Duty Cycle Measured
D=Burst Width/Period, 0.001 to 1
±4% of reading, ± 6% of reading ± 0.05/D W, Sum of peak and average ±7% of reading ± 0.2 W from 200 µs ±0.2%
±7% of reading, ± 9% of reading ± 0.05/D W, ±10% of reading ± 0.4 W from 1 µs
(-10°C to +50°C) Duty Cycle Entered, (-10°C to +50°C) (+15°C to +35°C)
Data Logging (requires VPM Kit)
Physical and Environmental Specifications
Model 5012 Accessories
Comtatible Devices
average average
––
––
Data Capture Time, forward average or peak power,
Sampling Interval 1 to 1000 seconds
General Thruline®power measurement
Operating Temperature -10°C to +50°C (+14°F to +122°F)
Storage Temperature -40°C to +80°C (-40°F to +176°F)
Mechanical Shock IAW MIL-PRF-28800F class 3
Vibration IAW MIL-PRF-28800F class 3 Humidity 95% maximum (non-condensing)
Altitude 15,000 ft operating
Weight 1.2 lb. maximum
VPM-KIT-NA Virtual Power Meter Kit 115V
VPM-KIT-E Virtual Power Meter Kit 230V
PTA-MNMN Precision Test Adapter Male N to Male N
PTA-MNME Male N to Male 7/16 (DIN)
PTA-MNFE Male N to Female 7/16 (DIN)
5000-EX Digital Power Meter SA-6000EX Site Analyzer SA-2500EX Site Analyzer
SA-1700EXP Site Analyzer
SH-36S SignalHawk
add ±3% of reading if temperature
-10°C to +15°C or +35°C to +50°C add ±1.5% of reading + 0.15 W for
period > 0.1 seconds
add ±0.1 W for D from 0.001 to 0.1
add ±5% or reading for burst widths
add ±10% of reading for burst widths
reflected power
Size 3.78”(4.74) W X 4.56” H X 1.28” D
without connector
4.74” W X 4.56” H X 1.28” D including connectors
®
,
Antenna, & Cable Tester
®
,
Antenna, & Cable Tester
®
,
Antenna, & Cable Tester
®
,
Spectrum Analyzer
less than 1 µs
less than 0.5 µs
13 Bird®Electronic Corporation 1-866-695-4569 www.bird-technologies.com
BIRD®Model 5011 & 5011-EF Terminating Power Sensor
Terminating
Designed to make Terminating Power Measurements with the full flexibility of a portable precision instrument (Requires Bird®MODEL 5000EX, SA-6000EX, SA-2500EX or SA-1700EXP)
Power Sensor
Significant cost and time savings, easy to use and field ready
No calibration and no elements required
Both digital as well as analog modulations including
(CDMA, GSM, TDMA, 8-VSB and COFDM) Broadcast Transmitter Power with accuracy of ±5% of readings
Measure power directly or via coupled test port
Power Measurement
Model 5011 Terminating Sensor
Model 5011 Terminating Power Sensor
SPECIFICATIONS
Sensor Type Terminating Power Sensor. Terminated
Frequency Range 5011 - 40 MHz - 4 GHz
Power Range -20.000 to +10.000 dBm (10.000 µW to 10.000 mW)
Peak/Average Ratio 12 dB max.
* When operating below 100 MHz and above 40°C, add 1%. NOTE: The Bird (SA-6000EX, SA-2500EX, or SA-1700EXP) is required.
Accuracy ±5% of reading ±1mW RSS (excluding mismatch
Warm Up Time 5 Minutes
Input Impedance 50 ohm (nominal)
Input VSWR 5011 -Typical 1.03 (36.6 dB return loss); maximum 1.20
Input Connector Precision N Male
Output Connector Male DB-9 to interface to Digital Power Meter or
Power Supply From host instrument via cable connection
Operating Temp. -10°C to 50°C (14°F to 122°F)
Storage Temp. -40°C to 80°C (40°F to 176°F)
Humidity 95% maximum (non-condensing)
Altitude 15,000 ft operating
Weight 3/4 lb. max.
®
Model 5000-EX or the Bird®Site Analyzer®Series
average power measurement.
5011EF - 40 MHz to 12 GHz
uncertainty)*
(20.8 dB return loss) 5011-EF -Typical 1.05 (32.3 dB return loss); maximum
1.25 (19.1 dB return loss)
Site Analyzer
Size 6" long (including connectors); 1.5" diameter
®
ACCESSORIES
Model Description
8353A040-50** Attenuator, 50 W, 40 dB, N (F) to
8353A030-10 Attenuator, 10 W, 30 dB, N (F) to
5011-CALDATA Calibration Data for TPS 5011 Attenuators
4240-500-1 Adapter, N (F) to N (F) 4240-500-3 Adapter, right angle, N (F) to N (M) 4240-500-4 Adapter, N (F) to SMA (F) 4240-500-5 Adapter, N (F) to SMA (M)
PA-FNME Adapter, N (F) to 7/16 DIN (M)
PA-FNFE Adapter, N (F) to 7/16 DIN (F)
TC-MNFN-1.5-G Test cable, 1.5 m., N (M)/N (F) conn.
TC-MNFN-1.5 Test cable, armored, PS, 1.5 m.,
TC-MNFN-3.0 Test cable, armored, PS, 3.0 m.,
N (F) to N (M)
5011A035-1 DC Block, N (F) to N (M)
**Optional 40 dB attenuator provides 100 mW to 50 W capability, other ranges also available.
COMPATIBLE DEVICES
5000-EX Digital Power Meter SA-6000EX Site Analyzer SA-2500EX Site Analyzer
SA-1700EXP Site Analyzer
SH-36S SignalHawk
N (M) 100 mW to 50 W with TPS 5011
N (M) 10 mW to 10 W with TPS 5011
and Accessories.
N (F) to N (M)
®
,
Antenna, & Cable Tester
®
,
Antenna, & Cable Tester
®
,
Antenna, & Cable Tester
®
,
Spectrum Analyzer
www.bird-technologies.com 1-866-695-4569
®
Electronic Corporation
Bird
14
Power Measurement
Wideband Coupler
Wideband
BIRD®Wideband Coupler
Cost effective
Portable
Easy-to-use
SPECIFICATIONS
Frequency Range 45 MHz - 230 MHz (VHF Models)
Maximum Power Transmission line and frequency dependent
Nominal Coupling Transmission line dependent (See Table 1)
Directivity 28 dB Min.
Coupler Output
Connector Type “N” Female
Coupler Output
Main Line VSWR 1.1 Max.
Coupling Uncertainty
(after correction) ±0.05 dB
Operating Temp. -10°C to 40°C
Storage Temp. -20°C to 85°C
Weight Transmission Line Dependent (See Table 2)
Dimensions Transmission Line Dependent (See Table 2)
TABLE 1
Line Size VHF UHF
1-5/8" 62 dB ±2 dB 59 dB ±2 dB 3-1/8" 69 dB ±2 dB 64 dB ±2 dB 4-1/16" 70 dB ±2 dB 67 dB ±2 dB 6-1/8" 75 dB ±2 dB 75 dB ±2 dB
450 MHz - 890 MHz (UHF Models) 450 MHz - 800 MHz (6” UHF Models)
VSWR 1.2 Max.
Coupler
TABLE 2
Model Number Line Size Frquency Range Length (in.) Weight (lbs.)
WBC1-45 1-5/8 Flanged VHF 6.75 3.65 WBC1U-45 1-5/8 Unflanged VHF 6.38 1.8 WBC1-400 1-5/8 Flanged UHF 6.75 3.65 WBC1U-400 1-5/8 Unflanged UHF 6.38 1.8 WBC3-45 3-1/8 Flanged VHF 7.03 6 WBC3U-45 3-1/8 Unflanged (Recessed) VHF 6.5 2.75 WBC3UF-45 3-1/8 Unflanged (Flush) VHF 6.5 2.75 WBC3-400 3-1/8 Flanged UHF 7.03 6 WBC3U-400 3-1/8 Unflanged (Recessed) UHF 6.5 2.75 WBC3UF-400 3-1/8 Unflanged (Flush) UHF 6.5 2.75 WBC4-45 4-1/16 Flanged (Dielectric) VHF 8.38 8.88 WBC4M-45 4-1/16 Flanged (MYAT) VHF 8.38 8.88 WBC4U-45 4-1/16 Unflanged (Dielectric) VHF 7.5 2.88 WBC4-400 4-1/16 Flanged (Dielectric) UHF 8.38 8.88 WBC4M-400 4-1/16 Flanged (MYAT) UHF 8.38 8.88 WBC4U-400 4-1/16 Unflanged (Dielectric) UHF 7.5 2.88 WBC6-45 6-1/8 Flanged VHF 10.22 13.2 WBC6U-45 6-1/8 Unflanged VHF 9.63 7.2 WBC6-400 6-1/8 Flanged UHF 10.22 13.2 WBC6U-400 6-1/8 Unflanged UHF 9.63 7.2
15 Bird®Electronic Corporation 1-866-695-4569 www.bird-technologies.com
Power Measurement
Model 5010B Thruline® Sensor
®
BIRD®Model 5010B Dual-Socket Thruline® Directional Power Sensor
Thruline
Digital
Bird’s®Most Sophisticated Thruline®Sensor System is the Heart of the MODEL 5000-EX (Requires Bird®MODEL 5000-EX, SA-6000EX, SA-2500EX or SA-1700EXP)
Power Sensor
Dual-element THRULINE®design for simultaneous forward and
reflected power readings. Measures true average power.
Peak power measurement (using 43 elements**)
±
5% of reading accuracy rivals thermal wattmeters in actual field use.
Small, easily-remoted sensor facilitates convenient hand-held operation.
The
Model 5010B Dual-Socket THRULINE®Power Sensor
is a precision 50-ohm 7/8-inch “Smart” Line Section which accepts Bird®digital-ready Plug-in DPM Elements. The true average and peak power readings for digital as well as traditional analog RF systems.
The
Model 5010B Power Sensor
is compatible with many existing Bird®accessories for 7/8" line, including signal samplers, and over 20 types of QC connectors. QC Connectors can be changed rapidly and conveniently in the field by removing four screws from the connector.
Model 5010B Sensor
provides
Model 5010B Thruline®Directional Power Sensor
*DPM Element Guide
Frequency Forward Reflected Forward Reflected
Range Power Range Power Range Element Element
2 - 30 MHz
25 - 60 MHz
50 - 125 MHz 12.5 W to 500 W 1.25 W to 50 W DPM-500B DPM-50B
100 - 250 MHz 12.5 W to 500 W 1.25 W to 50 W DPM-500C DPM-50C
200 - 500 MHz 1.25 W to 50 W 125 mW to 5 W DPM-50D DPM-5D
400 - 960 MHz 2.5 W to 100 W 250 mW to 10 W DPM-100E DPM-10E
950 - 1260 MHz
1100 - 1800 MHz
1700 - 1990 MHz
1900 - 2200 MHz
2200 - 2300 MHz
2300 - 2500 MHz 125 mW to 5 W 12.5 mW to 500 mW DPM-5N DPM-.5N 2500 - 2700 MHz 125 mW to 5 W 12.5 mW to 500 mW DPM-5R DPM-.5R
1.25 W to 50 W 125 mW to 5 W DPM-50H DPM-5H
12.5 W to 500 W 1.25 W to 50 W DPM-500H DPM-50H
1.25 W to 50 W 125 mW to 5 W DPM-50A DPM-5A
12.5 W to 500 W 1.25 W to 50 W DPM-500A DPM-50A
1.25 W to 50 W 125 mW to 5 W DPM-50B DPM-5B
25 W to 1 kW 2.5 W to 100 W DPM-1000B DPM-100B
1.25 W to 50 W 125 mW to 5 W DPM-50C DPM-5C
62.5 W to 2.5 kW 6.25 W to 250 W DPM-2500C DPM-250C 125 mW to 5 W 12.5 mW to 500 mW DPM-5D DPM-.5D
12.5 W to 500 W 1.25 W to 50 W DPM-500D DPM-50D 125 mW to 5 W 12.5 mW to 500 mW DPM-5E DPM-.5E
1.25 W to 50 W 125 mW to 5 W DPM-50E DPM-5E
12.5 W to 500 W 1.25 W to 50 W DPM-500E DPM-50E
25 W to 1 kW 2.5 W to 100 W DPM-1000E DPM-100E
125 mW to 5 W 12.5 mW to 500 mW DPM-5J DPM-.5J
1.25 W to 50 W 125 mW to 5 W DPM-50J DPM-5J 125 mW to 5 W 12.5 mW to 500 mW DPM-5K DPM-.5K
1.25 W to 50 W 125 mW to 5 W DPM-50K DPM-5K 125 mW to 5 W 12.5 mW to 500 mW DPM-5L1 DPM-.5L1
1.25 W to 50 W 125 mW to 5 W DPM-50L1 DPM-5L1
12.5 W to 500 W 1.25 W to 50 W DPM-500L1 DPM-50L1
1.25 W to 50 W 125 mW to 5 W DPM-50L2 DPM-5L2 125 mW to 5 W 12.5 mW to 500 mW DPM-5L2 DPM-.5L2
625 mW to 25 W 62.5 mW to 2.5 W DPM-25M DPM-2.5M
125 mW to 5 W 12.5 mW to 500 mW DPM-5M DPM-.5M
SPECIFICATIONS
Sensor Type Bird
Frequency Range Element limited. Please view element
Power Range Element limited. Please view element guide
Pulse width >100 MHz 800 ns min.
Parameters 26-99 MHz 1.5 µs min.
Pulse Rep. Rate Peak 15 pps min.
Pulse Duty Factor 1 x 10-4min.
Accuracy TRUE AVERAGE POWER, ±5% of reading (15°C to
Dynamic Range 40:1 (E.G. 50 W element
Peak/Average 10 dB maximum with DPM elements
Power Ratio
Settling Time < 2 seconds
Connectors QC Type. Female N normally supplied.
Insertion VSWR 1.05:1 from 0.45 to 1000 MHz
Dimensions 1.875" H x 1.875" W x 3.5" D
Weight 1.12 lbs. (0.51 kg)
Operating Temp. -10°C to +50°C
Storage Temp. -40°C to +75°C
Humidity 95% max. (non-condensing)
COMPATIBLE DEVICES
5000-EX Digital Power Meter SA-6000EX Site Analyzer SA-2500EX Site Analyzer
SA-1700EXP Site Analyzer
SH-36S SignalHawk
®
THRULINE®directional
dual-element line section
guide for current listing.
for current listing. 1 W to 1000 W*
2-25 MHz 15 µs min.
35°C), ±7% of reading (-10°C to 50°C) PEAK POWER, ±8% of full scale
measure 1.25 W to 50 W).
(with N connectors)
(47.7 mm x 47.7 mm x 88.9 mm) excluding connectors
®
,
Antenna, & Cable Tester
®
,
Antenna, & Cable Tester
®
,
Antenna, & Cable Tester
®
,
Spectrum Analyzer
* Note: 5010B supercedes 5010 **Note: For average power readings, use the elements listed above in the DPM Element Guide.
For peak power readings, use elements from Tables 1-6 pages 42 & 43.
www.bird-technologies.com 1-866-695-4569
®
Electronic Corporation
Bird
16
Loading...
+ 39 hidden pages