Bio-Rad Trans-Blot SD Semi-Dry Transfer Cell User Manual

Trans-Blot®SD
DNA/RNA
Blotting Kit
Instruction
Manual
Catalog Number
For use with the Trans-Blot SD
sem-dry electrophoretic transfer
cell (catalog numbers 170-3940,
170-3948, 170-3949)
For Technical Service Call Your Local Bio-Rad Office or in the U.S. Call 1-800-4BIORAD (1-800-424-6723)
Table of Contents
Page
Section 1 Introduction .................................................................................................. 1
1.1 Specifications..............................................................................................................1
Section 2 Preparation for DNA Blotting .................................................................... 2
Section 3 Preparation for RNA Blotting .................................................................... 2
Section 4 General Assembly of Unit for Transfer ..................................................... 3
Section 5 Troubleshooting Guide ................................................................................ 4
A. Poor Electrophoretic Transfer ............................................................................... 4
B. Poor Detection Sensitivity ..................................................................................... 5
C. High Background................................................................................................... 5
Section 6 Appendix ....................................................................................................... 6
Section 7 Equipment and Accessories ........................................................................ 7
Section 8 References ..................................................................................................... 8
Note
To insure best results from the Trans-Blot SD DNA/RNA Blotting Kit, become fully acquainted with its instructions before using the kit. It is also recommended that you follow the protocol as closely as possible in order to achieve optimum results.
Bio-Rad recommends that the kit component (gel support frame) be cleaned with a mild, labora­tory cleaner (such as Bio-Rad Cleaning Concentrate, catalog number 161-0722) and rinsed thor­oughly with distilled water, before use.
Warranty
Bio-Rad Laboratories warrants the gel support frame against defects in materials and workman­ship for 1 year. If any defects should occur with the frame during the warranty period, Bio-Rad Laboratories will replace the part free of charge. The following defects, however, are specifically excluded:
1. Defects caused by improper operation.
2. Damage caused by accident or misuse.
3. Damage caused by disaster.
4. Corrosion due to use of improper solvent or sample.
For an inquiry, contact Bio-Rad Laboratories in the U.S at 1-800-4-BIORAD, outside the U.S. contact your local Bio-Rad office.
Catalog No.
Date of Delivery
Invoice No.
Purchase Order No.
Section 1 Introduction
The standard capillary transfer of DNA/RNA from agarose gels to blotting membranes is
usually an overnight procedure.
1-3
The Trans-Blot SD DNA/RNA blotting kit, used with the Trans-Blot SD semi-dry transfer cell, allows blotting of DNA and RNA from agarose gels to nylon membrane in only minutes, without any gel pretreatments. The Trans-Blot SD semi-dry electrophoretic transfer cell generates a high field strength (V/cm2) which facilitates rapid transfers. The blotting kit produces highly efficient transfers by eliminating crushing of agarose gels. PCR* fragments, plasmid, and vector DNA ranging in size from several hundred bases to 15 kilobases can be transferred in as little as 10 minutes. Set-up time is reduced to just minutes because hydrolyzation of DNA fragments is not required prior to transfer. The blot­ting kit can also transfer RNA to 3.5 kb in 30-35 minutes, although transfer of 28s RNA is equally efficient as determined by EtBr staining.
4
Read the Trans-Blot SD transfer cell instruction manual thoroughly before per­forming semi-dry electrophoretic DNA or RNA transfers.
1.1 Specifications
Construction:
Gel support frame Molded polycarbonate Overall frame size: 16 x 21 cm Maximum gel size: 15 x 20 cm
Cleaning: Use mild soap and warm water to clean the gel support frame.
For cleaning the Trans-Blot SD semi-dry electrophoretic transfer cell, refer to the semi-dry cell instruction manual.
Chemical compatibility: The gel support frame is not compatible with TCA (trichloroacetic
acid), chlorinated hydrocarbons (e.g. chloroform), aromatic hydrocarbons (e.g. toluene, benzene), or acetone. Use of such organic solvents voids all warranties.
NOTE: The kit is intended for gels with dimensions of up to 15 x 20 cm. To blot a unique size gel, adjustments must be made in transfer membrane and blot paper dimensions. For questions regarding the proper assembly and operation of the Trans-Blot SD semi-dry electrophoretic transfer cell, refer to the instruction manual provided with the instrument.