PLEASE READ AND SAVE THESE
IMPORTANT INSTRUCTIONS.
With proper care and use, this air purifi er will give
you fresh, clean air for many years.
NOTE: Before reading these instructions, please
view the corresponding illustrations.
DESCRIPTIONS (See Fig.1 & 2)
A. Handle Loop
B. Control Panel
C. Front Housing
D. Rear Housing
E. Grill
F. Power Button
G. Power Light
H. Speed Control
I. Filter Reset Button
J. Timer Button
K. Ioniser Control
L. Filter Service Indicator Light
SAFETY PRECAUTION
Carefully read and retain all instructions before
using the air purifi er.
• To avoid fi re or shock hazard, check that the
voltage on the product corresponds to your
electricity supply and plug directly into an
electrical outlet.
• To avoid fi re hazard, never put the cord under
rugs, or near any heat source.
• Carefully discard any plastic wrapping that
was used for the packaging.
• Do not use the air purifi er outside.
• Do not place the unit near any heat source or
in direct sunlight.
• Always unplug the air purifi er before
removing the grill, changing the fi lters,
cleaning the air purifi er or whenever it is not
in use.
• Do not use in or around water or any other
liquids. Do not attempt to wash the unit under
running water.
• Use appliance only for intended household
use as described in this manual.
• Ensure that all air openings are not restricted
or covered in any way.
• Do not place anything on top of the unit.
• Never insert any object into any openings.
• Do not use the air purifi er if any part is
missing or damaged in any way.
• Do not attempt to repair or adjust any
mechanical functions of this unit. If the unit
becomes damaged return to the place of
purchase or phone the helpline number on
the back of this leafl et.
• If the supply cord or plug is damaged, it
must be replaced by the manufacturer or its
service agent or a similarly qualifi ed person
in order to avoid hazard.
• The air purifi er contains no user serviceable
parts and should the product suffer damage
or breakdown it must be returned to the
manufacturer or its service agent.
• Should the air purifi er stop working, fi rst
check the fuse in the plug (UK only) or
fuse/circuit breaker at the distribution
board is operating, before contacting the
manufacturer or service agent.
• This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities,
or lack of experience and knowledge,
unless they have been given supervision or
instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that
they do not play with the appliance.
• CAUTION: To Prevent Risk of Electric
Shock, Remove Cord Plug from Outlet
Before Opening Appliance. To Prevent
Risk of Fire, Inspect and Clean Equipment
Regularly as Noted in This Manual.
HOW THE AIR PURIFIER WORKS
Dirty, dust laden air is drawn through the rear
of the air purifi er and through the multi-stage
fi ltration system.
1. The washable foam pre-fi lter captures larger
particles and extends the HEPA-type fi lter’s
replacement cycle.
2. The HEPA-type fi lter entraps 99% of all
smaller visible and non-visible particles down
to 2 microns in size.
3. The independent ioniser naturally improves
performance and freshens the air.
PRODUCT FEATURES
High, Medium and Low settings
For optimum air fi ltration, operate your air purifi er
continuously on the Medium (2) setting. Its
rugged motor has been designed to give many
years of use. For quieter operation (such as in a
bedroom), select the Low (1) setting. When high
levels of air pollution are present, select the High
(3) setting.
Filter Service Indicator
The fi lter service indicator light (L) eliminates
guesswork by letting you know when it is time to
replace the HEPA-type fi lter. The light is green
when the fi lter is fully clean, yellow when the fi lter
is nearing replacement, and red when the fi lter
needs to be replaced. After the fi lter is replaced,
reset by pressing down 3 seconds on the fi lter
reset button (I). Note that the green and red lights
will blink three times when the unit is turned on,
and the green light will blink three times after
being reset.
Timer
The timer allows you to run the air purifi er
at your convenience for 2, 4 or 8 hours, and
automatically turns the power off when time is up.
Ioniser
This appliance has an independent ioniser
feature which, when turned on, releases negative
ions into outgoing fi ltered air to help the air
purifi cation process.
What Are Ions?
Ions are tiny particles that carry a positive or
negative charge. They exist naturally around us:
in the air, water, and ground. Both positive and
negative ions are colourless, odourless, and
completely harmless.
How Does The Ioniser Work?
Negative ions help air purifi cation by attaching
themselves to very small airborne particles in the
room. These particles take on a negative charge
and may join with positively charged particles
such as dust, pollen, smoke, and pet dander to
form larger particles. The larger particles are then
more easily captured by the fi lter system.
Important Notes:
Your ioniser may produce an occasional popping
or cracking sound. This is normal and occurs
when a small buildup of ions is discharged.
After extended use, you may notice dust around
the grills or front panel.
• This is caused by negative ions exiting the air
outlet, evidence of the ioniser’s air cleaning
effectiveness.
• You can remove the dust with a soft brush or
clean, damp cloth.
Larger particles may be attracted to positively
charged surfaces throughout the home, like walls
or fl oors.
•
This may occur more frequently when the fi lter
is nearing the end of its useful product life and
unable to capture as many charged particles.
• Excessive amounts of pet dander, dust, or
smoke may decrease the life expectancy of
the fi lter(s) and interfere with the ionisation
process.
To help prevent particles from attracting to
surfaces throughout your home:
• You may want to run the ioniser less often.
• Check the condition of the fi lter(s) more
frequently.
CAUTION: The ioniser in this appliance
produces less ozone than the UL* established
limits of 50ppb. However, in high concentrations,
ozone can be harmful to birds and small pets.
To prevent ozone buildup, we suggest using the
ioniser in well ventilated areas with the fan on.
NOTE: it is important to change the
HEPA-type fi lter at recommended intervals. Using
the ioniser in conjunction with dirty fi lters may
result in dirty particles exiting the air purifi er and
being attracted to walls, carpets, furniture and
other household objects. These dirty particles
may prove very diffi cult to remove.
PRE-OPERATING INSTRUCTIONS
1. Carefully unpack your air purifi er.
2. Select a fi rm level place where there are
no obstructions to the air inlet (rear grill) or
fi ltered air outlet.
OPERATING INSTRUCTIONS
1. Plug into a 220-240V electrical outlet.
2. Press the Power button (
).
3. You can then press the Speed button
( ) for the desired speed setting: HIGH (3),
MEDIUM (2), or LOW (1).
4. To release negative ions into the fi ltered air,
press the Ioniser button (
) and the light will
illuminate.
5.
You may set the timer so that it automatically
turns off when the desired time has elapsed.
Press the Timer button ( ) until you reach
the desired number of hours you want the unit
to operate (2, 4 or 8). The number of hours
will light up and remain illuminated. When the
time has expired, the air purifi er will turn off. To
cancel the timer, press the Timer button ( )
one more time. You may also cancel the timer
operation by turning the Power button off.
CLEANING AND MAINTENANCE
1. Turn the air purifi er off and unplug it before
cleaning.
2.
The outside of the air purifi er can be cleaned
with a soft, clean dampened cloth.
3. The fi ltered air outlet on the back of the unit
can be cleaned of dust with a small, soft
brush.
4.
If you wish to clean the inside of the air
purifi er, please only use a dry, soft cloth to
wipe it down.
U.K. and IRELAND
Fig.2
A
C
B
E
F
J
H
K
FILTER REPLACEMENT
IMPORTANT: IN ORDER TO RETAIN THE
EFFICIENCY OF YOUR AIR PURIFIER, THE
HEPA-TYPE FILTERS NEED TO BE CHANGED
EVERY 3-6 MONTHS. THE FILTER SERVICE
INDICATOR LIGHT (L) WILL TURN RED WHEN
IT IS TIME TO REPLACE THE HEPA-TYPE
FILTERS.
1. Every few weeks check the condition of the
pre-fi lter.
2. Remove the inlet grill by pressing down on
the knob at the top. If the foam pre-fi lter
has collected a noticeable amount of dust,
remove it from the inlet of the grill and wash
it in warm soapy water. Rinse and dry the
pre-fi lter thoroughly before replacing it in the
inlet of the grill.
3. With the inlet grill removed, remove the
HEPA-type fi lters and dispose in the dust bin.
DO NOT try to wash and re-use the fi lters.
Replace with two new HEPA-type fi lters or
True HEPA fi lters against smoke, removing
the protective plastic bag before inserting into
the air purifi er.
4. Align the clips on the side of your fi lter with
the rails on the inside of the unit. Gently slide
the fi lter onto the rails.
5. The fi lter clip should easily slide onto the fi lter
hang tabs. Do not use force while attaching
the fi lter clip to the fi lter. Align the clip on the
side of your fi lter with the rails on the inside
of the unit.
NOTE: The pleated material and rubber
gasket should be facing towards the unit
when applied.
6. Replace the inlet grill by positioning bottom
of grill and then snapping back on to the unit.
Make sure that it fi ts securely into position
(the grill only goes on one way)
NOTE: Do not point outlet towards wall.
7. The fi lter service indicator light should be
reset once the fi lters have been replaced.
Reset by pressing down 3 seconds on the
fi lter reset button (I).
REPLACEMENT FILTERS
BAPF30B HEPA-type fi lter (usage 2 pcs).
BAPF300 True HEPA fi lter (usage 2 pcs.) --
Helps remove up to 99.97% of airborne particles
as small as 0.3 microns, including tobacco
smoke.
UK - Filter Sales Order Line -
0870 759 9000
TROUBLESHOOTING
Problem Solution
• Unit will not
operate.
• Decreased
air fl ow.
✔
Check to make sure the
unit is plugged in.
✔
Check to make sure the
unit is on by pressing
the power button.
✔
Make sure the fi lters are
properly installed and
fi rmly close the door.
✔
If the fi lters have not
been changed for 6
months or more, change
the HEPA-Type fi lters.
✔
Check to ensure nothing
is blocking the air inlet
and fi ltered air outlet.
Fig.1
I
D
G
*tested and listed by the Underwriters
Laboratories, Inc.
L