PLEASE READ AND SAVE THESE
IMPORTANT INSTRUCTIONS.
With proper care and use, this Bionaire™ air purifier
will give you fresh, clean air for many years.
NOTE: Before reading these instructions, please
view the corresponding illustrations.
DESCRIPTIONS (SEE FIG 1/4)
A.Inlet Grill
B.Washable Foam Pre-Filter
C.HEPA/Carbon Filter
D.Filtered Air Outlet
E.Filter Indicator Light
F. Oscillation Button
G.Ionizer Light
H.Ionizer Control
I. Power Button
J. Speed Control
SAFETY PRECAUTION
Carefully read and retain all instructions before
using the air purifier.
•To avoid fire or shock hazard, check that the
voltage on the product corresponds to your
electricity supply and plug directly into an
electrical outlet.
•To avoid fire hazard, never put the cord under
rugs, or near any heat source.
• Carefully discard any plastic wrapping that was
used for the packaging.
• Do not use the air purifier outside.
• Do not place the unit near any heat source or
in direct sunlight.
• Always unplug the air purifier before removing
the grill, changing the filters, cleaning the air
purifier or whenever it is not in use.
• Do not use in or around water or any other liquids.
Do not attempt to wash the unit under running
water.
• Use appliance only for intended household use
as described in this manual.
• Ensure that all air openings are not restricted
or covered in any way.
• Do not place anything on top of the unit.
• Never insert any object into any openings.
• Do not use the air purifier if any part is missing
or damaged in any way.
• Do not attempt to repair or adjust any mechanical
functions of this unit. If the unit becomes damaged
return to the place of purchase or phone the
helpline number on the back of this leaflet.
• If the supply cord or plug is damaged, it must
be replaced by the manufacturer or its service
agent or a similarly qualified person in order to
avoid hazard.
• The air purifier contains no user serviceable
parts and should the product suffer damage or
breakdown it must be returned to the manufacturer
or its service agent.
• Should the air purifier stop working, first check
the fuse in the plug (UK only) or fuse/circuit breaker
at the distribution board is operating, before
contacting the manufacturer or service agent.
HOW THE AIR PURIFIER WORKS
Dirty, dust laden air is drawn through the rear of
the air purifier and through the multi-stage filtration
system.
1. The carbon filter will help clear odours making
the air cleaner and fresher.
2. The HEPAfilter entraps 99% of all smaller visible
and non-visible particles down to 2 microns in
size.
PRODUCT FEATURES
Filter Life Indicator
Your air purifier has an indicator light that illuminates
when its time to change the filters.
Ionizer
Your Bionaire™ Air Purifier has an independently
controlled ioniser, which when turned on, releases
negative ions into the outgoing filtered air. Ions
are tiny particles that carry either a positive or
negative charge. These ions exist naturally all
around us in the air, water and ground. Both positive
and negative ions are colourless, odourless and
completely harmless.
Negative ions help the air purification process by
attaching themselves to very small airborne particles
in the room. These particles take on a negative
charge and may join with positively charged particles,
such as dust, pollen, smoke and pet dander to form
larger particles that are then more readily captured
by the filter system, or they may be attracted to
positively charged surfaces like walls or floors.
You may also note, after extended use, that dust
may have collected around the grills or front panel.
This is from the ionisation effect caused by the
negative ions exiting from the air outlet.This dust
does not come from the air output, but is drawn
out of the uncleaned air going past the air outlet.
This is additional evidence of the air cleaning
effectiveness of negative ions. The dust can be
easily removed with a clean, dampened cloth or
soft brush.
NOTE: it is important to change the HEPA filter
at recommended intervals. Using the ioniser i n
conjunction with dirty filters may result in dirty
U.K. and IRELAND
particles exiting the air purifier and being attracted
to walls, carpets, furniture and other household
objects. These dirty particles may prove very difficult
to remove.
PRE-OPERATING INSTRUCTIONS
1. After removing the unit from the box, remove
the plastic covering from the unit.
2. Select a firm level place where there are no
obstructions to the air inlet (rear grill) or filtered
air outlet.
3. Remove the inlet grill by pulling the grill towards
you.
4. Remove both HEPAfilters by gripping on both
sides and pulling forward.
5. Remove protective plastic bag from each filter
cartridge. The filter clip can only be attached
to the hang tabs on the filter one way (see fig 3).
The filter clip should easily slide onto the filter
hang tabs. Do not use force whilst attaching
the filter clip to the filter. Align the clip on the
HEPAfilter with the rails on the inside of the unit.
NOTE: The pleated material and rubber gasket
should be facing towards the unit when applied.
6. Replace the inlet grill by sliding back on to the
unit. Make sure that it snaps securely into position
(the grill only goes on one way).
NOTE: Do not point outlet towards wall.
OPERATING INSTRUCTIONS
1. Plug into a 220-240V electrical outlet.
2. Press the Power button ( ). The unit will turn
onto high and the power light will illuminate letting
you know the power is on.
3. You can then select the desired speed setting.
This air purifier has three speed settings. You
can select from HIGH ( ), MEDIUM ( ),
or LOW ( ) by pushing the desired operating
speed button on the control panel or the remote
control. (For BAP825RC)
4. To release negative ions into the filtered air,
press the Ionizer button ( ) to ON and the
light will illuminate.
5. To start and stop oscillation of the air purifier,
push the button identified as Oscillation ( )
on the remote control (For BAP825RC) or
control panel.
6. For optimum air filtration, it is recommended
to operate the air purifier continuously. Its rugged
motor has been designed to give many years
of use.
For continuous use, it’s recommended to operate
the air purifier at the MEDIUM setting. For quieter
operation or use in a bedroom, select the LOW
setting. When high levels of air pollution are present,
select the HIGH setting to quickly circulate and
filter the room air.
REMOTE CONTROL
(ONLY FOR MODEL BAP825RC)
Your remote control requires (2) AAAbatteries for
operation. To install the batteries, simply depress
and slide the back of the remote control with your
thumb on the arrow indentation. Insert batteries
according to the diagram shown inside and replace
cover.
• DO NOT mix old and new batteries.
• DO NOT mix alkaline, standard (carbon-zinc)
or rechargeable (nickel-cadmium) batteries.
1. Set tower air purifier on a dry, level surface.
2. Plug cord into any standard 220-240V outlet.
3. To turn the air purifier on, press the Power
button ( ) and then select the desired
operating speed by pressing any speed button
on the remote control or on the control panel.
4. The speed is adjustable by pressing either the
Speed Button on the remote control or on the
control panel.
5. To turn the unit off, press the Off button ( ) on
either the remote control or on the control panel.
6. To start and stop oscillation of the air purifier,
push the button identified as Oscillation ( )
on the remote control or control panel.
7. To release negative ions into the filtered air,
press the Ionizer button ( ) to ON and the
light will illuminate.
CLEANING AND MAINTENANCE
1. Turn the air purifier off and unplug it before cleaning.
2. The outside of the air purifier can be cleaned
with a soft, clean dampened cloth.
3. The filtered air outlet on the top of the unit can
be cleaned of dust with a small, soft brush.
4. If you wish to clean the inside of the air purifier,
please only use a dry, soft cloth to wipe it down.
FILTER REPLACEMENT
IMPORTANT: IN ORDER TO RETAIN THE
EFFICIENCY OF YOUR AIR PURIFIER, THE
HEPAFILTER NEEDS TO BE CHANGED EVERY
6-9 MONTHS.
1. Every few weeks check the condition of the
pre-filter.
2. Remove the inlet grill. If the foam pre-filter has
collected a noticeable amount of dust, remove
it from the inlet of the grill and wash it in warm
soapy water. Rinse and dry the pre-filter thoroughly
before replacing it in the inlet of the grill.
3. With the inlet grill removed, remove the HEPA
cartridge and dispose in the dustbin. DO NOT
try to wash and re-use the HEPAfilter. Replace
with a new HEPAfilter-BAPF30 removing the
protective plastic bag before inserting into the
air purifier.
2
3