Warnings & Important information
– For continued safety of this appliance it
must be installed, operated and maintained in accordance with the manufacturer's instructions.
– Your appliance should be installed by
a suitably qualified tradesperson.
– For correct operation of this appliance
it is essential to observe the instructions as outlined in this booklet.
– Do not use this appliance with water that
is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
– Filter replacement must be performed
at intervals of not more than 12 months.
– Use this appliance only as directed
in these instructions and only for its designed purpose.
– This appliance is not intended for use
by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
– Children should be supervised to ensure
that they do not play with the appliance.
– If the supply cord is damaged, it must be
replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid creation of a hazard.
– New hose sets supplied with the appliance
are to be used. Old hose sets should not be re-used.
2
Page 3
User guide Billi Alpine Sparkling.
General Maintenance
Your Billi Alpine has been designed to require minimal maintenance other than replacement of filter cartridges. During each filter change, check all water connection fittings for signs of leakage. Check all tubing for any signs of damage. Check the cupboard area around the base of unit for any signs of moisture.
Cleaning the dispenser
Your Alpine Dispenser is fabricated from robust metal with a tough protect chrome plating. Care of dispenser is as with any chrome plated tapware. Avoid using abrasive cleaners. Wipe clean using a damp cloth. Use of a non-solvent, non-smearing cleaner such as Windex is recommended. Do not pour water over dispenser.
Cupboard ventilation requirements
Your Alpine Sparkling underbench module requires cupboard ventilation, refer to install guide for details. Care should be taken when using the cupboard space, to avoid stretching or damaging plastic pipe work. Check fittings and tubing at each filter change for signs of damage or leakage. Always ensure access to power switch and water supply tap is not restricted.
Features and Modes
Slimline Dispenser
To dispense filtered water, the dispenser tap lever will need to be rotated. The lever will automatically return to the o position. The spout can be swivelled to suit your installation.
Billi Filter Cartridges
The Billi Alpine uses environmentally friendly, element-type cartridges. The two-stage system includes a Sediment Removal pre-filter and Chemical Removal post-filter.
There are 2 types of filter cartridge sets oered.
994001 This is the standard filter cartridge set used in the Alpine system. This combination is designed to remove or reduce sediment, taste and odour, chlorine, chemicals and pesticides. This combination is rated to remove particles greater than 10 microns in size and is best suited to normal quality town water supplies.
994002
Use only genuine Billi Filter Cartridges as designed for this system.
If the system has not been used for a period of 3 days or more, lift the dispenser lever and flush the system for at least 1 minute.
This combination incorporates a high quality, sub-micron, carbon block filter and is NSF certified for the safe removal of potentially healththreatening Giardia and Cryptosporidium cysts. As well as removing or reducing the contaminants as listed for the 990402 cartridge etc., the chemical cartridge is certified to remove or reduce heavy metals such as lead; an unseen potential health hazard.
Adjustable chilled water temperature
The chilled water deilvery temperature can be adjusted to suit your preference. The blue control knob, located on the front of the Chiller Module, can be adjusted if a cooler or warmer temperature is required.
3
Page 4
User guide Billi Alpine Sparkling.
Filter Cartridges Service Interval
Periodic replacement of your Billi Alpine filter cartridge is necessary to maintain the sparkling freshness of your drinking water.
Your Billi Representative will advise you of an appropriate service interval. As a guide, the filters should be serviced twice yearly. In areas where water supply has a high level of sediment, more frequent replacement of filter cartridges may be necessary. This will become evident when a significant drop in delivery flow rate occurs.
Filter Cartridge Replacement
When you receive your replacement cartridges, follow the procedure as outlined below:
1. Turn o blue tap under bench.
2. Operate dispenser lever to release pressure.
3. Hold filter and swing towards you slowly. The top of the filter is in a hinged cradle assembly. It should stop after approximately 30 degrees of travel.
4. The filter can now be released from the
holding cradle by pulling down on the filter.
5. Take care not to spill water in the base of the tray. If so wipe gently with absorbent paper.
6. Install new filter into the same location by pushing all the way up into the cradle.
7. Push filter back into the unit until it locks into place.
8. Turn on blue tap under bench and check for water leaks.
9. Operate dispenser lever and run water for 3 minutes to flush and condition the new filter.
4
Page 5
User guide Billi Alpine Sparkling.
Removing the CO2 cylinder
1. Isolate the water supply and turn o the power.
– This will prevent the internal pump
from pressurizing the system.
2. Turn o the CO black knob anti-clockwise.
3. Drain any remaining pressure by activating the sparkling water option on the dispenser installed.
Ensure the pressure gauge shows near to
zero pressure – if the pressure is less than one bar, and the dial is fully anti-clockwise, then the cylinder can be removed with only a small amount of CO
4. Hold the regulator and rotate the Cylinder clockwise to remove.
– If the bottle is not empty, CO
while you are turning the bottle. The bottle will self-seal prior to the thread being free from the regulator.
– Avoid breathing air containing CO
contact with the cold escaping gas as per the Safety Data Sheet.
regulator by turning the
escaping
may escape
or
5
Page 6
User guide Billi Alpine Sparkling.
Installing the CO2 cylinder
1. Ensure all connections between the regulator and unit are secure.
Position the regulator on top of the CO
cylinder.
2. Tighten the bottle by rotating anti-clockwise.
– CO
will escape while you are turning the
bottle. Continue to turn the bottle to form a seal with the regulator.
3. Open the pressure regulator by turning the black knob clockwise.
– Set the initial pressure to around 3 Bar. – Turn on the unit power and water supply. – Wait for the unit to come back to
temperature.
4. Check bottle and connections for leaks using soapy water to test for bubbles.
NOTE: the ¼" tube and pushfit fittings may settle when the pressure is turned on.
5. Increase the pressure to set your level of carbonation.
Initial set point may vary once the unit is
running, you may need to reset the pressure once the system has stabilised.
WARNING: do not set the pressure above 5 bar.
6
Page 7
User guide Billi Alpine Sparkling.
Thank you for choosing to install a Billi Alpine Sparkling Drinking Water Appliance. Your Alpine Sparkling is manufactured to exacting standards using high quality materials and with proper maintenance and care, should function for many years.
For information on our filtration and service contract please contact Billi Head Oce on 1800 812 321 or email us at service@billi.com.au.
For technical support please call 1800 812 321 and speak to one of Billi’s experienced technician’s.
To book a service call out request a filter change or please contact the Billi Service Centre on 1800 812 321 or book online at www.billi.com.au
Filter cartridges are also available for purchase online at www.billi.com.au