Installation guide
B-5000 Sparkling
Tap option XL
Installation requirements.
XL
— Components for B-5000 Sparking
Before commencing installation,
ensure you have identified the following.
1. Boiling water module
2. Chilled water module
3. Sparkling control box
4. CO2 regulator and cylinder
5. Dispenser upper with tubing
6. Dispenser base & mount
7. Barb locking bush
8. 4mm chrome screw & allen key
9. Large washer
10. Tube spring clamps x 3
11. 90° John Guest elbow
12. White 1/4” tube x 3
13. 600mm flexible braided hose
14. Filter cartridge (installed)
15. User guide
16. Warranty registration card
17. Warning label
Power
Outlet x 2
Cupboard dimensions:
555mm minimum width
460mm minimum depth
Stop tap
(installed by plumber)
Max 600mm from unit
800mm
Tube length
supplied
60mm
Minimum
clearance
—Determine Unit Location
Plan the installation. Dispenser tube lengths,
position of power and water outlets, required
air space around the underbench modules and
access for service must be considered before
cutting tube lengths refer to Diagrams 1,3a
and 3b for clearances around units. Refer to
Diagrams 4a and 4b for suggested layouts.
—Water Supply
The B-5000 Sparking must only be connected
to a cold water supply. A ½” BSP stop tap
(not supplied) is to be installed in an easily
accessible position within 600mm from
the boiling water module water supply inlet.
Dynamic water supply pressure:
Min. 250 kPa, max. 1000 kPa.
Minimum water supply: 6 l/m at 250 kPa
Supply temp: min. 5°C, max. 30°C.
Do not install with water that is
microbiologically unsafe or with water of
unknown quality without adequate disinfection
before or after the system. Systems certified
for cyst reduction may be used on disinfected
water that may contain filterable cysts.
185mm
215mm
10mm
Bench
thickness
1mm-54mm
Diagram 1
20mm
145mm
35mm 100mm
Diagram 2
—Power Requirements
Two 3 pin 10 amp GPOs are required. A
dedicated circuit should be provided and must
be fitted with an earth leakage protection
device (RCD). An externally fitted RCD device is
acceptable.
Both B-5000 Sparkling modules are supplied
with a 1 metre flex cord and plug.
Installation requirements.
50mm
150mm
50mm
555mm
440mm
50mm
150mm
50mm
620mm
375mm
XL
Chilled Water Module Dimensions
240mm
385mm 385mm
FRONT
240mm
325mm
SIDE
325mm
TOP
Diagram 3a
Boiling Water Module Dimensions
20mm
180mm
340mm
FRONT
20mm
365mm
340mm
SIDE
365mm
180mm
TOP
Diagram 3b
B-5000 Sparking Suggested Layout A (Plan) B-5000 Sparking Suggested Layout B (Plan)
620mm
50mm
150mm
50mm
375mm
150mm
50mm
50mm
Diagram 4a Diagram 4b
Note: Shaded area shows ventilation clearanceNote: Shaded area shows ventilation clearance
555mm
440mm
3