Biamp Tesira HD-1 Installation & Operation Manual

A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA T: +1 503.641.7287 W: www.biamp.com
MARCH 2019
Setup and Use
The Tesira software provides an intuitive interface for setup and programming of the HD-1. The information supplied by this manual relates to physical connections and device setup. For more details on software setup, please consult the Tesira Help File.
All standard telephony functions, including dialing, the ability to answer and make calls, mute, conference and redial are available from the HD-1, which connects to a single VoIP or POTS line on a Tesira system. A second HD-1 cannot be assigned to a telephony line that’s already being controlled by another HD-1.
Installation
Install the unit away from heat sources, such as vents and radiators, and in rooms with adequate ventilation. Ensure that air can circulate freely around the unit. Do not exceed the maximum ambient operating temperature of 32°­104° F (0° - 40°C).
Default Network Conguration
The HD-1 by default uses a link-local (Auto) IP address. This allows the device
to receive its network conguration from a DHCP server. This enables the
HD-1 to be discovered by a Tesira SERVER-IO, SERVER or TesiraFORTÉ device that also has default IP settings.
The default HD-1 hostname is “HD-1-” followed by its serial number. The Network settings and hostname can be edited and assigned via Device Maintenance in the Tesira software.
Tesira software provides programming of all remote functions, network setup, device naming, and device maintenance.
Device information such as IP, MAC address and device serial number will be
displayed on the main screen when the device is un-congured or by pushing
the Select/Device Info button on the keypad.
Tesira® HD-1 Dialer
Installation & Operation Guide
Product Description
The Tesira HD-1 is a hardware dialer for Tesira audio DSPs. The HD-1 is compatible with Tesira SERVER and SERVER-IO with STC-2 or SVC-2 cards installed. The HD-1 is also compatible with the following TesiraFORTÉ models:
TesiraFORTÉ TI TesiraFORTÉ AVB TI TesiraFORTÉ DAN TI TesiraFORTÉ VI TesiraFORTÉ AVB VI TesiraFORTÉ DAN VI
TesiraFORTÉ VT TesiraFORTÉ AVB VT TesiraFORTÉ DAN VT TesiraFORTÉ AVB VT4 TesiraFORTÉ DAN VT4
A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA T: +1 503.641.7287 W: www.biamp.com
MARCH 2019
Tesira HD-1 Dialer - Keypad Functions
1. Volume Control 9. Call Appearance One
2. Mute 10. Call Appearance Two
3. LCD Display 11. Hold
4. Context (Soft) Buttons 12. O󰀨 Hook
5. Scroll Up/Down 13. On Hook
6. Select/Device Info 14. Last Number Redial
7. Numeric Keypad 15. Directory/Speed Dial
8. Conference 16. Flash
Network Connection
One Ethernet port is provided for connecting the HD-1 to the network. The network connection should be made with CAT5, CAT5e, CAT6 or CAT7 cabling.
This connection is made to the Ethernet port of a Tesira SERVER-IO, SERVER or TesiraFORTÉ device, either directly (single station) or via a network switch and carries control data over Ethernet.
PoE-enabled network switches or PoE midspan adapters (injector) must be used to power the unit. These must be 802.3at Type 1 com­pliant. The maximum cable distance between any unit and an Ethernet switch is 328 feet (100 meters) when using copper cabling.
Additional Ethernet switches and/or ber-optic cable can be used to
further extend distances between units on a network.
HD-1
HD-1
Non-PoE Ethernet
Switch
PoE Injector
PoE Ethernet Switch