
AMP-450P PRODUCT DESCRIPTION
The AMP-450P is a four-channel AVB PoE+ amplifier for use in Tesira® systems. The output channels are software
configurable including selectable power versu s channel count. PoE+ power allows the AMP-450P to be placed wherever
you need it. Suitable for air-handling spaces, t he am plifier can be located close to ceiling speakers if desired. The AMP450P includes an internal limiter and can provide 3W RMS of continuous power to all four channels. The Tesira AMP450P is also capable of operating in a “burst” mode to support higher power levels for dynamic content for brief period s.
The amplifier serves as a dedicated endpoint in a T esira system, making installations easier to design, support and
maintain. The AMP-450P is ideal for Tesira-equipped conference rooms and other applications.

AMP-450P SETUP AND USE
Setup and Use
The Tesira software provides an intuitive interf ace f or setup and programming of the AMP-450P. The information supplied
by this manual relates to physical connections and device setup. For more details on software setup, please consult the
Tesira Help File. For device specifications please consult the AMP-450P Datasheet.
The Tesira AMP-450P does not connect to Telecom Network V oltage (TNV) circuitry and is considered a Network
Environment Zero device.

Front Panel and Connectors
Powered but not ready to receiv e configuration
Ready to receive configurati on or updating firmware
Configured and ready to parti c ipate in the system
Amplifier is in Locate mode (triggered from the software)
Unit has Major Alarm condition
Unit has Minor Alarm condition
Unit has both a Major and Minor Al arm condition
Amplifier limiter engaged
Amplifier is in Locate mode (tr iggered from the software)
Amplifier has failed to initialize, an error is present, or the
amp is temporarily muted due to an a udio burst
PoE+ power is not available or insufficient to power the
amplifier so it has been turned off
AMP-450P FRONT PANEL
Figure 1 AMP-450P Front Panel
AVB / Control
1.
Facilitates connection to the Tesira AVB network for audio and control. This RJ-45 port may either be connected
directly to the Tesira AVB port (via a PoE+ injector) for a single device system or via a PoE+ network swit c h in a
multi-device AVB system. IEEE 802.3at Power ov er Ethernet Plus (PoE+) Class 4 is required as there are no
other provisions for power inlet.
Power/System Status
2.
A multi-color LED provides information about the status of the device.
Amp Status
3.
A multi-color LED provides information about the status of the amplifier.
Output 1 - 4
4.
4 x 3W RMS or 2 x 7W RMS or 1 x 15W RMS output at low impedance 4Ω / 8Ω.
Red Flashing
Red & Yellow Flashing

AMP-450P WIRING TOPOLOGIES
Amplifier Output and Wiring
The amplifier can be configured in either single channel, two-channel or four-channel mode in the Tesira soft ware. Any
unconfigured channels will not pass audio ev en i f speakers are connected.
1 x 15W RMS
2 x 7W RMS
4 x 3W RMS
Figure 2 Amplifier Speaker Wiring 1 x 15W RMS
Figure 3 Amplifier Speaker Wiring 2 x 7W RMS
Figure 4 Amplifier Speaker Wiring 4 x 3W RMS

AMP-450P INSTALLATION
Mounting & Installation
Flanges on each side of the unit have mounting holes to secure the AMP-450P with hardware (not provided) if desired. An
optional seismic cable may be installed through t he center hole on the left mounting flange in lieu of hardware mounting.
Installation Distance Requirements:
• 330 feet (100 meters) maximum from the Ethernet switch to the AMP-450P.
To install the optional seismic cable, place the unit in the desired location:
1. Feed the seismic cable through the hole in AMP-450P mounting flange.
Figure 5 AMP-450P Seismic Cable Mounti ng
2. Feed the cable through one end of the locking mechanism.
NOTE: The ends indicated by the blue arrow need to be depressed to allow the cable to pass through. Internal
guides ensure the cable will be routed through the co rrect path.
3. Attach the loop to a secure location and apply sufficient tension for minimal slack.
4. Make sure the ends of the lock mechanism are in the loc ked position (out) as indicated by the blue arrows.
Figure 6 Lock Mechanism Orientation
Visit www.biamp.com to obtain firmware and software updates related to this product. To speak with an Applications Engineer, please call
1.503.641.7287 or email support@biamp.com
.

FCC NOTICE
FCC Part 15 –
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference and (2) this device must accept any interference received, including
interference that may cause undesired operation.
The following applies to products with a telephone i nterface:
This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the rear of
this equipment is information that contains a product identifier in the format US:6RMEQ##TXXXX. If requested, this
number must be provided to the telephone company.
This equipment is designed for modular connection with Jack Universal Service Order Codes RJ-14C, RJ-14W.
A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with t he
applicable FCC Part 68 rules and requirements adopt ed by the ACTA.
CAUTION: To reduce the risk of fire, use only No. 26 AWG or larger (e.g., 24 AWG) UL Listed or CSA Cert i fied
Telecommunication Line Cord.
The Ringer Equivalence Number (REN) is used to det ermi ne the number of devices that may be connected to a
telephone line. Excessive RENs on a telephone line m ay result in the devices not ringing in response to an incoming
call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices
that may be connected to a line, as determined by the t otal RENs, contact the local telephone company. F or
products approved after July 23, 2001, the REN for this product is part of the product identifier that has the f ormat
US:6RMEQ##TXXXX. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0. 3).
For earlier products, the REN is separately sho wn on the label.
If this equipment causes harm to the telephone net work, the telephone company will notify you in advanc e that
temporary discontinuance of service may be requi red. But if advance notice isn't practical, the telephone company
will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if
you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the
operation of the equipment. If this happens the telep hone company will provide advance notice in order for y ou to
make necessary modifications to maintain uninterrupted service.
This equipment is not user serviceable. If trouble is experienced with this equipment, for repair or warranty
information, please contact Biamp Systems Corp orat ion, phone number 503.641.7287. If the equipment i s causing
harm to the telephone network, the telephone company may request that you disconnect the equipment un til the
problem is resolved.
Connection to party line service is subject to state t ari f fs. Contact the state public utility commission, public serv ice
commission or corporation commission for information.
If your facility has specially wired alarm equipment connected to the telephone line, ensure the installation of this
equipment does not disable your alarm equipment. I f you have questions about what will disable alarm equipment,
consult your telephone company or a qualified in stal l er.