BHI NEIS-RM Installation And Operating Manual

NEIS-RM Intercom Operating Manual
NEIS-RM Intercom Operating Manual
Page 1
1080-100D
Issue C
bhibhi
bhibhi
bhi
Noise Eliminating Intercom System
Installation
and
Operating Manual
Remote Microphone Version
Page 20
bhibhi
bhibhi
bhi
DSP noise cancellation product s
DSP Noise Cancellation
bhi Ltd
PO Box 318
Burgess Hill
West Sussex
RH15 9NR
England
tel: +44 (0)845 217 9926
fax: +44 (0)845 217 9936
sales@bhi-ltd.com
www.bhi-lt d.com
NEIS-RM Intercom Operating Manual
NEIS-RM Intercom Operating Manual
Page 2
Important Information
Copyright
This publication, including all photographs and illustrations is protected under international copyright laws, with all rights reserved. Neither this manual, nor any of the material within, may be copied or reproduced without the written consent of bhi Ltd.
Disclaimer The information in this document is subject to change without notice. bhi Ltd. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, bhi Ltd. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of bhi Ltd. to notify any person of such revision or changes.
Page 19
< page intentionally blank >
NEIS-RM Intercom Operating Manual
NEIS-RM Intercom Operating Manual
Page 3
Packing List:
Please check the contents of the box.
• Operating manual
NEIS-PSU - Medical power supply with worldwide adapters
• NEIS-MIC - Remote microphone
• NEIS-DU - Desk console
• NEIS-SPKR - Loudspeaker unit
Note: We recommend that installation be carried out by qualified personnel. Please study this manual before attempting to install the intercom.
T o install this intercom you will need the following additional items:
• CAT5 network cable/connections (straight-through).
• Suitable fixings for mounting the loudspeaker
Suitable tools for installation of the above
Page 18
< page intentionally blank >
NEIS-RM Intercom Operating Manual
NEIS-RM Intercom Operating Manual
Page 4
1. Introduction 6
1.1 System overview 6
1.2 Features 7
2. Intercom description 8
2.1 Intercom components 8
2. 2 Intercom component description 9
2.2.1 Loudspeaker unit 9
2.2.2 Remote microphone 9
2.2.3 Desk console 9
3. Installation 11
3.1 Basic installation 11
3.2 Power supply 11
3.3 Loudspeaker mounting 11
3.4 Cable connections 12
3.5 Desk console 13
4. Operation 14
4. 1 Desk console controls 1 4
4.2 Loudspeaker controls 15
4.3 Noise cancellation level setting 1 6
Contents
Page 17
leveL noitcudeRenoT
esioNetihW
noitcudeR
1Bd4Bd9 2Bd5Bd11 3Bd6Bd31 4Bd8Bd51 5Bd61Bd71 6Bd12Bd02 7Bd52Bd42 8Bd56Bd53
Table 1. Tone and noise reduction levels.
leveL )6-5(5J )4-3(5J )2-1(5J
1nOnOnO 2nOnOffO 3nOffOnO 4nOffOffO 5ffOnOnO 6ffOnOffO 7ffOffOnO 8ffOffOffO
Table 2. Preset DSP levels using on board jumpers.
The DSP levels are set by the following combination of jumpers.
4. Operation.
NEIS-RM Intercom Operating Manual
NEIS-RM Intercom Operating Manual
Page 5
Weee Statement for correct disposal of this product
(Applicable in the European Union and other European countries with separate collection systems). This marking shown on the product or its literature, indicates that it should not be disposed of with other household wastes at the end of its working life. T o prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.
Page 16
4. Operation.
4.3 Noise cancellation level.
Figure 9. Bottom view of desk console.
Noise cancellation
jumper plugs
Desk console
When the jumper is placed over the two pins the jumper is ON. When the jumper is connected to one pin only , or removed from the board it is OFF . To reduce the risk of losing the jumper it is advised to place it on one pin when using the OFF position.
J5 pins
ON
OFF
2
3
5 6 1
Figure 10. Jumper details.
The noise cancellation filter level is set to the optimum position (level
7). However the noise reduction may be changed to suit the specific requirements of the installation. The unit has a choice of 8 levels of noise reduction, these are set by 3 jumper plugs accessible from the bottom of the desk unit, underneath the serial number label. The jumpers can be changed using a small pair of snipe nosed pliers or similar tool
NEIS-RM Intercom Operating Manual
NEIS-RM Intercom Operating Manual
Page 6
1. Introduction.
1. Introduction.
1.1 System overview:
The bhi NEIS Noise Eliminating Intercom System enables clear voice communications from within noisy environments. Using unique Digital Signal Processing (DSP) technology, unwanted noise and interference picked up by the microphone in the communication can be removed from the signal to leave clear intelligible speech.
The NEIS is suit able in a wide range of noisy applications, where the sounds of fans, motors, engines, air-conditioning, traffic etc., give rise to poor voice communications. The system is particularly useful for improving the voice quality in medical and industrial environments, where noisy machines can make voice communication difficult.
Using minimal hardware components, the installation and operation of the bhi intercom system is very easy, connections being made via a single cat 5 data cable. The NEIS is pre-configured for optimum noise cancelling, and is fully adaptive to changing environmental conditions. It is suited to a variety of applications, where clear “noise free” two-way voice communications are important, including: Hospital radiotherapy/radiology treatment rooms, mines, railway and transport depots, customer help points, factories & office communications. In fact the NEIS provides a simple effective solution for anyone trying to communicate from within a noisy environment. Simply plug in the power and the system is ready to go.
The NEIS consists of a stylish, robust, desktop speaker control unit, with a “push-to-talk” button, connected to a remote “hands free” speaker unit, with a remote microphone attached. This allows the noisy location to be constantly monitored, an important feature for safety critical environments.
Page 15
4. Operation.
4.2 Loudspeaker control.
Figure 8. Rear view of loudspeaker unit
The volume of the loudspeaker can be adjusted by the rear mounted control.
Push To T alk The desk console unit default mode is to listen to the remote speaker, all speech at the remote speaker will be heard when the unit is switch on. Press and hold the Push-to-talk (ptt) switch to enable communication to the remote speaker, release the button to hear a response back from the user.
Remote Privacy For privacy at the remote speaker end, turn the system off using the Volume ON / OFF control on the desk console unit.
Note: Using this function will mean that the user will no longer be
monitored.
NEIS-RM Intercom Operating Manual
NEIS-RM Intercom Operating Manual
Page 7
1. Introduction.
1.2 Features:
Up to 98% noise reduction Clear two-way voice communications Superb audio quality using bespoke audio circuits Easy to install modular system Simple connection via single cat 5 computer cable Stylish desktop speaker console with “push to talk” function Robust speaker unit with remote microphone & separate
volume control
Noise filter Monitor switch On/off volume control switch Medical power supply 12 VDC (1.25A) Dims (WxDxH) Speaker unit 180 x 160 x 240mm Dims (WxDxH) Control unit 150 x 220 x 70mm
Page 14
4. Operation
4. Operation.
4.1 Desk console controls.
Figure 7. Rear view of desk unit
Power on/off
volume control
Noise cancellation
on/off switch
CAT 5 Loudspeaker
connector
Power
connector
Power On Off Ensure the power supply is plugged in at the wall socket and the wall socket is turned on. Using the on/off Volume control knob on the rear of the desk unit, turn on the unit.
Noise Cancellation The desk unit is pre-set for optimum noise reduction and adjustment is not normally necessary. The noise cancellation switch on the rear of the unit can be used to momentarily disable the noise cancellation system, hold the switch up in the off position and all noise will be heard from the remote speaker. Release the switch and the noise will be removed. Adjust the volume control for a comfortable listening level.
NEIS-RM Intercom Operating Manual
NEIS-RM Intercom Operating Manual
Page 8
2. Intercom description.
2. Intercom description.
2.1 Intercom components.
Figure 1. Intercom components.
Loudspeaker unit
Desk console
DC power supply
The NEIS consists of the following components:
Loudspeaker unit
Desk console Power supply Remote microphone
Page 13
3.5 Desk console.
Site the desk console unit in the quiet area. Connect the other end of the CAT5 cable to the loudspeaker socket, and the power supply into the power connector.
CAT5 cable from
loudspeaker
DC power supply
Desk console
Figure 6. Desk console connections.
3. Installation.
Remote “plug-in” microphone assembly
NEIS-RM Intercom Operating Manual
NEIS-RM Intercom Operating Manual
Page 9
2. Intercom description.
2.2 Intercom component description.
2.2.3 Desk console unit. The desk console unit is best located in a quiet area (normaly the equipment control room), and receives audio from the user in the noisy area through its small loudspeaker. It has a push-to-talk (ptt) button on the front to enable speech back to the user. The unit has a power on/off switch with volume control, a separate noise filter monitor switch on rear of the unit, a noise filter level select switch on the bottom of the unit. This unit contains the noise cancellation electronics to enable the removal of any noise that is present with the voice signal. The unit connects to the cat 5 cable via the connector on the rear of the unit.
2.2.1Loudspeaker unit. The loudspeaker unit mounts in a suitable location in the noisy area to give optimum voice quality to the user. The unit features a separate volume control, enabling the speaker output volume to be set up to suit the surrounding conditions and environment. The cat 5 cable connects at the rear of the unit.
2.2.2 Remote microphone. The remote microphone connects to the rear of the loudspeaker unit, and is best placed as near to the user as possible to obtain optimum audio performance. The most common routing of the microphone cable is through the ceiling and suspended down in-line with the patients face and as near to their mouth as possible. It can also be clipped inside the gantry using a standard plastic cable holder or ty-rap.
Page 12
3.4 Cable connections.
Figure 5. CAT5 cable connections.
3. Installation.
Connections: Connections are made using standard CAT 5 straight-through twisted pair RJ45 cables
NEIS-DU
NEIS-SPKR
7 = White/Brown 7 = White/Brown 8 = Brown 8 = Brown
1= White/Orange 2 = Orange 3 = White/Green 4 = Green 5 = White/Blue
1= White/Orange 2 = Orange 3 = White/Green 4 = Green 5 = White/Blue 6 = Blue
6 = Blue
NEIS-RM Intercom Operating Manual
NEIS-RM Intercom Operating Manual
Page 10
3. Installation
3. Installation.
3.1 Basic installation diagram.
Desk console
Power supply
Quiet area Noisy area
Remote
Microphone
Loudspeaker
CAT5 cable
Figure 2. Basic block diagram.
Figure 3. Power supply.
Push pins onto
power supply body
3.2 Power supply.
The medical power supply used for the NEIS is a modular unit, and consists of a modular pin unit and the power supply so as to accommodate the different types of voltage and connections around the world. Before the power supply can be used, plug the pin unit supplied onto the power supply body until it clicks into place.
Page 11
3.3 Loudspeaker mounting.
Figure 4. Loudspeaker connections.
Rear of speaker unit
Close up of
connections and
controls
Volume
control
Microphone
connector
CAT5 cable
connection
Microphone
3. Installation.
Mount the wall bracket supplied with the speaker unit in a suitable location in the noisy area, so that it optimizes the audio for the user. The microphone and cat 5 cable should be connected at the rear of the speaker before the speaker is secured into the bracket, and the microphone should be mounted at least 1 metre away from the speaker.
Loading...