Beyerdynamic MCW-D 521 User Manual

beyerdynamic GmbH & Co. KG Theresienstr. 8 | 74072 Heilbronn – Germany Tel. +49 (0) 71 31 / 617 - 0 | Fax +49 (0) 71 31 / 617 - 224 info@beyerdynamic.de | www.beyerdynamic.de
For further distributors worldwide, please go to www.beyerdynamic.com Non-contractual illustrations. Contents subject to change without notice. E5 / MCW-D 521 (11.09)
MCW-D 521
Order # 479.748
FEATURES
• Direct Sequence Spread Spectrum (DSSS) provides high immunity from interference and unauthorised listening
• Wireless transmission with integrated transmitting/receiving antenna in the 2.4 GHz frequency band which is approved world-wide
• Digitally encoded audio signals prevent unauthorised listening
• Integrated loudspeaker with voice equalisation
• Gooseneck microphone provides excellent audio quality
• Red illuminated ring around the gooseneck to indicate the ready-to-talk status of the microphone
• Microphone button to switch the microphone on / off or to register it in the system
• Dual colour LED for microphone ON (red: communication is established; green: microphone is switched on and ready for talking)
• DC-connection for DC-operation and battery charging
• Charging contacts
• Power on LED
• Mini stereo jack (3.5 mm) as documentation output for the connection of recorders, PCs with the steno-s recording software etc.
• High-quality plastic housing with charcoal-grey, non-glare and scratch-resistant Nextel
®
finish
• The following parameters can be programmed: loudspeaker level, auto-off behaviour and voice-controlled activation
• Auto-Off function when nobody speaks into the microphone
• Fixed ducking level of -15 dB for the loudspeaker when the microphone is activated
• Microphone unit can be programmed by using the configuration software with the control unit
• APO function for Automatic Power OFF when the control unit is in the stand-by mode or switched off
• Processor-controlled charging electronics to prevent the “memory effect” of the battery
• Reliable charging electronics ensures immediate use of the microphone units
• LED ring of the gooseneck microphone indicates charging status
• Maximum charging time of 2 hours when the battery (NiMH) is completely empty
• Operating time approx. 20 hours
1 of 6
MCW-D 521
DESCRIPTION
The MCW-D 521 delegate microphone unit is equipped with a microphone button in the housing with which the participant can switch his microphone on and off. With the Automatic Channel Allocation function the transmitting channels of the microphone units are allocated automatically. When the microphone button is pressed in the manual operating mode the request-to-talk is received by the control unit (a possible external dual colour LED will illuminate red). Then the control unit checks which of the available receiving channels is free. Then the control unit informs the micro­phone unit which channel it should use for transmitting. When the channel of the microphone unit is set and checked by the control unit, the microphone is switched on (dual colour LED changes from red to green). The ready-to-talk status of the microphone is also indicated by the red ring around the gooseneck microphone. In the Request-to-Talk-mode of the discussion system the request-to-talk is received, but the microphone is not switched on. The red LED indicates that the request-to-talk has been received. The micro­phone is switched on by the operator at the PC by using the “MCW-D 50 Conference” software or a media control system. When the microphone button is pressed once again, the delegate clears his/her request-to-talk.
Depending on the configuration with the “MCW-D 50 Conference” software the following operating modes are available: Override: the first microphone is switched off, when the maximum number of switched on microphones is exceeded. Voice activation: the microphone is switched on, when someone speaks into it. Push-To-Talk: the microphone button is held down, while the participant is speaking.
The integrated loudspeaker reproduces the audio signal of the whole conference system. Depending on the audio signal routing in the control unit the loudspeaker can reproduce other audio signals such as a wireless microphone in the auditorium.
The parameters of the microphone unit are adjusted via PC by using the “MCW-D 50 Conference” software. The parameters are adjusted for all microphone units. If a participant forgets to switch off his/her microphone and if nobody speaks into the microphone, the “Auto-Off” function switches
the microphone off. The time when the “Auto-Off” function will be activated and the sensitivity can be configured. A headphone (e.g. DT 1) can be connected to the documentation output. The volume of the loudspeaker is adjusted and can be controlled with the MCW-D 50 control unit or a media control system. The ducking level determines the attenuation of the loudspeaker level when the microphone of the microphone unit is switched on. Each microphone unit has its own address. An existing system can be complemented at any time.
The DSSS-transmission provides high immunity against unauthorised listening. In addition to this, a conference system including the appropriate microphone units can be protected with an 8-digit alphanumeric code. A microphone unit that does not have the correct code will be identified by the control unit and switched off immediately.
The integrated rechargeable battery allows an operation of the microphone unit for approx. 20 hours depending on the amount of participation in the discussion. As soon as the remaining battery time is below a certain threshold of 1 hour, the power on LED on the rear of the microphone unit will flash or if the system is controlled by PC or a media control system, the low battery capacity can be also indicated. The charging time of a completely empty battery is around 2 hours with the integrated processor-controlled charging electronics. Depending on the use of the microphone unit the charging time can be less. As an option the microphone unit can be powered and charged by a DC power supply adapter.
The microphone unit is switched on by briefly pressing the micro­phone button once. There are various ways to switch off the microphone unit:
1. Press the microphone button for 3 seconds.
2. Press the standby button of the MCW-D 50 control unit for
3 seconds to switch off all activated microphone units.
3. Switch off all microphone units via an RS 232 or TCP/IP
command from the PC or media control system.
4. Switch off the control unit; after approx. 3 minutes the micro-
phone unit will be switched off.
beyerdynamic GmbH & Co. KG Theresienstr. 8 | 74072 Heilbronn – Germany Tel. +49 (0) 71 31 / 617 - 0 | Fax +49 (0) 71 31 / 617 - 224 info@beyerdynamic.de | www.beyerdynamic.de
For further distributors worldwide, please go to www.beyerdynamic.com Non-contractual illustrations. Contents subject to change without notice. E5 / MCW-D 521 (11.09)
2 of 6